Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Addressing GPU memory limitations for Graph Neural Networks in High-Energy Physics applications

Introduction Reconstructing low-level particle tracks in neutrino physics can address some of the most fundamental questions about the universe. However, processing petabytes of raw data using deep learning techniques poses a challenging problem in the field of High Energy Physics (HEP). In the Exa.TrkX Project, an illustrative HEP application, preprocessed simulation data is fed into a state-of-art Graph Neural Network (GNN) model, accelerated by GPUs. However, limited GPU memory often leads to Out-of-Memory (OOM) exceptions during training, due to the large size of models and datasets. This problem is exacerbated when deploying models on High-Performance Computing (HPC) systems designed for large-scale applications. Methods We observe a high workload imbalance issue during GNN model training caused by the irregular sizes of input graph samples in HEP datasets, contributing to OOM exceptions. We aim to scale GNNs on HPC systems, by prioritizing workload balance in graph inputs while maintaining model accuracy. Our paper introduces diverse balancing strategies aimed at decreasing the maximum GPU memory footprint and avoiding the OOM exception, across various datasets. Results Our experiments showcase memory reduction of up to 32.14% compared to the baseline. We also demonstrate the proposed strategies can avoid OOM in application. Additionally, we create a distributed multi-GPU implementation using these samplers to demonstrate the scalability of these techniques on the HEP dataset. Discussion By assessing the performance of these strategies as data loading samplers across multiple datasets, we can gauge their effectiveness in both single-GPU and distributed environments. Our experiments, conducted on datasets of varying sizes and across multiple GPUs, broaden the applicability of our work to various GNN applications that handle input datasets with irregular graph sizes.

Lee, Claire Songhyun↗

A Comparative Multi-System Approach to Characterizing Bioactivity of Commonly Occurring Chemicals

A 2019 retrospective study analyzed wristband personal samplers from fourteen different communities across three different continents for over 1530 organic chemicals. Investigators identified fourteen chemicals (G14) detected in over 50% of personal samplers. The G14 represent a group of chemicals that individuals are commonly exposed to, and are mainly associated with consumer products including plasticizers, fragrances, flame retardants, and pesticides. The high frequency of exposure to these chemicals raises questions of their potential adverse human health effects. Additionally, the possibility of exposure to mixtures of these chemicals is likely due to their co-occurrence; thus, the potential for mixtures to induce differential bioactivity warrants further investigation. This study describes a novel approach to broadly evaluate the hazards of personal chemical exposures by coupling data from personal sampling devices with high-throughput bioactivity screenings using in vitro and non-mammalian in vivo models. To account for species and sensitivity differences, screening was conducted using primary normal human bronchial epithelial (NHBE) cells and early life-stage zebrafish. Mixtures of the G14 and most potent G14 chemicals were created to assess potential mixture effects. Chemical bioactivity was dependent on the model system, with five and eleven chemicals deemed bioactive in NHBE and zebrafish, respectively, supporting the use of a multi-system approach for bioactivity testing and highlighting sensitivity differences between the models. In both NHBE and zebrafish, mixture effects were observed when screening mixtures of the most potent chemicals. Observations of BMC-based mixtures in NHBE (NHBE BMC Mix) and zebrafish (ZF BMC Mix) suggested antagonistic effects. In this study, consumer product-related chemicals were prioritized for bioactivity screening using personal exposure data. High-throughput high-content screening was utilized to assess the chemical bioactivity and mixture effects of the most potent chemicals.

60 APPLIED LIFE SCIENCES↗

TRACER-Tethersonde VOC data

One objective of TRACER-Tethersonde campaign was to deploy a volatile organic compound (VOC) sampler on the Tethered Balloon System (TBS) to create vertical profiles and characterize VOC composition. Volatile organic compounds (VOCs) are highly reactive precursor species that undergo atmospheric processing to form secondary products, including aerosol. VOC emissions are influenced by many factors that include but are not limited to temperature, time of day, local anthropogenic activities, and local vegetation, which result in large spatiotemporal variability. The vertical distribution of volatile species is crucial for understanding gas-phase processing for particle production but challenging to accomplish using currently available sampling devices. The standalone sampler built during the campaign enabled the execution of robust experimental designs, including sample collection using resin tubes at multiple altitudes on subsequent flights. Following field sampling, resin tubes were transported back to Baylor University for chemical analysis using a Markes International thermal desorption unit coupled with a gas chromatograph-tandem mass spectrometer (Thermo Scientific). The target analyte list includes biogenic and anthropogenic VOCs.

