At least 361 records · Page 20

Enhancement of High-Speed Infrared Array Electronics (Center Director's Discretionary Fund)

A state-of-the-art infrared detector was to be used as the sensor in a new spectrometer-camera for astronomical observations. The sensitivity of the detector required the use of low-noise, high-speed electronics in the system design. The key component in the electronic system was the pre-amplifier that amplified the low voltage signal coming from the detector. The system was designed based on the selection of the amplifier and that was driven by the maximum noise level, which would yield the desired sensitivity for the telescope system.

Sutherland, W. T.↗

Reducing systematic bias in machine learning applications to J/ψ signal extraction in high-energy nuclear physics

Machine learning techniques are increasingly used in high-energy nuclear physics because they can exploit multivariate correlations more efficiently than conventional cut-based analyses. A central challenge is the construction of training samples that faithfully reproduce the detector response observed in data. Signal samples are usually derived from detector simulations; therefore, mismatches between simulation and data can degrade classifier performance and introduce systematic biases. This work presents two practical correction procedures, namely cumulative distribution function (CDF) mapping and a shift-and-scale transformation, to align simulated signal features with those measured in data. Their performance is demonstrated with $J$/$\psi$ yield measurements in $\sqrt{s_{nn}}$ = 200 GeV Ru+Ru and Zr+Zr collisions recorded by STAR. A set of self-consistency tests shows that these procedures substantially suppress the systematic bias associated with data-simulation discrepancies in machine-learning-based signal extraction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent Doppler Wind Lidar Technology for Space Based Wind Measurements Including SPARCLE

It has been over 30 years since coherent lidar systems first measured wind velocity, and over 20 years since the "ultimate application" of measuring Earth's winds from space was conceived. Coherent or heterodyne optical detection involves the combination (or mixing) of the returned optical field with a local oscillator (LO) laser's optical field on the optical detector. This detection technique yields the benefits of dramatically improved signal-to-noise ratios; insensitivity to detector noise, background light and multiply scattered light; reduction of the returned signal's dynamic range; and preservation of the optical signal spectrum for electronic and computer processing. (Note that lidar systems are also referred to as optical radar, laser radar, and LADAR systems.) Many individuals, agencies, and countries have pursued the goal of space-based wind measurements through technology development, experiments, field campaigns and studies.

Kavaya, Michael J.↗

Monte Carlo Simulations of the Response of the MARIE Instrument

The MARIE instrument aboard Mars Odyssey functions as a telescope for the detection of charged, energetic, nuclei. The directionality that leads to the telescope description is achieved by requiring coincident signals in two designated detectors in MARIE s silicon detector stack for the instrument to trigger. Because of this, MARIE is actually a bi directional telescope. Triggering particles can enter the detector stack by passing through the lightly shielded front of the instrument, but can also enter the back of the instrument by passing through the bulk of Odyssey. Because of this, understanding how to relate the signals recorded by MARIE to astrophysically important quantities such as particle fluxes or spectra exterior to the spacecraft clearly requires detailed modeling of the physical interactions that occur as the particles pass through the spacecraft and the instrument itself. In order to facilitate in the calibration of the MARIE data, we have begun a program to simulate the response of MARIE using the FLUKA [1] [2] Monte Carlo radiation transport code.

Andersen, V.↗

MODIS Solar Diffuser Attenuation Screen Modeling Results

On-orbit calibration of the reflected solar bands on the EOS Moderate Resolution Imaging Spectroradiometer (MODIS) is accomplished by have the instrument view a high reflectance diffuse surface illuminated by the sun. For some of the spectral bands this proves to be much too bright a signal that results in the saturation of detectors designed for measuring low reflectance (ocean) surfaces signals. A mechanical attenuation device in the form of a pin hole screen is used to reduce the signals to calibrate these bands. The sensor response to solar illumination of the SD with and without the attenuation screen in place will be presented. The MODIS detector response to the solar diffuser is smooth when the attenuation screen is absent, but has structures up to a few percent when the attenuation screen is present. This structure corresponds to non-uniform illumination from the solar diffuser. Each pin hole produces a pin-hole image of the sun on the solar diffuser, and there are very many pin hole images of the sun on the solar diffuser for each MODIS detector. Even though there are very many pin-hole images of the sun on the solar diffuser, it is no longer perfectly uniformly illuminated. This non-uniformly illuminated solar diffuser produces intensity variation on the focal planes. The results of a very detailed simulation will be discussed which show how the illumination of the focal plane changes as a result of the attenuation, and the impacts on the calibration will be discussed.

