Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Facile One-Pot Nanoproteomics for Label-Free Proteome Profiling of 50–1000 Mammalian Cells

Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combinatorial Multidomain Mesoporous Chips and a Method for Fractionation, Stabilization, and Storage of Biomolecules

A new fractionation device shows desirable features for exploratory screening and biomarker discovery. The constituent MSCs may be tailored for desired pore sizes and surface properties and for the sequestration and enrichment of extremely low abundant protein and peptides in desired ranges of the mass/charge spectrum. The MSCs are effective in yielding reproducible extracts from complex biological samples as small as 10 microliter in a time as short as 30 minutes. They are inexpensive to manufacture, and allow for scaled up production to attain the simultaneous processing of a large number of samples. The MSCs are multiplexed, label-free diagnostic tools with the potential of biological recognition moiety modification for enhanced specificity. The MSCs may store, protect and stabilize biological fluids, enabling the simplified and cost-effective collection and transportation of clinical samples. The MSC-based device may serve as a diagnostic tool to complement histopathology, imaging, and other conventional clinical techniques. The MSCs mediated identification of disease-specific protein signatures may help in the selection of personalized therapeutic combinations, in the real-time assessment of therapeutic efficacy and toxicity, and in the rational modulation of therapy based on the changes in the protein networks associated with the prognosis and the drug resistance of the disease.

Ferrari, Mauro↗

Freeform thermoelectrics in single-step manufacturing: additive manufacturing of bismuth-telluride thermoelectrics

The project succeeded in producing crack-free Bismuth Telluride thermoelectric parts with density exceeding 98% through laser powder bed fusion (LPBF) additive manufacturing (AM). This greatly exceeded the highest previously reported density of 88% and is the highest among all semiconducting materials processed by LPBF. The additively manufactured material shows comparable Seebeck coefficient as conventional form and can be made into complex geometries with reduced material loss. On the other hand, measured properties are dramatically sensitive to the AM process parameters used, such that with identical composition, the Seebeck coefficient can be controllably tuned from +120 µV/K to -207 µV/K, which means the material switches between an n-type to a p-type semiconductor depending on processing. These changes are accompanied by significant differences in the as-processed microstructure due to rapid solidification. A machine learning protocol was developed and greatly reduced the experimental burden of the project, reducing the typical process optimization period of 2 years to 6 months. The project was fully successful in the objective of producing defect-free, complex geometry of bismuth-telluride parts through LPBF, but only partially successful in achieving performance goals. First, cost reduction of manufacturing, as measured by material waste, was successfully reduced by up to 70% compared to conventional manufacturing methods. This exceeded the proposed 30% reduction in materials waste needed to reach the 20% cost reduction goal of the project. On the other hand, the device performance, as measured by Seebeck coefficient, failed to reach the 40% improvement in efficiency. Rather, we observe comparable Seebeck coefficient between AM samples and conventionally processed counterparts. The device-level efficiency improvement does exceed 40% for complex geometry samples due to shape-induced increase in temperature gradients, but this was not the originally proposed metric. The machine learning approach developed in this project greatly accelerated the process optimization and can be adopted for fast development of AM processing parameters for other brittle and otherwise difficult-to-print materials. For the public, we deliver an efficient and widely adoptable process for incorporating waste-heat harvesting thermoelectric devices in both industrial and commercial heat exchangers. The geometric flexibility allows the capturing device to conform to the shape of the heat source to improve the system-level conversion efficiency. The technique can be deployed on any commercial LBPF systems with zero modifications, thus poses minimal adoption barrier for any manufacturer that already employed AM technology. Beyond bismuth-telluride, the machine-learning guided optimization protocol can be used in the future to reduce both the time and cost of process development for AM of other energy conversion and harvesting materials.

