Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signaling molecules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Label-free nanoscopy of cell metabolism by ultrasensitive reweighted visible stimulated Raman scattering

Nanoscopic imaging of cell metabolism is hindered by the incompatibility of small metabolites with fluorescent dyes and the limited resolution of imaging mass spectrometry. We present ultrasensitive reweighted visible stimulated Raman scattering (URV-SRS), a label-free vibrational nanoscopy technique that enables multiplexed detection of metabolic nanostructures within cells. We developed an extensively chirped spectral focusing visible SRS microscope that achieves a detection limit of 4,000 molecules and introduced a self-supervised learning-based denoiser to robustly suppress non-independent SRS noise by over 7.2 dB. The instrumentation-based signal enhancement and computation-based noise suppression synergistically improved the detection sensitivity by 50 times over near-infrared SRS. Leveraging this enhanced sensitivity, we further pushed the resolution to nanoscopic levels by introducing Fourier reweighting to amplify sub-100 nm spatial frequencies previously overwhelmed by noise. Validated by Fourier ring correlation, URV-SRS achieves a lateral resolution of 86 nm in cellular imaging. Here, we applied URV-SRS to elucidate the reprogramming of metabolic nanostructures associated with virus replication in Vero E6 host cells and to compositionally delineate subcellular fatty acid synthesis in engineered Escherichia coli, demonstrating its capability towards nanoscopic spatial metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Selecting XFEL single-particle snapshots by geometric machine learning

A promising new route for structural biology is single-particle imaging with an X-ray Free-Electron Laser (XFEL). This method has the advantage that the samples do not require crystallization and can be examined at room temperature. However, high-resolution structures can only be obtained from a sufficiently large number of diffraction patterns of individual molecules, so-called single particles. Here, we present a method that allows for efficient identification of single particles in very large XFEL datasets, operates at low signal levels, and is tolerant to background. This method uses supervised Geometric Machine Learning (GML) to extract low-dimensional feature vectors from a training dataset, fuse test datasets into the feature space of training datasets, and separate the data into binary distributions of “single particles” and “non-single particles.” As a proof of principle, we tested simulated and experimental datasets of the Coliphage PR772 virus. We created a training dataset and classified three types of test datasets: First, a noise-free simulated test dataset, which gave near perfect separation. Second, simulated test datasets that were modified to reflect different levels of photon counts and background noise. These modified datasets were used to quantify the predictive limits of our approach. Third, an experimental dataset collected at the Stanford Linear Accelerator Center. The single-particle identification for this experimental dataset was compared with previously published results and it was found that GML covers a wide photon-count range, outperforming other single-particle identification methods. Moreover, a major advantage of GML is its ability to retrieve single particles in the presence of structural variability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

670-GHz Down- and Up-Converting HEMT-Based Mixers

A large category of scientific investigation takes advantage of the interactions of signals in the frequency range from 300 to 1,000 GHz and higher. This includes astronomy and atmospheric science, where spectral observations in this frequency range give information about molecular abundances, pressures, and temperatures of small-sized molecules such as water. Additionally, there is a minimum in the atmospheric absorption at around 670 GHz that makes this frequency useful for terrestrial imaging, radar, and possibly communications purposes. This is because 670 GHz is a good compromise for imaging and radar applications between spatial resolution (for a given antenna size) that favors higher frequencies, and atmospheric losses that favor lower frequencies. A similar trade-off applies to communications link budgets: higher frequencies allow smaller antennas, but incur a higher loss. All of these applications usually require converting the RF (radio frequency) signal at 670 GHz to a lower IF (intermediate frequency) for processing. Further, transmitting for communication and radar generally requires up-conversion from IF to the RF. The current state-of-the-art device for performing the frequency conversion is based on Schottky diode mixers for both up and down conversion in this frequency range for room-temperature operation. Devices that can operate at room temperature are generally required for terrestrial, military, and planetary applications that cannot tolerate the mass, bulk, and power consumption of cryogenic cooling. The technology has recently advanced to the point that amplifiers in the region up to nearly 1,000 GHz are feasible. Almost all of these have been based on indium phosphide pseudomorphic high-electron mobility transistors (pHEMTs), in the form of monolithic microwave integrated circuits (MMICs). Since the processing of HEMT amplifiers is quite differ en t from that of Schottky diodes, use of Schottky mixers requires separate MMICs for the mixers and amplifiers. Fabrication of all the down-/up-conversion circuitry on single MMICs, using a ll-HEMT circuits, would constitute a major advance in circuit simplicity.

