Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL MASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Re-Os dating of 3AB iron meteorites

Recently, Creaser et al., and Volkening and Heumann, have demonstrated the efficient production of large (approximately 10 exp -11 A) ion beams by negative thermal ionization mass spectrometry (NTIMS) using standard laboratory solutions of Os compounds. Horan et al., have applied NTIMS to a group of 7 IIA iron meteorites and obtained a Re-Os closure age of 4596 +/- 152 million years. The initial Os-187/Os-186 ratio was 0.8007 plus or minus 0.0029. In addition they analyzed 3 IIIA meteorite samples which indicated an age of 4554 +/- 180 million years and Os initial of 0.8120 +/- 0.0075 which does not overlap with the initial for the IIA irons. We have been independently pursuing a similar program with the direct aim of determining possible variations in the initial (Os-187)/(Os-186) ratio or Re-Os closure age of different classes of iron meteorite. We have applied NTIMS to Os extracted from the most common group of iron meteorites the IIIAB. These meteorites are believed to be of magmatic origin, formed by fractional crystallization of molten cores of asteroidal bodies. The present results point to a significantly lower initial (Os-187)/(Os-186) ratio of 0.7731 plus or minus 0.0050 than previously determined.

Esat, Tezer M.↗

Osmium isotopes in Ivory Coast tektites: Confirmation of a meteoritic component and rhenium depletion

The sensitive negative thermal ionization mass spectrometry method was used for the measurement of concentrations and isotopic ratios of osmium and rhenium in four Ivory Coast tektites. These tektites have crustal major and trace element composition, as well as large negative epsilon(sub Nd)(-20) and positive epsilon(sub Sr)(+260 to +300) which are characteristic for old continental crust. Os concentrations ranging from 0.09 to 0.30 ppb were found, clearly much higher than average crustal values, Os-187/Os-186 ratios of about 1.2-1.7, and low Re-187/Os-186 ratios. These results show unambiguously the existence of a meteoritic component (on the order of 0.06%) in the Ivory Coast tektites. Low Re abundances are the result of fractionation of Re during the impact.

Koeberl, Christian↗

Rhenium-osmium isotope systematics of ordinary chondrites and iron meteorites

Using negative thermal ionization mass spectrometry, Re and Os abundances were determined by isotope dilution and Os-187/Os-186 measured in 11 ordinary chondrites, and also in 1 IIB and 3 IIIB irons. In addition, Os-186/Os-188 and Os-189/Os-188 ratios were precisely determined for 3 unspiked ordinary chondrites as a means of constraining the intensity of any neutron irradiation these meteorites may have experienced.

Walker, R. J.↗

Isotopic, Chemical and Mineralogical Investigations of Extraterrestrial Materials

The principal aim of our work was to improve our understanding of the earliest evolutionary period of our solar system (i.e. the first tens of millions of years). We have studied its chronology by using short and long term chronometers (based on extinct and long lived radioactive nuclei), explored the bearing of short lived nuclei on planetary heating and differentiation, and the addition of 'exotic' nuclei to solar system matter to help constrain models of nucleosynthesis. Our basic tool is high precision Thermal Ionization Mass Spectrometry (TIMS). Over the years we have developed clean chemical separation procedures for many elements. The chemical elements most relevant to our investigations are Cr, Ni, Rb, Sr, Sm, Nd, Pb, and U, for which highly efficient measurement techniques by TIMS have been developed and have been in use in our laboratory for many years. We have explored the Mn-53 Cr-53 system (T (Mn-53) = 3.7 Ma) and have found it to be a powerful tool to obtain relative ages of meteorite formation and, more general, of early solar system processes with a time resolution of approx. 1 Ma. By measuring the Mn-Cr system in many meteorite types (chondrites, basaltic achondrites, angrites, pallasites, etc.) we have found that this condition is indeed met for most meteorite families.

Lugmair, Guenter W.↗

International Test Program for Synergistic Atomic Oxygen and VUV Exposure of Spacecraft Materials

Spacecraft in low Earth orbit (LEO) are subject to degradation in thermal and optical performance of components and materials through interaction with atomic oxygen and vacuum ultraviolet radiation which are predominant in LEO. Due to the importance of LEO durability and performance to manufacturers and users, an international test program for assessing the durability of spacecraft materials and components was initiated. Initial tests consisted of exposure of samples representing a variety of thermal control paints and multilayer insulation materials that have been used in space. Materials donated from various international sources were tested alongside a material whose performance is well known such as Teflon FEP or Kapton H for multilayer insulation, or Z-93-P for white thermal control paints. The optical, thermal or mass loss data generated during the test was then provided to the participating material supplier. Data was not published unless the participant donating the material consented to publication. This paper presents a description of the types of tests and facilities that have been used for the test program as well as some examples of data that have been generated. The test program is intended to give spacecraft builders and users a better understanding of degradation processes and effects to enable improved prediction of spacecraft performance.

