Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCREEN EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles

Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!

Aldridge, Edward↗

Screen-Printed SHJ Solar Cells with Complex Silver Inks

Metallization using complex metal inks has gained significant research interest due to its cost-effectiveness and ability to achieve performance comparable to traditional nanoparticle pastes. This study introduces the use of complex silver (Ag) inks applied via industrial screen-printing for silicon heterojunction (SHJ) solar cell metallization. The printed Ag lines exhibit a contact resistivity on SHJ tin-doped indium oxide (ITO) surfaces as low as approximately 0.2-12 mO cm2. Photoluminescence imaging reveals minimal surface passivation degradation (iVoc < 3.5 mV), while scanning electron microscopy (SEM) shows a denser structure compared to Ag layer from nanoparticle pastes. The printed Ag grid features thin (approximately 1 micrometer), continuous fingers approximately 100-120 micrometer wide, significantly thinner than conventional approximately 20-30 micrometer fingers produced with nanoparticle-based pastes. Double printing achieves SHJ device efficiencies exceeding 20%, the highest reported for industrial solar cell precursors using this technology. These findings highlight the potential of complex Ag inks as a sustainable alternative to particle-based pastes, reducing Ag consumption and processing temperatures without compromising efficiency.

14 SOLAR ENERGY↗

Magnetic Penetration Effects in Small Superconducting Devices

The temperature dependent behavior of a superconducting body in an applied magnetic field involves flux penetration/expulsion both from screening currents (within a magnetic penetration depth) and variations in the superconducting order parameter (locally to form vortices or a mixed state, or globally in the Meissner effect). The temperature dependence of the magnetic penetration depth, in particular, has been used to make highly sensitive macroscopic thermometers. For the microscopic device volumes required in sensitive low temperature photon detectors, properties of actual thin film materials, non-uniformity of applied magnetic fields, and the influence of measurement circuit dynamics are complicating factors. We discuss the various penetration effects as demonstrated in a particularly promising combination of material and geometry that we have used to make sensitive x-ray microcalorimeters.

Stevenson, T. R.↗

Enhanced Images for Checked and Carry-on Baggage and Cargo Screening

The current X-ray systems used by airport security personnel for the detection of contraband, and objects such as knives and guns that can impact the security of a flight, have limited effect because of the limited display quality of the X-ray images. Since the displayed images do not possess optimal contrast and sharpness, it is possible for the security personnel to miss potentially hazardous objects. This problem is also common to other disciplines such as medical Xrays, and can be mitigated, to a large extent, by the use of state-of-the-art image processing techniques to enhance the contrast and sharpness of the displayed image. The NASA Langley Research Center's Visual Information Processing Group has developed an image enhancement technology that has direct applications to this problem of inadequate display quality. Airport security X-ray imaging systems would benefit considerably by using this novel technology, making the task of the personnel who have to interpret the X-ray images considerably easier, faster, and more reliable. This improvement would translate into more accurate screening as well as minimizing the screening time delays to airline passengers. This technology, Retinex, has been optimized for consumer applications but has been applied to medical X-rays on a very preliminary basis. The resultant technology could be incorporated into a new breed of commercial x-ray imaging systems which would be transparent to the screener yet allow them to see subtle detail much more easily, reducing the amount of time needed for screening while greatly increasing the effectiveness of contraband detection and thus public safety.

Woodell, Glenn↗

Enhanced Images for Checked and Carry-on Baggage and Cargo Screening

The current X-ray systems used by airport security personnel for the detection of contraband, and objects such as knives and guns that can impact the security of a flight, have limited effect because of the limited display quality of the X-ray images. Since the displayed images do not possess optimal contrast and sharpness, it is possible for the security personnel to miss potentially hazardous objects. This problem is also common to other disciplines such as medical X-rays, and can be mitigated, to a large extent, by the use of state-of-the-art image processing techniques to enhance the contrast and sharpness of the displayed image. The NASA Langley Research Centers Visual Information Processing Group has developed an image enhancement technology that has direct applications to this problem of inadequate display quality. Airport security X-ray imaging systems would benefit considerably by using this novel technology, making the task of the personnel who have to interpret the X-ray images considerably easier, faster, and more reliable. This improvement would translate into more accurate screening as well as minimizing the screening time delays to airline passengers. This technology, Retinex, has been optimized for consumer applications but has been applied to medical X-rays on a very preliminary basis. The resultant technology could be incorporated into a new breed of commercial x-ray imaging systems which would be transparent to the screener yet allow them to see subtle detail much more easily, reducing the amount of time needed for screening while greatly increasing the effectiveness of contraband detection and thus public safety.

