Search NASA⌕ Search

SEARCH · Search NASA

Results for “Safety Boundary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Chapter 12 - Flight Envelope

The term "flight envelope" is used to refer to the boundaries of aircraft loading and flight conditions within which operation of the aircraft is satisfactory, and beyond which some aspect becomes unacceptable. This flight envelope represents, in fact, the limiting conditions arising from a matrix of inter-related flight envelopes covering the appropriate variables. Thus, for each loading (i.e., external stores configuration and its associated range of weight and center of gravity (c.g.) position) and aircraft configuration (i.e., position of undercarriage (u/c), flaps, slats, etc.), the envelopes of airspeed versus altitude, airspeed versus load factor, angle of attack versus angle of sideslip, etc., must be investigated to establish the limits within which all aspects such as handling qualities, engine behavior, structural loads, etc., remain acceptable. Flight testing of new or derivative aircraft models is carried out with the initial purpose of defining a flight envelope which is, first and foremost, safe and secondarily, which enables the effective use of the vehicle for its intended purpose. Flight testing occurs only after numerous reviews of the design and review of results from ground tests and predictions of flight characteristics in such areas as structures, aerodynamics, stability and control, flight controls (particularly fly-by-wire control systems, propulsion, etc.). Accordingly, opening and expanding the envelope is a task that must be approached cautiously, systematically, and with coordination and cooperation of the many disciplines involved in the design and test of an airplane. (Sections 8 and 10 cover test planning and safety of flight considerations, respectively). The fundamental tenet in establishing a flight envelope via flight test is risk reduction. This is reflected in the typical sequence of events leading to initial flight test - design reviews (both hardware and software), then ground test involving singular disciplines (windtunnel tests for aerodynamics, structurally loading the wing/fuselage/nacelle on a ground test article with loads anticipated to occur in flight, flight control system control law checkout, propulsion test cell runs and/or flying test bed tests, etc.), and then ground tests involving multi-disciplines (See Section 9). Only after these have been accomplished will an initial, limited, low-risk, flight envelope be established. The limited envelope will typically be in the middle of the projected final flight envelope. Subsequent flight tests will then be devoted to expanding the initial envelope by operating the airplane at increasing ranges - representing increasing risk - of engine operation, airspeeds both fast and slow, altitude, load factor both above and below 1g, centers of gravity (fore and aft), and with system/subsystem failures. Whether flight tests are to define a flight envelope on a new model airplane with the attendant new airframe, new engine(s), and new subsystems (hydraulics, pressurization, etc.), or on an airplane involving only a few of these areas such as new engines in an old airframe, the fundamental approach to establishing an envelope is the same.

H Walgemoed↗

Oxide‐Based Solid‐State Batteries: A Perspective on Composite Cathode Architecture

Abstract The garnet‐type phase Li 7 La 3 Zr 2 O 12 (LLZO) attracts significant attention as an oxide solid electrolyte to enable safe and robust solid‐state batteries (SSBs) with potentially high energy density. However, while significant progress has been made in demonstrating compatibility with Li metal, integrating LLZO into composite cathodes remains a challenge. The current perspective focuses on the critical issues that need to be addressed to achieve the ultimate goal of an all‐solid‐state LLZO‐based battery that delivers safety, durability, and pack‐level performance characteristics that are unobtainable with state‐of‐the‐art Li‐ion batteries. This perspective complements existing reviews of solid/solid interfaces with more emphasis on understanding numerous homo‐ and heteroionic interfaces in a pure oxide‐based SSB and the various phenomena that accompany the evolution of the chemical, electrochemical, structural, morphological, and mechanical properties of those interfaces during processing and operation. Finally, the insights gained from a comprehensive literature survey of LLZO–cathode interfaces are used to guide efforts for the development of LLZO‐based SSBs.