54 ENVIRONMENTAL SCIENCES↗

tbsinp (00)

The ice nucleation spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice-nucleating particle (INP) number concentrations. It is almost identical to the Colorado State University (CSU) ice spectrometer design. The INS-AIR is specific to filter samples collected on aerial platforms, such as the DOE ARM tethered balloon system (TBS) operated by Sandia National Laboratories, using miniaturized aerosol filter samplers. Users are referred to the INS instrument handbook for INS-AIR sampler details. INS-AIR filter samples are collected during intensive operational periods at various ARM sites and then processed on the INS at CSU. This filter log contains the detailed metadata at all ARM sites where INP filter sample collection has occurred or is currently ongoing, including both ground-based routine INP sampling (INS) and TBS INP sampling (INS-AIR). Metadata include start and end times, vacuum line pressures and temperatures, and flow rates; total accumulated flow through each filter; and notes on collection issues or weather conditions. Users can also keep up to date with the status of filter and data processing, even before data are available on ARM’s Data Discovery. Users can contact INP mentors Jessie Creamean or Thomas Hill with any questions.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of plankton populations in upwelling areas

There are no author-identified significant results in this report. Repeated coverage over the test site along the northwest coast of Africa showed that the structure of chlorophyll distribution is much more complicated than expected from continuous recordings. ERTS-1 data showed a very fast change in the chlorophyll distribution and it seems that also the concentration changes quickly. ERTS-1 showed on some frames offshore transportation of dust from the Sahara. All frames from Channel 7 will be arranged as a montage to derive the transportation pattern of dust. This step is important in biological aspects of interpreting ERTS-1 data, because the dissolution kinetics of eolian dust particles may influence significantly the chemistry of the surface water. Since visibility and the biochemistry of the test site off Africa are influenced by the dust transport, dust collection will be included in the ground truth program. Besides chlorophyll and other hydrographical parameters, the dust load in the test area will be measured. The collection plan is discussed along with a description of the high volume air sampler and the Anderson particle sizing head sampler to be used for the dust measurements.

Szekielda, K.↗

Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

Neustadter, H. E.↗

Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing

Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants.

Susko, M.↗

Wallops waveform analysis of SEASAT-1 radar altimeter data

Fitting a six parameter model waveform to over ocean experimental data from the waveform samplers in the SEASAT-1 radar altimeter is described. The fitted parameters include a waveform risetime, skewness, and track point; from these can be obtained estimates of the ocean surface significant waveheight, the surface skewness, and a correction to the altimeter's on board altitude measurement, respectively. Among the difficulties encountered are waveform sampler gains differing from calibration mode data, and incorporating the actual SEASAT-1 sampled point target response in the fitted wave form. There are problems in using the spacecraft derived attitude angle estimates, and a different attitude estimator is developed. Points raised in this report have consequences for the SEASAT-1 radar altimeter's ocean surface measurements are for the design and calibration of radar altimeters in future oceanographic satellites.

Hayne, G. S.↗

Sample fields of the Viking landers, physical properties, and aeolian processes

Surface sampler activities on Mars during the Viking extended mission are considered, including excavation of deep trenches, construction of conical piles of materials, backhoe touchdown experiments, and acquisition of contiguous pictures of the surface beneath number 2 terminal descent engines using mirrors. Results of the Physical Properties Investigation that are relevant to aeolian processes are also discussed. Both pictures and surface sampler data indicate that the surface materials in the sample fields of the Viking landers may be grouped, in order of increasing strength, into drift material, crusty to cloddy material, blocky material and rocks.

Moore, H. J.↗

Sea-state-related altitude errors in the Seasat radar altimeter

A significant waveheight-dependent bias is identified in Seasat-measured surface heights which cannot be neglected when using Seasat data at accuracies within 10 cm. Ten-second averages of the data from 63 waveform sampling rates in the Seasat radar altimeter were least squares fitted with a six-parameter model, the time-origin parameter of which provides a measure of the position of the actual mean radar waveform relative to the sampling rate and therefore provides altitude measurement corrections. Attention is given to actual altimeter point target response function, waveform sampler noise baseline, waveform sampler gain calibration, attitude angle and sea surface skewness, as effects not accounted for in Seasat altimeter measurements and standard data processing.

