Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scan Mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Neutral Ion Figuring of Chemical Vapor Deposited SiC

Ion figuring of optical components is a relatively new technology that can alleviate some of the problems associated with traditional contact polishing. Because the technique is noncontacting, edge distortions and rib structure print through do not occur. This investigation was aimed at determining the effect of ion figuring on surface roughness of previously polished or ductile ground ceramic optical samples. This is the first step in research directed toward the combination of a prefinishing process (ductile grinding or polishing) with ion figuring to produce finished ceramic mirrors. Multiple, chemical vapor deposited silicon carbide (CVD SiC) samples were polished or ductile ground to specular or near-specular roughness. These samples were then characterized to determine topographic surface information. The surface evaluation consisted of stylus profilometry, interferometry, and optical and scanning electron microscopy. The surfaces were then ion machined to depths from 0 to 5 micron. The finished surfaces were characterized to evaluate the effects of the ion-machining process with respect to the previous processing methods and the preexisting subsurface damage. This study provides some of the information required to effectively utilize a combined ductile grinding or polishing with ion machining as a procedure for figuring optical components.

Fawcett, Steven C.↗

Analytical and Experimental Characterization of a Linear-Array Thermopile Scanning Radiometer for Geo-Synchronous Earth Radiation Budget Applications

The Thermal Radiation Group, a laboratory in the department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently working towards the development of a new technology for cavity-based radiometers. The radiometer consists of a 256-element linear-array thermopile detector mounted on the wall of a mirrored wedgeshaped cavity. The objective of this research is to provide analytical and experimental characterization of the proposed radiometer. A dynamic end-to-end opto-electrothermal model is developed to simulate the performance of the radiometer. Experimental results for prototype thermopile detectors are included. Also presented is the concept of the discrete Green's function to characterize the optical scattering of radiant energy in the cavity, along with a data-processing algorithm to correct for the scattering. Finally, a parametric study of the sensitivity of the discrete Green's function to uncertainties in the surface properties of the cavity is presented.

Sorensen, Ira J.↗

Development and Operations of the Astrophysics Data System

The ADS was represented at the AAS meeting with 3 poster papers and a demonstration booth. We have setup a mirror site of the Vizier data base system at the CDS. functionality of the ADC at Goddard. This will replace the Preparations for the APS and LPSC meetings in March started. We will have demonstrations at both meetings. Preparations for the APS and LPSC meetings in March continued. We will have demonstrations at both meetings. The ADS was represented with a poster at the joint AGUEGU meeting in Nice, France. Discussions about the on-going collaboration between the ADS and the CDS in Strasbourg, France were held in Strasbourg. The ADS was invited to organize a session about the ADS and its mirror sites at the next United Nations Workshop on Basic Space Sciences in the Developing World. Efforts are under way to enter the tables of contents of all conference proceedings in the SA0 library into the ADS. This requires copying the tables of contents from all volumes in the library and have them typed in. This will greatly enhance the coverage of the literature in the ADS. We started the development of a search system for the full text of all scanned material in the ADS. This will eventually allow our users search capabilities that so far do not exist in any form. I order to enable the full text searching, we have purchased OCR software and are in the process of OCRing the scanned pages in the ADS. Efforts are in progress to handle the inclusion of data set identifiers in article manuscripts. The ADS will be the central system that will allow the journals to verify data set identifiers. The "master verifier" has been implemented in prototype form at the ADS. We started to include more journals in Geosciences/Geophysics in the ADS. The Royal astronomical Society has decided to archive their on-line journals in the ADS three years after publication. We have started to process these older on-line articles in order to archive them in the ADS. Our mirror site in Korea now has a full article mirror. We developed XML output capability in the ADS. This will make it easier to exchange data with other data systems. We started the development of new indexing software that will eventually reduce the indexing time for a database from days to hours or less. The ADS was represented at the IAU General Assembly with a poster. Discussions with the IAU management were held about extending the ADS IAU collaborations.

