Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Search for systematic behavior of incomplete-fusion probability and complete-fusion suppression induced by {sup 9}Be on different targets

We present a trial to obtain a systematic behavior of the results available in the literature on the complete and incomplete fusion induced by the weakly bound projectile {sup 9}Be on targets with different masses and/or charges. We stress that although the incomplete-fusion probability and the complete-fusion suppression are very closely related quantities, the first is an experimental value whereas the later is model dependent. A trend of systematic behavior for the incomplete-fusion probability as a function of the target charge is achieved, but not for the complete-fusion suppression.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

α -decay energies of superheavy nuclei: Systematic trends

Background: New superheavy nuclei are often identified through their characteristic α -decay energies, which requires accurate calculations of Q α values. While many Q α predictions are available, little is known about their uncertainties, and this makes it difficult to carry out extrapolations to as-yet-unknown systems. Purpose: This work aims to analyze several models, compare their predictions to available experimental data, and study their performance for the unobserved α-decay chains of 296 120 and 298 120, which are of current experimental interest. Our quantified results will also serve as a benchmark for future, more sophisticated statistical studies. Methods: We use nuclear superfluid density functional theory (DFT) with several Skyrme energy density functionals (EDFs). To estimate systematic model uncertainties, we employ uniform model averaging. Results: We investigated the Q α values for even-even nuclei from Fm to Z = 120 . For well-deformed nuclei between Fm and Ds, we find excellent consistency between different model predictions, and a good agreement with experimental results. For transitional nuclei beyond Ds, intermodel differences grow, resulting in an appreciable systematic error. In particular, our models underestimate Q α for the heaviest nucleus 294 Og. Conclusions The robustness of DFT predictions for well-deformed superheavy nuclei supports the idea of using experimental Q α values, together with theoretical predictions, as reasonable ( Z, A ) indicators. Unfortunately, this identification method is not projected to work well in the region of deformed-to-spherical shape transition as one approaches N = 184 . The use of Q α values in the identification of new superheavy nuclei will benefit greatly from progress in developing both new spectroscopic-quality EDFs and more sophisticated statistical techniques of uncertainty quantification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic improvement of x -dependent unpolarized nucleon generalized parton distributions in lattice-QCD calculation

We present a first study of the effects of renormalization-group resummation (RGR) and leading-renormalon resummation (LRR) on the systematic errors of the unpolarized isovector nucleon generalized parton distribution in the framework of large-momentum effective theory. This work is done using lattice gauge ensembles generated by the MILC Collaboration, consisting of 2 + 1 + 1 flavors of highly improved staggered quarks with a physical pion mass at lattice spacing a ≈ 0.09 fm and a box width L ≈ 5.76 fm . We present results for the nucleon H and E generalized parton distributions (GPDs) with average boost momentum P z ≈ 2 GeV at momentum transfers Q 2 = [ 0 , 0.97 ] GeV 2 at skewness ξ = 0 as well as Q 2 ∈ 0.23 GeV 2 at ξ = 0.1 , renormalized in the modified minimal subtraction ( MS ¯ ) scheme at scale μ = 2.0 GeV , with two- and one-loop matching, respectively. We demonstrate that the simultaneous application of RGR and LRR significantly reduces the systematic errors in renormalized matrix elements and distributions for both the zero and nonzero skewness GPDs, and that it is necessary to include both RGR and LRR at higher orders in the matching and renormalization processes. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Systematics of high temperature perturbation theory: The two-loop electron self-energy in QED

In order to investigate the systematics of the loop expansion in high temperature gauge theories beyond the leading order hard thermal loop (HTL) approximation, we calculate the two-loop electron proper self-energy {Sigma} in high temperature QED. The two-loop bubble diagram of {Sigma} contains a linear infrared divergence. Even if regulated with a nonzero photon mass M of order of the Debye mass, this infrared sensitivity implies that the two-loop self-energy contributes terms to the fermion dispersion relation that are comparable to or even larger than the next-to-leading order (NLO) contributions of the one-loop {Sigma}. Additional evidence for the necessity of a systematic restructuring of the loop expansion comes from the explicit gauge-parameter dependence of the fermion damping rate at both one and two loops. The leading terms in the high temperature expansion of the two-loop self-energy for all topologies arise from an explicit hard-soft factorization pattern, in which one of the loop integrals is hard (p{approx_equal}T), nested inside a second loop integral which is soft (0{<=}p < or approx. T for real parts; p{approx_equal}eT for imaginary parts). There are no hard-hard contributions to the two-loop {Sigma} at leading order at high T. Provided the same factorization pattern holds for arbitrary l loops, the NLO high temperature contributions to the electron self-energy come from l-1 hard loops factorized with one soft loop integral. This hard-soft pattern is a necessary condition for the resummation over l to coincide with the one-loop self-energy calculated with HTL dressed propagators and vertices, and to yield the complete NLO correction to {Sigma} at scales {approx}eT, which is both infrared finite and gauge invariant. We employ spectral representations and the Gaudin method for evaluating finite temperature Matsubara sums, which facilitates the analysis of multiloop diagrams at high T.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic uncertainties in the determination of the local dark matter density

