Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single point correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development of a Shuttle Infrared Telescope Facility /SIRTF/ fine guidance sensor

Fine guidance technology development for the Shuttle Infrared Telescope Facility (SIRTF) centers upon the use of a single multiple-star-tracking sensor to provide the position information necessary to produce three-axis attitude control signals for precision payload pointing. The effort described in this paper is concerned with the development of a fine guidance sensor that employs a high-density charge-coupled imaging device for producing position information signals by using star fields. Multiple star position information produces three-axis position error signals that are used to update inertial reference gyros. The sensor employs advanced position interpolation algorithms to enhance field-of-view resolution and to correct for optical aberrations inherent in spatially chopped star images resulting from the telescope's movable secondary mirror. Operation of the sensor is under the control of a high-performance microcomputer that provides both autonomy and flexibility in a guidance application.

Salomon, P. M.↗

Predicting vapor liquid equilibria using density functional theory: A case study of argon

Predicting vapor liquid equilibria (VLE) of molecules governed by weak van der Waals (vdW) interactions using the first principles approach is a significant challenge. Due to the poor scaling of the post Hartree-Fock wave function theory with system size/basis functions, the Kohn-Sham density functional theory (DFT) is preferred for systems with a large number of molecules. However, traditional DFT cannot adequately account for medium to long range correlations which are necessary for modeling vdW interactions. Recent developments in DFT such as dispersion corrected models and nonlocal van der Waals functionals have attempted to address this weakness with a varying degree of success. In this work, we predict the VLE of argon and assess the performance of several density functionals and the second order Møller-Plesset perturbation theory (MP2) by determining critical and structural properties via first principles Monte Carlo simulations. PBE-D3, BLYP-D3, and rVV10 functionals were used to compute vapor liquid coexistence curves, while PBE0-D3, M06-2X-D3, and MP2 were used for computing liquid density at a single state point. Here, the performance of the PBE-D3 functional for VLE is superior to other functionals (BLYP-D3 and rVV10). At T = 85 K and P = 1 bar, MP2 performs well for the density and structural features of the first solvation shell in the liquid phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of downscaled wind speeds and parameterised gusts for recent and historical windstorms in Switzerland

Assessments of local-scale windstorm hazard require highly resolved spatial information on wind speeds and gusts. In this study, maximum (peak) sustained wind speeds on a 3-km horizontal grid over Switzerland are obtained by dynamical downscaling from the Twentieth Century Reanalysis (20CR) employing the Weather Research and Forecasting (WRF) model. Subsequently, simulated peak gusts are derived using four wind gust parameterizations (WGPs). Evaluations against observations at 63 locations in complex terrain include four high-impact windstorms (occurring in 1919, 1935, 1990, and 1999) and 14 recent windstorms (occurring between 1993 and 2011). Peak sustained wind speeds and directions are generally well simulated, although wind speeds are mostly overestimated. In general, performance and skill measures are best for locations on the Swiss Plateau and inferior for Alpine mountain and valley locations. An independent ERA-Interim WRF downscaling configuration produces overall comparable results, implying that the 20CR ensemble mean is a reliable data set in dynamical downscaling exercises. The four evaluated WGPs largely reproduce the observed gustiness, although the timing and magnitude of the peak gusts are not regularly captured. None of the WGPs stands out as single best for the complex topography of Switzerland. Differences among the WGPs are small compared to the biases inherited from the sustained-wind part in the WGP formulations. All WGPs transform overestimated peak sustained winds into underestimated peak gusts, which points to an underrepresentation of the turbulent part in the WGP formulations. The range of simulated peak gusts from downscaling all 20CR ensemble members does not reliably include the observed peak gust, indicating limited benefit in applying an ensemble approach. Despite the limitations, we infer that with spatial optimisations of the simulation (e.g. by bias correction or adaptation of the WGP schemes), downscaling of 20CR input is an efficient option for high-resolution assessments of windstorm hazard and risk in Switzerland.

