Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

PDV Probe Alignment Technique

This alignment technique was developed while performing heterodyne velocimetry measurements at LLNL. There are a few minor items needed, such as a white card with aperture in center, visible alignment laser, IR back reflection meter, and a microscope to view the bridge surface. The work was performed on KCP flyers that were 6 and 8 mils wide. The probes used were Oz Optics manufactured with focal distances of 42mm and 26mm. Both probes provide a spot size of approximately 80?m at 1550nm. The 42mm probes were specified to provide an internal back reflection of -35 to -40dB, and the probe back reflections were measured to be -37dB and -33dB. The 26mm probes were specified as -30dB and both measured -30.5dB. The probe is initially aligned normal to the flyer/bridge surface. This provides a very high return signal, up to -2dB, due to the bridge reflectivity. A white card with a hole in the center as an aperture can be used to check the reflected beam position relative to the probe and launch beam, and the alignment laser spot centered on the bridge, see Figure 1 and Figure 2. The IR back reflection meter is used to measure the dB return from the probe and surface, and a white card or similar object is inserted between the probe and surface to block surface reflection. It may take several iterations between the visible alignment laser and the IR back reflection meter to complete this alignment procedure. Once aligned normal to the surface, the probe should be tilted to position the visible alignment beam as shown in Figure 3, and the flyer should be translated in the X and Y axis to reposition the alignment beam onto the flyer as shown in Figure 4. This tilting of the probe minimizes the amount of light from the bridge reflection into the fiber within the probe while maintaining the alignment as near normal to the flyer surface as possible. When the back reflection is measured after the tilt adjustment, the level should be about -3dB to -6dB higher than the probes specified back reflection. This 3 to 6dB increase in back reflection from the surface relative to the probes specified back reflection is the optimal level for acquiring data from the flyer. Data obtained with the LLNL system is shown in Figure 5.

42 ENGINEERING↗

Strong intracellular signal inactivation produces sharper and more robust signaling from cell membrane to nucleus

For a chemical signal to propagate across a cell, it must navigate a tortuous environment involving a variety of organelle barriers. In this work we study mathematical models for a basic chemical signal, the arrival times at the nuclear membrane of proteins that are activated at the cell membrane and diffuse throughout the cytosol. Organelle surfaces within human B cells are reconstructed from soft X-ray tomographic images, and modeled as reflecting barriers to the molecules’ diffusion. We show that signal inactivation sharpens signals, reducing variability in the arrival time at the nuclear membrane. Inactivation can also compensate for an observed slowdown in signal propagation induced by the presence of organelle barriers, leading to arrival times at the nuclear membrane that are comparable to models in which the cytosol is treated as an open, empty region. In the limit of strong signal inactivation this is achieved by filtering out molecules that traverse non-geodesic paths.

59 BASIC BIOLOGICAL SCIENCES↗

Hyperspectral imaging of minerals in the longwave infrared: the use of laboratory directional-hemispherical reference measurements for field exploration data

Hyperspectral Imaging (HSI) continues to grow as a method for remote detection of vegetation, materials, minerals, and pure chemicals. We have used a longwave infrared (7.7 - 11.8 µm) imaging spectrometer in a static outdoor experiment to collect HSI data from 24 minerals and background materials to determine the efficacy with which HSI can remotely detect and distinguish both pure minerals and mineral mixtures at three solar angles (25°, 35°, and 45° relative to ground) as well as varying backgrounds and other sample effects. Measurements were obtained separately for the minerals and materials mounted directly both on a bare plywood board and a plywood board coated with aluminum foil: 19 powders (3 mixtures and 16 pure mineral powders) held in polyethylene bottle lids as well as 5 samples in rock form were taped directly to the boards. The primary goal of the experiment was to demonstrate that a longwave infrared (LWIR) library of solids and minerals collected as directional-hemispherical reflectance spectra in the laboratory can be used directly for HSI field identification. Prior to the experiment, all 24 mineral/inorganic samples were measured in the laboratory using a Fourier transform infrared spectrometer (FTIR) equipped with a gold-coated IR integrating sphere; the spectra were assimilated as part of a larger reference library of 21 pure minerals, 3 mixtures, and the polyethylene lid. Principal components analysis (PCA) with mean-centering was used in an exploratory analysis of the HSI images and showed that for the aluminum coated board, the first principal component captured the difference between signal that resembled a blackbody and the highly reflective aluminum background. In contrast, principal components PC 2, 3, and 4 were able to discriminate the materials including phosphates, sulfates, silicates, carbonates, and the mixtures. Results from generalized least squares target detection clearly showed that laboratory reference spectra of minerals could be utilized as targets with high fidelity for field detection, both for pure and mixed samples.