25 ENERGY STORAGE↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗

A novel path to runaway electron mitigation via deuterium injection and current-driven MHD instability

Relativistic electron (RE) beams at high current density (low safety factor, qa) yet very low free-electron density accessed with D2 secondary injection in the DIII-D and JET tokamak are found to exhibit large-scale MHD instabilities that benignly terminate the RE beam. In JET, this technique has enabled termination of MA-level RE currents without measurable first-wall heating. This scenario thus offers an unexpected alternate pathway to achieve RE mitigation without collisional dissipation. Benign termination is explained by two synergistic effects. First, during the MHD-driven RE loss events both experiment and MHD orbit-loss modeling supports a significant increase in the wetted area of the RE loss. Second, as previously identified at JET and DIII-D, the fast kink loss timescale precludes RE beam regeneration and the resulting dangerous conversion of magnetic to RE kinetic energy. During the termination, the RE kinetic energy is lost to the wall, but the current fully transfers to the cold bulk thus enabling benign Ohmic dissipation of the magnetic energy on longer timescales via a conventional current quench. Hydrogenic (D2) secondary injection is found to be the only injected species that enables access to the benign termination. D2 injection: 1) facilitates access to low qa in existing devices (via reduced collisionality & resistivity), 2) minimizes the RE avalanche by ‘purging’ the high-Z atoms from the RE beam, 3) drives recombination of the background plasma, reducing the density and Alfven time, thus accelerating the MHD growth. Furthermore, this phenomenon is found to be accessible when crossing the low qa stability boundary with rising current, falling toroidal field, or contracting minor radius - the latter being the expected scenario for vertically unstable RE beams in ITER. While unexpected, this path scales favorably to fusion-grade tokamaks and offers a novel RE mitigation scenario in principle accessible with the day-one disruption mitigation system (DMS) of ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Investigation of Impact of Technological Impairment on Trajectory-Based Operations

The Next Generation Air Transportation System (NextGen) incorporates collaborative air traffic management and Trajectory-Based Operations (TBO) in order to significantly increase the capacity, efficiency, and predictability of operations in the National Airspace System (NAS), without decreasing safety. This is enabled by airspace users and service providers sharing knowledge about operations that allows prediction of the complete 4D flight trajectory with as little uncertainty as possible. Additionally, new software and hardware technology is critical to reaching NextGen goals, especially with regard to TBO. What if the technologies that are critical for TBO were to be impaired or fail completely? Should there be a malfunction of a piece of the technology, it must be ensured that the whole system does not break down completely or suffer severe impairment. Instead, operations need to be maintained proportionally to the problem and safety needs to be ensured (graceful degradation). This paper proposes a systematic framework to investigate the vulnerability of TBO to technology disruption, and determine the impact of technological impairment on TBO. Two representative technologies are chosen for detailed investigation and the impact of their impairment on the degradation of TBO is illustrated using a weather-related scenario. XXXX There are several possible directions of future work. We believe it is desirable to develop methods to quantitatively assess the impact of technological disruption on TBO and to have the simulation tools to validate the impact. The availability of prognostics and health management methods could be leveraged to predict technological failure/disruption, thus predicting how TBO will be a ected, and possibly pro-actively mitigating the impact. It is important to develop large-scale scenarios where the e ect of technological impairment is prominent, and identify methods to quantitatively assess the extent of TBO degradation. An important goal of such an investigation is the development of failure-resistant resilient trajectory-based oper- ations. Resilience14, 15 is the property of a system to \bounce back" and resume at least a signi cant portion of its functionalities after degradation due to technological impairment(s). A systems resilience includes properties such as \bu ering capacity" (quantifying disruptions the system can absorb or adapt to without a fundamental breakdown in performance or in the systems structure), \ exibility" (ability to restructure itself in response to external changes or pressures), "margin" (how closely the system is currently operating rela- tive to one or another kind of performance boundary), \tolerance" (whether the system gracefully degrades as stress/pressure increase, or collapses quickly when pressure exceeds adaptive capacity), etc. Future work needs to focus on quantifying and improving the resilience of TBO, and identifying resilient design solutions for aviation.

