Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor placement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Distributed Acoustic Sensing of Strain at Earth Tide Frequencies

The solid Earth strains in response to the gravitational pull from the Moon, Sun, and other planetary bodies. Measuring the flexure of geologic material in response to these Earth tides provides information about the geomechanical properties of rock and sediment. Such measurements are particularly useful for understanding dilation of faults and fractures in competent rock. A new approach to measuring earth tides using fiber optic distributed acoustic sensing (DAS) is presented here. DAS was originally designed to record acoustic vibration through the measurement of dynamic strain on a fiber optic cable. Here, laboratory experiments demonstrate that oscillating strain can be measured with DAS in the microHertz frequency range, corresponding to half-day (M2) lunar tidal cycles. Although the magnitude of strain measured in the laboratory is larger than what would be expected due to earth tides, a clear signal at half-day period was extracted from the data. With the increased signal-to-noise expected from quiet field applications and improvements to DAS using engineered fiber, earth tides could potentially be measured in deep boreholes with DAS. Because of the distributed nature of the sensor (0.25 m measurement interval over kilometres), fractures could be simultaneously located and evaluated. Such measurements would provide valuable information regarding the placement and stiffness of open fractures in bedrock. Characterization of bedrock fractures is an important goal for multiple subsurface operations such as petroleum extraction, geothermal energy recovery, and geologic carbon sequestration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature Laser Magnetometer

A conceptual design has been developed for a miniature laser magnetometer (MLM) that will measure the scalar magnitude and vector components of near-Earth magnetic fields. The MLM incorporates a number of technical innovations to achieve high-accuracy and high-resolution performance while significantly reducing the size of the laser-pumped helium magnetometer for use on small satellites and unmanned aerial vehicles (UAVs). and electronics sections that has the capability of measuring both the scalar magnetic field magnitude and the vector magnetic field components. Further more, the high-accuracy scalar measurements are used to calibrate and correct the vector component measurements in order to achieve superior vector accuracy and stability. The correction algorithm applied to the vector components for calibration and the same cell for vector and scalar measurements are major innovations. The separate sensor and electronics section of the MLM instrument allow the sensor to be installed on a boom or otherwise located away from electronics and other noisy magnetic components. The MLM s miniaturization will be accomplished through the use of advanced miniaturized components and packaging methods for the MLM sensor and electronics. The MLM conceptual design includes three key innovations. The first is a new non-magnetic laser package that will allow the placement of the laser pump source near the helium cell sensing elements. The second innovation is the design of compact, nested, triaxial Braunbek coils used in the vector measurements that reduce the coil size by a factor of two compared to existing Helmholtz coils with similar field-generation performance. The third innovation is a compact sensor design that reduces the sensor volume by a factor of eight compared to MLM s predecessor.

Slocum, Robert↗

Robot Gripper With Signal Processing

Single-chip computer and sensor-circuit chips preprocess sensor data. Self-contained circuitry combines sensor signals for serial digital transmission. Gripping surfaces crossed with grooves for grasping differently shaped objects. Gripper cavities house sensors and preprocessing circuitry. Sensors and preprocessing circuitry in robot gripper reduce amount of data being transmitted between robot controller and gripper. Placement in gripper reduces signal delays and vulnerability to electromagnetic interference.

Killion, Richard R.↗

Science Target Assessment for Mars Rover Instrument Deployment

This paper introduces the system being developed at NASA Ames Research Center, intended for the Mars '09 Smart Lander, to robustly place sensors or tools against rocks in a single communications cycle. Science targets must be assessed prior to instrument placement in order to segment them from the background and determine where, if possible, to position the instrument. An initial result of this research effort is a novel Bayesian based method for segmenting rocks from the ground using 3D data.