36 MATERIALS SCIENCE↗

Significant Efficiency Enhancements in Non‐Y Series Acceptors by the Addition of Outer Side Chains

Abstract Most current highly efficient organic solar cells utilize small molecules like Y6 and its derivatives as electron acceptors in the photoactive layer. In this work, a small molecule acceptor, SC8‐IT4F, is developed through outer side chain engineering on the terminal thiophene of a conjugated 6,12‐dihydro‐dithienoindeno[2,3‐d:2′,3′‐d′]‐s‐indaceno[1,2‐b:5,6‐b′]dithiophene (IDTT) central core. Compared to the reference molecule C8‐IT4F, which lacks outer side chains, SC8‐IT4F displays notable differences in molecule geometry (as shown by simulations), thermal behavior, single‐crystal packing, and film morphology. Blend films of SC8‐IT4F and the polymer donor PM6 exhibit larger carrier mobilities, longer carrier lifetimes, and reduced recombination compared to C8‐IT4F, resulting in improved device performance. Binary photovoltaic devices based on the PM6:SC8‐IT4F films reveal an optimal efficiency over 15%, which is one of the best values for non‐Y type small molecule acceptors (SMAs). The resultant devices also show better thermal and operational stability than the control PM6:L8‐BO devices. SC8‐IT4F and its blend exhibit a higher relative degree of crystallinity and π coherence length, compared to C8‐IT4F samples, beneficial for charge transport and device performance. The results indicate that outer side chain engineering on existing small electron acceptors can be a promising molecular design strategy for further pursuing high‐performance organic solar cells.

He, Qiao [Department of Chemistry and Centre for P↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X ray analysis of balloon-collected particles erroneously considered as an October influx into the lower stratosphere

Individual particles were analyzed on the collection screens in a Jeolco scanning electron microscope using a Kevex Li-drifted silicon energy dispersive X ray detector. It was found that the bulk of the stratospheric samples studied comes from explosive squib devices. It is pointed out that this finding does not invalidate the extensive results obtained by Bigg et al. (1970, 1971) in previous sampling experiments.

Farlow, N. H.↗

In-flight friction and wear mechanism

A unique mechanism developed for conducting friction and wear experiments in orbit is described. The device is capable of testing twelve material samples simultaneously. Parameters considered critical include: power, weight, volume, mounting, cleanliness, and thermal designs. The device performed flawlessly in orbit over an eighteen month period and demonstrated the usefulness of this design for future unmanned spacecraft or shuttle applications.

Devine, E. J.↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

Nuclear Criticality Safety Program (NCSP)↗

Customized Science Carrier Modules and Accessories Developed for Microgravity Simulation Devices

Because the access to the true weightless environment of the ISS and other Low Earth Orbit (LEO) vehicles is limited and cost prohibitive, the need for ground-based microgravity simulation analogs to bridge the gravity continuum gap between 1g gravity and costly space flight studies with true weightlessness was realized. As such, the Microgravity Simulation Support Facility (MSSF) was established at NASA John F. Kennedy Space Center (KSC) to fulfill the need of the scientific community. Our facility provides the US science community with a focal point in the field of gravitational research by granting access to an array of two-dimensional(2D) and three-dimensional (3D)clinostats, and Random Positioning Machine (RPM) platforms developed by teams throughout the world. The availability of these capabilities will allow further understanding the role of altered gravity vectors from “functional weightlessness”, partial gravity conditions (1 x 10-3to 0.9g, and Moon and Mars ‘g vectors), to hypergravity (up to3g) on biological processes. We have designed and 3D printed a variety of specialized attachments(and associated “static control” hardware)to allow researchers to mount their samples onto these microgravity simulation devices to meet their unique science requirements. A summary of each attachment module will be presented below. Note: All software or code information should be requested to the author Ye Zhang, Kennedy Space Center ye.zhang-1@nasa.gov

Ye Zhang↗

Observation of tantalum deposition and growth on TiB2 and ZrB2 from PISCES-RF deuterium and helium plasma exposures