Hayne, G. S.↗

Batch Gas-Sampling System

Sampler collects air or other gases in consistent way and stabilizes them for later chemical analysis. Device used for concentrations ranging from few parts per million to 100 percent. Also separates and collects particles in gas for analysis. Gas flows into vacuum sphere when solenoid valve opened. As it passes through conversion tube, constituent of gas forms stable compound that remains in conversion tube for analysis at later time. Sampler parts made of glass, polytetrafluoroethylene, and stainless steel so they do not react with sample.

Diaz, Vernon, Jr.↗

Corrections for the effects of significant wave height and attitude on Geosat radar altimeter measurements

Range estimates from a radar altimeter have biases which are a function of the significant wave height (SWH) and the satellite attitude angle (AA). Based on results of prelaunch Geosat modeling and simulation, a correction for SWH and AA was already applied to the sea-surface height estimates from Geosat's production data processing. By fitting a detailed model radar return waveform to Geosat waveform sampler data, it is possible to provide independent estimates of the height bias, the SWH, and the AA. The waveform fitting has been carried out for 10-sec averages of Geosat waveform sampler data over a wide range of SWH and AA values. The results confirm that Geosat sea-surface-height correction is good to well within the original dm-level specification, but that an additional height correction can be made at the level of several cm.

Hayne, G. S.↗

Comet nucleus and asteroid sample return missions

During the 1991-92 academic year, the Pennsylvania State University has developed three sample return missions: one to the nucleus of comet Wild 2, one to the asteroid Eros, and one to three asteroids located in the Main Belt. The primary objective of the comet nucleus sample return mission is to rendezvous with a short period comet and acquire a 10 kg sample for return to Earth. Upon rendezvous with the comet, a tethered coring and sampler drill will contact the surface and extract a two-meter core sample from the target site. Before the spacecraft returns to Earth, a monitoring penetrator containing scientific instruments will be deployed for gathering long-term data about the comet. A single asteroid sample return mission to the asteroid 433 Eros (chosen for proximity and launch opportunities) will extract a sample from the asteroid surface for return to Earth. To limit overall mission cost, most of the mission design uses current technologies, except the sampler drill design. The multiple asteroid sample return mission could best be characterized through its use of future technology including an optical communications system, a nuclear power reactor, and a low-thrust propulsion system. A low-thrust trajectory optimization code (QuickTop 2) obtained from the NASA LeRC helped in planning the size of major subsystem components, as well as the trajectory between targets.

Melton, Robert G.↗

Scales of variability of bio-optical properties as observed from near-surface drifters

A drifter equipped with bio-optical sensors and an automated water sampler was deployed in the California Current as part of the coastal transition zone program to study the biological, chemical, and physical dynamics of the meandering filaments. During deployments in 1987 and 1988, measurements were made of fluorescence, downwelling irradiance, upwelling radiance, and beam attenuation using several bio-optical sensors. Samples were collected by an automated sampler for later analysis of nutrients and phytoplankton species compositon. Large-scale spatial and temporal changes in the bio-optical and biological properties of the region were driven by changes in phytoplankton species composition which, in turn, were associated with the meandering circulation. Variance spectra of the bio-optical paramenters revealed fluctuations on both diel and semidiurnal scales, perhaps associated with solar variations and internal tides, respectively. Offshore, inertial-scale fluctuations were apparent in the variance spectra of temperature, fluorescence, and beam attenuation. Although calibration samples can help remove some of these variations, these results suggest that the use of bio-optical data from unattended platforms such as moorings and drifters must be analyzed carefully. Characterization of the scaled of phytoplankton variability must account for the scales of variability in the algorithms used to convert bio-optical measurments into biological quantities.

Abbott, Mark R.↗

Life in Extreme Environments Research #2

The goal of this project was to collect suspended particles and microbes for spectral analysis from deep water around hydrothermal vent study sites on the Juan de Fuca Ridge. To accomplish this, the McLane WTS 6-24-47 Sampler (McLane Research Laboratories, Falmouth, MA) was used. The WTS sampler is a programmable unit which is able to collect individual samples across twenty-four 47mm diameter filters at predetermined intervals and duration. Although only one successful deployment was needed, a maximum of three 3 deployments were possible (deployment opportunities were limited by the number of battery packs available). The initial behavior of the WTS and the ship's schedule both indicated that three deployments would be possible. However, it was revealed upon recovery after the first deployment that the WTS failed as it was preparing to collect its first sample.

