Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls from the Tank 49H B4 downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. The scope of this task is to perform fluid flow analysis to determine the impact of a “plunging jet” through the B4 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF.

54 ENVIRONMENTAL SCIENCES↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Literature Review on the Impact of Thermolytic Hydrogen Generation Rate from the Next Generation Solvent

A literature review was undertaken to assess the thermolytic hydrogen generation potential of the Next Generation Solvent (NGS) system, which is planned to replace the Original Caustic-Side Solvent Extraction (CSSX) Solvent at the Salt Waste Processing Facility. NGS uses a new extractant and suppressor and the same modifier and organic carrier solvent as the Original CSSX Solvent at different concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of the Literature on the Radiolytic Stability of the Next-Generation Solvent

The Original Caustic-Side Solvent Extraction (CSSX) solvent (based on the BOBCalixC6 extractant) currently in use at the Salt Waste Processing Facility (SWPF) is set to be replaced by the Next-Generation Solvent (NGS, based on the MaxCalix extractant). Current SWPF flammability safety controls use G-values for volatile gases obtained from radiolysis studies with the Original CSSX solvent. A review of past irradiation tests of both solvent systems was performed to assess the radiolytic stability of NGS with respect to flammable gas generation from radiolysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Literature Review on Next Generation Solvent Isopar ® L Vapor Pressure Curve and the Partitioning of its Modifier and Extractant

The Next Generation Solvent (NGS) is set to replace the Original Caustic Side Solvent Extractant (CSSX) at the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC), formerly Savannah River Remediation (SRR), to perform a literature review on the following topics to address flammability concerns with the current solvent: Isopar ® L vapor pressure curve for NGS, partitioning ratio for the extractant MaxCalix and the modifier Cs-7SB, and high cesium concentration impacts on NGS radiolysis and potential solvent degradation rates in high cesium concentrations. The following conclusions and recommendations are made based on previous experimental work and literature: (1) Current SWPF flammable gas generation calculations use an Isopar ® L vapor pressure curve based on experimental testing with the Original CSSX solvent. No such testing to date has been performed with NGS. It is suggested that the decrease in Cs-7SB concentration for NGS compared to the Original CSSX solvent would lead to a slightly higher vapor pressure at all temperatures in SWPF vessels. A bounding NGS vapor pressure curve has been provided; it is recommended to see if these values would challenge current flammability controls and to perform testing if needed.(2) The partitioning ratio for Cs-7SB is known in the Original CSSX solvent with dilute nitric acid and caustic solutions. No tests could be found for the partitioning of Cs-7SB to dilute boric acid solutions; however, a similar partitioning ratio is expected. Due to the lipophilic alkyl chains on MaxCalix, it is expected to be even less soluble than BOBCalixC6 in the aqueous phase and should not be considered a significant contributor to the f organic term. Additionally, the reaction rate of N,N’,N’’-Tris(3,7-dimethyloctyl)guanidine (TiDG) or its degradation products with a hydrogen radical should be estimated/determined if they are found to be significant contributors to the f organic term. (3) NGS is expected to see much higher Cs concentrations at SWPF in comparison to its use at the Modular CSSX Unit (MCU). These higher Cs concentrations could influence radiolytic degradation rates of the solvent. NGS appears to be fairly stable to radiolytic degradation based on previous testing and its use at MCU. However, there has not been radiolytic flammable gas generation testing with NGS to date. There is a risk that the continued use of G-values obtained for flammable gases produced from the irradiation of the Original CSSX solvent is not bounding for NGS, but this is considered a very low risk due to the similarities in the composition of the solvents, as well as the conservatisms in the experimental design of the Original CSSX testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Analyses of the SRNL Solvent Components

At the request of the Savannah River Mission Completion (SRMC), personnel at Savannah River Site (SRS) performed analyses on the remaining solvent components that are being stored at the Savannah River National Laboratory (SRNL). This was done to determine if the remaining stock of materials were still suitable for use for the Salt Waste processing Facility (SWPF). Two drums of Modifier, two drums BOBCalix, four drums of MAXCalix, and four jars of TiDG*HCl were analyzed. All were found to be of acceptable purity for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H solids disturbance analysis