Murray, Stephen S.↗

Scanning Laser Infrared Molecular Spectrometer (SLIMS)

This prototype innovation is a novel design that achieves very long, effective laser path lengths that are able to yield ppb (parts per billion) and sub-ppb measurements of trace gases. SLIMS can also accommodate multiple laser channels covering a wide range of wavelengths, resulting in detection of more chemicals of interest. The mechanical design of the mirror cell allows for the large effective path length within a small footprint. The same design provides a robust structure that lends itself to being immune to some of the alignment challenges that similar cells face. By taking a hollow cylinder and by cutting an elliptically or spherically curved surface into its inner wall, the basic geometry of a reflecting ring is created. If the curved, inner surface is diamond-turned and highly polished, a surface that is very highly reflective can be formed. The surface finish can be further improved by adding a thin chrome or gold film over the surface. This creates a high-quality, curved, mirrored surface. A laser beam, which can be injected from a small bore hole in the wall of the cylinder, will be able to make many low-loss bounces around the ring, creating a large optical path length. The reflecting ring operates on the same principle as the Herriott cell. The difference exists in the mirror that doesn't have to be optically aligned, and which has a relatively large, internal surface area that lends itself to either open air or evacuated spectroscopic measurements. This solid, spherical ring mirror removes the possibility of mirror misalignment caused by thermal expansion or vibrations, because there is only a single, solid reflecting surface. Benefits of the reflecting ring come into play when size constraints reduce the size of the system, especially for space missions in which mass is at a premium.

Scott, David C.↗

Fabrication of optical components for the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

The Solar Maximum Mission (SMM) satellite was launched in February 1980 into a 573 km high circular orbit. It contains X-ray, UV, and optical instruments for the simultaneous observation of solar flares. The ultraviolet spectrometer and polarimeter (UVSP) is one of these instruments. The objectives of the UVSP require the employment of a raster scanning telescope to study the spatial dynamics of flares, the use of a high resolution spectrometer to select and scan spectral lines for temperature and velocity diagnostics, and the utilization of a polarimeter to measure magnetic fields in the solar transition zone. The present paper has the objective to provide a description of the optical fabrication techniques developed for the instrument. Attention is given to telescope mirrors, metering rods, the Ebert mirror, grating blanks, a four-mirror polarizer, beam splitter assemblies, beam splitter fabrication, deflector mirrors, and shipping containers.

Spencer, R. S.↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

MODIS Reflective Solar Bands On-Orbit Calibration and Performance

The design of the MODIS instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (1 km) with a comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 m collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the solar diffuser stability monitor (SDSM) provide a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudo-invariant desert sites are used to characterize the response versus scan- angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror side dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared to Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during post-launch operations. As the instruments age and continue to endure the space environment, the detectors and optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.

solar diffuser stability monitor↗

Baffle design for earth radiation rejection in the Cryogenic Limb-Scanning Interferometer/Radiometer

The Cryogenic Limb-Scanning Interferometer/Radiometer (CLIR) is being developed to observe infrared emissions of the earth's upper atmosphere from space. The earth's surface is an extended source of intense background radiation with a small angular separation from the desired scene. The CLIR employs an off-axis Gregorian Telescope whose primary mirror and baffles are cooled by an open-cycle cryogen system. A system of specular annular baffles has been developed to minimize both stray light problems and cryogen consumption by retro-mapping the aperture into itself. Each off-axis ray which enters the aperture and strikes the specular baffle surface is reflected so that it passes out of the aperture and is not absorbed on a cryogenic surface. The specular baffle which lies closest to the aperture is an ellipsoid whose foci trace out the circular aperture on revolution about the axis. Its theoretical 'ray trace' efficiency is 100 percent. A subsequent baffle has an elliptical cross section whose near focus traces out the central hole in the ellipsoidal baffle and whose far focus traces out the aperture. Its theoretical efficiency is about 90 percent. These baffles reduce the earth radiation heat load on the cryogenic cooler by an order of magnitude, changing it from the dominant cause of cryogen consumption to a relatively small effect. An aperture shield is also desirable to reduce cryogen consumption, stray light, and contamination.