TBO↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Explainable Data-Driven Turbulence Models with Application to Liquid Fuel Nuclear Reactors

Liquid fuel nuclear reactors offer innovative possibilities in terms of nuclear reactor designs and passive safety systems. Molten Salts Reactors (MSRs) with a fast spectrum are a particular type of these reactors using liquid fuel. MSFRs often involve large open cavities in their core in which the liquid fuel circulates at a high speed to transport the heat generated by the nuclear reactions into the heat exchangers. This high-speed flow yields a turbulent field with large Reynolds numbers in the reactor core. Since the nuclear power, the neutron precursor’s transport and the thermal exchanges are strongly coupled in the MSFR’s core cavity, having accurate turbulent models for the liquid fuel flow is necessary to avoid introducing significant errors in the numerical simulations of these reactors. Nonetheless, high-accuracy simulations of the turbulent flow field in the reactor cavity of these reactors are usually prohibitively expensive in terms of computational resources, especially when performing multiphysics numerical calculations. Therefore, in this work, we propose a novel method using a modified genetic algorithm to optimize the calculation of the Reynolds Shear Stress Tensor (RST) used for turbulence modeling. The proposed optimization methodology is particularly suitable for advanced liquid fuel reactors such as the MSFRs since it allows the development of high-accuracy but still low-computational-cost turbulence models for the liquid fuel. We demonstrate the applicability of this approach by developing high accuracy Reynolds-Averaged Navier–Stokes (RANS) models (averaged flow error less than 5%) for a low and a large aspect ratio in a Backward-Facing Step (BFS) section particularly challenging for RANS models. The newly developed turbulence models better capture the flow field after the boundary layer tipping, over the extent of the recirculation bubble, and near the boundary layer reattachment region in both BFS configurations. The main reason for these improvements is that the developed models better capture the flow field turbulent anisotropy in the bulk region of the BFS. Then, we illustrate the interest in using this turbulence modeling approach for the case of an MSFR by quantifying the impact of the turbulence modeling on the reactor key parameters.

42 ENGINEERING↗

Fuel-Cladding Eutectic Study of Legacy Fast Flux Test Facility (FFTF) MFF HT9/U-10Zr Metallic Fuel

This report presents the first systematic investigation of fuel-cladding eutectic interaction (FCEI) in irradiated HT9/U-10Zr metallic fuel from the Fast Flux Test Facility (FFTF) Materials Fuels Form (MFF) program, using differential scanning calorimetry (DSC) coupled with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Two irradiated fuel cross-sections, MNT07H (9.5 at% burnup, x/L = 0.78) and MNT08H (7.0 at% burnup, x/L = 0.93), were subjected to three successive isothermal annealing rounds (R1–R3) at 820°C for 20 minutes each, yielding a cumulative transient duration of one hour. This study directly addresses a recognized gap in the existing FCEI database, which previously lacked irradiated HT9/U-10Zr data at burnup levels above 8 at%. Two principal findings emerge from the study. First, for both samples, FCEI remained spatially confined within the pre-existing fuel-cladding chemical interaction (FCCI) zone boundaries after R3, with no measurable eutectic penetration into unaffected cladding beyond the original FCCI layer. This self-limiting behavior is consistent with historical Fuel Behavior Test Apparatus (FBTA) results and is attributed to the near-eutectic phase composition of the FCCI zone, which rapidly absorb the available eutectic-forming constituents and then stall penetration once the FCCI zone is consumed. A comparison with unirradiated surrogate data further supports this mechanism: whereas a U–34 at.% Fe sample would be expected to show ~176 µm of iron penetration under comparable conditions, the irradiated samples exhibited only ~20 µm, a discrepancy attributed to irradiation-induced interfacial porosity and pre-existing FCCI composition gradients. Second, for MNT08H, FCEI was observed exclusively on the half of the cladding circumference where pre-existing steady-state FCCI was present, with no detectable FCEI on the opposite half. Three hypotheses are proposed to explain this asymmetry: the inhibiting role of a zirconium-rich rind at the fuel-cladding interface; the chemical sequestration of iron by redistributed zirconium within the fuel matrix; and the persistence of fuel-cladding gaps on the FCEI-free half that preclude direct contact. All three hypotheses require further experimental investigation. The results extend the empirical FCEI database into higher-burnup territory and demonstrate the viability of DSC-based testing as a substitute for the no-longer-available FBTA apparatus. Future work will include additional cross-section testing, compilation of the full FCEI dataset, model evaluation, and DSC testing of ternary fuel compositions to broaden the experimental basis for safety assessment of sodium-cooled fast reactor systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Situational Awareness Sensor Suite for the ISS (SASSI): A Mission Concept to Investigate ISS Charging and Wake Effects