Woodell, Glen↗

Flow visualization of the wake of a transport aircraft model with lateral-control oscillations

An exploratory flow visualization study conducted in the Langley Vortex Research Facility to investigate the effectiveness of lateral control surface oscillations as a potential method for wake vortex attenuation on a 0.03 scale model of a wide body jet transport aircraft is described. Effects of both asymmetric surface oscillation (control surfaces move as with normal lateral control inputs) and symmetric surface oscillation (control surfaces move in phase) are presented. The asymmetric case simulated a flight maneuver which was previously investigated on the transport aircraft during NASA/FAA flight tests and which resulted in substantial wake vortex attenuation. Effects on the model wake vortex systems were observed by propelling the model through a two dimensional smoke screen perpendicular to the model flight path. Results are presented as photographic time histories of the wake characteristics recorded with high speed still cameras. Effects of oscillation on the wake roll up are described in some detail, and the amount of vortex attenuation observed is discussed in comparative terms. Findings were consistent with flight test results in that only a small amount of rotation was observed in the wake for the asymmetric case. A possible aerodynamic mechanism contributing to this attenuation is suggested.

Jordan, F. L., Jr.↗

Phonon Screening of Excitons in Atomically Thin Semiconductors

Atomically thin semiconductors, encompassing both 2D materials and quantum wells, exhibit a pronounced enhancement of excitonic effects due to geometric confinement. Consequently, these materials have become foundational platforms for the exploration and utilization of excitons. Recent ab initio studies have demonstrated that phonons can substantially screen electron-hole interactions in bulk semiconductors and strongly modify the properties of excitons. While excitonic properties of atomically thin semiconductors have been the subject of extensive theoretical investigations, the role of phonon screening on excitons in atomically thin structures remains unexplored. In this Letter, we demonstrate via ab initio GW-Bethe-Salpeter equation calculations that phonon screening can have a significant impact on optical excitations in atomically thin semiconductors. We further show that the degree of phonon screening can be tuned by structural engineering. We focus on atomically thin GaN quantum wells embedded in AlN and identify specific phonons in the surrounding material, AlN, that dramatically alter the lowest-lying exciton in monolayer GaN via screening. Our studies provide new intuition beyond standard models into the interplay among structural properties, phonon characteristics, and exciton properties in atomically thin semiconductors, and have implications for future experiments.

2-dimensional systems↗

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Synthetic aperture radar operator tactical target acquisition research

A radar target acquisition research study was conducted to access the effects of two levels of 13 radar sensor, display, and mission parameters on operator tactical target acquisition. A saturated fractional-factorial screening design was employed to examine these parameters. Data analysis computed ETA squared values for main and second-order effects for the variables tested. Ranking of the research parameters in terms of importance to system design revealed four variables (radar coverage, radar resolution/multiple looks, display resolution, and display size) accounted for 50 percent of the target acquisition probability variance.

Hershberger, M. L.↗

Virtual space and 2-dimensional effects in perspective displays

When interpreting three dimensional spatial relationships presented on a two dimensional display surface, the viewer is required to mentally reconstruct the original information. This reconstruction is influenced by both the perspective geometry of the displayed image and the viewer's eye position relative to the display. In a study which manipulated these variables, subjects judged the azimuth direction of a target object relative to a reference object fixed in the center of a perspective display. The results support a previously developed model which predicted that the azimuth judgement error would be a sinusoidal function of stimulus azimuth. The amplitude of this function was correctly predicted to be systematically modulated by both the perspective geometry of the image and the viewer's eye position relative to the screen. Interaction of the two components of the model, the virtual space effect and the 3D-to-2D projection effect, predicted the relative amplitudes of the sinusoidal azimuth error functions for the various conditions of the experiment. Mean azimuth judgements in some directions differed by as much as 25 degrees as a result of different combinations of eye position and image geometry. The results illustrate the need to consider the effects of perspective geometry when designing spatial information instruments, and show the model to be a reliable predictor of average performance.