A precise determination of the local dark matter density and an accurate control over the corresponding uncertainties are of paramount importance for dark matter (DM) searches. Using very recent high-resolution numerical simulations of a Milky Way like object, we study the systematic uncertainties that affect the determination of the local dark matter density based on dynamical measurements in the Galaxy. In particular, extracting from the simulation with baryons the orientation of the Galactic stellar disk with respect to the DM distribution, we study the DM density for an observer located at {approx}8 kpc from the Galactic center on the stellar disk, {rho}{sub 0}. This quantity is found to be always larger than the average density in a spherical shell of the same radius {rho}{sub 0}, which is the quantity inferred from dynamical measurements in the Galaxy, and to vary in the range {rho}{sub 0}/{rho}{sub 0}=1.01-1.41. This suggests that the actual dark matter density in the solar neighborhood is on average 21% larger than the value inferred from most dynamical measurements, and that the associated systematic errors are larger than the statistical errors recently discussed in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mapping extragalactic dark matter annihilation with galaxy surveys: A systematic study of stacked group searches

Dark matter in the halos surrounding galaxy groups and clusters can annihilate to high-energy photons. Recent advancements in the construction of galaxy group catalogs provide many thousands of potential extragalactic targets for dark matter. In this paper, we outline a procedure to infer the dark matter signal associated with a given galaxy group. Applying this procedure to a catalog of sources, one can create a full-sky map of the brightest extragalactic dark matter targets in the nearby Universe (z≲0.03), supplementing sources of dark matter annihilation from within the local group. As with searches for dark matter in dwarf galaxies, these extragalactic targets can be stacked together to enhance the signals associated with dark matter. We validate this procedure on mock Fermi gamma-ray data sets using a galaxy catalog constructed from the DarkSky N-body cosmological simulation and demonstrate that the limits are robust, at O(1) levels, to systematic uncertainties on halo mass and concentration. We also quantify other sources of systematic uncertainty arising from the analysis and modeling assumptions. Lastly, our results suggest that a stacking analysis using galaxy group catalogs provides a powerful opportunity to discover extragalactic dark matter and complements existing studies of Milky Way dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

First systematic study of L-shell opacity at stellar interior temperatures

The first systematic study of opacity dependence on atomic number at stellar interior temperatures is used to evaluate discrepancies between measured and modeled iron opacity [J. E. Bailey et al., Nature (London) 517, 56 (2015)]. High-temperature ( > 180 eV) chromium and nickel opacities are measured with ± 6-10% uncertainty, using the same methods employed in the previous iron experiments. The 10%-20% experiment reproducibility demonstrates experiment reliability. The overall model-data disagreements are smaller than for iron. However, the systematic study reveals shortcomings in models for density effects, excited states, and open L-shell configurations. The 30%-45% underestimate in the modeled quasicontinuum opacity at short wavelengths was observed only from iron and only at temperature above 180 eV. Thus, either opacity theories are missing physics that has nonmonotonic dependence on the number of bound electrons or there is an experimental flaw unique to the iron measurement at temperatures above 180 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Systematic Operating Temperature Differences Between Al-BSF, PERC, and PERT-With-Optimized-Rear-Reflector Solar Mini-Modules Due to Rear Reflectance

Reflecting sub-bandgap light from photovoltaic modules has the potential to improve lifetime energy generation of fielded systems by reducing operating temperature. In this article, the temperature of fielded aluminum back-surface field (Al-BSF) and passivated emitter and rear contact (PERC) mini-modules was monitored every 5 minutes for 75 days along with corresponding meteorological data. Additionally, passivated emitter rear totally diffused (PERT) mini-modules with high-performance sub-bandgap rear reflectors were tested and compared to the state-of-the-art industrial modules. These reflectors consisted of a >300-nm-thick silicon dioxide nanoparticle film with a low refractive index. The impact of reflectance on measured operating temperature was isolated with a previously developed thermal model and quantified as the reflectance-induced median temperature difference between each tested module at representative outdoor conditions (1000 W m -2 , 25 degrees C ambient temperature, and 1.43 m s -1 wind speed). We found that, because of their reflectance differences, PERC modules ran systematically cooler than Al-BSF modules by 1.0 degrees C, whereas the PERT-with-optimized-rear-reflector systematically operated 1.4 degrees C cooler than the Al-BSF module and 0.4 degrees C than the PERC module. We also found that the rear reflector provided the greatest temperature benefit during periods of highest irradiance.

