Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PARTICLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Deep Space Test Bed for Radiation Studies

A key factor affecting the technical feasibility and cost of missions to Mars or the Moon is the need to protect the crew from ionizing radiation in space. Some analyses indicate that large amounts of spacecraft shielding may be necessary for crew safety. The shielding requirements are driven by the need to protect the crew from Galactic cosmic rays (GCR). Recent research activities aimed at enabling manned exploration have included shielding materials studies. A major goal of this research is to develop accurate radiation transport codes to calculate the shielding effectiveness of materials and to develop effective shielding strategies for spacecraft design. Validation of these models and calculations must be addressed in a relevant radiation environment to assure their technical readiness and accuracy. Test data obtained in the deep space radiation environment can provide definitive benchmarks and yield uncertainty estimates of the radiation transport codes. The two approaches presently used for code validation are ground based testing at particle accelerators and flight tests in high-inclination low-earth orbits provided by the shuttle, free-flyer platforms, or polar-orbiting satellites. These approaches have limitations in addressing all the radiation-shielding issues of deep space missions in both technical and practical areas. An approach based on long duration high altitude polar balloon flights provides exposure to the galactic cosmic ray composition and spectra encountered in deep space at a lower cost and with easier and more frequent access than afforded with spaceflight opportunities. This approach also results in shorter development times than spaceflight experiments, which is important for addressing changing program goals and requirements.

Adams, James H.↗

Morphology and particle size (MaPS) exercise: testing the applications of image analysis and morphology descriptions for nuclear forensics

Image analysis techniques have been applied and shown to be a valuable tool in nuclear forensics analysis. The interlaboratory exercise reported here has tested quantitative and qualitative approaches for characterizing nuclear materials. Particle size, surface features and morphology descriptions were compared by four laboratories on a common image set generated by Scanning Electron Microscopy and Digital Light Microscopy. Quantitative analysis of the image sets through the Morphological Analysis for MAterials software highlighted the strength of image analysis, but also that the application of the software alone can introduce significant bias in the analysis. Qualitative morphology descriptions following the process outlined by Tamasi et al. (J Radioanal Nuclear Chem 307:1611–1619, 2015) were compared with a discussion on the robustness and reproducibility of the results. Finally, future work should continue to focus on proficiency and standardization of image analysis through continued exercises within the extended nuclear forensics community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

The Orion Exploration Flight Test Post Flight Solid Particle Flight Environment Inspection and Analysis

Orbital debris in the millimeter size range can pose a hazard to current and planned spacecraft due to the high relative impact speeds in Earth orbit. Fortunately, orbital debris has a relatively short life at lower altitudes due to atmospheric effects; however, at higher altitudes orbital debris can survive much longer and has resulted in a band of high flux around 700 to 1,500 km above the surface of the Earth. While large orbital debris objects are tracked via ground based observation, little information can be gathered about small particles except by returned surfaces, which until the Orion Exploration Flight Test number one (EFT-1), has only been possible for lower altitudes (400 to 500 km). The EFT-1 crew module backshell, which used a porous, ceramic tile system with surface coatings, has been inspected post-flight for potential micrometeoroid and orbital debris (MMOD) damage. This paper describes the pre- and post-flight activities of inspection, identification and analysis of six candidate MMOD impact craters from the EFT-1 mission.

Miller, Joshua E.↗

Heat Transfer Characteristics of Particle and Air Flow Through Additively Manufactured Lattice Frame Material Based on Octet-Shape Topology