Rutledge, Sharon↗

Pressure Control System Design for a Closed Crop Growth Chamber

The Controlled Ecological Life Support System (CELSS) is an area of active research at NASA. CELSS is a plant-based bioregenerative life support system for long term manned space flights where resupply is costly or impractical. The plants in a CELSS will function to convert the carbon dioxide (exhaled by the crew) into oxygen, purify non-potable water into potable quality water, and provide food for the crew. Prior to implementing a CELSS life support system, one must have knowledge on growing plants in a closed chamber under low gravity. This information will come from research to be conducted on the CELSS Test Facility that will operate on the Space Station Freedom. Currently a ground-based CELSS Test Facility is being built at NASA Ames Research Center. It is called the EDU (Engineering Development Unit). This system will allow researchers to identify issues that may cause difficulties in the development of the CELSS Test Facility and aid in the development of new needed technologies. The EDU consists of a 1 m2 crop growth chamber that is surrounded by a containment enclosure. The containment enclosure isolates the system so there is very little mass and thermal exchange with the ambient. The leakage rate is on the order of 1 % of the enclosure's volume per day (with 0.2S psi pressure difference). The thermal leakage is less than 0.5% of the electrical power supplied to the system per degree Celsius difference from the surrounding. The pressure in the containment enclosure is regulated at 62.5 Pa below the ambient by an active controller. The goal is to maintain this set point for a variety of conditions, such as a range of operating temperatures, heat load variations that occur when the lights are turned on and off, and fluctuations in ambient pressure. In addition certain transition tracking performance is required. This paper illustrates the application of some advanced systems control methods to the task of synthesizing the EDU's pressure control system.

Tsai, K.↗

More on Ru Endemic Isotope Anomalies in Meteorites

We reported last year on endemic isotope anomalies for Ru in iron meteorites, pallasites, ordinary chondrites, and on a whole-rock sample of Allende. We have extended the Ru measurements to more meteorites, to refractory Ca-Al-rich inclusions (CAI) from Allende, and to a whole rock sample of Murchison (CM2). In a companion abstract we report on new measurements for the Mo isotopes, in some of the same samples. There has been a renewed interest in searching for isotope anomalies in this nuclide region, as Ru and Mo include many isotopes from r-, s-, and p-process nucleosynhesis. Furthermore, the Ru and Mo p-process isotopes show atypically high abundances, which have been hard to explain through the standard nucleosynthetic processes. Effects are possible in Ru-98 and Ru-99 from Tc-98 (with a poorly known t(sub 1/2)=4.2 to 10Ma) and from Tc-99 (t(sub 1/2)=0.21Ma). Natural Tc is now extinct on Earth due to the short half-lives, but may have been present in the early solar system. Both radiogenic and general isotope anomalies are important in understanding the processes for the formation of the early solar system. The current emphasis on Ru and Mo is also the result of the development of Negative-ion Thermal Ionization Mass Spectrometry and of Multiple-Collector, Inductively-Coupled-Mass-Spectrometry. We have also developed specific chemical siparation techniques for Ru, which eliminated mass interference effects.

Papanastassiou, D. A.↗

LISA Propulsion Module Separation Study

The Laser Interferometer Space Antenna (LISA) mission is a space-borne gravitational wave detector consisting of three spacecraft in heliocentric orbit. Each spacecraft is delivered to it operational orbit by a propulsion module. Because of the strict thermal and mass balancing requirements of LISA, the baseline mission concept requires that the propulsion module separate from the sciencecraft after delivery. The only propulsion system currently baselined for the sciencecraft are micronewton level thrusters, such as FEEP or colloid thrusters, that are used to balance the 30-40 microN of solar radiation pressure and provide the drag-free and attitude control of the spacecraft. Due to these thrusters limited authority, the separation of the propulsion module from the sciencecraft must be well controlled to not induce a large tip-off rotation of the sciencecraft. We present here the results of a design study of the propulsion module separation system that is shown to safely deliver the LISA sciencecraft to its final operational orbit.