The complex interaction between the International Space Station (ISS) and the surrounding plasma environment often generates unpredictable environmental situations that affect operations. Examples of affected systems include extravehicular activity (EVA) safety, solar panel efficiency, and scientific instrument integrity. Models and heuristically‐derived best practices are well‐suited for routine operations, but when it comes to unusual or anomalous events or situations, especially those driven by space weather, there is no substitute for real‐time monitoring. Space environment data collected in real‐time (or near‐real time) can be used operationally for both real‐time alarms and data sources in assimilative models to predict environmental conditions important for operational planning. Fixed space weather instruments mounted to the ISS can be used for monitoring the ambient space environment, but knowing whether or not (or to what extent) the ISS affects the measurements themselves requires adequate space situational awareness (SSA) local to the ISS. This paper presents a mission concept to use a suite of plasma instruments mounted at the end of the ISS robotic arm to systematically explore the interaction between the Space Station structure and its surrounding environment. The Situational Awareness Sensor Suite for the ISS (SASSI) would be deployed and operated on the ISS Express Logistics Carrier (ELC) for long‐term "survey mode" observations and the Space Station Remote Manipulator System (SSRMS) for short‐term "campaign mode" observations. Specific areas of investigation include: 1) ISS frame and surface charging during perturbations of the local ISS space environment, 2) calibration of the ISS Floating Point Measurement Unit (FPMU), 3) long baseline measurements of ambient ionospheric electric potential structures, 4) electromotive force-induced currents within large structures moving through a magnetized plasma, and 5) wake‐induced ion waves in both electrostatic (i.e. particles) and electromagnetic modes. SASSI will advance the understanding of plasma‐boundary interaction phenomena, demonstrate a suite a sensors acting in concert to provide effective SSA, and validate and/or calibrate existing ISS space environment instruments and models.

Krause, L. Habash↗

Cybersecurity Lessons Learned from Vehicle to Grid Engagement

As the transportation industry continues to become electrified, introduction of additional digital devices within associated actions such as recharging bring additional potential for cybersecurity attacks. Devices that are designed, implemented, and operated with cybersecurity as a crucial consideration exacerbate these concerns by failing to provide strict boundaries on access to and use of the equipment. Emerging use cases such as Vehicle to Grid (V2G) charging may expand the potential physical effects of a cybersecurity attack by providing indirect access to electrical components of a building microgrid or portions of the larger power grid. This paper serves as an overview of findings and recommendations based on cybersecurity testing performed at a V2G implementation site operated by a member of the Memorandum of Understanding (MOU) to Establish the Vehicle-to-Everything (V2X) Collaboration [1]. The Department of Energy Office of Cybersecurity, Energy Security, and Emergency Response is a signatory of the MOU, and has funded this research paper and associated body of work regarding V2X cybersecurity. Sandia has a large background of previous research focused on Electric Vehicle (EV) cybersecurity, such as reference [2], which includes an overall survey of EV infrastructure cybersecurity and recommendations based on those findings. This report seeks to expand knowledge of EV cybersecurity status and needs by focusing on a specific implementation of V2G charging, and providing recommendations based on the relevant findings. This report serves as a publicly available, sanitized description of applied vulnerability testing on an operational V2G implementation. A more in-depth technical version of the report is provided to the MOU partner, but not available at the time of writing due to inclusion of proprietary information. V2G charging comes with many research problems that must be solved before the technology can securely implemented in sites with unrestricted public access or where cybersecurity attacks could have increased consequences, such as government offices. V2G charging requires many stakeholders such as end users, host sites, equipment vendors, and integrators, which all rely on operational safety and security as well as security and trustworthiness of any associated financial transactions.