Schlecht, Enrich T.↗

O 2 based resonantly ionized photoemission thermometry analysis of supersonic flows

Characterization of the thermal gradients within supersonic and hypersonic flows is essential for understanding transition, turbulence, and aerodynamic heating. Developments in novel, impactful non-intrusive techniques are key for enabling flow characterizations of sufficient detail that provide experimental validation datasets for computational simulations. In this work, Resonantly Ionized Photoemission Thermometry (RIPT) signals are directly imaged using an ICCD camera to realize the techniques 1D measurement capability for the first time. The direct imaging scheme presented for oxygen-based RIPT (O 2 RIPT) uses the previously established calibration data to direct excite various resonant rotational peaks within the S-branch of the C 3 Π, ( v = 2) ← X 3 Σ( v ′ = 0) absorption band of O 2 . The efficient ionization of O 2 liberates electrons that induce electron avalanche ionization of local N 2 molecules generating N 2 + , which primarily deexcites via photoemissions of the first negative band of N 2 + ( B 2 Σ <#comment/> u + − <#comment/> X 2 Σ <#comment/> g + ) . When sufficient lasing energy is used, the ionization region and subsequent photoemission signal is achieved along a 1D line thus, if directly imaged can allow for gas temperature assignments along said line; demonstrated here of up to five centimeters in length. The temperature gradients present within the ensuing shock train of a supersonic under expanded free jet serves as a basis of characterization for this new RIPT imaging scheme. The O 2 RIPT results are extensively compared and validated against well-known and established techniques (i.e., CARS and CFD). The direct imaging capability fully realizes the technique’s fundamental potential and is expected to be the standard of implementation going forward. The direct imaging capability can play instrumental roles in future scientific studies that rely upon acute characterization of thermal gradients within a medium that cannot be easily resolved by a point. Furthermore, the removal of the spectrometer greatly reduces the cost, complexity, and optical alignment associated with prior RIPT measurements.

42 ENGINEERING↗

An organogel library for solution NMR analysis of nanoparticle suspensions in non-aqueous samples

Surface contrast solution NMR methods (scNMR) are emerging as powerful tools to investigate the adsorption of small molecule ligands to the surface of nanoparticles (NP), returning fundamental insight into the kinetics and thermodynamics of sorption, as well as structural information on the adsorbed species. A prerequisite for the acquisition of high quality solution NMR data is the preparation of homogeneous and stable samples that return consistent NMR spectra and allow extensive signal averaging. Unfortunately, this condition does not apply to NMR samples containing NPs that often show a tendency to sediment and accumulate at the bottom of the NMR tube over the course of the experiment. We have recently shown that preparing NMR samples in an agarose gel matrix inhibits sedimentation and allows the characterization of small molecule-NP interactions by scNMR. Unfortunately, as the agarose gel only forms in aqueous solution, this sample preparation method cannot be used to stabilize NP suspensions in a non-aqueous environment. In this work, we introduce a library of 48 organogels, based on low molecular-mass organic gelators (LMOGs), to prepare NMR samples of small molecule/NP systems in a wide range of organic solvents. In addition, we present a simple method that takes advantage of 1H transverse relaxation (1H-R2) measurements to screen the library and identify the best gelator to characterize the small molecule-NP interaction of interest in the solvent of choice. We expect the results of this study will enable the preparation of homogeneous and stable samples of NPs in non-aqueous environments, therefore dramatically increasing the applicability of scNMR to the characterization of heterogeneous interactions and to the investigation of the role played by solvent molecules in regulating the kinetics and thermodynamics of sorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single Particle Cathodoluminescence Spectroscopy with Sub-20 nm, Electron-Stable Phosphors