Merkowitz, Stephen↗

Progress on the Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic field (B(sub p) and B(sub t), respectively). An object with B(sub p)/B(sub t), much much more than 1 is called a Field Reverse Configuration (FRC); if B(sub p) approximately equal to B(sub t), it is called a Spheromak. The thruster operates by repetitively producing plasmoids that are accelerated and ejected at high velocity. As this process is inductive, there are no electrodes. Also, the magnetic structure of the plasmoid should suppress thermal and mass losses to the wall, and improve detachment of the plasma exhaust from the thruster. This concept should be capable of producing an Isp in the range of 5,000 - 10,000 s with thrust densities of order 10(exp 5) N per square meters. The current experiment is designed to produce jet powers in the range of 5-10 kW, although the concept should be scalable into the MW range. In PTX, the plasmoid is formed inside of a single turn conical theta-pinch coil (17.58 cone angle). The coil is driven by a 640 nF, 35 kV capacitor bank, which rings at a frequency of 500 kHz. Previous experiments on PTX were conducted with a static-fill of propellant gas (6% H2 in He), and demonstrated reliable ionization over a pressure range of 40 - 200 mTorr. We are now adding a fast gas-puff valve to load the propellant, and a ringing pre-ionization circuit (f = 5 Mhz) to better control the plasmoid formation. An alternate coil (8.58 cone angle) will also be used, so as to investigate the effect of coil shape on performance. In addition, a variety of propellants will be used, including hydrogen, nitrogen, and argon. The plasmoid mass and velocity will be measured with a variety of diagnostics, including external B-dot probes and flux loops, a high-speed framing camera, and a HeNe laser interferometer. Internal B-dot probes and a quadruple Langmuir probe will provide additional measurements of the plasmoid shape and structure, as well as density, and will be described in a companion paper. The experimental results will be compared to calculations made using a 0-D coil-gun model and also a 2-D time dependent MHD code.

Martin, Adam↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

The Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. If B(sup p)/B(sub t) is much greater than 1, it is an FRC; if B(sub p) approximately equals B(sub t), it is a Spheromak. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust. This concept should be capable of producing an Isp in the range of 5,000 - 10,OOO seconds, with high thrust density. PTX is a device designed to study this concept. The plasmoid is formed inside of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank. Experiments conducted with a static-fill of propellant gas (6% H2 in He) demonstrated reliable ionization over a pressure range of 40 - 200 mTorr. A fast gas-puff valve to inject propellant has since been added, and a ringing pre-ionization circuit to independently control ionization has been tested. Hydrogen, deuterium, argon, and an N2/H2 mixture have been tried as propellants. Measurements of the plasmoid shape, mass, and velocity, using a variety of diagnostics will be presented,

Martin, Adam↗

The Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. If B(sub p/B(sub t) much greater than 1 it is an FRC; if B(sub p) approximately equal to B(sub t), it is a Spheromak. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust, This concept should be capable of producing an Isp in the range of 5,000 - l0,000 seconds, with high thrust density. PTX is a device designed to study this concept. The plasmoid is formed inside of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank. Experiments conducted with a static-fill of propellant gas (6% H2 in He) demonstrated liable ionization over a pressure range of 40 - 200 mTorr. A fast gas-puff valve to inject propellant has since been added, and a ringing preionization circuit to independently control ionization has been tested, hydrogen, deuterium, argon, and an N2 / H2 mixture have been tried as propellants. Measurements of the plasmoid shape, mass, and velocity, using a variety of diagnostics will be presented.

Martin, Adam↗

High-Power Radar Sounders for the Investigation of Jupiter Icy Moons

The high power and high data rate capability made available by a Prometheus class spacecraft could significantly enhance our ability to probe the subsurface of the planets/moons and asteroid/comets. The main technology development driver for our radar is the proposed Jupiter Icy Moon Orbiter (or JIMO) mission due to its harsh radiation environment. We plan to develop a dual-band radar at 5 and 50 MHz in response to the two major science requirements identified by the JIMO Science Definition Team: studying the near subsurface (less than 2 km) at high resolution and detection of the ice/ocean interface for Europa (depth up to 30 km). The 50-MHz band is necessary to provide high spatial resolution (footprint and depth) as required by the JIMO mission science requirements as currently defined. Our preliminary assessment indicates that the 50-MHz system is not required to be as high-power as the 5-MHz system since it will be more limited by the surface clutter than the Jupiter or galactic background noise. The low frequency band (e.g. 5 MHz), which is the focus of this effort, would be necessary to mitigate the performance risks posed by the unknown subsurface structure both in terms of unknown attenuation due to volumetric scattering and also the detection of the interface through the attenuative transition region at the ice/ocean interface. Additionally, the 5-MHz band is less affected by the surface roughness that can cause loss of coherence and clutter noise. However, since the Signal-to-Noise-Ratio (SNR) of the 5-MHz radar band is reduced due to Jupiter noise when operating in the Jupiter side of the moon, it is necessary to increase the radiated power. Our challenge is to design a high-power HF radar that can hnction in Jupiter's high radiation environment, yet be able to fit into spacecraft resource constraints such as mass and thermal limits. Our effort to develop the JIMO radar sounder will rely on our team's experience with planetary radar sounder design gained during our participation in the MARSIS radar sounder implementation.