33 ADVANCED PROPULSION SYSTEMS↗

NASA Tech Briefs, December 2009

Topics include: A Deep Space Network Portable Radio Science Receiver; Detecting Phase Boundaries in Hard-Sphere Suspensions; Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery; Very-Long-Distance Remote Hearing and Vibrometry; Using GPS to Detect Imminent Tsunamis; Stream Flow Prediction by Remote Sensing and Genetic Programming; Pilotless Frame Synchronization Using LDPC Code Constraints; Radiometer on a Chip; Measuring Luminescence Lifetime With Help of a DSP; Modulation Based on Probability Density Functions; Ku Telemetry Modulator for Suborbital Vehicles; Photonic Links for High-Performance Arraying of Antennas; Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration; Hardware-Efficient Monitoring of I/O Signals; Video System for Viewing From a Remote or Windowless Cockpit; Spacesuit Data Display and Management System; IEEE 1394 Hub With Fault Containment; Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph; Waveguide Transition for Submillimeter-Wave MMICs; Magnetic-Field-Tunable Superconducting Rectifier; Bonded Invar Clip Removal Using Foil Heaters; Fabricating Radial Groove Gratings Using Projection Photolithography; Gratings Fabricated on Flat Surfaces and Reproduced on Non-Flat Substrates; Method for Measuring the Volume-Scattering Function of Water; Method of Heating a Foam-Based Catalyst Bed; Small Deflection Energy Analyzer for Energy and Angular Distributions; Polymeric Bladder for Storing Liquid Oxygen; Pyrotechnic Simulator/Stray-Voltage Detector; Inventions Utilizing Microfluidics and Colloidal Particles; RuO2 Thermometer for Ultra-Low Temperatures; Ultra-Compact, High-Resolution LADAR System for 3D Imaging; Dual-Channel Multi-Purpose Telescope; Objective Lens Optimized for Wavefront Delivery, Pupil Imaging, and Pupil Ghosting; CMOS Camera Array With Onboard Memory; Quickly Approximating the Distance Between Two Objects; Processing Images of Craters for Spacecraft Navigation; Adaptive Morphological Feature-Based Object Classifier for a Color Imaging System; Rover Slip Validation and Prediction Algorithm; Safety and Quality Training Simulator; Supply-Chain Optimization Template; Algorithm for Computing Particle/Surface Interactions; Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images; and Thermal Transport Model for Heat Sink Design.

Source record↗

DECOVALEX-2023: Task C Final Report

The Full-scale Emplacement (FE) heater experiment at the Mont Terri Underground Rock Laboratory (URL) was designed and conducted by Nagra to replicate an emplacement tunnel of Nagra’s reference repository design at 1:1 scale. Alongside testing the technical feasibility of constructing disposal tunnels, emplacing waste containers in the tunnels and then backfilling them, the main goals of the FE experiment are (1) to obtain a better understanding of the coupled effects of induced thermo-hydro-mechanical (THM) processes that may occur and (2) to validate existing coupled THM models (Müller et al., 2017). A key aspect of ensuring safety for repositories located in low-permeability rock involves minimizing any damage to the rock itself, thereby preserving its integrity and promoting a stable environment Amongst a number of processes that could damage the rock is the increase in pore pressure due to thermal loading caused by heat emitted from the waste. To reduce the potential damage of the rock, it is important to analyse the evolution of heat over time due to the heat load of the containers and assess possible consequences by coupled THM models. The aim of Task C of DECOVALEX-2023 was to build 3D numerical models of the FE experiment, focussing in particular on the heating induced pore pressure change in the Opalinus Clay. Data from a large number of sensors were available from the FE experiment for model comparison. These sensors measured temperature and relative humidity in the bentonite around the heaters, and temperature, pressure and displacement/strain in the surrounding Opalinus clay. Data were available from the start of excavation (April 2012) up to August 2020 for most sensors (more than 5 years from the start of heating in December 2014). To fulfil the overall aim of the task, the work was broken down into a number of steps, starting with simpler models to build confidence in each team’s approach and then moving to more complex models that better represent the FE experiment. Step 0 consisted of 2D benchmark models, gradually increasing the number of processes that are represented from thermal (T) only models in Step 0a, to coupled thermal hydraulic (TH) models in Step 0b with a representation of changing porosity, to coupled thermo-hydro-mechanical (THM) models in Step 0c, where porosity changes are calculated by the mechanical model. A detailed specification of processes, parameters, initial and boundary conditions was provided for this step, with the ambition that all teams would work towards close agreement in their model results, thus building confidence in the model implementations. vi It was not straightforward to achieve agreement between the teams, so additional steps (Step 0b2, 0b3, 0c2, 0c3) were added along with derivation of some analytical solutions against which the models could be compared. The reasons for the differences between teams were investigated and found to be caused primarily by different conceptual model assumptions (including temperature dependence of the thermal expansion of water), different model formulations (including porosity evolution) and differences in modelled domain sizes, boundary conditions and grid discretisation. This demonstrates that comparisons between multiple modelling teams and/or comparison with analytical results and experimental data are highly beneficial in providing an indication of uncertainty in model predictions. At the conclusion of Step 0, almost all teams had achieved a close agreement in model results and those that had not achieved an agreement knew the reason for this. Step 1 moved from 2D models to 3D models of the FE experiment without adding technical features like shotcrete or EDZ, and only considering the heating phase. Initially the 3D model was tightly specified to continue to build confidence in the model implementations (Step 1a). The results of Step 1a were compared to the data from the FE-experiment without the teams seeing the data. The teams were then provided with a sub-set of the data from the FE-experiment and invited to consider how best to use the large dataset for model comparison (Step 1b). Teams were then asked to use the data provided to calibrate their models, only changing material property values rather than adding features or processes to their models (Step 1c). In Step 1, teams were asked to only model the heating phase of the experiment, so pressure in the Opalinus Clay was reported as change in pressure since the initial conditions were specified rather than modelled. The change from 2D to 3D models was accompanied by an increase in the dispersion of results between the teams. Some of this was resolved during the task, but some remained and is potentially due to model discretisation. Calibration of parameters was useful in improving the fit of the models to the data but the remaining differences indicated that the models were missing features or processes. In Step 2, the teams were asked to update their models with additional features and processes as well as calibrating parameters to try and improve the fit of the models to the data. Teams were encouraged to represent ventilation of the open FE tunnel prior to backfilling with heaters and bentonite and in Step 2, the absolute pressure in the Opalinus Clay was compared between the teams. Teams took different approaches, but there was consideration of adding shotcrete and an EDZ into the model, representing stress change during excavation and different approaches to modelling ventilation of the FE tunnel. Overall, the documented results showed a very good agreement for temperature. The results for porewater pressure evolution showed a significant improvement for most teams compared to Step 1c with a good agreement to the measurements for several teams whereas some teams overpredicted the pressure increase and others overpredicted the drainage effect especially for the sensors close to the heater. Step 3 was an opportunity for teams to use the models developed in Step 1 and Step 2 to make predictions about the temperature and pressure changes that will be expected at the FE experiment over the next few years in light of the planned changes in thermal output of the heaters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Tank 48H Treatment of Tetraphenylborate with Permanganate