Lanthanide-doped nanophosphors have emerged as promising optical labels for high-resolution, "multicolor"electron microscopy. Here, we develop a library of 11 unique lanthanide-doped nanophosphors with average edge lengths of 15.2 ± 2.0 nm (N = 4284). These nanophosphors consist of an electron-stable BaYF5 host lattice doped at 25% atomic concentration with the lanthanides Pr 3+ , Nd 3+ , Sm 3+ , Eu 3+ , Tb 3+ , Dy 3+ , Ce 3+ , Ho 3+ , Er 3+ , Tm 3+ , and Yb 3+ . Under ~100 pA/nm 2 beam beam current in a transmission electron microscope, each nanophosphor species exhibits strong cathodoluminescence spectra with sharp characteristic emission lines for each lanthanide. The bright emission and stability of these nanoparticles enable not only ensemble, but also single-particle cathodoluminescence spectroscopy, which we demonstrate with BaYF 5 :Ln 3+ , where Ln 3+ = Tb 3+ , Ho 3+ , Er 3+ , Sm 3+ , Eu 3+ , or Pr 3+ . Single-particle cathodoluminescence corresponds directly with HAADF intensity across nanoparticles, confirming high spatial localization of the measured cathodoluminescence signal of lanthanide-doped nanophosphors. Furthermore, our synthesis and characterization of sub-20 nm, electron-stable nanophosphors provides a robust material platform to achieve single-molecule labeled correlative cathodoluminescence electron microscopy, a critical foundation for high-resolution correlation of single molecules within the context of cellular ultrastructure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Pulsed, gridded electron reversal ionizer

The design and performance of a new-type source of negative ions is presented. This device retains the idea of the so-called reversal electron attachment detector to produce low-energy electrons by reversing electron trajectories at an electrode. Electrons are produced in the present device by several ribbon filaments that surround a cylindrical wire grid. They are accelerated through the grid, then decelerated to zero or near-zero velocity at the surface of a tube. The tube (anode) is perforated with small holes through which effuse the target molecules. Electrons attach to form either parent and/or fragment negative ions. Attachment takes place at a location above the anode corresponding to a match between the electron energy and the attachment resonance energy. Negative ions are pulsed out of the attachment region and focused onto the entrance plane of a quadrupole mass selector. Electron and ion trajectory calculations are presented and the performance illustrated with six molecules having attachment resonances in the range 0.0-2.2 eV. The detection sensitivity is below 1 part-per-trillion, with a calculated conversion rate of 1.3 percent. Signal nonlinearity is discussed in terms of ion space-charge effects. The device also produces positive ions, and an analogous treatment may be carried through to characterize its performance in this mode.

Boumsellek, S.↗

A new high-sensitivity superconducting receiver for mm-wave remote-sensing spectroscopy of the stratosphere

We describe a recently constructed ground-based mm-wave spectrometer incorporating a superconducting tunnel junction as a heterodyne mixer-receiver. Under conditions of low tropospheric water vapor, the superior sensitivity of this receiver allows spectral line measurements of stratospheric molecules with mixing ratios as small as a few tenths of a part per billion (e.g., ClO, HCN) to be made in 4 to 6 hours, with a signal to noise ratio of at least 30:1. We expect to be able to halve this time by further improvement of the mixer's intrinsic noise level.

