Search NASA⌕ Search

SEARCH · Search NASA

Results for “ScO2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Approaches for Water Removal in Direct-Fired sCO 2 Power Cycles

There is interest in investigation of water removal processes in direct fired sCO 2 flows, as this may potentially lead to greater system efficiency as the removal of this contaminant will result in sCO 2 behaving close to idealized behaviors. Water removal should be split into a two-step process, condensation of the water, followed by separation of the liquid phase water from the sCO 2 . The two main avenues of condensation are manipulation of pressure and temperature for phase change. For this paper, temperature-based phase change is the primary focus through the implementation of heat exchangers. Of the heat exchangers investigated it was found that printed circuit heat exchangers (PCHEs) could be an alternative for this use case, though the specific design of flow channel geometry and flow direction depends on the specific system case and cannot be determined at this point. For water separation there were four processes identified, all of which already assume water is in liquid phase at that point in the system. Of these separation avenues the best candidate is the hydrocyclone as it has a proven history of separating liquid-liquid phase mixtures with small density differences in oilfield use, in addition they have been investigated and modeled specifically for water separation for sCO 2 flows and the footprint is relatively small.

20 FOSSIL-FUELED POWER PLANTS↗

Performance and Cost Assessment of a Natural Gas-Fueled Direct sCO 2 Power Plant

This final report details the cost and performance baseline developed at NETL for a natural gas-fueled direct sCO 2 plant, which holds promise as an efficient, cost-effective method of power production with carbon capture and storage (CCS). The steady state plant model includes turbine cooling flows based on a semi-empirical cooling model, and thermal integration with the air separation unit and oxygen compression train. Discussion of the performance of the baseline plant design is followed by details on the costing methodology, overall plant capital cost, and resulting cost of electricity (COE). Performance results yield a baseline sCO 2 plant thermal efficiency of 48.2% (HHV) with 98.2% carbon capture, an improvement over the reference NGCC plant with CCS (45.7% and 90.7% carbon capture). Cost analyses yield a 5% reduction in COE versus the NGCC plant, albeit with significant uncertainty. Finally, the effects of incomplete combustion on the overall plant performance are assessed.

03 NATURAL GAS↗

Supercritical Carbon Dioxide (SCO 2 ) Cycle as an Efficiency Improvement Opportunity for Air-fired Coal Combustion

Coal has been historically the fuel to satisfy the United States’ need for baseload electricity generation. Increasingly stringent environmental regulations (specifically uncertainty for CO 2 emission regulations), are forcing the electric power industry to scrutinize the long-term viability of new and existing coal-fueled assets. The development of advanced, higher efficiency coal power generation technologies leading to reductions in CO 2 and other emissions and competitive costs are one avenue to address these concerns. A goal of this study was initially to identify one or more conceptual designs for a coal-fired power plant that could meet the existing “Carbon Pollution Standard (CPS) for New Power Plants” without dedicated CO 2 capture equipment. Since the EPA proposals are still under the review process, this report uses the current limits. Additional goals include: sCO 2 cycles systems that achievie an efficiency > 46.7 % HHV and a cost of electricity of < $82.3/MWh.

01 COAL, LIGNITE, AND PEAT↗

Adiabatic Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for an adiabatic cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Direct Dry Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Gen3 Gas Phase System Development and Demonstration (Final Technical Report)

Work undertaken in this project seeks to transform the current baseline technology – which is a collection of related but separately developed components and concepts – into a unified and operating test facility and an accompanying preliminary commercial design. This project is motivated by the primary goal of developing a system to absorb concentrated solar energy and deliver it into thermal energy storage at temperatures above 700°C, thereby enabling integration with a high-efficiency supercritical carbon dioxide (sCO 2 ) power cycle to achieve or exceed a levelized cost of electricity (LCOE) target of 6 ¢ per kilowatt-hour electric (kW e -hr). The proposed baseline solution utilizes a high-temperature gas phase (GP) system interfacing with a two-tank particle thermal energy storage (TES) and intermediate heat exchangers to supply sCO 2 at 20-25 megapascals (MPa) and 700°C at the turbine inlet.

