Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL CONVECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Internal gravity waves in massive stars: II. Frequency analysis across stellar mass

Stars that are over 1.6 solar masses are generally known to possess convective cores and radiative envelopes, which allows for the propagation of outwardly travelling internal gravity waves (IGWs). Here, we study the generation and propagation of IGWs in such stars using two-dimensional, fully non-linear hydrodynamical simulations with realistic stellar reference states from the one-dimensional stellar evolution code, Modules for Stellar Astrophysics. Compared to previous similar works, this study utilises radius-dependent thermal diffusivity profiles for five different stellar masses at the middle of the main sequence: 3 M ⊙ , 5 M ⊙ , 7 M ⊙ , 10 M ⊙ , and 13 M ⊙ . From the simulations, we find that the surface perturbations are larger for higher masses, but no noticeable trends are observed for the frequency slopes with different stellar masses. The slopes are also similar to the results from previous works. We compared our simulation results with stellar photometric data from a recent survey and we found that for frequency intervals above 8 μHz, there is a good agreement between the temperature frequency slopes from the simulations and the surface brightness variations of these observed stars. This indicates that the brightness variations are caused by core-generated IGWs.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the cooldown of cryocooler conduction-cooled devices

Cryocooler conduction cooled devices can experience significant cooldown time due to lower available cooling capacity compares to convection cooled devices. Therefore, the cooldown time is an important design parameter for conduction cooled devices. This article introduces a framework developed in Python for calculating the cooldown profiles and cooldown time of cryocooler conduction-cooled devices such as superconducting magnets and accelerator cavities. The cooldown time estimation problem is essentially a system of ordinary first-order differential equations comprising the material properties (temperature dependent thermal conductivity and specific heat capacity) of the components intertwined with the prevailing heat transfer channels (conduction, radiation, and heat flow across pressed contacts) and the cryocooler capacity. The formulation of this ODE system is first presented. This ODE system is then solved using the in-built Python library odeint. A case study is presented comprising a small cryocooler conduction-cooled copper stabilized niobium-titanium magnet. The case study is supplemented with the Python script enabling the reader to simply tweak the device design parameters and optimize the design from the point of view of slow/fast cooldown.

43 PARTICLE ACCELERATORS↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Quantitative assessment of eddy viscosity rans models for turbulent mixed convection in a differentially heated plane channel

Turbulent mixed convection between two vertical, infinite parallel plates at different temperatures is studied using various two-equation turbulence models. The numerical simulations are performed at a turbulent Reynolds number of Re τ = 150 and a Grashof number of Gr = 9.6 × 10 5 . Comparisons are made against the highly trusted DNS results. Consistent with the DNS approach, the current simulations are performed using constant properties and the Boussinesq approximation to predict the influence of buoyancy. Previous studies have provided assessments of two-equation turbulence models for various scenarios, but often rely on a qualitative “eye” test in order to determine the most appropriate model to predict a given flow. This study aims to provide a new form of quantitative assessment that accounts for both the physics captured by the turbulence model as well as the magnitude of the system response quantities (SRQ) using a modified symmetric mean absolute percent error (SMAPE) method. This method is designed to be approachable to researchers at any level and can be applied to system response quantities from multiple research fields. Uncertainty quantification is also performed to determine the discretization error for each turbulence model. Recommendations are made as to which turbulence models best capture the physics – hydrodynamically and thermally – using both local and global validation metrics. Lastly, a sensitivity analysis is performed on the damping functions used in the most accurate models. This underpins the potential of model developments and adjustments most worth pursuing for buoyant flows. Finally, this framework provides a more physics-based comparative analysis of the selected turbulence models.

42 ENGINEERING↗

Passive Microwave Radiometry and Active Radar Sounding as Complementary Tools for Geophysical Investigations of Icy Ocean Worlds

Juno Microwave Radiometer (MWR) observations of Europa and Ganymede offer critical insights into the icy shells of these moons ahead of NASA's Europa Clipper and ESA's JUpiter ICy moons Explorer (JUICE) missions. Both missions are equipped with active radar sounders designed to address key unknowns such as ice shell thickness, thermal state, and composition. In this study, we explore how passive microwave radiometry and active radar sounding can constrain ice shell properties, focusing on Europa. Using modeled microwave brightness temperature observations at 0.6 and 1.2 GHz alongside simulated radar attenuation rate observations, we show that each instrument can independently produce robust ice shell thickness constraints under idealized conditions. We then relax these assumptions, quantifying how uncertainties from non-ideal properties—including convective layers, freezing-point depression, and chloride-doped ice—affect thickness estimates. Finally, we demonstrate how combining observations from these complementary techniques breaks degeneracies between ice shell properties, enabling more robust constraints than either method alone. This approach will maximize the science return of Europa Clipper and JUICE, advancing our understanding of the thermophysical structure and habitability of icy ocean worlds.