47 OTHER INSTRUMENTATION↗

Final Scientific/Technical report for "ABI8: Prototype of a novel signaling factor"

The Arabidopsis thaliana ABSCISIC ACID-INSENSITIVE8 locus encodes a highly conserved plant-specific protein that mediates abscisic acid (ABA) and sugar responses essential for growth. Although initial database comparisons revealed no domains of predictable function, it has recently been re-annotated as a member of the Glycosyltransferase family A. However, this function has not been demonstrated experimentally and no specific substrates have been identified. Mutations affecting ABI8 are near-lethal due to pleiotropic yet specific effects including altered ABA signaling, sugar transport, cell wall synthesis, root meristem maintenance, vascular patterning, and male sterility. Because the predicted sequence initially provided no clues, we used a guilt by association strategy to address function of this protein by determining its subcellular localization and identifying interacting proteins. Our studies showed that ABI8 is localized to the endomembrane system and may interact with proteins implicated in Golgi trafficking, lignification, and stress signaling. We found that the root meristem arrest reflects decreased auxin accumulation and resulting decreases in regulators required for meristem identity, all of which can be rescued by added glucose. Further studies showed that this glucose-dependence reflects reduced glucose uptake as well as the decreased expression of sugar-mobilizing enzymes. This work suggests that ABI8 may regulate trafficking of membrane proteins such as auxin transporters and cellulose synthase, but this hypothesis has not yet been tested. The altered gene expression is likely to be a secondary or later effect of this pleiotropic mutation.

59 BASIC BIOLOGICAL SCIENCES↗

The SuperCam remote sensing instrument suite for the Mars 2020 rover mission: A preview

We present that the SuperCam remote sensing instrument suite under development for the National Aeronautics and Space Administration’s (NASA) Mars 2020 rover performs laser-induced breakdown spectroscopy (LIBS), remote Raman spectroscopy, visible and infrared (VISIR) reflectance spectroscopy, acoustic sensing, and high-resolution color imaging. The instrument builds on the successful architecture of the ChemCam instrument, which provides LIBS and panchromatic images on the Curiosity rover, adding remote Raman spectroscopy by frequency doubling the laser and using a gated intensified detector to obtain Raman signals at distances to 12 m. To the visible reflectance spectroscopy used by ChemCam, an acousto-optic tunable filter (AOTF)-based IR spectrometer is added to cover the 1.3–2.6 µm range that contains important mineral signatures. A complementary metal-oxide semiconductor (CMOS) detector provides color (Bayer filter) images at a pixel resolution of 19 µrad and an optical resolution of 30 µrad. Sounds are recorded via a Knowles Electret microphone, which is the same one that was included but not used on two earlier missions. The acoustic signals of the LIBS plasmas will provide information on the hardness of the targets, while other sounds (wind, rover sounds) will also be recorded. The laser, telescope, IR spectrometer, and camera reside on the rover’s mast and are provided by the Centre national d’etudes spatiales (CNES), while the LIBS, Raman, and VIS spectrometers and data processing unit are built by Los Alamos National Laboratory (LANL) and reside in the rover body. A calibration target assembly provided by the University of Valladolid, Spain, resides on the back of the rover. Lastly, the overall mass of the instrument suite is 10.7 kg.