Tank 48H contains roughly 270,000 gallons of radioactive waste material. The waste stored in this tank was to be processed in multiple stages utilizing facilities at the Savannah River Site (SRS) almost 30 years ago. The In-Tank Precipitation Process (ITP) was initiated in Tank 48H, which precipitated highly radioactive cesium-137 using sodium tetraphenylborate (NaTPB). While the process succeeded in precipitating the Cs, Sr, and other actinides, it also generated an unexpectedly large amount of benzene. The evolved benzene created a safety concern and made the waste incompatible with further downstream processing. This halted the ITP, and a new method of treatment was required to continue processing the legacy waste contained in Tank 48H. A myriad of treatment options have been proposed with multiple teams of researchers assembled to work on this highly complex issue over the last few decades. This review investigated one potentially viable treatment option, in-tank oxidation with sodium permanganate. Permanganate has been well known in literature as a strong oxidizing agent for organic compounds, as well as being utilized at the Savannah River Site (SRS) in other processes. A small number of studies have been conducted utilizing waste simulants to evaluate the use of permanganate as an oxidant for tetraphenylborate (TPB). A search of the literature and data from these studies indicates that permanganate could be a viable treatment for destruction of TPB in Tank 48H. While the scoping studies had a small number of individual experiments and nonideal conditions, the permanganate decomposed up to 90% of the TPB. A free hydroxide concentration above 1.0 M is required for tank corrosion control. Simulant studies indicate no decrease in TPB decomposition by permanganate until pH 14. The simulant studies show an increase in TPB decomposition as the temperature of the solution is increased to 40 °C. The post-reaction analysis of previous simulant tests did not look at all of the organic degradation products. Investigations into what these organic products are and in what quantity will help guide determinations as to whether the downstream processing facilities are able to handle the material that will be generated. Study on the time frame for the reaction between permanganate and TPB should be investigated as the literature reports only extend out to two weeks reaction time. The permanganate treatment conditions indicate no corrosion control concerns and a longer timescale reaction may be needed for in-tank treatment. In addition, further study would be useful to identify a lower boundary condition for the ratio of TPB and oxidant. The simulant tests applied large excesses of permanganate, and this may be unnecessary. The size constraint of the tank means that there will be practical limitations on the amount of sodium permanganate that can be added to the tank. The amount of permanganate should be minimized as much as possible while still ensuring decomposition of the TPB to minimize the amount of manganese dioxide solids generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS

