Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Wavelength Dependence of Solar Irradiance Enhancement During X-class Flares and Its Influence on the Upper Atmosphere

The wavelength dependence of solar irradiance enhancement during flare events is one of the important factors in determining how the Thermosphere-Ionosphere (TI) system responds to flares. To investigate the wavelength dependence of flare enhancement, the Flare Irradiance Spectral Model (FISM) was run for 61X-class flares. The absolute and the percentage increases of solar irradiance at flare peaks, compared to pre-flare conditions, have clear wavelength dependences. The 0-4 nm irradiance increases much more ((is) approximately 680 on average) than that in the 14-25 nm waveband ((is) approximately 65 on average), except at 24 nm ( (is) approximately 220). The average percentage increases for the 25-105 nm and 122-190 nm wave bands are approximately 120 and approximately 35, respectively. The influence of 6 different wavebands (0-14 nm, 14-25 nm, 25-105 nm, 105-120 nm, 121.56 nm,and122-175 nm) on the thermosphere was examined for the October 28th, 2003 flare (X17-class) event by coupling FISM with the National Center for Atmospheric Research (NCAR) Thermosphere-Ionosphere-Electrodynamics General Circulation Model(TIE-GCM) under geomagnetically quiet conditions (Kp=1). While the enhancement in the0-14nm waveband caused the largest enhancement of the globally integrated solar heating, the impact of solar irradiance enhancement on the thermosphere at 400 km is largest for the 25-105 nm waveband (EUV), which accounts for about 33 K of the total 45 K temperature enhancement, and approximately 7.4% of the total approximately 11.5% neutral density enhancement. The effect of 122-175 nm flare radiation on the thermosphere is rather small. The study also illustrates that the high-altitude thermospheric response to the flare radiation at 0-175 nm is almost a linear combination of the responses to the individual wavebands. The upper thermospheric temperature and density enhancements peaked 3-5 h after the maximum flare radiation.

FISM↗

Space Plasma Ion Processing of the Lunar Soil: Modeling of Radiation-Damaged Rim Widths on Lunar Grains

Chemically and microstructurally complex altered rims around grains in the finest size fraction (<20 micron) of the lunar regolith are the result of multi-stage processes involving both solar ion radiation damage and nanoscale deposition of impact or sputter-derived vapors. The formation of the rims is an important part of the space weathering process, and is closely linked to key changes in optical reflectance and other bulk properties of the lunar surface. Recent application of field-emission scanning transmission electron microscope techniques, including energy dispersive X-ray spectral imaging, is making it easier to unravel the "nano-stratigraphy" of grain rims, and to delineate the portions of rims that represent Radiation-Amorphized (RA) host grain from overlying amorphous material that represents vapor/sputter deposits. For the portion of rims formed by host grain amorphization (henceforth called RA rims), we have been investigating the feasibility of using Monte Carlo-type ion-atom collision models, combined with experimental ion irradiation data, to derive predictive numerical models linking the width of RA rims to the grain s integrated solar ion radiation exposure time.

Chamberlin, S.↗

Characterization of MODIS Solar Diffuser On-orbit Degradation

MODIS reflective solar bands (RSB) are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the instrument vendor using reference samples traceable to NIST reflectance standards. Its on-orbit degradation is regularly monitored by the SDSM. It consists of a solar integration sphere (SIS) with 9 filtered detectors with wavelengths ranging from 0.41 to 0.94 micrometer, a rotating mirror assembly, and an electronics module. During each SD/SDSM calibration, the SDSM views the sunlight directly and the sunlight diffusely reflected from the SD panel. The time series of SDSM measurements (ratio of the SD view response to the Sun view response) is used to compute the SD BRF degradation at each SDSM detector wavelength. Since launch Terra MODIS has operated for more than seven years and Aqua for nearly five years. The SD panel on each MODIS instrument has experienced noticeable degradation with the largest changes observed in the VIS spectral region. Following a brief description of the MODIS RSB calibration methodology and SD/SDSM operational activities, this paper illustrates the SD on-orbit degradation results for both Terra and Aqua MODIS. It discusses the impacts on the SD RF degradation due to sensor operational conditions and SD solar exposure time. For Aqua MODIS, operated under the same conditions, the SD annual degradation rate is approximately 2.9% at 0.41 micrometers, 1.6% at 0.47 micrometers, and less than 1.1% at wavelengths above 0.53 micrometers. For Terra MODIS, however, an SD door (SDD) related anomaly in May 2003 had led to a decision to keep the SDD permanently at its open position. Since then its SD has experienced a much faster SD degradation rate.