Dezafra, R. L.↗

Modeling the Activity of Single Genes

The central dogma of molecular biology states that information is stored in DNA, transcribed to messenger RNA (mRNA) and then translated into proteins. This picture is significantly augmentated when we consider the action of certain proteins in regulating transcription. These transcription factors provide a feedback pathway by which genes can regulate one another's expression as mRNA and then as protein. To review: DNA, RNA and proteins have different functions. DNA is the molecular storehouse of genetic information. When cells divide, the DNA is replicated, so that each daughter cell maintains the same genetic information as the mother cell. RNA acts as a go-between from DNA to proteins. Only a single copy of DNA is present, but multiple copies of the same piece of RNA may be present, allowing cells to make huge amounts of protein. In eukaryotes (organisms with a nucleus), DNA is found in the nucleus only. RNA is copied in the nucleus then translocates(moves) outside the nucleus, where it is transcribed into proteins. Along the way, the RNA may be spliced, i.e., may have pieces cut out. RNA then attaches to ribosomes and is translated to proteins. Proteins are the machinery of the cell other than DNA and RNA, all the complex molecules of the cell are proteins. Proteins are specialized machines, each of which fulfills its own task, which may be transporting oxygen, catalyzing reactions, or responding to extracellular signals, just to name a few. One of the more interesting functions a protein may have is binding directly or indirectly to DNA to perform transcriptional regulation, thus forming a closed feedback loop of gene regulation. The structure of DNA and the central dogma were understood in the 50s; in the early 80s it became possible to make arbitrary modifications to DNA and use cellular machinery to transcribe and translate the resulting genes; more recently, genomes (i.e., the complete DNA sequence) of many organisms have been sequenced. This large-scale sequencing began with simple organisms, viruses and bacteria, progressed to eukaryotes such as yeast, and more recently (1998) progressed to a multi-cellular animal, the nematode Caenorhabditis elegans. Sequencers have now moved on to the fruit fly Drosophila melanogaster, whose sequence is slated for completion by the end of 1999. The human genome project is expected to determine the complete sequence of all 3 billion bases of human DNA within the next five years. In the wake of genome-scale sequencing, further instrumentation is being developed to assay gene expression and function on a comparably large scale. Much of the work in computational biology focuses on computational tools used in sequencing, finding genes that are related to a particular gene, finding which parts of the DNA code for proteins and which do not, understanding what proteins will be formed from a given length of DNA, predicting how the proteins will fold from a one-dimensional structure into a three dimensional structure, and so on. Much less computational work has been done regarding the function of proteins. One reason for this is that different proteins function very differently, and so work on protein function is very specific to certain classes of proteins. There are, for example, proteins such enzymes that catalyze various intracellular reactions, receptors that respond to extracellular signals and ion channels that regulate the flow of charged particles into and out of the cell. In this chapter, we will consider a particular class of proteins called transcription factors(TFs), which are responsible for regulating when a certain gene is expressed in a certain cell, which cells it is express in, and how much is expressed. Understanding these processes will involve developing a deeper understanding of transcription, translation, and the cellular processes that control those processes. All of these elements fall under the aegis of gene regulation or more narrowly transcriptional regulation. Some of the key questions in gene regulation are: What genes are expressed in a certain cell at a certain time? How does gene expression differ from cell to cell in a multicellular organism? Which proteins act as transcription factors, i.e., are important in regulating gene expression? From questions like these, we hope to understand which genes are important for various macroscopic processes. Nearly all of the cells of a multicellular organism contain the same DNA. Yet this same genetic information yields a large number of different cell types. The fundamental difference between a neuron and a liver cell, for example, is which genes are expressed. Thus understanding gene regulation is an important step in understanding development. Furthermore, understanding the usual genes that are expressed in cells may give important clues about various diseases. Some diseases, such as sickle cell anemia and cystic fibrosis, are caused by defects in single, non-regulatory genes; others, such as certain cancers, are caused when the cellular control circuitry malfunctions - an understanding of these diseases will involve pathways of multiple interacting gene products. There are numerous challenges in the area of understanding and modeling gene regulation. First and foremost, biologists would like to develop a deeper understanding of the processes involved, including which genes and families of genes are important, how they interact, etc. From a computation point of view, there has been embarrassingly little work done. In this chapter there are many areas in which we can phrase meaningful, non-trivial computational questions, but questions that have not been addressed. Some of these are purely computational (what is a good algorithm for dealing with a model of type X) and others are more mathematical (given a system with certain characteristics, what sort of model can one use? How does one find biochemical parameters from system-level behavior using as few experiments as possible?). In addition to biological and algorithmic problems, there is also the ever-present issue of theoretical biology - what general principles can be derived from these systems, what can one do with models other than just simulate time-courses, what can be deduced about a class of systems without knowing all the details? The fundamental challenge to computationalists and theorists is to add value to the biology - to use models, modeling techniques and algorithms to understand the biology in new ways.