Bremer, J. C.↗

Radar Observations of Convective Systems from a High-Altitude Aircraft

Reflectivity data collected by the precipitation radar on board the tropical Rainfall Measuring Mission (TRMM) satellite, orbiting at 350 km altitude, are compared to reflectivity data collected nearly simultaneously by a doppler radar aboard the NASA ER-2 flying at 19-20 km altitude, i.e. above even the deepest convection. The TRMM precipitation radar is a scanning device with a ground swath width of 215 km, and has a resolution of about a4.4 km in the horizontal and 250 m in the vertical (125 m in the core swath 48 km wide). The TRMM radar has a wavelength of 217 cm (13.8 GHz) and the Nadir mirror echo below the surface is used to correct reflectivity for loss by attenuation. The ER-2 Doppler radar (EDOP) has two antennas, one pointing to the nadir, 34 degrees forward. The forward pointing beam receives both the normal and the cross-polarized echos, so the linear polarization ratio field can be monitored. EDOP has a wavelength of 3.12 cm (9.6 GHz), a vertical resolution of 37.5 m and a horizontal along-track resolution of about 100 m. The 2-D along track airflow field can be synthesized from the radial velocities of both beams, if a reflectivity-based hydrometer fall speed relation can be assumed. It is primarily the superb vertical resolution that distinguishes EDOP from other ground-based or airborne radars. Two experiments were conducted during 1998 into validate TRMM reflectivity data over convection and convectively-generated stratiform precipitation regions. The Teflun-A (TEXAS-Florida Underflight) experiment, was conducted in April and May and focused on mesoscale convective systems mainly in southeast Texas. TEFLUN-B was conducted in August-September in central Florida, in coordination with CAMEX-3 (Convection and Moisture Experiment). The latter was focused on hurricanes, especially during landfall, whereas TEFLUN-B concentrated on central; Florida convection, which is largely driven and organized by surface heating and ensuing sea breeze circulations. Both TEFLUN-A and B were amply supported by surface data, in particular a dense raingauge network, a polarization radar, wind profilers, a mobile radiosonde system, a cloud physics aircraft penetrating the overflown storms, and a network of 10 cm Doppler radars(WSR-88D). This presentation will show some preliminary comparisons between TRMM, EDOP, and WSR-88D reflectivity fields in the case of an MCS, a hurricane, and less organized convection in central Florida. A validation of TRMM reflectivity is important, because TRMM's primary objective is to estimate the rainfall climatology with 35 degrees of the equator. Rainfall is estimated from the radar reflectivity, as well from TRMM's Microwave Imager, which measures at 10.7, 19.4, 21.3, 37, and 85.5 GHz over a broader swath (78 km). While the experiments lasted about three months the cumulative period of near simultaneous observations of storms by ground-based, airborne and space borne radars is only about an hour long. Therefore the comparison is case-study-based, not climatological. We will highlight fundamental differences in the typical reflectivity profiles in stratiform regions of MCS's, Florida convection and hurricanes and will explain why Z-R relationships based on ground-based radar data for convective systems over land should be different from those for hurricanes. These catastrophically intense rainfall from hurricane Georges in Hispaniola and from Mitch in Honduras highlights the importance of accurate Z-R relationships, It will be shown that a Z-R relationship that uses the entire reflectivity profile (rather than just a 1 level) works much better in a variety of cases, making an adjustment of the constants for different precipitation system categories redundant.

Heymsfield, G.↗

The Defects Genome of Janus Transition Metal Dichalcogenides

2D Janus Transition Metal Dichalcogenides (TMDs) have attracted much interest due to their exciting quantum properties arising from their unique two-faced structure, broken-mirror symmetry, and consequent colossal polarization field within the monolayer. While efforts are made to achieve high-quality Janus monolayers, the existing methods rely on highly energetic processes that introduce unwanted grain-boundary and point defects with still unexplored effects on the material's structural and excitonic properties Through high-resolution scanning transmission electron microscopy (HRSTEM), density functional theory (DFT), and optical spectroscopy measurements; this work introduces the most encountered and energetically stable point defects. It establishes their impact on the material's optical properties. HRSTEM studies show that the most energetically stable point defects are single (V S and V Se ) and double chalcogen vacancy (V S −V Se ), interstitial defects (Mi), and metal impurities (MW) and establish their structural characteristics. DFT further establishes their formation energies and related localized bands within the forbidden band. Cryogenic excitonic studies on h-BN-encapsulated Janus monolayers offer a clear correlation between these structural defects and observed emission features, which closely align with the results of the theory. Finally, the overall results introduce the defect genome of Janus TMDs as an essential guideline for assessing their structural quality and device properties.

2D materials↗

Assessment of the NPP VIIRS RVS for the Thermal Emissive Bands Using the First Pitch Maneuver Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on Suomi NPP (National Polar-orbiting Partnership) satellite (http://npp.gsfc.nasa.gov/viirs.html) (launched in October 2011). VIIRS sensor design draws on heritage instruments including AVHRR, OLS, SeaWiFS and MODIS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first three months of intensive Cal/Val. The NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of scan angles, which can be used to characterize the TEB RVS. This study will provide our analysis of the pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab tests will be conducted for each band, detector, and half angle mirror (HAM) side

Wu, A.↗

Balloon-borne cryogenic spectrometer for measurement of lower stratospheric trace constituents