Xiong, X.↗

Short-Term Global Horizontal Irradiance Forecasting Based on Sky Imaging and Pattern Recognition

Accurate short-term forecasting is crucial for solar integration in the power grid. In this paper, a classification forecasting framework based on pattern recognition is developed for 1-hour-ahead global horizontal irradiance (GHI) forecasting. Three sets of models in the forecasting framework are trained by the data partitioned from the preprocessing analysis. The first two sets of models forecast GHI for the first four daylight hours of each day. Then the GHI values in the remaining hours are forecasted by an optimal machine learning model determined based on a weather pattern classification model in the third model set. The weather pattern is determined by a support vector machine (SVM) classifier. The developed framework is validated by the GHI and sky imaging data from the National Renewable Energy Laboratory (NREL). Results show that the developed short-term forecasting framework outperforms the persistence benchmark by 16% in terms of the normalized mean absolute error and 25% in terms of the normalized root mean square error.

14 SOLAR ENERGY↗

Final Technical Report

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full phase function versus using approximations of single scattering properties. In a related study, cloud microphysical and radiation data from two field experiments were compared measured irradiances with the modeled counterpart, using various 3D cloud models as input for two 3D radiative transfer models. Two papers were published. Direct measurement of aerosol radiative forcing efficiency - The SSFR and the NASA Ames 14-channel Airborne Tracking Sunphotometer (AATS-14) made simultaneous measurements from the Sky Research J-31 aircraft during NEAQS-ITCT, with nineteen missions over the Gulf of Maine between 12 July and 8 August 2004. SSFR and AATS measurements were used to derive the change in net spectral irradiance per change in aerosol optical depth as measured along horizontal flight legs: dF/d(AOD), or aerosol radiative forcing efficiency [W m{sup -2} AOD{sup -1}]. Unlike ground-based measurements of direct aerosol radiative forcing which rely upon the advection of various air masses over a measurement site during an extended period of time, the airborne method has the advantage of being quasi-instantaneous. Ten cases were found to be well suited for analysis using this gradient forcing method, and they exhibited a high degree of variability in the derived aerosol forcing efficiency, likely the result of changing aerosol characteristics with changing airmass during the experimental period. Over the integrated solar spectrum the mean instantaneous forcing was -135 W m{sup -2}. Converting to a 24 hour average, this equates to a forcing efficiency of -83 Wm{sup -2}, a magnitude similar to that observed during INDOEX. Variability among the cases examined was attributed to differences in aerosol single scattering albedo and this quantity was derived for each case based upon best fit between measured and modeled forcing efficiency. The details of this research have been summarized in a paper [Redemann, Pilewskie, et al., 2006].

60 APPLIED LIFE SCIENCES↗

Thermoeconomic analysis of residential rooftop photovoltaic systems with integrated energy storage and resulting impacts on electrical distribution networks

This paper investigates residential rooftop photovoltaic (PV) systems for long-term thermoeconomic benefits from PV homeowners’ perspectives and for impacts on the electrical distribution network from grid operators’ perspectives. The costs of generating electricity from grid-connected PV systems are studied with and without energy storage at the PV homeowners’ sites. Three selling scenarios for excess PV energy conversion are considered: net metering, wholesale pricing, and no payback. PV systems in Utah are utilized as case studies in this analysis. The presence of PV systems gives homeowners economic benefits such as reduced annual electricity bills. However, the levelized costs of electricity are considerably higher than the weighted electricity price in Utah. Currently, the addition of energy storage only benefits customers in Utah under the no payback policy. The impacts of PV systems toward electrical distribution networks are then studied on a distribution test system. Excess PV generation from residential PV systems causes voltage rise in the electrical distribution network. The results from this paper can educate consumers about the lifetime benefit of integrating solar energy into their homes. For grid operators, residential PV systems with energy storage can reduce the negative impacts on the grid compared with high PV penetration alone.