Mjolsness, Eric↗

State-selective probing of CO 2 autoionizing inner valence Rydberg states with attosecond extreme ultraviolet four-wave-mixing spectroscopy

Nonlinear spectroscopies can disentangle spectra that are congested due to inhomogeneous broadening. Here, in conjunction with theoretical calculations, attosecond extreme ultraviolet (XUV) four-wave-mixing (FWM) spectroscopy is utilized to probe the dynamics of autoionizing inner valence excited Rydberg states of the polyatomic molecule, CO 2 . This tabletop nonlinear technique employs a short attosecond XUV pulse train and two noncollinear, few-cycle near-infrared pulses to generate background-free XUV wave-mixing signals. FWM emission is observed from the n=5-7 states of the Henning sharp ndσ g Rydberg series that converges to the ionic $\widetilde{B}$ 2 Σ$^{+}_{u}$ state. However, these transient emission signals decay with lifetimes of 33 ± 6, 53 ± 2, and 94 ± 2 fs, respectively, which calculations show are consistent with the lifetimes of the short-lived n=6-8 members of the nsσ g character Henning diffuse Rydberg series. The oscillator strengths of transitions between states involved in all possible resonant FWM processes are calculated, verifying that the nonlinear spectra are dominated by pathways described by an initial excitation to the diffuse nsσ g Rydberg series and emission from the sharp ndσ g Rydberg series. The results substantiate not only that attosecond XUV FWM spectroscopy produces rigorous and meaningful measurements of ultrafast dynamics in polyatomic systems, but also that nonlinear spectroscopic techniques are versatile tools to selectively probe dynamics that are otherwise difficult to access.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tip- and Plasmon-Enhanced Infrared Nanoscopy for Ultrasensitive Molecular Characterizations

Herein, we propose a method for ultrasensitive infrared (IR) vibrational spectroscopy of molecules with nanoscale footprints by combining the tip enhancement of a scattering-type scanning near-field optical microscope (s-SNOM) and the plasmon enhancement of breathing-mode (BM) plasmon resonances of graphene nanodisks (GNDs). To demonstrate this, we develop a quantitative model that is capable of computing accurately the s-SNOM signals of nanoscale samples. With our modeling, we show that the s-SNOM tip can effectively excite gate-tunable BM plasmonic resonances in GNDs with strong field enhancement and sensitive dependence on the size of GND. Moreover, we demonstrate that the intense electric field of tip-excited plasmonic BMs can strongly enhance the IR vibrational modes of molecules. As a result, IR vibrational signatures of individual molecular particles with sizes down to 1–2 nm are readily observable by s-SNOM. Our study sheds light on future ultrasensitive IR biosensing that takes advantage of both the tip and plasmon enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Manipulating cobalt oxide on N-doped aligned electrospun carbon nanofibers towards instant electrochemical detection of dopamine secreted by living cells