58 GEOSCIENCES↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗

Cost-Performance Trade-off in thermoelectric air conditioning system with graded and constant material properties

Thermoelectric (TE) air cooling is a solid-state technology that has the potential to replace conventional vapor compression-based air conditioning. In this paper, we present a detailed system-level modeling for thermoelectric air conditioning system with position-dependent (graded) and constant material properties. Strategies for design optimization of the system are provided in terms of cost-performance trade-off. Realistic convection heat transfer at both sides of the system are taken into account in our modeling. Here, the effects of convection heat transfer coefficients, air flowrate, and thermoelectric material properties are investigated with varying key parameters such as TE leg thickness, module fill factor, and input current. Both constant material properties and graded properties are considered for the TE materials, and they are compared in terms of the degree of cooling, coefficient of performance (COP), and power consumption. For graded materials, we employ one-dimensional finite element methods to solve the coupled electrical and thermal current equations with arbitrary profile of material properties varying with position along the TE legs. We find that graded materials can enhance the degree of cooling, but only at the expense of COP, compared to the case of constant property materials. With constant material properties of ZT = 1 and relatively low electric current, the power consumption of TE coolers can be lower than those of conventional air conditioners at an equivalent cooling capacity. Considering additional advantages such as demand-flexible operation, low noise, and high scalability, thermoelectric cooling could be a competitive technology for future air conditioning applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Convective Vortices and Dust Devils Detected and Characterized by Mars 2020

Abstract We characterize vortex and dust devils (DDs) at Jezero from pressure and winds obtained with the Mars Environmental Dynamics Analyzer (MEDA) instrument on Mars 2020 over 415 Martian days (sols) ( Ls = 6°–213°). Vortices are abundant (4.9 per sol with pressure drops >0.5 Pa correcting from gaps in coverage) and they peak at noon. At least one in every five vortices carries dust, and 75% of all vortices with Δ p > 2.0 Pa are dusty. Seasonal variability was small but DDs were abundant during a dust storm ( Ls = 152°–156°). Vortices are more frequent and intense over terrains with lower thermal inertia favoring high daytime surface‐to‐air temperature gradients. We fit measurements of winds and pressure during DD encounters to models of vortices. We obtain vortex diameters that range from 5 to 135 m with a mean of 20 m, and from the frequency of close encounters we estimate a DD activity of 2.0–3.0 DDs km −2 sol −1 . A comparison of MEDA observations with a Large Eddy Simulation of Jezero at Ls = 45° produces a similar result. Three 100‐m size DDs passed within 30 m of the rover from what we estimate that the activity of DDs with diameters >100 m is 0.1 DDs km −2 sol −1 , implying that dust lifting is dominated by the largest vortices in Jezero. At least one vortex had a central pressure drop of 9.0 Pa and internal winds of 25 ms −1 . The MEDA wind sensors were partially damaged during two DD encounters whose characteristics we elaborate in detail.

Hueso, R.↗

Electromagnetic turbulence simulation of tokamak edge plasma dynamics and divertor heat load during thermal quench

Abstract The edge plasma turbulence and transport dynamics, as well as the divertor power loads during the thermal-quench phase of tokamak disruptions, are numerically investigated with BOUT++’s flux-driven six-field electromagnetic turbulence model. Here, transient yet intense particle and energy sources are applied at the pedestal top to mimic the plasma power drive at the edge induced by a core thermal collapse, which flattens the core temperature profile. Interesting features, such as surging of divertor heat load (up to 50 times) and broadening of heat-flux width (up to four times) on the outer-divertor target plate, are observed in the simulation, in qualitative agreement with experimental observations. The dramatic changes in divertor heat load and width are due to the enhanced plasma turbulence activities inside the separatrix. Two cross-field transport mechanisms, namely, the E × B turbulent convection and the stochastic parallel advection/conduction, are identified to play important roles in this process. First, an elevated edge pressure gradient drives instabilities and subsequent turbulence in the entire pedestal region. The enhanced turbulence not only transports particles and energy radially across the separatrix via the E × B convection, which causes the initial divertor heat-load burst, but it also induces amplified magnetic fluctuation B ˜ . Once themagnetic fluctuation is large enough to break the magnetic flux surface, magnetic flutter effect provides an additional radial transport channel. In the late stage of our simulation, | B ˜ r / B 0 | reaches to 10 −4 level that completely breaks magnetic flux surfaces such that stochastic field lines are directly connecting pedestal top plasma to the divertor target plates or first wall, further contributing to the divertor heat-flux width broadening.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal energy storage system