Pedersen, Liam↗

Preliminary Characterizations of Altair Lunar Lander Slosh Dynamics and Some Implications for TVC Design

During thrust maneuvers, the sloshing of fuel in partially filled tanks could interact with the controlled system in such a way as to cause the overall system to be unstable. This failure mode could be a result of poor coordination between systems engineers of Structures, Propulsion, GN&C, Mission Operations, and other subsystems. Attentions to the following is a minimum: Placements of fuel tanks, Tank shapes and baffle designs, Separation of TVC BW from slosh mode frequencies, Adequacy of excursion range of engine gimbal actuators in all engine burns, BW of sensors (e.g., gyroscopes) and actuators (e.g., engine gimbal), Structural frequencies of spacecraft and engine mounts, Prediction of S/C's c.m. location, canting of gimbal null axis, others. Check overall TVC performance via validated simulation test bed. Modeling fuel slosh during spacecraft thrusting maneuvers • Placement of fuel tanks to guarantee stable interactions between fuel slosh mode and the S/C rigid-body mode • Estimation of slosh frequencies (as a function of mission phases): – Estimation of slosh mode damping • Some implications for Thrust Vector Control design: – Selection of TVC controller bandwidth – Adequacy of the excursion range of engine gimbal actuator • TVC system design: Complex Interactions between GN&C, Propulsion, Structure, and Other Subsystems

Thrust vector control↗

Precise computer controlled positioning of robot end effectors using sensory feedback

A preliminary study of the combined position/force control using sensory feedback for a one-dimensional manipulator model, which may count for the spacecraft docking problem or to be extended to the multijoint robot manipulator problem, has been performed. The additional degrees of freedom introduced by the compliant force sensor is included in the system dynamics in the design of precise position control. State feedback based on pole placement method and with integral control is used to design the position controller. A simple constant gain force controller is used as an example to illustrate the dependence of the stability and steady-state accuracy of the overall position/force control on the design of the inner position controller. Supportive simulation results are also provided.

Wang, J. C.↗

Design and fabrication of non silicon substrate based MEMS energy harvester for arbitrary surface applications

Internet of Things (IoT) uses MEMS sensor nodes and actuators to sense and control objects through Internet. IOT deploys millions of chemical battery driven sensors at different locations which are not reliable many times because of frequent requirement of charging & battery replacement in case of underground laying, placement at harsh environmental conditions, huge count and difference between demand (24 % per year) and availability (energy density growing rate 8% per year). Energy harvester fabricated on silicon wafers have been widely used in manufacturing MEMS structures. These devices require complex fabrication processes, costly chemicals & clean room. In addition to this silicon wafer based devices are not suitable for curved surfaces like pipes, human bodies, organisms, or other arbitrary surface like clothes, structure surfaces which does not have flat and smooth surface always. Therefore, devices based on rigid silicon wafers are not suitable for these applications. Flexible structures are the key solution for this problems. Energy transduction mechanism generates power from free surrounding vibrations or impact. Sensor nodes application has been purposefully selected due to discrete power requirement at low duty cycle. Such nodes require an average power budget in the range of about 0.1 microwatt to 1 mW over a period of 3-5 seconds. Energy harvester is the best alternate source in contrast with battery for sensor node application. Novel design of Energy Harvester based on cheapest flexible non silicon substrate i.e. cellulose acetate substrate have been modeled, simulated and analyzed on COMSOL multiphysics and fabricated using sol-gel spin coating setup. Single cantilever based harvester generates 60-75 mV peak electric potential at 22Hz frequency and approximately 22 µW power at 1K-Ohm load. Cantilever array can be employed for generating higher voltage by replicating this structure. This work covers design, optimization, fabrication of harvester and schottky diodes based voltage multiplier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise computer controlled positioning of robot end effectors using force sensors

A thorough study of combined position/force control using sensory feedback for a one-dimensional manipulator model, which may count for the spacecraft docking problem or be extended to the multi-joint robot manipulator problem, was performed. The additional degree of freedom introduced by the compliant force sensor is included in the system dynamics in the design of precise position control. State feedback based on the pole placement method and with integral control is used to design the position controller. A simple constant gain force controller is used as an example to illustrate the dependence of the stability and steady-state accuracy of the overall position/force control upon the design of the inner position controller. Supportive simulation results are also provided.

Shieh, L. S.↗

Design and operation - Surface flux measurements in FIFE

A general overview of the structure, technology, and methodology of the investigation of surface flux is presented for the First International Satellite Land-Surface Climatology Project Field Experiment. The paper examines the placement of stations, choice of constants, instruments, and micrometeorological techniques, the information system, and comparisons between the data from the sensors and data from different sites. The differences between sites are generally small, and a similarity is noted in the magnitude of fluxes across all sites.