20CR↗

Probing Millisecond Pulsar Emission Geometry Using Light Curves From the Fermi Large Area Telescope

An interesting new high-energy pulsar sub-population is emerging following early discoveries of gamma-ray millisecond pulsars (MSPs) by the Fermi Large Area Telescope (LAT). We present results from 3D emission modeling, including the Special Relativistic effects of aberration and time-of-flight delays and also rotational sweepback of 13-field lines, in the geometric context of polar cap (PC), slot gap (SG), outer gap (OG), and two-pole caustic (TPC) pulsar models. In contrast to the general belief that these very old, rapidly-rotating neutron stars (NSs) should have largely pair-starved magnetospheres due to the absence of significant pair production, we find that most of the light curves are best fit by SG and OG models, which indicates the presence of narrow accelerating gaps limited by robust pair production -- even in these pulsars with very low spin-down luminosities. The gamma-ray pulse shapes and relative phase lags with respect to the radio pulses point to high-altitude emission being dominant for all geometries. We also find exclusive differentiation of the current gamma-ray MSP population into two MSP sub-classes: light curve shapes and lags across wavebands impose either pair-starved PC (PSPC) or SG / OG-type geometries. In the first case, the radio pulse has a small lag with respect to the single gamma-ray pulse, while the (first) gamma-ray peak usually trails the radio by a large phase offset in the latter case. Finally, we find that the flux correction factor as a function of magnetic inclination and observer angles is typically of order unity for all models. Our calculation of light curves and flux correction factor f(_, _, P) for the case of MSPs is therefore complementary to the "ATLAS paper" of Watters et al. for younger pulsars.

Venter, Christo↗

Interaction-induced velocity renormalization in magic-angle twisted multilayer graphene

Abstract Twistronics heterostructures provide a novel route to control the electronic single particle velocity and thereby to engineer strong effective interactions. Here we show that the reverse may also hold, i.e. that these interactions strongly renormalize the band structure. We demonstrate this mechanism for alternating-twist magic-angle three- and four-layer graphene at charge neutrality and in the vicinity of a phase transition which can be described by an Ising Gross-Neveu critical point corresponding, e.g. to the onset of valley Hall or Hall order. While the non-interacting model displays massless Dirac excitations with strongly different velocities, we show that interaction corrections make them equal in the infrared. However, the renormalization group flow of the velocities and of the coupling to the critical bosonic mode is strongly non-monotonic and dominated by the vicinity of a repulsive fixed point. We predict experimental consequences of this theory for tunneling and transport experiments and discuss the expected behavior at other quantum critical points, including those corresponding to intervalley coherent ordering.

Classen, Laura↗

Near conformal perturbation theory in SYK type models

We present a systematic procedure to extract the dynamics of the low energy soft mode in SYK type models with a single energy scale J and emergent reparametrization symmetry in the IR. This is given in the framework of the perturbative scheme of arXiv:1608.07567 based on a specific (off-shell) breaking of conformal invariance in the UV, adjusted to yield the exact large-N saddle point. While this breaking term formally vanishes on-shell, it has a non-trivial effect on correlation functions and the effective action. In particular, it leads to the Schwarzian action with a specific coupling to bi-local matter. The method is applied to the evaluation of O(1) corrections to the correlation function of bi-locals. As a byproduct we confirm precise agreement with the explicit, symmetry breaking procedure. We provide a verification in the large q limit (Liouville theory), where the correlators can be calculated exactly at all length scales. In this case, our scheme illuminates how the enhanced O(J) and the subleading O(1) contributions originate from the Schwarzian dynamics of the soft mode and its interaction with h = 2 (bi-local) matter.

1/N expansion↗

Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC sequences. For all phantoms and plans, time-resolved (10 Hz) ion chamber dose was collected. In addition, coronal (XY) films were exposed in the cube phantom to a VMAT beam with two different starting phases, and compared to the reconstructed motion-perturbed dose planes. Results: For the X or Y motions with the moving strip and geometrical phantoms, the maximum difference between perturbation-reconstructed and ion chamber doses did not exceed 1.9%, and the average for any motion pattern/starting phase did not exceed 1.3%. For the VMAT plans on the cubic and thoracic phantoms, one point exhibited a 3.5% error, while the remaining five were all within 1.1%. Across all the measurements (N = 22), the average disagreement was 0.5 {+-} 1.3% (1 SD). The films exhibited {gamma}(3%/3 mm) passing rates {>=}90%. Conclusions: The dose to an arbitrary moving voxel in a patient can be estimated with acceptable accuracy for a VMAT delivery, by performing a single QA measurement with a cylindrical phantom and applying two consecutive perturbations to the TPS-calculated patient dose. The first one accounts for the differences between the planned and delivered static doses, while the second one corrects for the motion.