47 OTHER INSTRUMENTATION↗

Software-Defined Ultrasonic Communication System Based on Time-reversal Signal Processing

Ultrasonic communication through solid channels suffers from channel dispersion, attenuation, and multipath effect. For example, in elbow shape pipes or complex structures, the elastic waves are reflected and reverberated in multipath resulting in a major dispersion of the signals. In solid channels such as flat bar, multipath propagation is the main reason for bit-wavelet spreading and intersymbol interference (ISI). The conventional modulation method like OOK (on-off-keying) or PSK (phase-shift-keying) fails to provide a useful Signal-to-Noise Ratio (SNR). Time-reversal (TR) signal processing method is a promising technique that can compress the spreading of the bit-wavelet and strengthen the peak signal energy on the receiver. In this study, Finite Element Analysis (FEA) using ABAQUS software tools is used to characterize the bit-wavelet spreading effect caused by dispersive communication channels. Also, this study presents the impact of TR ultrasonic communication as a function of excitation pulse width, channel length, and carrier frequency through a flat-bar channel. A Software-Defined System-on-Chip (SD-SoC) platform is examined as a viable solution for the low-complexity and energy-efficient ultrasonic communication system. The proposed TR based SD-SoC ultrasonic communication system can make full use of signal dispersion for peak performance by minimizing the ISI within a dispersive and reverberant metal channel.

FEM simulation↗

The effects of the ionosphere on ground-based detection of the global 21 cm signal from the cosmic dawn and the dark ages

Detection of the global H i 21 cm signal from the Cosmic Dawn and the Epoch of Reionization is the key science driver for several ongoing ground-based and future ground-/space-based experiments. The crucial spectral features in the global 21 cm signal (turning points) occur at low radio frequencies ≲100 MHz. In addition to the human-generated radio frequency interference, Earth’s ionosphere drastically corrupts low-frequency radio observations from the ground. In this paper, we examine the effects of time-varying ionospheric refraction, absorption, and thermal emission at these low radio frequencies and their combined effect on any ground-based global 21 cm experiment. It should be noted that this is the first study of the effect of a dynamic ionosphere on global 21 cm experiments. The fluctuations in the ionosphere are influenced by solar activity with flicker noise characteristics. The same characteristics are reflected in the ionospheric corruption to any radio signal passing through the ionosphere. As a result, any ground-based observations of the faint global 21 cm signal are corrupted by flicker noise (or 1/f noise, where f is the dynamical frequency) which scales as ν{sup −2} (where ν is the frequency of radio observation) in the presence of a bright galactic foreground (∝ν{sup −s}, where s is the radio spectral index). Hence, the calibration of the ionosphere for any such experiment is critical. Any attempt to calibrate the ionospheric effects will be subject to the inaccuracies in the current ionospheric measurements using Global Positioning System (GPS) ionospheric measurements, riometer measurements, ionospheric soundings, etc. Even considering an optimistic improvement in the accuracy of GPS–total electron content measurements, we conclude that Earth’s ionosphere poses a significant challenge in the absolute detection of the global 21 cm signal below 100 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Geophysical Signatures of Crack Network Coalescence in Rocks at Multiple Length Scales