Tank 49H serves as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb any solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L of the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer could potentially disturb any solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine whether accounting for disturbed particle settling and particle mixing and dispersion during transfer could allow the minimum liquid level to be reduced below 120 inches. The analysis utilized models from the technical literature to calculate the size and shape of the “plunging jet” as a function of input parameters such as initial velocity, initial jet diameter, elevation of the initial jet, liquid level in the tank, and solids depth. The analysis relied on the M-Star® simulations performed for the previous analysis to provide bounding estimates of the amount of solid particles disturbed and used the MStar® software to calculate the dispersion and mixing of the disturbed solids with other liquid in the tank as the solids are transported to the transfer pump. The analysis showed that with a solid particle size of 5 micron or less, a liquid level of 120 inches should be maintained to prevent significant disturbance of the solid layer at the bottom of Tank 49H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Solvent Vapor Pressure Testing

Previous work by Savannah River National Laboratory (SRNL) indicated that the actual Next Generation Solvent vapor pressure would be higher than the Original Caustic Side Solvent Extraction (CSSX) solvent vapor pressure, but below a bounding vapor pressure using Raoult’s Law. Since solvent vapor pressure has a significant impact on Composite Lower Flammability Limits (CLFL) and attendant accident analyses, obtaining an additional margin from the bounding NGS vapor pressure would be valuable. In order to quantify how much margin might be gained from the NGS bounding solvent, SRNL researchers were requested to perform vapor pressure testing with the Next Generation Solvent (NGS) by Savannah River Mission Completion (SRMC). The vapor pressure curve for the NGS formulation set to be deployed at the Salt Waste Processing Facility (SWPF) has been determined by SRNL up to 55°C (131°F) using headspace Gas Chromatography (GC). It was expected that NGS would have a higher vapor pressure than the Original CSSX solvent; however, experimental results indicate a lower vapor pressure. At this time, it is uncertain if this difference is due to the 7x increase in concentration of the large calixarene in the solvent (0.007M BOBCalix in Original CSSX solvent vs. 0.05M MaxCalix in NGS) or to minor batch-to-batch variations in Isopar-L constituents. The NGS and the Original CSSX solvent vapor pressure data were fitted to the Antoine Equation. The Antoine equation gives a more accurate representation of the expected vapor pressure of the solvents outside of the temperature range tested. The Antoine equation fitting for NGS is given below: $P=10^{6.364⁻\frac{1788.4}{T+219.3}}$. Where, p is the vapor pressure (partial pressure) of NGS in mmHg and T is the temperature in °C. It is recommended that SRMC either continue using the more conservative Isopar-L vapor pressure calculations at SWPF with the equation developed for the Original CSSX solvent, or the equation presented above for the NGS solvent. Additionally, it is recommended to study the variability in Isopar-L vapor pressure between lots.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Compatibility of Tefzel™ and Viton™ B with Caustic-Side Solvent Extraction Solvents

The Salt Waste Processing Facility (SWPF) plans to switch from the current Caustic-Side Solvent Extraction (CSSX) solvent to the Next Generation Solvent-Phase II (NGS-Phase II). SRNL was requested to evaluate the compatibility between polymeric materials of construction at SWPF and NGS-Phase II solvent. The work presented here concentrated on two materials of interest: Tefzel™ and Viton™ B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the IBC BOBCalix Solvent Samples

A second vendor for solvent extraction components has been chosen for use at the Salt Waste Processing Facility (SWPF). IBC Advanced Technologies (IBC) has provided samples of their BOBCalix, as well as complete solvent. These samples were tested for quality assurance purposes to ensure their use at SWPF is acceptable. Two Extraction, Scrub, and Strip (ESS) tests were performed on solvent samples from IBC. The purpose of testing these samples was to determine if the solvents are displaying the correct extraction and stripping behavior with cesium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium Solubility and Supernate Enrichment Testing for Accelerated Basin De-Inventory Discards to Concentration, Storage, and Transfer Facilities