60 APPLIED LIFE SCIENCES↗

Waste Management Improvement Initiatives at Atomic Energy of Canada Limited - 13091

Atomic Energy of Canada Limited's (AECL) Chalk River Laboratories (CRL) has been in operation for over 60 years. Radioactive, mixed, hazardous and non-hazardous wastes have been and continue to be generated at CRL as a result of research and development, radioisotope production, reactor operation and facility decommissioning activities. AECL has implemented several improvement initiatives at CRL to simplify the interface between waste generators and waste receivers: - Introduction of trained Waste Officers representing their facilities or activities at CRL; - Establishment of a Waste Management Customer Support Service as a Single-Point of Contact to provide guidance to waste generators for all waste management processes; and - Implementation of a streamlined approach for waste identification with emphasis on early identification of waste types and potential disposition paths. As a result of implementing these improvement initiatives, improvements in waste management and waste transfer efficiencies have been realized at CRL. These included: 1) waste generators contacting the Customer Support Service for information or guidance instead of various waste receivers; 2) more clear and consistent guidance provided to waste generators for waste management through the Customer Support Service; 3) more consistent and correct waste information provided to waste receivers through Waste Officers, resulting in reduced time and resources required for waste management (i.e., overall cost); 4) improved waste minimization and segregation approaches, as identified by in-house Waste Officers; and 5) enhanced communication between waste generators and waste management groups. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wavefront sensing at X-ray free-electron lasers

Here a direct comparison is made between various X-ray wavefront sensing methods with application to optics alignment and focus characterization at X-ray free-electron lasers (XFELs). Focus optimization at XFEL beamlines presents unique challenges due to high peak powers as well as beam pointing instability, meaning that techniques capable of single-shot measurement and that probe the wavefront at an out-of-focus location are desirable. The techniques chosen for the comparison include single-phase-grating Talbot interferometry (shearing interferometry), dual-grating Talbot interferometry (moiré deflectometry) and speckle tracking. All three methods were implemented during a single beam time at the Linac Coherent Light Source, at the X-ray Pump Probe beamline, in order to make a direct comparison. Each method was used to characterize the wavefront resulting from a stack of beryllium compound refractive lenses followed by a corrective phase plate. In addition, difference wavefront measurements with and without the phase plate agreed with its design to within λ/20, which enabled a direct quantitative comparison between methods. Finally, a path toward automated alignment at XFEL beamlines using a wavefront sensor to close the loop is presented.

42 ENGINEERING↗

Reduced Common-Mode Voltage PWM Scheme for Full-SiC Three-Level Uninterruptible Power Supply With Small DC-Link Capacitors

In this article, a pulsewidth modulation (PWM) scheme for three-level full-SiC uninterruptible power supplies is developed to achieve a high power density. Two key passive components are selected for size reduction of the ac-ac stage: common-mode (CM) EMI filter, and dc-link capacitors. To reduce the CM noise, a new vector combination is proposed based on synchronous switching among three-phases. The proposed combinations align CM voltage (CMV) to be a single pulse per switching period. Owing to the simple shape, CMV cancellation between a three-level rectifier and inverter can be maximally utilized. A transition between the three combinations can control the drift of neutral point voltage. An equivalent carrier-based implementation is developed. Second, a simple algorithm to compensate neutral point voltage fluctuation is proposed both for differential mode (DM) and CM output voltage. Low-order harmonics on three-phase currents and an additional high-frequency CM noise by misaligned switching instant can be eliminated. The proposed compensation can be implemented by a simple correction on carrier slopes and injected zero-sequence voltage. The proposed PWM scheme is verified with 20-kW full-SiC UPS switching at 60 kHz with 140 μF dc-link capacitors.

42 ENGINEERING↗

A level set method for cupping artifact correction in cone-beam CT

Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts in CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts.