Mcgreevy, M. W.↗

Optical Property Enhancement and Durability Evaluation of Heat Receiver Aperture Shield Materials

Under the Solar Dynamic Flight Demonstration (SDFD) program, NASA Lewis Research Center worked with AlliedSignal Aerospace, the heat receiver contractor, on the development, characterization and durability testing of refractory metals to obtain appropriate optical and thermal properties for the SDFD heat receiver aperture shield. Molybdenum and tungsten foils were grit-blasted using silicon carbide or alumina grit under various grit-blasting conditions for optical property enhancement. Black rhenium coated tungsten foil was also evaluated. Tungsten, black rhenium-coated tungsten, and grit-blasted tungsten screens of various mesh sizes were placed over the pristine and grit-blasted foils for optical property characterization. Grit-blasting was found to be effective in decreasing the specular reflectance and the absorptance/emittance ratio of the refractory foils. The placement of a screen further enhanced these optical properties, with a grit-blasted screen over a grit-blasted foil producing the best results. Based on the optical property enhancement results, samples were tested for atomic oxygen and vacuum heat treatment durability. Grit-blasted (Al2O3 grit) 2 mil tungsten foil was chosen for the exterior layer of the SDFD heat receiver aperture shield. A 0.007 in. wire diameter, 20 x 20 mesh tungsten screen was chosen to cover the tungsten foil. Based on these test results, a heat receiver aperture shield test unit has been built with the screen covered grit-blast tungsten foil exterior layers. The aperture shield was tested and verified the thermal and structural durability of the outer foil layers during an off-pointing period.

deGroh, Kim K.↗

The effect of free-stream turbulence on heat transfer from a flat plate

Turbulence was generated by using screens, and the turbulence percentage was measured by a hot-wire anemometer both in the boundary layer and the free stream. The local heat-transfer coefficient was measured at 12 locations along the plate for the cases of various turbulence levels. The transition Reynolds number from laminar to turbulent flow decreases as the main-stream turbulence level increases. In the range of laminar heat transfer the effect of turbulence in the main flow was not great, but in the range of turbulent heat transfer the heat-transfer coefficient increases according to the increase of turbulence.

HEAT TRANSFER, AERODYNAMIC↗

On the relation between SMMR 37-GHz polarization difference and the rainfall over Africa and Australia

A major difficulty in interpreting coarse resolution satellite data in terms of land surface characteristics is unavailability of spatially and temporally representative ground observations. Under certain conditions rainfall has been found to provide a proxy measure for surface characteristics, and thus a relation between satellite observations and rainfall might provide an indirect approach for relating satellite data to these characteristics. Relationship between rainfall over Africa and Australia and 7-year average (1979-1985) polarization difference (PD) at 37 GHz from scanning multichannel microwave radiometer (SMMR) on board the Nimbus-7 satellite is studied in this paper. Quantitative methods have been used to screen (accept or reject) PD data considering antenna pattern, geolocation uncertainty, water contamination, surface roughness, and adverse effect of drought on the relation between rainfall and surface characteristics. The rainfall data used in the present analysis are climatologic averages and also 1979-1985 averages, and no screening has been applied to this data. The PD data has been screened considering only the location of rainfall stations, without any regard to rainfall amounts. The present analysis confirms a non-linear relation between rainfall and PD published previously.