Deuterium and helium plasma exposures on bulk TiB2 and ZrB2 samples were performed using the PISCES-RF linear plasma device. 40 and 90 eV deuterium ion plasma exposures were performed at 240 and 800 °C sample temperatures, and 80 eV helium ion plasma exposures were performed at 800 °C sample temperatures. Following plasma exposures, it was discovered that two plasma conditions (90 eV deuterium and 80 eV helium at 800 °C) resulted in thick (>200 nm) tantalum-rich (>10 at%) surface features on the targets, presumably from tantalum sourced from a tantalum adapter mask or cap used as part of the target holder. This work aims to characterize these tantalum-rich features and examine the mechanisms of impurity deposition.Plasma-induced surface morphology of the tantalum-rich surface layers depends on plasma properties and target temperature and chemistry. Greater titanium sputtering compared to zirconium resulted in more distinct surface features in the TiB2 samples compared to the ZrB2 samples via increased, prompt deposition onto tantalum surface impurities. There is still uncertainty as to why thick tantalum deposition only occurred under some plasma exposure conditions but not others; it is likely due to tantalum sputtering by a combination of boron molecules from the targets and carbon-impurities in the tantalum mask or targets. Impurity driven surface features are a well-documented phenomena in samples exposed to plasma from linear plasma device facilities—this work confirms the occurrence of this and emphasizes the need for chemistry characterization of isolated post-mortem surface features in plasma-exposed samples.

Nuckols, Lauren↗

Warm Pressurant Gas Effects on the Liquid Hydrogen Bubble Point

This paper presents experimental results for the liquid hydrogen bubble point tests using warm pressurant gases conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device. Three fine mesh screen samples (325 x 2300, 450 x 2750, 510 x 3600) were tested in liquid hydrogen using cold and warm noncondensible (gaseous helium) and condensable (gaseous hydrogen) pressurization schemes. Gases were conditioned from 0 to 90 K above the liquid temperature. Results clearly indicate a degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over noncondensible pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Liquid Hydrogen↗

Fidelity Analysis of Sampled Imaging Systems

Many modeling, simulation and performance analysis studies of sampled imaging systems are inherently incomplete because they are conditioned on a discrete-input, discrete-output model that only accounts for blurring during image acquisition and additive noise. For those sampled imaging systems where the effects of digital image acquisition, digital filtering and reconstruction are significant, the modeling, simulation and performance analysis should be based on a more comprehensive continuous-input, discrete-processing, continuous-output end-to-end model. This more comprehensive model should properly account for the low-pass filtering effects of image acquisition prior to sampling, the potentially important noiselike effects of the aliasing caused by sampling, additive noise due to device electronics and quantization, the generally high-boost filtering effects of digital processing, and the low-pass filtering effects of image reconstruction. This model should not, however, be so complex as to preclude significant mathematical analysis, particularly the mean-square (fidelity) type of analysis so common in linear system theory. We demonstrate that, although the mathematics of such a model is more complex, the increase in complexity is not so great as to prevent a complete fidelity-metric analysis at both the component level and at the end-to-end system level: that is, computable mean-square-based fidelity metrics are developed by which both component-level and system-level performance can be quantified. In addition, we demonstrate that system performance can be assessed qualitatively by visualizing the output image as the sum of three component images, each of which relates to a corresponding fidelity metric. The cascaded, or filtered, component accounts for the end-to-end system filtering of image acquisition, digital processing, and image reconstruction; the random noise component accounts for additive random noise, modulated by digital processing and image reconstruction filtering; and the aliased noise component accounts for the frequency folding effect of sampling, modulated by digital processing and image reconstruction filtering.

Park, Stephen K.↗

Developing a Tool to Collect Microbiological Samples in Space

We developed and tested a tool to collect aseptic samples during extravehicular activity or space walks. This tool can withstand the extreme temperature (-92 – 90 ˚C) and pressure variations without compromising the sterility of the collection device or the integrity of the sample. Results from ground testing the tool demonstrate that external surfaces of space suits are not sterile and that a wide variety of human associated bacteria and some fungi can survive at least seven hours of exposure to vacuum. These bacteria include non-spore forming organisms like Staphylococcus that are not normally considered extremophiles We plan to use this tool to characterize the exterior of the International Space Station. We expect the results of this work to guide the planetary protection requirements and contamination control strategy for crewed missions to Mars. This tool could also be used to monitor contamination associated with the Artemis missions to the moon or collect aseptic samples robotically in environments that are not suitable for human exploration.

A B Regberg↗