A liquid-nitrogen cooled, multidetector Fourier transform spectrometer has been constructed to measure minor stratospheric constituents via high resolution, earth-limb emission spectroscopy from a balloon-borne platform. Cryogenic cooling, combined with the use of extrinsic silicon photoconductor detectors cooled to liquid-helium temperature, allows the detection of weak emission features of gaseous species. The spectrometer has two basic scan modes: the first mode records the continuous spectrum from 650-2100/cm with 0.2/cm resolution; the second simultaneously records four preselected narrow intervals (about 175/cm bandpass each) with 0.02/cm resolution, unapodized. Filtering of the interferogram signal is done by real-time, digital signal processing. The most important feature of this flat mirror Michelson system, with respect to remote balloon-borne operation, is the dynamic alignment system which maintains the relative parallelism of the two flat reflectors of the interferometer. Species identified to date in data obtained during a Nov. 6, 1984, flight include: CO2, O3, H2O, CH4, HNO3, N2O, NO2, NO, CCl3F (Freon-11) and CF2Cl2 (Freon-12).

Brasunas, J. C.↗

The MIPAS balloon borne trace constitutent experiment

A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

Oelhaf, H.↗

Raman Lidar Measurements During the International H2O Project: Instrument Comparisons and Case Studies - 2

The NASA/GSFC Scanning Raman Lidar (SRL) participated in the International H2O Project (IHOP) that occurred in May and June, 2002 in the midwestern part of the U. S. The SRL system configuration and methods of data analysis were described in part I of this paper. In this second part, comparisons of SRL water vapor measurements and those of chilled mirror radiosonde and LASE airborne water vapor lidar are performed. Two case studies are presented; one for daytime and one for nighttime. The daytime case study is of a convectively driven boundary layer event and is used to characterize the SRL water vapor random error characteristics. The nighttime case study is of a thunderstorm-generated cirrus cloud case that is studied in it s meteorological context. Upper tropospheric humidification due to precipitation from the cirrus cloud is quantified as is the cirrus cloud ice water content and particle depolarization ratio. These detailed cirrus cloud measurements are being used in a cirrus cloud modeling study.

Whiteman, D. N.↗

Smaller, Lower-Power Fast-Neutron Scintillation Detectors

Scintillation-based fast-neutron detectors that are smaller and less power-hungry than mainstream scintillation-based fast-neutron detectors are undergoing development. There are numerous applications for such detectors in monitoring fast-neutron fluxes from nuclear reactors, nuclear materials, and natural sources, both on Earth and in outer space. A particularly important terrestrial application for small, low-power, portable fast-neutron detectors lies in the requirement to scan for nuclear materials in cargo and baggage arriving at international transportation facilities. The present development of miniature, low-power scintillation-based fast-neutron detectors exploits recent advances in the fabrication of avalanche photodiodes (APDs). Basically, such a detector includes a plastic scintillator, typically between 300 and 400 m thick with very thin silver mirror coating on all its faces except the one bonded to an APD. All photons generated from scintillation are thus internally reflected and eventually directed to the APD. This design affords not only compactness but also tight optical coupling for utilization of a relatively large proportion of the scintillation light. The combination of this tight coupling and the avalanche-multiplication gain (typically between 750 and 1,000) of the APD is expected to have enough sensitivity to enable monitoring of a fast-neutron flux as small as 1,000 cm(exp -2)s(exp -1). Moreover, pulse-height analysis can be expected to provide information on the kinetic energies of incident neutrons. It has been estimated that a complete, fully developed fast-neutron detector of this type, would be characterized by linear dimensions of the order of 10 cm or less, a mass of no more than about 0.5 kg, and a power demand of no more than a few watts.

Patel, Jagdish↗

Limb-atmospheric infrared spectrum observed on the satellite Ohzora

The Institute of Space and Astronautical Science (ISAS) launched the 9th scientific satellite Ohzora at 17:00 JST on February 14, 1984. This satellite bears the spectrometer, which measures the infrared spectrum of the solar radiation passing the limb atmosphere in the wavelength region of 2 to 10 m. The spectrometer is based on multichannel spectroscopy by using image sensors. Since the wavelength is scanned electronically, it can measure the spectrum unaffected by the satellite motion. A definite axis, i.e., the Z-axis of the satellite, which coincides to the optical axis of the spectrometer, is controlled to the direction of the Sun, and the finer control to introduce the solar light into the spectrometer is made with a 2-axes-controlled mirror. This solar tracking equipment is derived fast enough to measure the spectra in a moment after sunrise. The solar light introduced into the spectrometer is focused on the slits of the monochromators (f=100mm). For better altitude resolution, the horizontal slit is also used with the vertical slit, which is used for the separation of the dispersion. The dispersion light is detected with the pyroelectric array sensors. To obtain maximum dynamic range and spectral resolution, the three-stage polychromator is used.

Matsuzaki, A.↗