The main goal of the research project was to identify the geophysical signatures of fracture growth in natural rocks by utilizing novel geophysical techniques. The research objectives were to (a) investigate the potential for geophysical methods to determine when cracks initiate, the types and locations of propagated cracks, and the coalescence of networks of cracks in natural rocks at multiple scales, (b) determine how damage at the microscale evolved into damage at the macroscale and then link the microscopic and macroscopic observations, (c) quantify crack coalescence in rocks under realistic stress conditions using coupled mechanical-geophysical-optical visualization, and (d) identify the precursors in geophysical signals to crack coalescence. The following research thrusts were explored to achieve the research objectives: (1) uniaxial compression testing of rock specimens with and without a set of pre‐existing flaws and (2) triaxial compression testing of natural rock specimens. These thrusts allowed for exploring fracturing in rocks under realistic in situ environments and at multiple scales. This project provided educational opportunities for nine graduate and undergraduate students and resulted in 27 peer-reviewed publications. This first research thrust focused on investigating the micromechanics of fractures in rocks through uniaxial compression testing combined with advanced geophysical and imaging techniques, specifically acoustic emission (AE) monitoring, ultrasonic imaging, and 2-dimensional Digital Image Correlation (2D-DIC). By examining damage processes under time-independent and time-dependent loading conditions, insights into damage localization, crack initiation, and fracturing mechanisms were gained. It was observed that the AE signals and the strain-based measurements directly reflect the state of damage in the rock specimen and could be used to identify the cracking levels, such as the crack initiation (CI) and crack damage (CD), and the mode of deformation. A novel calibration apparatus was developed to enhance the accuracy of AE sensors, allowing for the estimation of key parameters such as magnitude, source dimension, stress drop, and radiated seismic energy associated with the fractures. The findings highlighted significant variations in the temporal evolution of AE source parameters during the primary, secondary, and tertiary stages of creep, identifying tensile cracking as the primary deformation mode. The second research thrust focused on enhancing the understanding of fracturing processes in natural rocks through triaxial compression testing, real-time AE monitoring, and ultrasonic monitoring. We investigated the impact of various factors such as fracture propagation regimes, injection parameters, rock types, and pre-existing conditions on the hydraulic fracture (HF) behavior using scaled true-triaxially loaded specimens of Barre granite and Lyons sandstone. Custom sensor housing facilitated concurrent active and passive monitoring to analyze hydro-mechanical responses and microseismicity associated with different HF scenarios. A coupled investigation of passive microseismicity and active signal attributes permitted a detailed comprehension of the various HF processes (aseismic deformation, fracture initiation and propagation, fluid permeation, and leak-off) and their dependence on the specific rock type. The findings of this research demonstrated the effectiveness of AE monitoring techniques in providing valuable insights into the impact of various factors on the behavior and dynamics of HF processes. The advancements in monitoring techniques, offering a more thorough and precise approach, represent a significant step towards optimizing HF practices and ensuring sustainable resource extraction.

58 GEOSCIENCES↗

Laser induced deflection technique for absolute thin film absorption measurement: optimized concepts and experimental results

Using experimental results and numerical simulations, two measuring concepts of the laser induced deflection (LID) technique are introduced and optimized for absolute thin film absorption measurements from deep ultraviolet to IR wavelengths. For transparent optical coatings, a particular probe beam deflection direction allows the absorption measurement with virtually no influence of the substrate absorption, yielding improved accuracy compared to the common techniques of separating bulk and coating absorption. For high-reflection coatings, where substrate absorption contributions are negligible, a different probe beam deflection is chosen to achieve a better signal-to-noise ratio. Various experimental results for the two different measurement concepts are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STL-548 Non-Reflecting Protective Unit (NRPU)

This report describes the fundamental operation of the key operating points of the NRPU system, which is a 50-ohm system that protects front-end digitizers from large signal pulses and is designed to limit large signals while passing smaller signals in a single-shot type experiment with little back-reflection.

1GHz high voltage front-end digitizer protection↗

An estimation method for echo signal energy of pipe inner surface longitudinal crack detection by 2-D energy coefficients integration

The echo signal energy is directly affected by the incident sound beam eccentricity or angle for thick-walled pipes inner longitudinal cracks detection. A method for analyzing the relationship between echo signal energy between the values of incident eccentricity is brought forward, which can be used to estimate echo signal energy when testing inside wall longitudinal crack of pipe, using mode-transformed compression wave adaptation of shear wave with water-immersion method, by making a two-dimension integration of “energy coefficient” in both circumferential and axial directions. The calculation model is founded for cylinder sound beam case, in which the refraction and reflection energy coefficients of different rays in the whole sound beam are considered different. The echo signal energy is calculated for a particular cylinder sound beam testing different pipes: a beam with a diameter of 0.5 inch (12.7mm) testing a φ279.4mm pipe and a φ79.4mm one. As a comparison, both the results of two-dimension integration and one-dimension (circumferential direction) integration are listed, and only the former agrees well with experimental results. The estimation method proves to be valid and shows that the usual method of simplifying the sound beam as a single ray for estimating echo signal energy and choosing optimal incident eccentricity is not so appropriate.