Kanemasu, E. T.↗

[MODIS Investigation]

Our first activity is based on delivery of code to Bob Evans (University of Miami) for integration and eventual delivery to the MODIS Science Data Support Team. As we noted in our previous semi-annual report, coding required the development and analysis of an end-to-end model of fluorescence line height (FLH) errors and sensitivity. This model is described in a paper in press in Remote Sensing of the Environment. Once the code was delivered to Miami, we continue to use this error analysis to evaluate proposed changes in MODIS sensor specifications and performance. Simply evaluating such changes on a band by band basis may obscure the true impacts of changes in sensor performance that are manifested in the complete algorithm. This is especially true with FLH that is sensitive to band placement and width. The error model will be used by Howard Gordon (Miami) to evaluate the effects of absorbing aerosols on the FLH algorithm performance. Presently, FLH relies only on simple corrections for atmospheric effects (viewing geometry, Rayleigh scattering) without correcting for aerosols. Our analysis suggests that aerosols should have a small impact relative to changes in the quantum yield of fluorescence in phytoplankton. However, the effect of absorbing aerosol is a new process and will be evaluated by Gordon.

Abbott, Mark R.↗

Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \textasciitilde 1 s response time from the sensor cluster [1].

Biewer, Theodore↗

Mission-Maps For Outbound Cislunar Transfer Trajectories

This study quantifies the robustness and sensitivity of an outbound cislunar trajectory for a lunar lander in the form of mission-maps, or topological maps that allows either a computer program or mission designer to intuitively optimize the placement of critical outbound correction burns from the derived sensitivity data. The non-linear multi-body dynamics are applied to generate an outbound cislunar reference profile used by a linear covariance analysis (LinCov) tool to compute the expected Δv and trajectory dispersions due to the initial state uncertainty, sensor errors, maneuver execution errors, and disturbance accelerations along the outbound cislunar profile. The rapid performance analysis capabilities of LinCov are complimented with parallel processing techniques to evaluate hundreds and thousands of different translational burn locations, placements, and targeting constraints to identify the combination that minimizes the total Δv usage (nominal plus 3σ Δv) and trajectory dispersions at lunar orbit insertion. This study utilizes a generalized reference targeting algorithm to quickly assess the integrated closed-loop GN&C system performance due to different targeting configurations and constraints. The resulting mission maps provide an intuitive insight to ascertain each trajectory correction maneuver’s (TCM) sensitivity to different burn times along an outbound cislunar trajectory and quickly identify desirable engineering tradeoffs when performing analysis on the number and placement of these burns that nominally zero. Multiple mission maps are generated for a variety of different performance parameters that allow engineers to visually identify optimal solutions for trajectory correction maneuver placements, the number of correction burns, and the targeting constraints for each burn.

GN&C↗

Langley Research Center - Soluble Imide (LaRC-SI)

This report is about experimenting and developing uses for the new thermal plastic developed by Dr. Robert Bryant called the 'Langley Research Center - Soluble Imide' (LaRC-SI). The three developments are: the use of the LaRC-SI as a dielectric for thin film sensors, as an adhesive to place diamonds on surfaces to increase thermal conductivity, and as an intermediate layer to allow the placement of metal on aluminum nitride. The LaRC-SI was developed by Dr. Robert G. Bryant, a chemical engineer at NASA Langley Research Center. The unique properties of this material is that it is an amorphous thermoplastic. This means that it can be reformed at elevated temperature and pressures. It can be applied in the form of a spray, spin, dip coating, paint, or spread with a doctors blade. The LaRC-SI has excellent adhesive and dielectric properties. It can also be recycled. Potential applications for this material are resin for mechanical parts such as gears, bearings and valves, advanced composites like carbon fiber, high strength adhesives, thin film circuits, and as a dielectric film for placing electrical components on conductive materials.

Stang, David↗

Extensibility in local sensor based planning for hyper-redundant manipulators (robot snakes)

Partial Shape Modification (PSM) is a local sensor feedback method used for hyper-redundant robot manipulators, in which the redundancy is very large or infinite such as that of a robot snake. This aspect of redundancy enables local obstacle avoidance and end-effector placement in real time. Due to the large number of joints or actuators in a hyper-redundant manipulator, small displacement errors of such easily accumulate to large errors in the position of the tip relative to the base. The accuracy could be improved by a local sensor based planning method in which sensors are distributed along the length of the hyper-redundant robot. This paper extends the local sensor based planning strategy beyond the limitations of the fixed length of such a manipulator when its joint limits are met. This is achieved with an algorithm where the length of the deforming part of the robot is variable. Thus , the robot's local avoidance of obstacles is improved through the enhancement of its extensibility.