60 APPLIED LIFE SCIENCES↗

Analyzing the Operational Behavior of the Alignment and Phasing System of the Thirty Meter Telescope using SysML

The Alignment and Phasing System (APS) of the Thirty Meter Telescope (TMT) is responsible for positioning individual segments of the primary mirror, as well as the secondary and tertiary mirrors. Given its essential role, understanding the as-speci ed behavior and verifying related requirements is vital to the correct operation of the TMT. Analyzing the behavior of APS is challenging due to the variety of interactions with other subsystems. This paper presents results from developing an integrated system model that captures the structure, behavior, and requirements in a formal modeling language to enable automated veri cation using appropriate solvers. Speci cally, demonstrated and discussed are the results of applying a Systems Modeling Language (SysMLTM) based approach in which operational modes, behavior speci cations and use case scenarios are used for the purpose of verifying requirements on timing, power, and pointing error through system-level simulation using a single, integrated model.

Troy, Mitchell↗

X-ray pulse preserving single-shot optical cross-correlation method for improved experimental temporal resolution

We measured the relative arrival time between an optical pulse and a soft x-ray pulse from a free-electron laser. This femtosecond cross-correlation measurement was achieved by observing the change in optical reflectivity induced through the absorption of a fraction of the x-ray pulse. The main x-ray pulse energy remained available for an independent pump-probe experiment where the sample may be opaque to soft x-rays. The method was employed to correct the two-pulse delay data from a canonical pump-probe experiment and demonstrate 130 {+-} 20 fs (FWHM) temporal resolution. We further analyze possible timing jitter sources and point to future improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermoacoustic range verification in the presence of acoustic heterogeneity and soundspeed errors - Robustness relative to ultrasound image of underlying anatomy

Purpose: To demonstrate robustness of thermooacoustic range verification to acoustic heterogeneity and discrepancies between assumed and true propagation speed, i.e., soundspeed errors. Methods: A beam sweeper was used to deliver 250 ns pulses that deposited 0.26 Gy of 16 MeV protons and 2.3 Gy of 60 MeV helium ions into water and oil targets, respectively. Thermoacoustic signals were detected by a 96-channel ultrasound array with a 1-4 MHz sensitivity band (-6 dB), bandpass filtered and backprojected to create thermoacoustic images in the plane of the ultrasound array. The same soundspeed and transducer array were used to estimate range and generate the ultrasound images onto which Bragg peak locations were overlaid. An air-gap phantom that displaced the Bragg peak by 6.5 mm demonstrated accuracy. Robustness to soundspeed errors was demonstrated in a waterbath as the assumed propagation speed scanner setting was altered by +/- 5%. Tissue-mimicking gelatin and a bone sample were introduced to demonstrate robustness to acoustic heterogeneity relative to ultrasound images of the underlying morphology. Results: Single ion pulse measurements sufficed during the helium run, but signal averaging was required for protons. Moreover, range and entry point into the target were estimated from data collected by transducers placed at least 6 cm distal to the Bragg peak. When ultrasound images depicted the air-target interface where the beam enters, estimates of the entry point agreed with ultrasound images and range estimates agreed with Monte Carlo simulations to within 300 mu m, even when thermoacoustic emissions traveled through a strongly scattering bone sample. Estimated Bragg peak locations were translated 6.5 mm by the air-gap phantom and correctly identified scenarios when the beam stopped inside the bone. Conclusions: Soundspeed errors dilate and acoustic heterogeneities deform ultrasound images. When thermoacoustic receivers are co-located with the ultrasound imaging array, the same transformations shift thermoacoustic range estimates. Hence, thermoacoustic range verification is robust relative to ultrasound images of underlying anatomy. When the treatment target is visible in ultrasound, e.g., prostate, online thermoacoustic range estimates could verify that the treatment spot is inside the target.

47 OTHER INSTRUMENTATION↗

Multiphenomenology explosion monitoring (MultiPEM): a general framework for data interpretation and yield estimation

SUMMARY An underground nuclear explosion (UNE) couples mechanical energy into crustal rock, which propagates as seismic and acoustic waves. These different physical phenomena transport, by different pathways, to standoff detectors at varying distances. The transport pathways attenuate the original signal but in different ways. Enabled by correct statistical weighting, signal attenuation models can be used to combine these disparate sensor data to estimate the yield of an UNE. Contemporaneous statistical models, used in yield estimation, can be improved with an advanced partition of error for these physical signal propagation models. We present an advanced multivariate approach to error modelling of multiphenomenology physical signatures. In addition to measurement error, our error model represents physical model biases as random with a physics-based covariance structure. To illustrate this proposed framework, we demonstrate the estimation of explosion yield using openly available seismic and acoustic data from chemical single-point explosions.

