Search NASA⌕ Search

SEARCH · Search NASA

Results for “TECHNETIUM 99”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

347 records · Page 20

99 Tc Process Monitoring System In-Lab Performance Characterization

A 99 Tc Process Monitoring (Tc-Mon) System has been designed and built for deployment at the recently constructed 200 West Pump & Treat (200W P&T) Plant in the 200 West Area ZP-1 Operable Unit of the Hanford Site. The plant is operated by CH2M Hill Plateau Remediation Company (CHPRC). The Tc-Mon system was created through collaboration between Pacific Northwest National Laboratory (PNNL) and Burge Environmental, Inc. The design of the new system has been optimized based on experience from an earlier field test (2011) of a prototype system at the 200W-ZP-1 Interim Pump & Treat Plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

Part II: Predicting performance of $\mathrm{DOWEX 21K}$ resin for remediation of comingled contaminants in groundwater

The selectivity of ion exchange (IX) resins for aqueous contaminant removal can be impacted by changing concentrations of competing natural groundwater ions. In a two-part investigation, the Hanford Site 200 West Area pump-and-treat (P&T) facility in Washington State, USA is used as a case study to evaluate the performance of two IX resins for groundwater treatment: Purolite® A532E for pertechnetate (TcO 4 - ) removal, explored in Part I, and DOWEX 21K (DOWEX) for uranium (U) removal. In Part II, DOWEX selectivity for U, as uranyl carbonate species, and uptake kinetics is quantified in a series of laboratory-scale aqueous batch experiments containing Hanford-relevant concentrations of competing anions nitrate (NO 3 - ), sulfate (SO 4 2- ), chloride (Cl - ), and carbonate (CO 3 2- ), as well as co-mingled contaminant TcO 4 - . Here the results demonstrate that DOWEX trimethylammonium functional groups are highly selective for U carbonate species (85–100 % uptake) under all conditions investigated. Only NO 3 - concentrations of 100 mM were shown to decrease U removal, with the extent (85–99 %) depending on competing anion concentrations present in solution. However, at the highest NO 3 - concentrations reported for groundwaters treated at the P&T facility (25 mM), the effect on U uptake is minimal. The batch sorption results are modeled to obtain chloride normalized equilibrium exchange coefficients (K) for predicting DOWEX performance: K SO4--/Cl- = 2.0, K NO3-/Cl- = 5.0, K HCO3-/Cl- = 1.5, K TcO4-/Cl- = 2,000, and K U/Cl- = 50,000. These K values predict little effect of current and future influent chemistries on U removal by DOWEX, where both uranyl carbonate species and TcO 4 - are removed such that effluent concentrations meet groundwater treatment requirements.

54 ENVIRONMENTAL SCIENCES↗

Comparative uptake, translocation, and plant mediated transport of Tc-99, Cs-133, Np-237, and U-238 in Savannah River Site soil columns for the grass species Andropogon virginicus

Here, this study examines the ability of the grass species Andropogon virginicus to alter the subsurface transport and redistribution of a suite of radionuclides ( 99 Tc, 133 Cs (stable analog for 135 Cs and 137 Cs), 237 Np, 238 U) with varying chemical behaviors in a Savannah River Site soil via the use of vegetated and unvegetated soil columns. After an acclimation period, a small volume of solution containing all radionuclides was introduced into the columns via Rhizon© pore water sampling tubes. Plants were grown for an additional 4 weeks before shoots were harvested, and columns were prepared for sampling. Plant presence led to decreased radionuclide release from the columns, mainly due to radionuclide specific combinations of system hydrology differences resulting from plant transpiration as well as plant uptake. For the most mobile radionuclides, 99 Tc followed by 237 Np, plant presence resulted in significantly different soil concentration profiles between vegetated and unvegetated columns, including notable upward migration for 237 Np in columns with plants. Additionally, plant uptake of 99 Tc was the greatest of all the radionuclides, with plant tissues containing an average of 44 % of the 99 Tc, while plant uptake only accounted for <2 % of 237 Np and <0.5 % of 133 Cs and 238 U in the system. Although overall plant uptake of 133 Cs and 238 U were similar, the majority of 133 Cs taken up by plants was associated with 133 Cs already available in the aqueous phase while 238 U uptake was mainly associated with the solid phase, meaning that plant activity resulted in a fraction of the native 238 U being mobilized and thus, made available for plant uptake. Overall, this study quantified the influence of several plant-mediated physical and biogeochemical factors that have significant influence on radionuclide mobility and transport in this complex system which can be further utilized in future system or site-specific environmental transport and risk assessment models.

59 BASIC BIOLOGICAL SCIENCES↗

Oxidative Stability of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste

Technetium (Tc), which exists predominately in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site, is one of the most difficult contaminants to dispose of and/or remediate. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO 4 - , oxidation state +7). However, based on experimentation to-date, a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non-pertechnetate species. The presence of a non pertechnetate species significantly complicates disposition of low-activity waste (LAW), and the development of methods to either convert them to pertechnetate or to separate the non-pertechnetate species directly is needed. The challenge is the uncertainty regarding the nature and stability of the alkaline-soluble, low-valence, non pertechnetate species in the liquid tank waste. One objective of the Tc management project is to address this knowledge gap. This fiscal year (FY) 2015 report summarizes experimental work exploring the oxidative stability of model low-valence Tc(I) tricarbonyl species, derived from the [Tc(CO) 3 ] + moiety. These compounds are of interest due to their implied presence in several Hanford tank waste supernatants. Work in part was initiated in FY 2014, and a series of samples containing non-pertechnetate Tc generated ex situ or in situ in pseudo-Hanford tank supernatant simulant solutions was prepared and monitored for oxidation to Tc(VII) (Levitskaia et al. 2014). This experimentation continued in FY 2015, and new series of samples containing Tc(I) as [Tc(CO) 3 ] + •Ligand was tested. The monitoring method used for these studies was a combination of 99 Tc NMR and EPR spectroscopies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