14 SOLAR ENERGY↗

High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines (Final Report)

This is the final report for project DE-FE0031924 titled “High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines.” The report provides a summary of the entire project efforts from October 2020 through December 2024 including the high-temperature commercial dry gas seal (DGS) tests and thermal modeling of Task 2, as well as the high-temperature, large-diameter seal design and high-temperature tests of large-diameter seals in Task 3. A key outcome of Task 2 was the testing completion of specially instrumented commercial DGS in the GE-SwRI Apollo sCO 2 compressor (27,000 rpm). Test data from the DGS showed elevated temperatures upwards of 350 o F, which are close to the higher operating temperature limit of the DGS. The temperature measurements provide insight into the expected thermal loads on DGS operating in high-speed sCO 2 compressor and provided test data for validation of an in-house thermal model of the compressor/seal. Under Task 2.0, this report also presents the development of a steady-state conjugate heat-transfer model of the DGS operating in the sCO 2 compressor – a first of its kind model for modeling heat transfer of sCO 2 in an actual operating compressor. The findings of the thermal model show a reasonable match between temperature predictions of the model and the measured temperature data, also pointing out the validity of the approach and assumptions made in modeling the flows, heat transfer coefficients and windage modeling in the rig. Under Task 3.0, this report presents the preliminary design of a large-diameter hybrid face seal (14 inch and 26-inch diameter) for field testing in a land-based GE turbine. The preliminary seal design effort presented in this report under project DE-FE0031924 builds on the development and successful laboratory testing for such large diameter hybrid face seal under the prior DE-FE0024007 project. Key aspects of seal fluid analyses with CFD, mechanical design considerations and assembly considerations in a land-based turbine are presented. Finally, under Task 3.0, this report also presents the continued high-temperature testing of the 14-inch diameter hybrid face seal developed previously under the DE-FE0024007 program. Specifically, test data demonstrating successful non-contact seal operation and seal effective leakage of 0.001-inch with seal inlet temperatures above 700 o F are presented in this report. Successful hybrid seal operation in a laboratory environment for a large diameter (14-inch) seal at temperatures above 700 o F is a major technological milestone for this technology.

01 COAL, LIGNITE, AND PEAT↗

Design and dynamic modeling of printed circuit heat exchangers for supercritical carbon dioxide Brayton power cycles

Due to the unique geometries and hydraulics of printed circuit heat exchangers and rapidly changing properties of supercritical carbon dioxide, the effective design and rating of printed circuit heat exchangers is an essential requirement for their use in supercritical carbon dioxide power cycles. In this study, one-dimensional design and dynamic models have been developed in Aspen Custom Modeler for printed circuit heat exchangers utilized in printed circuit heat exchangers Brayton power cycles. The design model is used to determine the optimal geometry parameters by minimizing the metal mass. The dynamic model is used to predict transient behavior and can be easily implemented into system-level models developed in Aspen Plus Dynamics for cycle performance evaluations. In these models, the heat transfer coefficient and friction factor are calculated using data reported by Heatric, a prominent printed circuit heat exchanger manufacturer. Both models are validated by comparing with the data from a small-scale exchanger used in the 100 kWe facility operated by the Naval Nuclear Laboratory, and then applied to design and simulate low- and high-temperature recuperators for a 10 MWe supercritical carbon dioxide indirect recompression closed Brayton cycle, which is of interest to the U.S. Department of Energy. The designs and dynamic responses of the printed circuit heat exchangers are compared with conventional shell-and-tube exchangers and microtube shell-and-tube exchangers for the same applications. Here, the simulation results indicate that the proposed printed circuit heat exchangers have fast dynamic responses due to their small metal masses and high heat transfer coefficients compared with the conventional shell-and-tube exchangers. Even though the metal masses of the designed PCHEs are slightly higher than those of the microtube shell-and-tube exchangers, the printed circuit heat exchangers are still promising candidates for heat recuperation because of their mature manufacturing procedures and abundant laboratory and industrial operating experience.