The continental flood inundation mapping (CFIM) framework is a high-performance computing (HPC)-based computational framework for the Height Above Nearest Drainage (HAND)-based inundation mapping methodology. Using the 10m Digital Elevation Model (DEM) data produced by U.S. Geological Survey (USGS) 3DEP (the 3-D Elevation Program) and the NHDPlus hydrography dataset produced by USGS and the U.S. Environmental Protection Agency (EPA), a hydrological terrain raster called HAND is computed for HUC6 units in the conterminous U.S. (CONUS). The value of each raster cell in HAND is an approximation of the relative elevation between the cell and its nearest water stream. Derived from HAND, a hydraulic property table is established to calculate river geometry properties for each of the 2.7 million river reaches covered by NHDPlus (5.5 million kilometers in total length). This table is a lookup table for water depth given an input stream flow value. Such lookup is available between water depth 0m and 25m at 1-foot interval. The flood inundation map is then computed by using HAND and this lookup table based on the near real-time water forecast from the National Water Model (NWM) at the National Oceanic and Atmospheric Administration (NOAA). HAND and the Hydraulic Property Table version 0.2. is created to correspond to data updates in the USGS 1/3 arcsec DEM, the USGS National Hydrography Dataset, including its Water Boundary Dataset, and the NHDPlus medium resolution dataset. This dataset comprises 331 HUC6 units for CONUS (excluding the five great lakes units), each is a downloadable zip file. Version 0.1 was computed at the National Center for Supercomputing Applications (NCSA) at the University of Illinois at Urban-Champaign in 2016 and is currently hosted at the Texas Advanced Computing Center (TACC). Please cite this data DOI and the following publications and data DOIs when you use HAND and the hydraulic property table: Liu, Yan Y., David R. Maidment, David G. Tarboton, Xing Zheng, and Shaowen Wang. 'A CyberGIS integration and computation framework for high-resolution continental-scale flood inundation mapping.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 770-784. DOI: 10.1111/1752-1688.12660 Zheng, Xing, David G. Tarboton, David R. Maidment, Yan Y. Liu, and Paola Passalacqua. 'River channel geometry and rating curve estimation using height above the nearest drainage.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 785-806. DOI: 10.1111/1752-1688.12661 Liu, Y. (2018). Height Above Nearest Drainage (HAND) for CONUS - v0.1, HydroShare, https://doi.org/10.4211/hs.69f7d237675c4c73938481904358c789 LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