14 SOLAR ENERGY↗

Benchmarking nanoparticulate metal oxide electrocatalysts for the alkaline water oxidation reaction

Nanoparticulate metal-oxide catalysts are among the most prevalent systems for alkaline water oxidation. However, comparisons of the electrochemical performance of these materials have been challenging due to the different methods of attachment, catalyst loadings, and electrochemical test conditions reported in the literature. Here in this paper, we have leveraged a conventional drop-casting method that allows for the successful adhesion of a wide range of nanoparticulate catalysts to glassy-carbon electrode surfaces. We have applied this adhesion method to prepare catalyst films from 16 crystalline metal-oxide nanoparticles with a constant loading of 0.8 mg cm -2 , and evaluated the resulting nanoparticulate films for the oxygen evolution reaction under conditions relevant to an integrated solar fuels device. In general, the activities of the adhered nanoparticulate films are similar to those of thin-film catalysts prepared by electrodeposition or sputtering, achieving 10 mA cm -2 current densities per geometric area at overpotentials of ~0.35–0.5 V.

36 MATERIALS SCIENCE↗

Application of an automated wireless structural monitoring system for long-span suspension bridges

This paper describes an automated wireless structural monitoring system installed at the New Carquinez Bridge (NCB). The designed system utilizes a dense network of wireless sensors installed in the bridge but remotely controlled by a hierarchically designed cyber-environment. The early efforts have included performance verification of a dense network of wireless sensors installed on the bridge and the establishment of a cellular gateway to the system for remote access from the internet. Acceleration of the main bridge span was the primary focus of the initial field deployment of the wireless monitoring system. An additional focus of the study is on ensuring wireless sensors can survive for long periods without human intervention. Toward this end, the life-expectancy of the wireless sensors has been enhanced by embedding efficient power management schemes in the sensors while integrating solar panels for power harvesting. The dynamic characteristics of the NCB under daily traffic and wind loads were extracted from the vibration response of the bridge deck and towers. These results have been compared to a high-fidelity finite element model of the bridge.

42 ENGINEERING↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SIRENOpt.jl

SAND2026-22945O SIRENOpt.jl is a Julia software package for prototype hybrid power, storage, and platform dynamics. It integrates solar, wind, wave, hydrokinetic, diesel, generator, converter, battery, hydrogen, desalination, mooring, and floating-platform model interfaces in an automatic-differentiation-friendly simulation framework. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

NREL's HydroGEN Photoreactor Platform Design and Characterization

This technical report details the design, fabrication, and construction of a flow-through photoreactor developed at The National Renewable Energy Laboratory (NREL). The photoreactor is designed to facilitate indoor or outdoor testing on photoelectrochemical or integrated solar water splitting devices. The photoreactor design described here is based on a previous demonstration. The photoreactor version described herein contains several advanced design features that include: 1) Chassis-chuck two-part design, 2) Separable counter electrode compartments (here, the counter electrodes are anodes), 3) Reduced electrode separation to reduce electrolyte resistance, 4) Improved flow pattern for bubble removal, 5) Mounting for spectroradiometer receptor, 6) Fresnel lens and collimating tube attachments. The photoreactor presented here was designed primarily to accommodate photocathode materials in an illuminated compartment and a dark anode as the oxygen evolution catalyst. The build materials were thus chosen to for acid electrolyte compatibility. Other embodiments could accommodate a photoanode with dark hydrogen evolution catalyst and other build materials for alkaline compatibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Providencia Island High-Level Power System Capacity Expansion Analyses [Slides]

Results of a high level cost-benefit analysis using HOMER Pro software are presented for Providencia Island, Colombia. The analysis focuses on integrating solar photovoltaics (PV) and a battery energy storage system (BESS) into an existing diesel-only remote power system. The analysis uses fuel costs and discount rates provided by the stakeholders and NREL-derived capital cost estimates.

14 SOLAR ENERGY↗

Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the Ukrainian version of this report, see NREL/TP-7A40-90360 (https://www.nrel.gov/docs/fy24osti/90360.pdf).

14 SOLAR ENERGY↗

ТЕХНІКО-ЕКОНОМІЧНИЙ АНАЛІЗ ПОТЕНЦІАЛУ ІНТЕГРАЦІЇ РОЗПОДІЛЕНИХ ЕНЕРГЕТИЧНИХ РЕСУРСІВ ДЛЯ ВОДОКАНАЛУ М.ЧЕРВОНОГРАД В УКРАЇНІ [Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine] (Ukrainian Translation)

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the English version of this report, see NREL/TP-7A40-89599 (https://www.nrel.gov/docs/fy24osti/89599.pdf).

14 SOLAR ENERGY↗

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