After future Accelerated Basin De-inventory (ABD) enriched uranium discards into sludge batches (SB), portions of supernate decants during SB preparation will be blended into salt batches (StB) and the resulting feeds must meet the nuclear safety requirements for the Salt Waste Processing Facility (SWPF). During previous SB10 sampling and testing, which involved H-Canyon material containing enriched uranium being mixed with Tank 51 sludge shortly after the H-Canyon stream was neutralized, it was identified that the uranium isotopic enrichment in the supernate deviated from the uranium isotopic enrichment in the slurry. The higher uranium isotopic enrichment in the supernate introduced the risk of challenging the feed requirements of SWPF. The ABD material added to SB11 was isotopically diluted with depleted uranium, mitigating any downstream impacts. However, H-Canyon desires to eliminate or minimize future depleted uranium additions in order to meet the mission schedule.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY24 Progress Report on Viscosity and Thermal Conductivity Measurements of Nuclear Industry Relevant Chloride Salts: An Experimental and Computational Study

As presented in this report, experimental and computational techniques were performed to assess the viscosity and thermal conductivity of key alkali and actinide chloride mixtures for molten salt reactor developers. These mixtures were pure LiCl, NaCl-KCl, LiCl-NaCl, LiCl-KCl, LiCl-NaCl-KCl, and NaCl-UCl 3 . Experimental measurements of viscosity were performed with a rolling ball viscometer, whereas experimental measurements of thermal conductivity were performed with a variable gap apparatus. Additional benchmarking work was performed using both property measurement systems to prepare for x-ray radiography in stainless-steel crucibles for viscosity and to ensure that calibration methods were accurate for thermal conductivity before assessing the NaCl-UCl 3 system. Validation data for the NaCl-UCl 3 in literature are minimal. Details on the calibration methods, salt measurement processes, and sources of error and uncertainty are discussed in detail for both property measurements. The computational methods described herein involved ab-initio molecular dynamics (AIMD) calculations using CP2K. The calculations were performed for the LiCl-KCl-NaCl and NaCl-UCl 3 systems. These calculations not only provided thermophysical property estimations for comparison to experimental data, but they also allowed for the determination of diffusion coefficients, coordination numbers, and radial distribution functions to provide insight into ion mobility and local coordination environments, which is linked to macroscopic property trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating Liquid Waste Transfers and their Impacts to the SRS Tank Farms to Support Operations and Closure

BACKGROUND • SRMC mission critical milestones – 34 million liters (9 million gallons) Salt Waste Processing Facility (SWPF) Processing Rate – Accelerated Waste Tank Closures • Results in an increase in Tank Farm transfers • Barriers – Equipment failures, replacements, and adjustments – Weather – Procedure development – Outside facility changes How has the Tank Farm adapted to meet these milestones? By improving the transfer evaluation process

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization, Leaching, and Filtration Testing for Bismuth Phosphate Sludge (Group 1) and Bismuth Phosphate Saltcake (Group 2) Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.() The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups—bismuth phosphate sludge (Group 1) and bismuth phosphate saltcake (Group 2)—are the subjects of this report. The Group 1 waste was anticipated to be high in phosphorus and was implicitly assumed to be present as BiPO4 (however, results presented here indicate that the phosphate in Group 1 is actually present as amorphous iron(III) phosphate). The Group 2 waste was also anticipated to be high in phosphorus, but because of the relatively low bismuth content and higher aluminum content, it was anticipated that the Group 2 waste would contain a mixture of gibbsite, sodium phosphate, and aluminum phosphate. Thus, the focus of the Group 1 testing was on determining the behavior of P removal during caustic leaching, and the focus of the Group 2 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.