A thermal energy storage (TES) component includes a shell having first and second ports, and at least a first set of thermally conductive sealed containers that contain a TES media for storing thermal energy. A first set of sealed tubes containing a first TES media are in a first section of the shell, and a second set of sealed tubes containing a different TES media are in a second section of the shell. Electric heating elements are immersed in at least some of the tubes, and may extend only from one end of the tube. In some embodiments more than one heating element is immersed in the TES media and positioned to enhance convective flow. In some embodiments electric heating elements are disposed externally on the sealed tubes. Some tubes are tapered or frustoconical, with heating elements provided in a larger-diameter portion of the tubes.

Wirz, Richard E.↗

Numerical investigation of the AP1000 response following loss-of-coolant accident using PCTRAN and CFD to support R&D of SMRs

Small Modular Reactors (SMRs) present a promising solution for the future of sustainable energy, offering advantages such as reduced waste generation, advanced passive safety features, and potential cost efficiencies. Ongoing research focuses on the design and development of SMRs, addressing challenges through numerical simulations and experimental test data. Given that many next-generation reactors are first-of-a-kind (FOK), current operational reactors serve as valuable benchmarks for understanding various thermal-hydraulic phenomena during postulated design basis accidents (DBAs), including loss-of-coolant accidents (LOCA), main steam line breaks (MSLB), and steam generator tube ruptures (SGTR). This study employs the AP1000 model Personal Computer Transient Analyzer (PCTRAN) to simulate reactor responses to small-break LOCA scenarios, specifically analyzing break sizes of 2 and 10 inches. Additionally, ANSYS FLUENT software is utilized to assess containment responses to large-break LOCAs, focusing on the quantification of decay heat removal via natural convection. Verification of the PCTRAN results is achieved using Westinghouse data, with CFD results corroborating the findings. The outcomes demonstrate strong agreement with Westinghouse data, confirming the accuracy of the simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Response of East Asian Precipitation in June 2020 to Local and Remote Aerosol Emission Reductions during COVID-19

Here, in this study, the fast response of East Asian summer precipitation to COVID-19–induced aerosol emission reductions is examined using the Community Earth System Model, version 2.2 (CESM2.2). The emission reductions decreased aerosol optical depth and cloud cover over northern China in June 2020. The troposphere became warmer, strengthening the land–sea thermal contrast and anomalous southerly winds. The subtropical westerly jet accelerated and shifted southward, favoring low-level convergence, upward air motions, and subsequent condensational heating over the Yangtze River basin (YRB). The feedback of condensational heating in return strengthened the convergence and ascent. The western North Pacific subtropical high was intensified, which further enhanced the moisture advection and convergence over the YRB. Both the enhanced moisture convergence and ascent increased precipitation over the YRB during June 2020. Furthermore, local and remote emission reductions show different impacts on convection and moisture transport over the YRB. The emission reductions over China caused stronger convective precipitation (1.15 vs 0.63 mm day −1 ) but weaker larger-scale precipitation (1.17 vs 2.24 mm day −1 ) than the emission reductions outside China. In addition to the emission reductions, the sea surface temperature (SST) anomalies in 2020 also play an important role in increasing precipitation over the YRB, contributing about 42.8%. The relative contribution of SST anomalies also increases under the COVID-19–induced emission scenario.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity of Thermal Predictions to Uncertain Surface Tension Data in Laser Additive Manufacturing