Waluschka, Eugene↗

All-sky search for gravitational waves

We present a set of general tools to search for multiparameter gravitational-wave signals buried in the noise of a detector.

gravitational waves signal detection↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Application of infrared radiometers for airborne detection of clear air turbulence and low level wind shear, airborne infrared low level wind shear detection test

The feasibility of infrared optical techniques for the advance detection and avoidance of low level wind shear (LLWS) or low altitude wind shear hazardous to aircraft operations was investigated. A primary feasibility research effort was conducted with infrared detectors and instrumentation aboard the NASA Ames Research Center Learjet. The main field effort was flown on the NASA-Ames Dryden B57B aircraft. The original approach visualized a forward-looking, infrared transmitting (KRS-5) window through which signals would reach the detector. The present concept of a one inch diameter light pipe with a 45 deg angled mirror enables a much simpler installation virtually anywhere on the aircraft coupled with the possibility of horizontal scanning via rotation of the forward directed mirror. Present infrared detectors and filters would certainly permit ranging and horizontal scanning in a variety of methods. CRT display technology could provide a contoured picture with possible shear intensity levels from the infrared detection system on the weather radar or a small adjunct display. This procedure shoud be further developed and pilot evaluated in a light aircraft such as a Cessna 207 or equivalent.

Kuhn, P. M.↗

Time-of-flight vs time-of-arrival in neutron spectroscopic measurements for high energy density plasmas

The neutron time-of-flight (nToF) diagnostic technique has a lengthy history in Inertial Confinement Fusion (ICF) and High Energy Density (HED) Science experiments. Its initial utility resulted from the simple relationship between the full width half maximum of the fusion peak signal in a distant detector and the burn averaged conditions of an ideal plasma producing the flux [Lehner and Pohl, Z. Phys. 207, 83–104 (1967)]. More recent precision measurements [Gatu-Johnson et al., Phys. Rev. E 94(8), 021202 (2016)] and theoretical studies [Munro, Nucl. Fusion 56, 035001 (2016)] have shown the spectrum to be more subtle and complicated, driving the desire for an absolute calibration of the spectrum to disambiguate plasma dynamics from the conditions producing thermonuclear reactions. In experiments where the neutron production history is not well measured, but the neutron signal is preceded by a concomitant flux of photons, the spectrum can be in situ calibrated using a set of collinear detectors to obtain a true “time-of-flight” measurement. This article presents the motivation and overview of this technique along with estimates of the experimental precision needed to make useful measurements in existing and future nToF systems such as the pulsed power Z-machine located in Albuquerque, NM, at Sandia National Laboratories.

Fusion experiments↗

Analysis of Moessbauer Data from Mars: A Database and Artificial Neural Network for Identification of Iron-bearing Phases

The exploration of the planet Mars is one of the major goals within the Solar system exploration programs of the US-American space agency NASA and the European Space Agency ESA. In particular the search for water and life and understanding of the history of the surface and atmosphere will be the major tasks of the upcoming space missions to Mars. The miniaturized Moessbauer spectrometer MIMOS II has been selected for the NASA Mars-Exploration-Rover twin-mission to Mars in 2003 and the ESA 2003 Mars-Express Beagle 2 mission. Reduced in size and weight, in comparison to ordinary laboratory setup, the sensor head just weights approximately 400 g, with a volume of (50x50x90) cu mm, and holds two gamma-ray sources: the stronger for experiments and the weaker for calibrations. The collimator (in sample direction) also shields the primary radiation off the detectors. Around the drive four detectors are mounted. The detectors are made of Si-PIN-photodiodes in chip form (100 sq mm, thickness of 0.5 mm). The control unit is located in a separate electronics board. This board is responsible for the power supply, generation of the drive's velocity reference signal, read of the detector pulses to record the spectrum, data storage and communication with the host computer. After more than four decades from the discovery of the Moessbauer effect, more than 400 minerals were studied at different temperatures. Their Moessbauer parameters were reported in the literature, and have been recently collected in a data bank. Previous Mars-missions, namely Viking and Mars Pathfinder, revealed Si, Al, Fe, Mg, Ca, K, Ti, S and Cl to be the major constituents in soil and rock elemental composition of the red planet. More than 200 minerals already studied by Moessbauer spectroscopy contain significant amounts of these elements. A considerable number of Moessbauer studies were also carried out on meteorites and on Moon samples. Looking backward in the studies of the whole Moessbauer community, we have built a specific library containing Moessbauer parameters of those possible Mars minerals. The selected minerals, their Moessbauer parameter values (min. max. s.d and number of available data), main site substitution, behavior as a function of temperature and a ranking as expected to be found on Mars were organized. Mars-analogue Fe-bearing minerals not studied by Moessbauer spectroscopy are being collected and investigated. In addition, it an identification system based on Artificial Neural Networks (ANN) was implemented which enables fast and precise mineral identification from the experimental Moessbauer parameters at a given temperature.

P A de Souza Jr.↗

Double Differential Encoding And Detection In MPSK

Proposed communication system based on multiple-phase-shift-keying (MPSK) modulation includes double differential encoder in transmitter and double differential detector in receiver. Transmitter generates phase-modulated signal suitable for decoding and detection by subsystem. Detector removes Doppler-frequency component from noisy, Doppler-shifted signal encoded in subsystem. Overall effect of double-differential scheme to cancel effect of Doppler shift on modulation in received signal. Not necessary to estimate Doppler shift to correct for it.