14 SOLAR ENERGY↗

A Systematic Comparison for Consistent Scenario Development Using Microscopic Simulation Software

This study aims to explore a methodology that enables the development of consistent traffic micro simulation for emerging traffic and vehicle control technologies for improved mobility and energy efficiency across different modeling platforms. Researchers might study the same application on different platforms and have the need to benchmark across platforms. However, there lacks a systematic study on simulation software comparison, especially for emerging mobility and energy efficiency applications. For this, a systematic scenario development and evaluation approach is presented and demonstrated to compare scenarios generated in different traffic microsimulation platforms. Network-level and vehicle-level trip performance results of the traffic scenario are evaluated in three microscopic simulation platforms - VISSIM, AIMSUN, and SUMO. The results indicate that the network-level performance is consistent among the three software suites except when the demand is high, where the energy consumption performance varies.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

SYSTEMATIC MULTI-INDEX VALIDATIONS OF SIDI ENGINE FLOW FIELD LES COMPUTATIONS USING CRANK ANGLE-RESOLVED PIV MEASUREMENTS

In-cylinder flow fields make significant impacts on the fuel atomization, fuel mixture formation, and combustion process in spark ignition direct injection (SIDI) engines. In recent years, model-based simulation approaches are preferred in regard to investigating the transient in-cylinder flow field characteristics. Most commonly, the simulation models are validated using single representative flow field at a typical crank angle measured by particle image velocimetry (PIV). However, it provides only limited knowledge about the flow field which is highly three-dimensional and of transient nature. In this study, crank angle-resolved Ply measurements are conducted on three distinct planes inside the cylinder to capture the transient process of flow field characteristics which vary with the crank angle. These three planes consist of one tumble plane through the spark plug tip, one tumble plane along two intake ports, and one swirl plane at 30 mm below the cylinder head. Large eddy simulation (LES) is employed for the numerical computations using the CONVERGE codes. On the basis of large datasets for both temporal and spatial domains, a multi-index systematic validation approach is conducted. Crank angle-resolved calculations of global indices and local indices are implemented using the flow fields velocity data obtained from both PIV and LES on select planes. Global indices reveal the trends in similarities of different crank angle degrees and locations, while local indices give the detail comparison results. In summary, with the systematic multi-index validation approach, the crucial crank angle degrees and locations for model verification will be detected. Furthermore, the corresponding critical flow features are analyzed. Practical guideline of flow field validation is proposed.

Crank angle-resolved PIV↗

Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors

In a previous study [Med. Phys. 35, 1747-1755 (2008)], the authors proposed two direct methods of calculating the replacement correction factors (P{sub repl} or p{sub cav}p{sub dis}) for ion chambers by Monte Carlo calculation. By ''direct'' we meant the stopping-power ratio evaluation is not necessary. The two methods were named as the high-density air (HDA) and low-density water (LDW) methods. Although the accuracy of these methods was briefly discussed, it turns out that the assumption made regarding the dose in an HDA slab as a function of slab thickness is not correct. This issue is reinvestigated in the current study, and the accuracy of the LDW method applied to ion chambers in a {sup 60}Co photon beam is also studied. It is found that the two direct methods are in fact not completely independent of the stopping-power ratio of the two materials involved. There is an implicit dependence of the calculated P{sub repl} values upon the stopping-power ratio evaluation through the choice of an appropriate energy cutoff {Delta}, which characterizes a cavity size in the Spencer-Attix cavity theory. Since the {Delta} value is not accurately defined in the theory, this dependence on the stopping-power ratio results in a systematic uncertainty on the calculated P{sub repl} values. For phantom materials of similar effective atomic number to air, such as water and graphite, this systematic uncertainty is at most 0.2% for most commonly used chambers for either electron or photon beams. This uncertainty level is good enough for current ion chamber dosimetry, and the merits of the two direct methods of calculating P{sub repl} values are maintained, i.e., there is no need to do a separate stopping-power ratio calculation. For high-Z materials, the inherent uncertainty would make it practically impossible to calculate reliable P{sub repl} values using the two direct methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-195: Systematic Constraining of Contralateral Parotid Gland Led to Improved Dosimetric Outcomes for Multi-Field Optimization with Scanning Beam Proton Therapy: Promising Results From a Pilot Study in Patients with Base of Tongue Carcinoma