An Overview of Recent Cryogenic Fluid Management Developments

Long-term storage, supply, and transfer of cryogenic fluids are critical capabilities needed to advance the human exploration of space. Technologies and advanced development programs have been pursued to address issues likely to confront the designers and developers of future cryogenic fluid management (CFM) subsystems and propulsion systems. NASA and aerospace industries have continued to conduct research and development for the propulsion applications of cryogenic fluids. From the well known in-space applications, to new applications involving superconducting motors within multiple different aircraft, and a renewed interest in production of oxygen on Mars, NASA continues to probe cryogenic applications within propulsion. This article presents brief reviews of several of the current CFM efforts to support future space missions. NASA GRC is currently focusing on understanding some of the finer points in the application of multilayer insulation. GRC recently finished the activation of a new calorimeter that operates at 20 K with a warm boundary that can operate either around 90 K or at 300 K. Current testing is focused on investigating multiple different seam concepts, initially between temperatures of 300 K and 20 K, and between 20 K and 90 K. One of the larger recent NASA investments has been on the Structural Heat Intercept, Insulation, and Vibration Experiment Rig (SHIIVER). SHIIVER is a 4 m diameter tank that is approximately 1/2 scale of the planned upper stage of the new Space Launch System (SLS) rocket. SHIIVER is focused on demonstrating the thermal benefits of multilayer insulation on the tank domes and boil-off vapor cooling on structural cylinders that hold the tank in-line on the rocket. It will also quantify any damage that may incur during the acoustic environment of over 160 decibels that SLS will experience on its trip to Earth orbit. In support of the possible production of oxygen out of the Mars' atmosphere, a team comprised of four NASA centers (GRC, MSFC, JSC, and KSC) collaborated to investigate multiple different hardware combinations, refrigeration cycles, and integration techniques to minimize power and mass of the storage and liquefaction system. Moreover, high efficiency, high capacity cryocoolers are an element of CFM which is essential for achieving NASA's future long duration missions. Currently in development is a 20W at 20K unit for use with liquid hydrogen. It is scheduled for delivery to NASA in the summer of 2017. Two Phase I SBIRS have recently concluded resulting in the preliminary design of two different 90K units, each having a refrigeration capacity of approximately 150W. Once the development efforts are complete, these high capacity 90K units will be integrated into the design of NASA's Liquid Oxygen (LOX)/Methane applications such as the Lander and Ascent Vehicles, or possibly an in-space stage. CFM technology is critical to the success of missions to Mars, Planetary Exploration, and In-Situ Resource Utilization (ISRU) for cryogenic propellant production. NASA is focusing on the development of CFM technologies needed to provide necessary data and relevant experience to support informed decisions on implementation of design of cryogenic systems for long term space missions. Lessons learned from the described CFM developments would lead to enhanced safety and reliability and enabling technologies which could allow NASA to meet future space exploration goals.

Hedayat, A.↗

Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS - Version 0.21 (20200601)

The continental flood inundation mapping (CFIM) framework is a high-performance computing (HPC)-based computational framework for the Height Above Nearest Drainage (HAND)-based inundation mapping methodology. Using the 10m Digital Elevation Model (DEM) data produced by U.S. Geological Survey (USGS) 3DEP (the 3-D Elevation Program) and the NHDPlus hydrography dataset produced by USGS and the U.S. Environmental Protection Agency (EPA), a hydrological terrain raster called HAND is computed for HUC6 units in the conterminous U.S. (CONUS). The value of each raster cell in HAND is an approximation of the relative elevation between the cell and its nearest water stream. Derived from HAND, a hydraulic property table is established to calculate river geometry properties for each of the 2.7 million river reaches covered by NHDPlus (5.5 million kilometers in total length). This table is a lookup table for water depth given an input stream flow value. Such lookup is available between water depth 0m and 25m at 1-foot interval. The flood inundation map is then computed by using HAND and this lookup table based on the near real-time water forecast from the National Water Model (NWM) at the National Oceanic and Atmospheric Administration (NOAA). HAND and the Hydraulic Property Table version v0.21 is an upgrade to v0.2. Version 0.21 applies NHD HR etching to DEMs for all HUC6 units before running the HAND workflow. This new version also fixed the issue of void areas along HUC boundary. This dataset comprises 331 HUC6 units for CONUS (excluding the five great lakes units), each is a downloadable zip file. Version 0.1 was computed at the National Center for Supercomputing Applications (NCSA) at the University of Illinois at Urban-Champaign in 2016 and is currently hosted at the Texas Advanced Computing Center (TACC). Please cite this data DOI and the following publications and data DOIs when you use HAND and the hydraulic property table: Liu, Yan Y. Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS - Version 0.2. (20200301). Oak Ridge Leadership Computing Facility. (2020). DOI: 10.13139/ORNLNCCS/1608331 Liu, Yan Y., David R. Maidment, David G. Tarboton, Xing Zheng, and Shaowen Wang. 'A CyberGIS integration and computation framework for high-resolution continental-scale flood inundation mapping.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 770-784. DOI: 10.1111/1752-1688.12660 Zheng, Xing, David G. Tarboton, David R. Maidment, Yan Y. Liu, and Paola Passalacqua. 'River channel geometry and rating curve estimation using height above the nearest drainage.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 785-806. DOI: 10.1111/1752-1688.12661 Liu, Y. (2018). Height Above Nearest Drainage (HAND) for CONUS, HydroShare, https://doi.org/10.4211/hs.69f7d237675c4c73938481904358c789 LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