Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A tactual display aid for primary flight training

A means of flight instruction is discussed. In addition to verbal assistance, control feedback was continously presented via a nonvisual means utilizing touch. A kinesthetic-tactile (KT) display was used as a readout and tracking device for a computer generated signal of desired angle of attack during the approach and landing. Airspeed and glide path information was presented via KT or visual heads up display techniques. Performance with the heads up display of pitch information was shown to be significantly better than performance with the KT pitch display. Testing without the displays showed that novice pilots who had received tactile pitch error information performed both pitch and throttle control tasks significantly better than those who had received the same information from the visual heads up display of pitch during the test series of approaches to landing.

Gilson, R. D.↗

Implantable electrical device

A fully implantable and self contained device is disclosed composed of a flexible electrode array for surrounding damaged nerves and a signal generator for driving the electrode array with periodic electrical impulses of nanoampere magnitude to induce regeneration of the damaged nerves.

Jhabvala, M. D.↗

Beta experiment

A focused laser doppler velocimeter (LDV) system was developed for the measurement of atmospheric backscatter (beta) from aerosols at infrared wavelengths. A Doppler signal generator was used in mapping the coherent sensitive focal volume of a focused LDV system. System calibration data was analyzed during the flight test activity scheduled for the Beta system. These analyses were performed to determine the acceptability of the Beta measurement system's performance.

Source record↗

Controlling An Inverter-Driven Three-Phase Motor

Control system for three-phase permanent-magnet motor driven by linecommutated inverter uses signals generated by integrating back emf of each phase of motor. High-pass filter network eliminates low-frequency components from control loop while maintaining desired power factor.

Dolland, C.↗

Synchronized voltage contrast display analysis system

An apparatus and method for comparing internal voltage potentials of first and second operating electronic components such as large scale integrated circuits (LSI's) in which voltage differentials are visually identified via an appropriate display means are described. More particularly, in a first embodiment of the invention a first and second scanning electron microscope (SEM) are configured to scan a first and second operating electronic component respectively. The scan pattern of the second SEM is synchronized to that of the first SEM so that both simultaneously scan corresponding portions of the two operating electronic components. Video signals from each SEM corresponding to secondary electron signals generated as a result of a primary electron beam intersecting each operating electronic component in accordance with a predetermined scan pattern are provided to a video mixer and color encoder.

Johnston, M. F.↗

Synchronized Radar-Target Simulator

Apparatus for testing radar system generates signals that simulate amplitude and phase characteristics of target returns and their variation with antenna-pointing direction. Antenna movement causes equipment to alter test signal in imitation of behavior of real signal received during tracking.

Chin, B. C.↗

SAR calibration: A technology review

Various potential applications of amplitude-calibrated SAR systems are briefly described, along with an estimate of calibration performance requirements. A review of the basic SAR calibration problem is given. For background purposes and to establish consistent definition of terms, various conventional SAR performance parameters are reviewed along with three additional parameters which are directly related to calibrated SAR systems. Techniques for calibrating a SAR are described. Included in the results presented are: calibration philosophy and procedures; review of the calibration signal generator technology development with results describing both the development of instrumentation and internal calibration measurements for two SAR systems; summary of analysis and measurements required to determine optimum retroreflector design and configuration for use as a reference for the absolute calibration of a SAR system; and summary of techniques for in-flight measurements of SAR antenna response.

Larson, R. W.↗

A High-performance Hybrid RF Isolation Amplifier

A high-performance hybrid RF Isolation Amplifier (Iso-Amp) has been developed at JPL. The circuit exhibits a unique combination of RF characteristics at performance levels exceeding those of any commercially available device. Recent improvments in the design have resulted in significantly higher reverse isolation, a four-fold increase in bandwidth and improve reliability. These devices are very useful in RF and IF signal conditioners, instrumentation, and signal generation and distribution equipment. These Iso-Amps should find wide application in future DSN and R&D RF systems.

Stevens, G. L.↗

Determining Internal Connections in Capacitors

Simple electrical test shows which terminals connected to outer capacitor foil. Test makes it unnecessary to resort to X-ray inspection to distinguish terminals. When outer foil of capacitor is attached to ungrounded signal-generator output lead, oscilloscope displays higher waveform amplitude. When outer foil is joined to grounded signalgenerator output lead, waveform amplitude is lower. Test also used to determine internal connections in multiple-element capacitors.

Ott, F. M.↗

Feedback-Controlled Regulation of Gas Pressure

Internal pressure maintained over wide range of external pressures and exhaust rates. Gaseous pressure in liquid-nitrogen Dewar regulated by movable tapered plug, positioned automatically in response to signals generated by piezoelectric pressure transducer. Designed specifically to maintain airborne infrared detectors at constant temperature in evaporating liquid nitrogen, system modified to regulate pressure in other enclosed systems.

Smith, J. C.↗

Simple, Inexpensive Servoamplifier

Circuit based on consumer-market audio-amplifier chip. Stereo audio amplifier chip, connected as servoamplifier, supplies more than 1 A to motor. Amplifier used in analog configuration to supply proportional torque to motor, simpler circuits and more efficient use of energy result when utilized in pulse-width-modulation mode. Pulse-width signals generated directly by computer software or external pulse-width-modulation generator.