A demand exists for the development of miniaturized biosensors with high sensitivity and a wide dynamic range for rapid detecting dopamine (DA) levels. Here, an electrochemical sensor is created by decorating closely packed cobalt oxide (Co 3 O 4 ) nanograins on nitrogen-doped electrospun carbon nanofibers (NECNFs) via a facile electrodeposition method. The carbon nanofiber matrix provides both a scaffold with ultrahigh surface area for homogeneous dispersion of cobalt oxide nanostructures and facilitates the electrochemical conductivity for the hybrid electrode. The sensing principle is based on the redox reaction between DA and DA quinone that generates electrical signal, which is detectable via differential pulse voltammetry (DPV) and chronoamperometry (CA). Owing to a high electroactive surface area and facilitating electron transfer between electrode surface and the target molecule, the electrical sensing platform exhibits superior sensitivity and selectivity toward DA, with an excellent limit of detection (9 nM) over a wide range of concentrations (0.01 to 100 μM). Moreover, based on its excellent sensing properties and biocompatibility, the sensor has been used for the real-time monitoring exogeneous DA released from pheochromocytoma (PC12) cells. This work demonstrates promise of a novel sensor technology that may render rapid point-of-care testing of DA towards early clinical diagnosis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biochemical Sensors Using Carbon Nanotube Arrays

Method and system for detecting presence of biomolecules in a selected subset, or in each of several selected subsets, in a fluid. Each of an array of two or more carbon nanotubes ("CNTs") is connected at a first CNT end to one or more electronics devices, each of which senses a selected electrochemical signal that is generated when a target biomolecule in the selected subset becomes attached to a functionalized second end of the CNT, which is covalently bonded with a probe molecule. This approach indicates when target biomolecules in the selected subset are present and indicates presence or absence of target biomolecules in two or more selected subsets. Alternatively, presence of absence of an analyte can be detected.

Li, Jun↗

Binding and activation of major histocompatibility complex class II-deficient macrophages by staphylococcal exotoxins

Macrophages from C2D transgenic mice deficient in the expression of major histocompatibility complex (MHC) class II proteins were used to identify binding sites for superantigens distinct from the MHC class II molecule. Iodinated staphylococcal enterotoxins A and B (SEA and SEB) and exfoliative toxins A and B (ETA and ETB) bound to C2D macrophages in a concentration-dependent and competitive manner. All four toxins increased F-actin concentration within 30 s of their addition to C2D macrophages, indicating that signal transduction occurred in response to toxin in the absence of class II MHC. Furthermore, ETA, ETB, SEA, and, to a lesser extent, SEB induced C2D macrophages to produce interleukin 6. Several molecular species on C2D macrophages with molecular masses of 140, 97, 61, 52, 43, and 37 kDa bound SEA in immunoprecipitation experiments. These data indicate the presence of novel, functionally active toxin binding sites on murine macrophages distinct from MHC class II molecules.

Non-NASA Center↗

Imaging conical intersection dynamics during azobenzene photoisomerization by ultrafast X-ray diffraction

Significance Vibronic coherences are unique features that emerge in the decisive moments of photochemistry and photophysics. Here we demonstrate how X-ray diffraction can access fundamental information about these coherences. This is enabled by recent developments at free-electron lasers, working toward temporal resolution and single-molecule accessibility of scattering-based measurements. Time-resolved diffraction patterns of the isomerization of azobenzene are simulated. The process is monitored in time via the momentum-space signal, with a special focus on the mixed elastic/inelastic scattering from coherences. We give practical ideas on how this relatively weak contribution to the signal can potentially be retrieved. A direct connection to the real-space movie of the conical intersection dynamics is made, enabling the observation of quantum coherences that direct chemical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast Imaging of Molecules with Electron Diffraction

Photoexcited molecules convert light into chemical and mechanical energy through changes in electronic and nuclear structure that take place on femtosecond timescales. Gas phase ultrafast electron diffraction (GUED) is an ideal tool to probe the nuclear geometry evolution of the molecules and complements spectroscopic methods that are mostly sensitive to the electronic state. GUED is a passive probing tool that does not alter the molecular properties during the probing process and is sensitive to the spatial distribution of charge in the molecule, including both electrons and nuclei. Improvements in temporal resolution have enabled GUED to capture coherent nuclear motions in molecules in the excited and ground electronic states with femtosecond and subangstrom resolution. Here we present the basic theory of GUED and explain what information is encoded in the diffraction signal, review how GUED has been used to observe coherent structural dynamics in recent experiments, and discuss the advantages and limitations of the method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