To understand the process-microstructure relationships in additive manufacturing (AM), it is necessary to predict the solidification characteristics in the melt pool. This study investigates the influence of Marangoni driven fluid flow on the predicted melt pool geometry and solidification conditions using a continuum finite volume model. A calibrated laser absorptivity was determined by comparing the model predictions (neglecting fluid flow) against melt pool dimensions obtained from single laser melt experiments on a nickel super alloy 625 (IN625) plate. Using this calibrated efficiency, predicted melt pool geometries agree well with experiments across a range of process conditions. When fluid mechanics is considered, a surface tension gradient recommended for IN625 tends to overpredict the influence of convective heat transfer, but the use of an intermediate value reported from experimental measurements of a similar nickel super alloy produces excellent experimental agreement. Despite its significant effect on the melt pool geometry predictions, fluid flow was found to have a small effect on the predicted solidification conditions compared to processing conditions. We find that this result suggests that under certain circumstances, a model only considering conductive heat transfer is sufficient for approximating process-microstructure relationships in laser AM. Extending the model to multiple laser passes further showed that fluid flow also has a small effect on the solidification conditions compared to the transient variations in the process. Furthermore, limitations of the current model and areas of improvement, including uncertainties associated with the phenomenological model inputs are discussed.

36 MATERIALS SCIENCE↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of neutron noise in a micro-scale, natural circulation molten salt fission battery system

The Molten Salt Reactor (MSR) concept is a rapidly evolving Generation IV design that has recently attracted favorable attention due to the potential for reducing waste generation, realizing passive safety features, and seizing on the opportunity for cost effective economics. A specific novel micro-MSR, natural circulation, battery design concept involves placing all primary components within a single reactor vessel containment without the need of primary forced pumping. This small modular, integral design presents potential cost savings while producing safety, reliable, and transportable carbon-free power for decades. This investigation evaluates the neutron noise induced by density and flow fluctuations in a natural circulation MSR battery concept being developed at the University of Idaho. This study finds numerical solutions to the one-dimensional, one-group, coupled diffusion equations for a bare, homogeneous core, and evaluates neutron flux and delayed neutron precursor concentration noise due to core flow and fuel salt density perturbation sources. Noise analysis shows both point kinetic and space-dependent behavior is present despite the small size, low-flow, closely-coupled nature of the natural circulation MSR concept. Analysis shows that the low flow of the convective system results in noise behavior typically representative of a larger forced-circulation MSR system. Finally, noise techniques may also be useful in MSR core diagnostics as a non-invasive, low-cost radiological option to traditional monitoring schemes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward full simulations for a liquid metal blanket: part 2. Computations of MHD flows with volumetric heating for a PbLi blanket prototype at Ha ~10 4 and Gr ~10 12

On the pathway toward full simulations for a liquid metal (LM) blanket, this part 2 extends a previous study of purely magnetohydrodynamic (MHD) flows in a DCLL blanket in reference Chen et al (2020 Nucl. Fusion 60 076003) to more general conditions when the MHD flow is coupled with heat transfer. The simulated prototypic blanket module includes all components of a real LM blanket system, such as supply ducts, inlet and outlet manifolds, multiple poloidal ducts and a U-turn zone. Volumetric heating generated by fusion neutrons is added to simulate thermal effects in the flowing lead–lithium (PbLi) breeder. The MHD flow equations and the energy equation are solved with a DNS-type finite-volume code ‘MHD-UCAS’ on a very fine mesh of 470 × 10 6 cells. The applied magnetic field is 5 T (Hartmann number Ha ~ 10 4 ), the PbLi velocity in the poloidal ducts is 10 cm s –1 (Reynolds number Re ~10 5 ), whereas the maximum volumetric heating is 30 MW m –3 (Grashof number Gr ~ 10 12 ). Four cases have been simulated, including forced- and mixed-convection flows, and either an electrically conducting or insulating blanket structure. Various comparisons are made between the four computed cases and also against the purely MHD flows computed earlier in reference Chen et al (2020 Nucl. Fusion 60 076003) with regards to the (1) MHD pressure drop, (2) flow balancing, (3) temperature field, (4) flows in particular blanket components, and (5) 3D and turbulent flow effects. The strongest buoyancy effects were found in the poloidal ducts. In the electrically non-conducting blanket, the buoyancy forces lead to significant modifications of the flow structure, such as formation of reverse flows, whereas their effect on the MHD pressure drop is relatively small. In the electrically conducting blanket case, the buoyancy effects on the flow and MHD pressure drop are almost negligible.

Physics↗