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchanger is a critical component in next-generation concentrating solar power (CSP) plants. The inherently low heat transfer between falling particles and sCO 2 imposes a challenge toward economic justification of levelized cost of electricity produced through solar energy. Introduction of integrated porous media with the walls bounding particle flow has the potential to enhance the overall particle-to-sCO 2 heat exchanger performance. Here, this paper presents an experimental study on heat transfer characterization of additively manufactured lattice frame material based on Octet-shaped unit cell with particles and air as working fluids. The lattice structures were additively manufactured in stainless steel (SS) 316L and SS420 (with 40% bronze infiltration) via Binder jetting process, where the lattice porosities were varied between 0.75 and 0.9. The mean particle diameters were varied from 266 μm to 966 μm. The effective thermal conductivity and averaged heat transfer coefficient were determined through steady-state experiments. It was found that the presence of lattice enhances the effective thermal conductivity by 2–4 times when compared to packed bed of particles alone. Furthermore, for gravity-assisted particle flow through lattice panel, significantly high convective heat transfer coefficients ranging from 200 W/m2K to 400 W/m2K were obtained for the range of particle diameters tested. The superior thermal transport properties of Octet-shape-based lattice frame for particle flow makes it a very promising candidate for particle-to-sCO 2 heat exchanger for CSP application.

14 SOLAR ENERGY↗

A coupled polygonal DEM-LBM technique based on an immersed boundary method and energy-conserving contact algorithm

Here we present a framework of coupling polygonal discrete elements and the lattice Boltzmann method using a direct forcing immersed boundary scheme. In this technique, an energy-conserving contact algorithm is utilized to handle the interactions between convex and concave polygonal particles. The surface of a polygon is represented by discrete boundary points which includes vertices of polygonal particles and/or points interpolated from vertices. The fluid-particle coupling is obtained through the interactions of the boundary points and the imaginary fluid particles using a direct-forcing immersed boundary method. Validations of the proposed technique are made by single particle and multiple arbitrarily-shaped particle sedimentation tests, and the effect of particle shape is illustrated using a drafting-kissing-tumbling benchmark.

42 ENGINEERING↗

Detecting Foreign Particles in Wind Tunnels

Simple scratch test tells whether particles, which distort results, present in test. Detector developed for tests of abrasion resistance of flexible insulation blankets. Now, when detector indicates particles present in test, results interpreted accordingly. Small pits and scratches on metal foil indicate particles struck surface during wind-tunnel test. Detector used in tests of paints and coatings to determine whether abrasive particles present.

Sharp, H. L.↗

The determination and optimization of (rutile) pigment particle size distributions

A light scattering particle size test which can be used with materials having a broad particle size distribution is described. This test is useful for pigments. The relation between the particle size distribution of a rutile pigment and its optical performance in a gray tint test at low pigment concentration is calculated and compared with experimental data.

Richards, L. W.↗

Evaluation of an Electrostatic Dust Removal System with Potential Application in Next-Step Fusion Devices

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 cu mm volume of carbon and tungsten particles were moved in under 5 seconds. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon, and the change in particle distribution over short timescales 1 s).

Friesen, F. Q. L.↗

Particle and Trace Gas Emissions Indices Measured During the 2021 Boeing ecoDemonstrator Emissions Ground Test

We present particle and trace gas emissions indices sampled on the ground at 30 meters behind the CFM LEAP-1B engines of the 2021 Boeing ecoDemonstrator, an Alaska Airlines 737-9 aircraft. Testing was carried out at Boeing Field in Seattle, WA, USA in Fall of 2021. Four different fuels were investigated including a 100% sustainable aviation fuel (SAF), a petroleum-based Jet A fuel, and two SAF blends. Total and non-volatile particle number concentrations were measured with a pair of condensation particle counters with one operating behind a custom-built thermal denuder heated to 350 degrees Celsius. Similarly, total and non-volatile particle number size distributions were measured with a pair of Scanning Mobility Particle Sizers (SMPSs). Non-volatile particle mass was estimated from particle light absorption techniques using an assumed mass absorption coefficient, while particle chemical speciation was measured by an Soot Particle Aerosol Mass Spectrometer (SP-AMS). A detailed list of instruments is given on the project website [1]. Overall, the results are consistent with expectations based on ICAO Emissions Databank certification data for the LEAP-1B with a stark reduction in non-volatile particle number and mass observed for the higher thrust conditions when the combustor was staged. The production of volatile particles under these conditions as well as experimental considerations related to background subtraction methods will be discussed. References: [1] Boeing ecoDemonstrator Science and Engineering Team (2022). 2021 Boeing ecoDemonstrator Emissions Ground Test Dataset