36 MATERIALS SCIENCE↗

Measuring cloud thermodynamic phase with shortwave infrared imaging spectroscopy

Shortwave Infrared imaging spectroscopy enables accurate remote mapping of cloud thermodynamic phase at high spatial resolution. Here, we describe a measurement strategy to exploit signatures of liquid and ice absorption in cloud top apparent reflectance spectra from 1.4 to 1.8 μm. This signal is generally insensitive to confounding factors such as solar angles, view angles, and surface albedo. We first evaluate the approach in simulation and then apply it to airborne data acquired in the Calwater-2/ACAPEX campaign of Winter 2015. Here NASA’s “Classic” Airborne Visible Infrared Imaging Spectrometer (AVIRIS-C) remotely observed diverse cloud formations while the U.S. Department of Energy ARM Aerial Facility G-1 aircraft measured cloud integral and microphysical properties in situ. Finally, the coincident measurements demonstrate good separation of the thermodynamic phases for relatively homogeneous clouds.

54 ENVIRONMENTAL SCIENCES↗

Infrared spectroscopy investigation of Fe-promoted Rh catalysts supported on Titania and Ceria for CO hydrogenation

The nature of the promotional effect of Fe addition to Rh/TiO 2 and Rh/CeO 2 catalysts for CO hydrogenation was investigated using FT-IR spectroscopy in an ultrahigh vacuum compatible transmission IR cell. CO adsorption experiments on Rh and FeRh showed vibrational signatures characteristic of linear and bridge bound CO on Rh0 as well as geminal-dicarbonyl species associated with Rh + . Compared to TiO 2 , the CeO 2 -supported catalysts show increased dispersion, reflected by decreased particle size, and a lower signal for linear versus geminal-dicarbonyl bonded CO. The absorption frequencies for CO on Rh/CeO 2 are also redshifted relative to Rh/TiO 2 , which results from a weaker Rh–CO interaction, likely due to the increased reducibility of the CeO 2 support. Upon addition of Fe, a new spectral feature is observed and attributed to CO bound to Rh in close contact with Fe, likely as a surface alloy. CO hydrogenation on (Fe)Rh catalysts on both supports was also studied. Compared to bare Rh, Fe containing catalysts promote formate and methoxy species on the surface at lower temperature (180 °C), which suggests an enhancement in methanol selectivity by Fe addition. Furthermore, at higher temperatures (220 °C), the spectral features appear similar, further confirming the role of Fe as a disrupter of large Rh o crystallites and regulator of CO dissociation and CH 4 formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of edge density profiles of Large Helical Device plasmas using an ultrashort-pulse reflectometer

We report here on the application of an ultrashort-pulse reflectometer (USPR) to Large Helical Device in National Institute for Fusion Science. An impulse with picosecond pulse width is used as a source in an USPR. Since the bandwidth of a source is inversely related to the pulse width, we can utilize the frequency range of microwave to millimeter-wave by using wide band transmission lines. The density profiles can be reconstructed by collecting time-of-flight signal of each frequency component of an impulse reflected from each cutoff layer. Remote control system using super science information network has been introduced to the present USPR system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1+1' resonant multiphoton ionisation of OH radicals via the A 2 Σ + state: insights from direct comparison with A-X laser-induced fluorescence detection

Here, a 1+1' resonance-enhanced multiphoton ionisation (REMPI) scheme for OH X 2 Π radicals is characterised for a broad range of intermediate A 2 Σ + ( v = 1, J , F i ) levels. The intensities of OH A-X (1,0) transitions detected by subsequent fixed-frequency VUV ionisation are compared among those obtained by near simultaneous laser-induced fluorescence (LIF) measurements. The ratios of the 1+1' REMPI to LIF signals are used to derive enhancement factors which reflect the VUV absorption to the OH A 3 Π, 3 d , v = 0 Rydberg state and/or the fast autoionisation process that yields OH + ions. The determination of the enhancement factors permits 1+1' REMPI to be utilised as a quantitative state-specific probe of OH X 2 Π radicals.

74 ATOMIC AND MOLECULAR PHYSICS↗

Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data

We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from Pb210decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we also perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. Finally, we confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