Choudhury, Bhaskar J.↗

Effect of Modifications to Induction System on Altitude Performance of V-1710-93 Engine III : Use of Parabolic Rotating Guide Vanes and NACA Designed Auxiliary-stage Inlet Elbow and Interstage Duct

Bench runs of a modified V-1710-93 engine equipped with a two-stage supercharger, interstage carburetor, aftercooler assembly, and backfire screens have been made at a simulated altitude of 29,000 feet to determine the effect of several induction-system modifications on the engine and supercharger performance. The standard guide vanes on the auxiliary- and engine-stage superchargers were replaced by rotating guide vanes with a parabolic blade profile. The auxiliary-stage inlet elbow and interstage duct were replaced with new units of NACA design. These modifications were made one at a time and data were obtained after each change to determine the effect of each modification. All runs were made at a constant engine speed of 3000 rpm at a simulated altitude of 29,000 feet and all changes in engine power were made by varying the speed of the auxiliary-stage supercharger.

Standahar, Ray M↗

Local microwave sensing of excitons and their electrical environment

Excitons in atomically thin transition metal dichalcogenides (TMDs) possess intriguing optical properties, drawing interest for both technology and fundamental research. However, as the demands for nanodevice applications and the exploration of fundamental physics push toward smaller, subwavelength scales, studying them locally is challenging. In this work, we introduce a cryogenic scanning probe photoelectrical sensing technique, termed exciton-resonant microwave impedance microscopy (ER-MIM), to measure the excitonic responses in a monolayer MoSe 2 device at 1.5K. From the microwave signal changes, we identify exciton polarons and their Rydberg states. Building on these observations, we systemically reveal the local and nonlocal effects of carrier density, inhomogeneous electric fields, as well as dielectric screening on excitons, beyond the reach of conventional probes. By further integrating deep learning techniques, we precisely extracted the electrical parameters surrounding excitons, demonstrating a quantified, exciton-assisted nanoscale electrometry. Our results provide new insight into exciton-environment interactions, establish ER-MIM as a powerful optoelectronic sensing platform, and open avenues for exciton-based quantum control and device technologies.

scanning probe microscopy↗

Irradiation of Advanced Cladding Specimens in the High Flux Isotope Reactor: Capsule Designs and Test Matrix

The Advanced Fuels Campaign (AFC) has initiated the Advanced Reactor Cladding (ARC) irradiation campaign to generate irradiation performance data for candidate fuel cladding concepts. The campaign includes a diverse set of ferritic/martensitic steels, oxide dispersion strengthened (ODS) alloys, FeCrAlbased alloys, coated materials, and welded cladding specimens produced through multiple US Department of Energy (DOE) programs and international collaborations. Three complementary experimental thrusts comprise the campaign: tensile testing (ARC Tensile) to rapidly screen candidate alloys, fracture toughness testing (ARC Fracture) to evaluate irradiation effects on crack resistance, and tubular weld testing (ARC Weld) to quantify irradiation-induced changes in the mechanical performance of end cap welds. This report documents the irradiation campaign design, including the selected materials, specimen types, irradiation matrix, and capsule designs for irradiation within the High Flux Isotope Reactor (HFIR). A total of 14 irradiation capsules were developed to achieve target irradiation temperatures between 300°C and 600°C and doses up to 30 dpa. Thermal analyses were performed using finite element methods to establish capsule geometries capable of achieving the desired specimen temperatures while accommodating differences in specimen geometry and material properties. The resulting capsule designs provide the basis for irradiation of the AFC-ARC experimental matrix and subsequent post-irradiation examination to assess the effects of neutron irradiation on advanced cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of insulation materials and composites for use in a nuclear radiation environment, phase 2

The nuclear heating of the propellant in all of the four baseline RNS configurations studied was much lower than that of the nuclear flight module configuration with the 5000-MW NERVA analyzed previously. Although the nuclear heating has been reduced, the effect of nuclear heating on the propellant as well as the effect of nuclear heating on internal structures such as antivortex baffles, screens, and sump components cannot be neglected. In addition, it was found that the present analytical precedures were not able to predict boundary layer initiation and breakoff points with the accuracy necessary to predict propellant thermodynamic nonequilibrium (stratification) and/or mixing.

Westerheide, D. E.↗

Automated mass spectrometer/analysis system: A concept

System performs rapid multiple analyses of entire compound classes or individual compounds on small amounts of sample and reagent. Method will allow screening of large populations for metabolic disorders and establishment of effective-but-safe levels of therapeutic drugs in body fluids and tissues.

Boettger, H. G.↗