Garner, H. Douglas↗

Further development of the dynamic gas temperature measurement system. Volume 1: Technical efforts

A compensated dynamic gas temperature thermocouple measurement method was experimentally verified. Dynamic gas temperature signals from a flow passing through a chopped-wheel signal generator and an atmospheric pressure laboratory burner were measured by the dynamic temperature sensor and other fast-response sensors. Compensated data from dynamic temperature sensor thermoelements were compared with fast-response sensors. Results from the two experiments are presented as time-dependent waveforms and spectral plots. Comparisons between compensated dynamic temperature sensor spectra and a commercially available optical fiber thermometer compensated spectra were made for the atmospheric burner experiment. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Gyroresonant pitch angle scattering by coherent and incoherent whistler mode waves in the magnetosphere

A test particle approach is used to compare gyroresonant pitch angle scattering of energetic electrons by coherent versus incoherent whistler mode waves, for the case in which the coherent wave amplitude is below the nonlinear phase trapping threshold. Wave packets of 400 ms duration propagating along the magnetic field at L = 4 within the plasmasphere are considered, and the wave-induced pitch angle scattering along the propagation path from one hemisphere to the other and the resulting precipitation flux are computed. An incoherent wave spectrum is simulated by random modulation of the wave frequency at intervals of 1 ms, thereby generating signals with nearly constant power spectral density over a bandwidth of 2 kHz centered at 5.5 kHz. The associated pitch angle scattering is compared with that of a monochromatic 5.5-kHz signal of 400 ms duration. Results of the test particle analysis are compared with those expected on the basis of a classical diffusion treatment, and an expression is derived for an effective “diffusion” coefficient for pitch angle scattering by coherent waves. The trajectory followed by a particle when interacting with incoherent waves essentially represents a random walk in velocity space, while for coherent waves the pitch angle of the particle varies in a well-defined manner. In spite of the fact that individual particle scatterings are typically larger for coherent waves, the peak precipitation fluxes induced by incoherent waves are found to be approximately the same as those for coherent waves having the same total power. This results from the fact that incoherent waves interact with particles over a wider range of energies. As a consequence, the energy spectrum and the temporal extent of transient precipitation pulses due to incoherent wave packets are broader than those for equivalent coherent ones.

Umran S Inan↗

Punch stretching process monitoring using acoustic emission signal analysis. II - Application of frequency domain deconvolution

The coloring effect on the acoustic emission signal due to the frequency response of the data acquisition/processing instrumentation may bias the interpretation of AE signal characteristics. In this paper, a frequency domain deconvolution technique, which involves the identification of the instrumentation transfer functions and multiplication of the AE signal spectrum by the inverse of these system functions, has been carried out. In this way, the change in AE signal characteristics can be better interpreted as the result of the change in only the states of the process. Punch stretching process was used as an example to demonstrate the application of the technique. Results showed that, through the deconvolution, the frequency characteristics of AE signals generated during the stretching became more distinctive and can be more effectively used as tools for process monitoring.

Liang, Steven Y.↗

An innovative workstation

A workstation was developed which uses the operator's eye movements and position to determine the placement of the cursor on a computer screen. A brainwave sensing technology overview and an introduction to the known rhythms or signals generated by the brain are given. This is followed by a descriptive explanation of the Ocular Attention Interface System (OASIS) and its intended integration into the proposed testbed.

Villarreal, James↗

Development of three-way ranging for the Voyager Neptune encounter

Range data will be used to help navigate Voyager 2 to Neptune and the most distant planetary encounter ever attempted. In preparation for this challenging August 1989 planetary encounter, a new data type, known as 'three-way range', has been developed. With three-way ranging, a ranging signal generated at a ground station, received at the spacecraft and transponded to Earth is then received coherently at a second tracking station, which can be distant from the transmitting station. This paper contains analytic and operational descriptions of three-way range. Hardware modifications and design necessary for implementing this new data type are discussed. Preliminary assessments of three-way ranging performance are given and accuracies are discussed.

Roth, D. C.↗

Adaptive antenna arrays for satellite communication

The feasibility of using adaptive antenna arrays to provide interference protection in satellite communications was studied. The feedback loops as well as the sample matric inversion (SMI) algorithm for weight control were studied. Appropriate modifications in the two were made to achieve the required interference suppression. An experimental system was built to test the modified feedback loops and the modified SMI algorithm. The performance of the experimental system was evaluated using bench generated signals and signals received from TVRO geosynchronous satellites. A summary of results is given. Some suggestions for future work are also presented.

Gupta, Inder J.↗

How to detect when cells in space perceive gravity

It is useful to be able to measure when and whether cells detect gravity during spaceflights. For studying gravitational physiology, gravity perception is the response the experimentalist needs to measure. Also, for growing plants in space, plant cells may have a non-directional requirement for gravity as a development cue. The main goals of spaceflight experiments in which gravity perception would be measured are to determine the properties of the gravity receptor and how it is activated, and to determine fundamental characteristics of the signal generated. The main practical difficulty with measuring gravity sensing in space is that gravity sensing cannot be measured with certainty on earth. Almost all experiments measure gravitropic curvature. Reciprocity and intermittent stimulation are measurements which were made to some degree on earth using clinostatting, but which would provide clearer results if done with microgravity rather than clinostatting. These would be important uses of the space laboratory for determining the nature of gravity sensing in plants. Those techniques which do not use gravitropic curvature to measure gravity sensing are electrophysiological. The vibrating probe would be somewhat easier to adapt to space conditions than the intracellular microelectrode because it can be positioned with less precision. Ideally, a non-invasive technique would be best suited if an appropriate measure could be developed. Thus, the effect of microgravity on cultured cells is more likely to be by large-scale physical events than gravity sensing in the culture cells. It is not expected that it will be necessary to determine whether individual cultured cells perceive gravity unless cells grow abnormally even after the obvious microgravity effects on the culture as a whole can be ruled out as the cause.

Bjoerkman, Thomas↗