Purpose: Treatment planning for Intensity Modulated Proton Therapy (IMPT) for head and neck cancer is time-consuming due to the large number of organs-at-risk (OAR) to be considered. As there are many competing objectives and also wide range of acceptable OAR constraints, the final approved plan may not be most optimal for the given structures. We evaluated the dose reduction to the contralateral parotid by implementing standardized constraints during optimization for scanning beam proton therapy planning. Methods: Twenty-four (24) consecutive patients previously treated for base of tongue carcinoma were retrospectively selected. The doses were 70Gy, 63Gy and 57Gy (SIB in 33 fractions) for high-, intermediate-, and standard-risk clinical target volumes (CTV), respectively; the treatment included bilateral neck. Scanning beams using MFO with standardized bilateral anterior oblique and PA fields were applied. New plans where then developed and optimized by employing additional contralateral parotid constraints at multiple defined dose levels. Using a step-wise iterative process, the volume-based constraints at each level were then further reduced until known target coverages were compromised. The newly developed plans were then compared to the original clinically approved plans using paired student t-testing. Results: All 24 newly optimized treatment plans maintained initial plan quality as compared to the approved plans, and the 98% prescription dose coverage to the CTV’s were not compromised. Representative DVH comparison is shown in FIGURE 1. The contralateral parotid doses were reduced at all levels of interest when systematic constraints were applied to V10, V20, V30 and V40Gy (All P<0.0001; TABLE 1). Overall, the mean contralateral parotid doses were reduced by 2.26 Gy on average, a ∼13% relative improvement. Conclusion: Applying systematic and volume-based contralateral parotid constraints for IMPT planning significantly reduced the dose at all dosimetric levels for patients with base of tongue cancer.

60 APPLIED LIFE SCIENCES↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Study of systematic errors of bound-state parameters in SVZ sum rules

We study systematic errors of the ground-state parameters obtained from Shifman-Vainshtein-Zakharov sum rules, making use of the harmonic-oscillator potential model as an example. In this case, one knows the exact solution for the polarization operator, which allows one to obtain both the OPE to any order and the parameters (masses and decay constants) of the bound states. We determine the parameters of the ground state making use of the standard procedures of the method of sum rules and compare the obtained results with the known exact values. We show that, in the situation when the continuum contribution to the polarization operator is not known and is modeled by an effective continuum, the method of sum rules does not allow one to control the systematic uncertainties of the extracted ground-state parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

Computational study of the influence of some systematic factors on the fuel temperature in a very high temperature gas-cooled reactor with prismatic fuel assemblies

The influence of the main systematic factors of overheating (such as nonuniformity of power density and cold leaks of coolant) on the fuel temperatures in a very high temperature gas-cooled reactor NGNP (Next Generation Nuclear Plant) with prismatic fuel blocks is studied. The results of computations show a high sensitivity of the fuel temperatures to systematic factors of overheating. This circumstance indicates the necessity of high-precision three-dimensional modeling of the gas dynamics and heat transfer in the core when designing this type of reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Jet energy measurement and its systematic uncertainty in proton–proton collisions at √s = 7 TeV with the ATLAS detector

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of \(\sqrt{s}=7\) TeV corresponding to an integrated luminosity of \(4.7\) \(\,\,\text{ fb }^{-1}\). Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti-\(k_{t}\) algorithm with distance parameters \(R=0.4\) or \(R=0.6\), and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a \(Z\) boson, for \({20} \le p_{\mathrm {T}}^\mathrm {jet}<{1000}\, ~\mathrm{GeV }\) and pseudorapidities \(|\eta |<{4.5}\). The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region (\(|\eta |<{1.2}\)) for jets with \({55} \le p_{\mathrm {T}}^\mathrm {jet}<{500}\, ~\mathrm{GeV }\). For central jets at lower \(p_{\mathrm {T}}\), the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for \(p_{\mathrm {T}}^\mathrm {jet}> 1\) TeV. The calibration of forward jets is derived from dijet \(p_{\mathrm {T}}\) balance measurements. The resulting uncertainty reaches its largest value of 6 % for low-\(p_{\mathrm {T}}\) jets at \(|\eta |=4.5\). In addition, JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