42 ENGINEERING↗

Thermal hydraulic characteristics of liquid sodium and supercritical CO 2 in a diffusion bonded heat exchanger

Compact heat exchangers are being examined for use in advanced, high-temperature nuclear or concentrated solar power plants to improve thermal efficiencies and reduce capital costs. At the time of this work, no experimental investigation of liquid sodium in the popular diffusion-bonded heat exchanger design had been performed. Herein this paper describes the thermal-hydraulic and overall operations performance observed during testing of a 316/L stainless steel “zig-zag” microchannel heat exchanger operating between a (0.5 kg/s) sodium loop and a (0.3 kg/s) recuperated supercritical CO 2 system with outlet conditions up to 550 °C at 16 MPa. Observed pressure drop is presented in the form of an effective friction factor correlation which aligns closely with recent experimental data. The thermal performance of this heat exchanger, measured by its overall conductance under various flow conditions, was decomposed to examine the independent convection behaviors of both the CO 2 and sodium streams. These results are presented in the form of Nusselt correlations fitted to the experimental data. The sodium heat transfer correlation aligns closely with the widely accepted Lubarsky-Kaufman correlation, while the CO 2 heat transfer correlation lies between previous correlations developed by computational and experimental methods. This was the first long-duration use of sodium in a microchannels (~1.8 mm hydraulic diameter) heat exchanger. The use of an oxide control system enabled trouble-free operation of the heat exchanger for over 150 h of high-temperature operation. This first-of-a-kind demonstration using liquid sodium and supercritical carbon dioxide shows great promise for further application of this technology in advanced nuclear or solar power plants.

42 ENGINEERING↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Physics-Informed Deep Learning-Based Proof-of-Concept Study of a Novel Elastohydrodynamic Seal for Supercritical CO 2 Turbomachinery

Supercritical carbon dioxide (sCO 2 ) power cycles show promising potential of higher plant efficiencies and power densities for a wide range of power generation applications such as fossil fuel power plants, nuclear power production, solar power, and geothermal power generation. sCO 2 leakage through the turbomachinery has been one of the main concerns in such applications. To offer a potential solution, we propose an elastohydrodynamic (EHD) seal that can work at elevated pressures and temperatures with low leakage and minimal wear. The EHD seal has a very simple, sleeve-like structure, wrapping on the rotor with minimal initial clearance at micron levels. Here, in this work, a proof-of-concept study for the proposed EHD seal was presented by using the simplified Reynolds equation and Lame’s formula for the fluid flow in the clearance and for seal deformation, respectively. The set of nonlinear equations was solved by using both the conventional Prediction–Correction (PC) method and modern Physics-Informed Neural Network (PINN). It was shown that the physics-informed deep learning method provided good computational efficiency in resolving the steep pressure gradient in the clearance with good accuracy. The results showed that the leakage rates increased quadratically with working pressures and reached a steady-state at high-pressure values of 15~20 MPa, where Q = 300 g/s at 20 MPa for an initial seal clearance of 255 μm. This indicates that the EHD seal could be tailored to become a potential solution to minimize the sCO 2 discharge in power plants.

30 DIRECT ENERGY CONVERSION↗

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Closed Loop Geothermal Working Group: GeoCLUSTER App, Subsurface Simulation Results, and Publications