Williams, Brian J.↗

Antisite Pairs Suppress the Thermal Conductivity of BAs

BAs was predicted to have an unusually high thermal conductivity with a room temperature value of 2000 W m –1 K –1 , comparable to that of diamond. However, the experimentally measured thermal conductivity of BAs single crystals is still lower than this value. To identify the origin of this large inconsistency, we investigate the lattice structure and potential defects in BAs single crystals at the atomic scale using aberration-corrected scanning transmission electron microscopy (STEM). Rather than finding a large concentration of As vacancies ( V As ), as widely thought to dominate the thermal resistance in BAs, our STEM results show an enhanced intensity of some B columns and a reduced intensity of some As columns, suggesting the presence of antisite defects with As B (As atom on a B site) and B As (B atom on an As site). Additional calculations show that the antisite pair with As B next to B As is preferred energetically among the different types of point defects investigated and confirm that such defects lower the thermal conductivity for B As . Using a concentration of 1.8(8)% (6.6 ± 3.0 × 10 20 cm –3 in density) for the antisite pairs estimated from STEM images, the thermal conductivity is estimated to be 65–100 W m –1 K –1 , in reasonable agreement with our measured value. Our study suggests that As B –B As antisite pairs are the primary lattice defects suppressing thermal conductivity of B As . Possible approaches are proposed for the growth of high-quality crystals or films with high thermal conductivity. In conclusion by employing a combination of state-of-the-art synthesis, STEM characterization, theory, and physical insight, this work models a path toward identifying and understanding defect-limited material functionality.

36 MATERIALS SCIENCE↗

Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500

Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm{sup 2} measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor k{sub NR} for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1% over the range from 5 to 1000 MU. The effective point of measurement of the OD1500 for dose measurements in RW3 phantoms was determined to be (8.7 ± 0.2) mm below its front surface. Output factors showed deviations below 1% for field sizes exceeding 4 × 4 cm{sup 2}. The dose per pulse dependence was smaller than 0.4% for doses per pulse from 0.2 to 1 mGy. The energy dependence of the array did not exceed ±0.9%. The parameter σ of the Gaussian lateral dose response function was determined as σ{sub 6MV} = (2.07 ± 0.02) mm for 6 MV and σ{sub 15MV} = (2.09 ± 0.02) mm for 15 MV. An IMRT verification showed passing rates well above 90% for a local 3 mm/3% criterion. Conclusions: The OD1500 array’s dosimetric properties showed the applicability of the array for clinical dosimetry with the possibility to increase the spatial sampling frequency and the coverage of a dose distribution with the sensitive areas of ionization chambers by merging two measurements.

07 ISOTOPE AND RADIATION SOURCES↗

THE ORBIT, ROTATION, AND GRANULATION OF THE G7 GIANT β Her

The G7 IIIa single-lined spectroscopic binary, β Her, is studied with high-resolution, high-signal-to-noise spectra taken over 10 seasons from 23MR2000 to 10MY2009. Absolute radial velocities, corrected for convective blueshifts, are determined and new orbital parameters are derived. Line-depth ratios are used to measure temperature variation ∼2 K. A Fourier analysis is done for the line broadening, yielding a projected rotation velocity of 3.27 ± 0.20 km s{sup -1} and a radial–tangential macroturbulence dispersion of 6.43 ± 0.08 km s{sup -1}. The “C” shaped bisector of Fe i λ 6253 has its blue-most point at a relative flux level of 0.52, consistent with what is expected from β Her’s absolute magnitude. The third-signature plot indicates granulation velocities 20% larger than the Sun’s. Mapping the λ 6253 line bisector onto the third-signature curve results in a flux deficit of 12.6 ± 1.0% that can be interpreted as arising from a temperature difference between granules and inter-granular lanes of 132 K. The flux deficit peaks near 5.5 km s{sup -1} from the line center, suggesting the velocity difference between granules and lanes is ∼20% larger than that found for recently analyzed K giants.

79 ASTRONOMY AND ASTROPHYSICS↗