Choset, Howie↗

Number and placement of control system components considering possible failures

One of the first questions facing the designer of the control system for a large space structure is how many components actuators and sensors - to specify and where to place them on the structure. This paper presents a methodology which is intended to assist the designer in making these choices. A measure of controllability is defined which is a quantitative indication of how well the system can be controlled with a given set of actuators. Similarly, a measure of observability is defined which is a quantitative indication of how well the system can be observed with a given set of sensors. Then the effect of component unreliability is introduced by computing the average expected degree of controllability (observability) over the operating lifetime of the system accounting for the likelihood of various combinations of component failures. The problem of component location is resolved by optimizing this performance measure over the admissible set of locations. The variation of this optimized performance measure with number of actuators (sensors) is helpful in deciding how many components to use.

Vander Velde, W. E.↗

Assembly of CMS Endcap MIP Timing Detector Module at FNAL

The High-Luminosity LHC (HL-LHC) will enable a more detailed exploration of new phenomena thanks to an anticipated increase in collisions where pileup is expected to reach approximately 200 simultaneous interactions. Many CMS systems will be significantly upgraded to prepare for this new era, including the MIP Timing Detector (MTD) project. The MTD is designed to mitigate the effect of pileup and is set to provide a timestamp accurate to 30 ~ 40 picoseconds for every event, ensuring sustained detector performance at HL-LHC. The MTD is divided into two sections, Barrel Timing Layer (BTL) and Endcap Timing Layer (ETL) which utilize different sensor and ASIC technologies due to the difference in active surfaces, irradiation conditions, and installation schedules. The ETL, composed of two double-sided disks, employs the Low Gain Avalanche Detector (LGAD) sensor and the Endcap Timing Readout Chip (ETROC). More than 8,000 modules, each consisting of four LGAD sensors and ETROCs are required for the ETL detector. These modules will be assembled using an automated robotic gantry that guarantees precise placement at a level of 10 micrometers. In addition, the full assembly of ETL modules includes film application with the jig, wire-bonding, encapsulation with the automated dispensing robot for protecting the wire-bonding, and film curing with a vacuum oven. This talk reports on the successfully completed throughput test with mockup components using the gantry and the successful assembly of real functional modules for beam tests at CERN and FNAL, including the first official ETL module.

Apresyan, Artur↗

Ultrasensitive measurement of microcantilever displacement below the shot-noise limit

The displacement of micro-electro-mechanical-systems (MEMs) cantilevers is used to measure a variety of phe- nomena in devices ranging from force microscopes for single spin detection[1] to biochemical sensors[2] to un- cooled thermal imaging systems[3]. The displacement readout is often performed optically with segmented de- tectors or interference measurements. Until recently, var- ious noise sources have limited the minimum detectable displacement in MEMs systems, but it is now possible to minimize all other sources[4] so that the noise level of the coherent light eld, called the shot noise limit (SNL), becomes the dominant source. Light sources dis- playing quantum-enhanced statistics below this limit are available[5, 6], with applications in gravitational wave astronomy[7] and bioimaging[8], but direct displacement measurements of MEMS cantilevers below the SNL have been impossible until now. Here, we demonstrate the rst direct measurement of a MEMs cantilever displace- ment with sub-SNL sensitivity, thus enabling ultratrace sensing, imaging, and microscopy applications. By com- bining multi-spatial-mode quantum light sources with a simple dierential measurement, we show that sub-SNL MEMs displacement sensitivity is highly accessible com- pared to previous eorts that measured the displacement of macroscopic mirrors with very distinct spatial struc- tures crafted with multiple optical parametric ampliers and locking loops[9]. We apply this technique to a com- mercially available microcantilever in order to detect dis- placements 60% below the SNL at frequencies where the microcantilever is shot-noise-limited. These results sup- port a new class of quantum MEMS sensor whose ulti- mate signal to noise ratio is determined by the correla- tions possible in quantum optics systems.

47 OTHER INSTRUMENTATION↗