Richard H Moore↗

Particle and Trace Gas Emissions Indices Measured During the 2021 Boeing ecoDemonstrator Emissions Ground Test

We present particle and trace gas emissions indices sampled on the ground at 30 meters behind the CFM LEAP-1B engines of the Boeing ecoDemonstrator 737-9 aircraft. Testing was carried out at Boeing Field in Seattle, WA, USA in Fall of 2021. Four different fuels were investigated including a 100% sustainable aviation fuel (SAF), a petroleum-based Jet A fuel, and two SAF blends. Total and non-volatile particle number concentrations were measured with a pair of condensation particle counters with one operating behind a custom-built thermal denuder heated to 350 degrees Celsius. Similarly, total and non-volatile particle number size distributions were measured with a pair of Scanning Mobility Particle Sizers (SMPSs). Non-volatile particle mass was estimated from particle light absorption techniques using an assumed mass absorption coefficient, while particle chemical speciation was measured by an Soot Particle Aerosol Mass Spectrometer (SP-AMS). A detailed list of instruments is given on the project website [1]. Overall, the results are consistent with expectations based on ICAO Emissions Databank certification data for the LEAP-1B with a stark reduction in non-volatile particle number and mass observed for the higher thrust conditions when the combustor was staged. The production of volatile particles under these conditions as well as experimental considerations related to background subtraction methods will be discussed.

Benjamin A. Nault↗

Prototype tests of the electromagnetic particle injector-2 for fast time response disruption mitigation in tokamaks

Predicting and controlling disruptions is an important and urgent issue for ITER. Some disruptions with a short warning time may be unavoidable. For these cases, a fast time response disruption mitigation method is essential. Experimental tests on a prototype system of a novel, rapid time-response disruption mitigation system being developed for tokamak-based reactors and as a backup option for ITER, referred to as the electromagnetic particle injector (EPI), have been able to verify the primary advantages of the concept. These are its ability to meet short warning time scales of <10 ms while attaining the projected high velocities for deep radiative payload penetration in reactor-scale plasmas. The EPI relies on an electromagnetic propulsion system. A metallic sabot is accelerated electromagnetically to the required velocities (>1 km s -1 ) within 2 ms, at which point it releases a radiative payload consisting of a shell pellet or well-defined microspheres. Initial experimental tests from the prototype system show attainment of over 600 m s -1 in about 1 ms. Finally, essential aspects of payload separation from the sabot and sabot capture have also been demonstrated at 200 m s -1 , and the method can be extended to over 2 km s -1 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-dependent density-functional-theory calculations of the nonlocal electron stopping range for inertial confinement fusion applications

Nonlocal electron transport is important for understanding laser-target coupling for laser-direct-drive (LDD) inertial confinement fusion (ICF) simulations. Current models for the nonlocal electron mean free path in radiation-hydrodynamic codes are based on plasma-physics models developed decades ago; improvements are needed to accurately predict the electron conduction in LDD simulations of ICF target implosions. Here we utilized time-dependent density functional theory (TD-DFT) to calculate the electron stopping power (SP) in the so-called conduction-zone plasmas of polystyrene in a wide range of densities and temperatures relevant to LDD. Compared with the modified Lee-More model, the TD-DFT calculations indicated a lower SP and a higher stopping range for nonlocal electrons. We fit these electron SP calculations to obtain a global analytical model for the electron stopping range as a function of plasma conditions and the nonlocal electron kinetic energy. This model was implemented in the one-dimensional radiation-hydrodynamic code LILAC to perform simulations of LDD ICF implosions, which are further compared with simulations by the standard modified Lee-More model. In conclusion, results from these integrated simulations are discussed in terms of the implications of this TD-DFT-based mean-free-path model to ICF simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization and Performance Characterization of the Second Generation Fermilab Constant Fraction Discriminator Readout ASIC