Safaeinili, A.↗

International Test Program for Synergistic Atomic Oxygen and Vacuum Ultraviolet Radiation Exposure of Spacecraft Materials

The components and materials of spacecraft in low Earth orbit can degrade in thermal and optical performance through interaction with atomic oxygen and vacuum ultraviolet (VUV) radiation, which are predominant in low Earth orbit. Because of the importance of low Earth orbit durability and performance to manufacturers and users, an international test program for assessing the durability of spacecraft materials and components was initiated. Initial tests at the NASA Glenn Research Center consisted of exposure of samples representing a variety of thermal control paints, multilayer insulation materials, and Sun sensors that have been used in space. Materials donated from various international sources were tested alongside materials whose performance is well known, such as Teflon FEP, Kapton H, or Z-93-P white paint. The optical, thermal, or mass loss data generated during the tests were then provided to the participating material suppliers. Data were not published unless the participant donating the material consented to publication. The test program is intended to give spacecraft builders and users a better understanding of degradation processes and effects so that they can improve their predictions of spacecraft performance.

Miller, Sharon K.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Carbon-Carbon Recuperators in Closed-Brayton-Cycle Nuclear Space Power Systems: A Feasibility Assessment

The feasibility of using carbon-carbon recuperators in closed-Brayton-cycle (CBC) nuclear space power conversion systems (PCS) was assessed. Recuperator performance expectations were forecast based on projected thermodynamic cycle state values for a planetary mission. Resulting thermal performance, mass and volume for a plate-fin carbon-carbon recuperator were estimated and quantitatively compared with values for a conventional offset-strip-fin metallic design. Material compatibility issues regarding carbon-carbon surfaces exposed to the working fluid in the CBC PCS were also discussed.

Barrett, Michael J.↗

Progress on the Plasmoid Thruster Experiment (PTX)

A plasmoid, also called a compact toroid, is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic field (Bp and Bt, respectively). An object with Bp/Bt much greater than 1 is called a Field Reverse Configuration (FRC); if Bp = Bt, it is called a Spheromak. The plasmoid thruster is a pulsed inductive device which operates by repetitively producing plasmoids that are accelerated and ejected at high velocity. As the process is inductive, this thruster avoids the problem of electrode erosion. Also, the magnetic structure of the plasmoid should suppress thermal and mass losses to the wall, and improve detachment of the plasma exhaust from the thruster. This concept should be capable of producing an Isp of 5,000 seconds and greater, with thrust densities of order 10(exp 5) N/sq m. The plasmoid thruster consists chiefly of a conical theta-pinch coil. Propellant is introduced onto a bias magnetic field, produced by an auxiliary coil, and is then pre-ionized, freezing in the magnetic field. The theta-pinch coil is then energized producing a field aligned anti- parallel to the bias field. The reversed field reconnects with the bias field to form the plasmoid. The magnetic pressure of the reversed field accelerates the plasmoid out of the thruster . A series of experiments have been conducted on the PTX device, which consisted of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank, which rang at a frequency of 500 kHz, and served all three functions required for formation: pre-ionization, bias field loading, and field reversal. Initial ionization was found to occur in an annular region at the exit plane of the coil, and was found to be reproducible with a variety of gases, including H2, D2, Ar, and an H2/N2 mixture (75% / 25%). A fast gas valve for injecting propellant has been tested, as well as a ringing pre-ionization circuit (operating at 5 Mhz) to better control the plasmoid formation. Velocities as high as 20 km/s have been measured for a plasmoid propagating into a static back-fill of neutral gas. Magnetic field and density measurements indicate that the plasmoid retains its structure well into the down-stream exhaust region, and that it is capable of pushing a dense cloud of neutral gas in front of it. Further experiments will focus on the effects of coil geometry and bias-field strength on the performance of the device. A high-power solid-state switching system is being developed in order to replace the spark-gap switch.

Martin, Adam↗

Effects of Lewis Number on Temperatures of Spherical Diffusion Flames

Spherical diffusion flames supported on a porous sphere were studied numerically and experimentally. Experiments were performed in 2.2 s and 5.2 s microgravity facilities. Numerical results were obtained from a Chemkin-based program. The program simulates flow from a porous sphere into a quiescent environment, yields both steady-state and transient results, and accounts for optically thick gas-phase radiation. The low flow velocities and long residence times in these diffusion flames lead to enhanced radiative and diffusive effects. Despite similar adiabatic flame temperatures, the measured and predicted temperatures varied by as much as 700 K. The temperature reduction correlates with flame size but characteristic flow times and, importantly, Lewis number also influence temperature. The numerical results show that the ambient gas Lewis number would have a strong effect on flame temperature if the flames were steady and nonradiating. For example, a 10% decrease in Lewis number would increase the steady-state flame temperature by 200 K. However, for these transient, radiating flames the effect of Lewis number is small. Transient predictions of flame sizes are larger than those observed in microgravity experiments. Close agreement could not be obtained without either increasing the model s thermal and mass diffusion properties by 30% or reducing mass flow rate by 25%.

Santa, K. J.↗