To better understand the heat production, electricity generation performance, and economic viability of closed-loop geothermal systems in hot-dry rock, the Closed-Loop Geothermal Working Group -- a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed-loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and supercritical CO2) while varying seven continuous independent parameters of interest (mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying Python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the techno-economic analysis script are provided. This data submission will contain results from the Closed Loop Geothermal Working Group study that are within the public domain, including publications, simulation results, databases, and computer codes. GeoCLUSTER is a Python-based web application created using Dash, an open-source framework built on top of Flask that streamlines the building of data dashboards. GeoCLUSTER provides users with a collection of interactive methods for streamlining the exploration and visualization of an HDF5 dataset. The GeoCluster app and database are contained in the compressed file geocluster_vx.zip, where the "x" refers to the version number. For example, geocluster_v1.zip is Version 1 of the app. This zip file also contains installation instructions. **To use the GeoCLUSTER app in the cloud, click the link to "GeoCLUSTER on AWS" in the Resources section below. To use the GeoCLUSTER app locally, download the geocluster_vx.zip to your computer and uncompress this file. When uncompressed this file comprises two directories and the geocluster_installation.pdf file. The geo-data app contains the HDF5 database in condensed format, and the GeoCLUSTER directory contains the GeoCLUSTER app in the subdirectory dash_app, as app.py. The geocluster_installation.pdf file provides instructions on installing Python, the needed Python modules, and then executing the app.

15 GEOTHERMAL ENERGY↗

High-Efficiency Low-Cost Solar Receiver for Use Ina a Supercritical CO 2 Recompression Cycle

This project has performed solar receiver designs for two supercritical carbon dioxide (sCO 2 ) power cycles. The first half of the program focused on a nominally 2 MWe power cycle, with a receiver designed for test at the Sandia Solar Thermal Test Facility. This led to an economical cavity-type receiver. The second half of the program focused on a 10 MWe power cycle, incorporating a surround open receiver. Rigorous component life and performance testing was performed in support of both receiver designs. The receiver performance objectives are set to conform to the US DOE goals of 6¢/kWh by 2020 . Key findings for both cavity-type and direct open receiver are highlighted below: A tube-based absorber design is impractical at specified temperatures, pressures and heat fluxes for the application; a plate-fin architecture however has been shown to meet performance and life targets; the $148/kW th cost of the design is significantly less than the SunShot cost target with a margin of 30%; the proposed receiver design is scalable, and may be applied to both modular cavity-type installations as well as large utility-scale open receiver installations; the design may be integrated with thermal storage systems, allowing for continuous high-efficiency electrical production during off-sun hours; costs associated with a direct sCO 2 receiver for a sCO 2 Brayton power cycle are comparable to those of a typical molten salt receiver; lifetimes in excess of the 90,000 hour goal are achievable with an optimal cell geometry; the thermal performance of the Brayton receiver is significantly higher than the industry standard, and enables at least a 30% efficiency improvement over the performance of the baseline steam-Rankine boiler/cycle system; brayton’s patent-pending quartz tube window provides a greater than five-percent efficiency benefit to the receiver by reducing both convection and radiation losses.

14 SOLAR ENERGY↗

FY2017 Sodium-CO2 Interaction Tests

An experimental campaign was carried out in Fiscal Year 2017 in the ANL SNAKE facility that investigated the interaction between sCO 2 and sodium through injection of sCO 2 into a sodium-filled diffusion-bonded heat exchanger channel mock-up. This successful experiment demonstrated that a sustained chemical reaction between the injected CO 2 and sodium occurred at temperatures representative of the cold leg of an intermediate heat transport system for a SFR-to-sCO 2 Brayton Cycle energy conversion system. Evidence of the chemical reaction included: exothermic heatup of localized regions of the test vessel, production of carbon monoxide, consumption of CO 2 and production of solid reaction products that were observed during post-test examination. This experimental result was consistent with previous SNAKE experiments. Two of fourteen previous SNAKE tests confirmed that self-plugging of the leakage path/nozzle could occur at higher initial s odium temperatures due to chemical reactions involving CO 2 , sodium, and sodium-CO 2 reaction products. The remaining tests, including the one carried out in Fiscal Year 2017, began with low er initial temperatures and did not self-plug. A new model was developed to determine the reaction rate constant for sCO 2 injections into sodium by calculating the increase of bulk sodium temperature. This model will be developed further and used to simulate the behavior of reactor-scale sodium-to-sCO 2 heat exchanger failures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