Fisher, Charles R.↗

Intercomparisons of Airborne Measurements of Aerosol Ionic Chemical Composition during TRACE-P and ACE-Asia

As part of the two field studies, Transport and Chemical Evolution over the Pacific (TRACE-P), and the Asian Aerosol Characterization Experiment (ACEAsia), the inorganic chemical composition of tropospheric aerosols was measured over the western Pacific from three separate aircraft using various methods. Comparisons are made between the rapid online techniques of the Particle Into Liquid Sampler (PILS) for measurement of a suite of fine particle ionic compounds and a mist chamber (MC/IC) measurement of fine sulfate, and the longer time-integrated filter and multi-orifice impactor (MOI) measurements. Comparisons between identical PILS on two separate aircraft flying in formation showed that they were highly correlated (e.g., sulfate r(sup 2) of 0.95), but were systematically different by 10 +/- 5% (linear regression slope and 95% confidence bounds), and had generally higher concentrations on the aircraft with a low turbulence inlet and shorter inlet-to-instrument transmission tubing. Comparisons of PILS and mist chamber measurements of fine sulfate on two different aircraft during formation flying had an 3 of 0.78 and a relative difference of 39% +/- 5%. MOI ionic data integrated to the PILS upper measurement size of 1.3 pm sampling from separate inlets on the same aircraft showed that for sulfate, PILS and MOI were within 14% +/- 6% and correlated with an r(sup 2) of 0.87. Most ionic compounds were within f 30%, which is in the range of differences reported between PILS and integrated samplers from ground-based comparisons. In many cases, direct intercomparison between the various instruments is difficult due to differences in upper-size detection limits. However, for this study, the results suggest that the fine particle mass composition measured from aircraft agree to within 30-40%.

Ma, Y.↗

Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling

Standard penetrator sampling systems were designed in order to allow for sampling via penetrators to produce a full set of sample acquisitions including volatile liquids, fine powders, and solid fragments. A gravity harpoon sampler has been designed with a removable tip and a quick coupling. The separation allows for sample handling and eliminates sample cross-contamination. Also, this design allows for multiple use of the penetrator body, which is the largest and heaviest part of the penetrator, while allowing for multiple changes of the light-mass, penetrator tip to avoid sample cross-contamination. The penetrator tip design has been improved by adding a spring trap to retain the sample, as well as a means for connecting to a quick coupling. Quick connect tips have been demonstrated in a sample handling carousel. The penetrator was released and rewound and the tips were released into a circular platter for rotation into instrument stations. The pyro-harpoon sampler was fabricated and tested with a NASA Standard Initiator (NSI) pyrotechnic charge. Initial tests collected cryogenic ice, but removal of the small pyro-harpoon from the ice was difficult. A brass metal sheath was then fitted over the harpoon tip, and removal from the ice was greatly alleviated by leaving the sheath in the ice. Quartz windows in the tips allow direct optical and spectral imaging and gas chromatography-mass spectrometer (GCMS) pyrolysis, and were found to survive impact. All systems were successfully tested by dropping into sand and into cryogenic ice.

Sherritt, Stewart↗

Surface Contact Model for Comets and Asteroids

A contact force model was developed for use in touch and go (TAG) surface sampling simulations on small celestial bodies such as comets and asteroids. In TAG scenarios, a spacecraft descending toward the surface of a small body comes into contact with the surface for a short duration of time, collects material samples with a sampler device, and then ascends to leave the surface. The surface contact required 6-DOF (degrees of freedom) dynamics models due to coupling of the attitude and translation dynamics during the contact. The model described here is for contact scenarios that utilize a rotating brush wheel sampler (BWS) to collect surface material. The model includes stiffness and damping of the surface material during BWS vertical motion, lateral friction from the BWS dragging across the surface, and lateral shear from the rotating BWS scooping the surface material. This model is useful for any mission to asteroids or comets that incorporates surface sampling operations.

Blackmore, Lars James C.↗