Divsalar, D.↗

Micro-Pulse Lidar Signals: Uncertainty Analysis

Micro-pulse lidar (MPL) systems are small, autonomous, eye-safe lidars used for continuous observations of the vertical distribution of cloud and aerosol layers. Since the construction of the first MPL in 1993, procedures have been developed to correct for various instrument effects present in MPL signals. The primary instrument effects include afterpulse, laser-detector cross-talk, and overlap, poor near-range (less than 6 km) focusing. The accurate correction of both afterpulse and overlap effects are required to study both clouds and aerosols. Furthermore, the outgoing energy of the laser pulses and the statistical uncertainty of the MPL detector must also be correctly determined in order to assess the accuracy of MPL observations. The uncertainties associated with the afterpulse, overlap, pulse energy, detector noise, and all remaining quantities affecting measured MPL signals, are determined in this study. The uncertainties are propagated through the entire MPL correction process to give a net uncertainty on the final corrected MPL signal. The results show that in the near range, the overlap uncertainty dominates. At altitudes above the overlap region, the dominant source of uncertainty is caused by uncertainty in the pulse energy. However, if the laser energy is low, then during mid-day, high solar background levels can significantly reduce the signal-to-noise of the detector. In such a case, the statistical uncertainty of the detector count rate becomes dominant at altitudes above the overlap region.

Welton, Ellsworth J.↗

Photon number resolving detection with a single-photon detector and adaptive storage loop

Abstract Photon number resolving (PNR) measurements are beneficial or even necessary for many applications in quantum optics. Unfortunately, PNR detectors are usually large, slow, expensive, and difficult to operate. However, if the input signal is multiplexed, photon ‘click’ detectors, that lack an intrinsic PNR capability, can still be used to realize photon number resolution. Here, we investigate the operation of a single click detector, together with a storage line with tunable outcoupling. Using adaptive feedback to adjust the storage outcoupling rate, the dynamic range of the detector can in certain situations be extended by up to an order of magnitude relative to a purely passive setup. An adaptive approach can thus allow for photon number variance below the quantum shot noise limit under a wider range of conditions than using a passive multiplexing approach. This can enable applications in quantum enhanced metrology and quantum computing.

Sullivan, Nicholas M. (ORCID:0000000248447296)↗

Automatic quadrature control and measuring system

Quadrature is separated from amplified signal by use of phase detector, with phase shifter providing appropriate reference. Output of phase detector is further amplified and filtered by dc amplifier. Output of dc amplifier provides signal to neutralize quadrature component of transducer signal.

Hamlet, J. F.↗

A re-examination of impulsive VLF signals in the night ionosphere of Venus

Consideration is given to the impulsive electrical signals clustered around periapsis which were observed by the Pioneer Venus Orbiter Electric Field Detector. The study of these signals by Singh and Russell is repeated, taking into account the telemetry errors noted by Taylor and Cloutier (1988). It is found that there is naturally occurring noise in the dark ionosphere of Venus near periapsis. The absolute rates of occurrence are determined, showing differences with the results from the original study.

Russell, C. T.↗

Concepts for Neutrino Applications

Will neutrinos find uses outside basic science? It may be too early to say, but neutrino physicists have already imagined a variety of possibilities from the relatively modest to the more blue-sky. In this review, we survey the range of proposed applications, most involving nuclear reactors and other fission sources. We give special attention to the most recent proposals, including verifying submarine reactor integrity, safeguarding advanced nuclear power plants, and monitoring spent nuclear fuel. All of these concepts take advantage of the fact that neutrinos pass through barriers other signals cannot penetrate. That same fact creates the central challenge for neutrino applications: the size and complexity of detectors needed to collect a signal. Although the weakly interacting nature of neutrinos makes them fundamentally difficult to use, developments in detector technology are making some ideas more feasible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Miniature Tunable Laser Spectrometer for Detection of a Trace Gas

An open-path laser spectrometer (OPLS) for measuring a concentration of a trace gas, the OPLS including an open-path multi-pass analysis region including a first mirror, a second mirror at a distance and orientation from the first mirror, and a support structure for locating the mirrors, a laser coupled to the analysis region and configured to emit light of a wavelength range and to enable a plurality of reflections of the emitted light between the mirrors, a detector coupled to the analysis region and configured to detect a portion of the emitted light impinging on the detector and to generate a corresponding signal, and an electronic system coupled to the laser and the detector, and configured to adjust the wavelength range of the emitted light from the laser based on the generated signal, and to measure the concentration of the trace gas based on the generated signal.

Christensen, Lance E.↗

Triac failure detector

A failure detector is provided for detecting unidirectional failures in triacs, particularly as used in power factor controllers for induction motors. In a first embodiment, the triac voltage waveform is sensed and upon detection of an unbalanced signal, corresponding to failure of the triac in either the positive or negative direction, the triac is turned full on in both directions. In a second embodiment, a pair of pulsed signals are derived, the pulse durations of which are proportional to the phase difference between the load current and voltage for each half cycle, and the triac is turned full on responsive to a difference in pulse duration between the half cycle signals. An unidirectional open circuit detector is adapted to use a signal from either of the first and second embodiment to turn the triac off in response to an open circuit failure in either direction.

Nola, F. J.↗