We present the optimization and performance characterization of the second-generation Fermilab Constant Fraction Discriminator ASIC (FCFD), designed for the readout of AC-coupled low-gain avalanche detector (LGAD) strip-sensors. The FCFD is explicitly engineered to be insensitive to signal-amplitude variations, thereby removing the need for time-walk correction that is required in other LGAD time-stamping readout ASICs. This updated version, referred to as FCFD1.1, incorporates several enhancements over the first iteration to address key challenges in AC-coupled LGAD front-end design. We outline the primary readout-ASIC design considerations for these applications, describe the methodology used to evaluate critical sensor and system parameters, and summarize the additionally implemented features. Performance measurements using injected charge signals and minimum-ionizing particles in test-beams demonstrate a time resolution of approximately 40 ps and a position resolution of roughly \SI{15}{\micro\meter} when tested with beam particles uniformly over the active area of the sensor.

Apresyan, Artur [Fermilab] (ORCID:0000000261860130↗

Fission product distribution in irradiated safety-tested and as-irradiated AGR-2 TRISO particles

In this work, two tristructural isotropic (TRISO)-coated nuclear fuel particles were examined by electron probe microanalysis (EPMA) as part of the Advanced Gas Reactor program. The compacts’ average irradiation temperatures ranged from approximately 1260 to 1290 °C. One particle was examined in the as-irradiated condition, while the other was subject to 1600 °C post-irradiation safety testing. This study was undertaken to test a newly-developed EPMA technique to determine fission product masses in TRISO particles on a layer-by-layer basis, and to compare fission product distributions between an as-irradiated and safety-tested particle. Fission product concentration profiles were collected along two radii in each particle, with measured concentrations used to compute the fission product mass in each TRISO particle layer. These measured masses were then compared to those predicted from ORIGEN modeling calculations. Data collected from these measurements show that for these two particles, masses determined via EPMA were within ± 20% of the calculated masses for the rare-earth elements, Mo, Zr, Cs, I, and Pd. Elements that tend to be less homogeneously distributed include Sr, Te, Eu, Ag, and possibly Ba. Measured Ag masses differed by more than 40% from the calculated mass. Lanthanides other than Eu remain primarily within the fuel kernel in the as-irradiated particle but in the safety-tested particle these element masses were divided approximately equally between the kernel and kernel periphery. In both particles, the majority of Sr and Eu accumulated in the carbon-rich kernel periphery, although in the safety-tested particle, Sr and Eu accumulated farther from the fuel kernel than occurred with irradiation alone. A greater mass fraction of mobile elements, such as Cs and I accumulated in the buffer and IPyC in the safety-tested particle as compared to the as-irradiated particle. When fully developed and tested, this mass balance approach to TRISO particle analysis has the potential to provide insight into fuel behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test-Aerosol Generator For Calibrating Particle Counters

Apparatus generates clean, stable aerosol stream for use in testing and calibrating laser-based aerosol-particle counter. Size and concentration of aerosol particles controlled to ensure accurate calibration. Cheap, widely available medical nebulizers used to generate aerosols.

Mogan, Paul A.↗

Johns Hopkins University Stereoscopic Particle Image Velocimetry (SPIV) Test Results

Professor J. Katz at the Johns Hopkins University conducted an experimental investigation of the effect of varying the clearance over the tip of a compressor rotor in an embedded stage through a NASA funded award. The activity provided very detailed stereo Particle Image Velocimetry (PIV) measurements of the tip flow field in their optically index-matched facility. The researchers were able to measure and visualize the unsteady velocity and pressure field in the tip gap area for the first time from which they have published more than 10 Journal papers. The dataset has been used widely within NASA for internal program development. The compressor geometry is part of the NASA Low-Speed Axial Compressor (LSAC) compressor stage geometry which is publicly available. All the casing treatment geometries were published by the researchers at JHU. The PIV data has also been published in several ASME papers and presented at recent TurboExpo Conferences. Many research groups at universities and US industry would like access to this data; therefore, we would like to prepare the data package and release it to public. The data package will be announced on data.nasa.gov.

Compressor↗