Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSLATIONAL MOTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

STRV-1B Cryocooler Vibration Suppression

The STRV-1B cryocooler vibration suppression experiment is a satellite flight demonstration of piezo vibration-suppression technology. A very small, tactical stirling-cooler was flown primarily as a vibration source. Two types of piezo actuators were demonstrated. Low-voltage piezo translators were used to move the entire cryocooler so that the tip of the coldfinger stood still. Also, high-voltage ceramic applique was bonded to the base of the coldfinger providing a second actuation method to compare with the translators. three eddy current transducers were used to measure the coldfinger tip motion relative to the experiment case. The eddy current signal drove two types of control systems. A digital adaptive-feed- forward control system was used to cancel the tip motion of the cryocooler in three dimensions. An analog-comb filter controller was also developed to contrast the two techniques. Motion suppression does nothing to suppress the unbalanced forces in the cryocooler, so a triaxial accelerometer measured the vibration of the satellite in response to the cryocooler. Satellite/ground test results from each of the experiment systems are shown and the systems are compared.

STRV-1B↗

Moving base simulation evaluation of translational rate command systems for STOVL aircraft in hover

Using a generalized simulation model, a moving-base simulation of a lift-fan short takeoff/vertical landing fighter aircraft has been conducted on the Vertical Motion Simulator at Ames Research Center. Objectives of the experiment were to determine the influence of system bandwidth and phase delay on flying qualities for translational rate command and vertical velocity command systems. Assessments were made for precision hover control and for landings aboard an LPH type amphibious assault ship in the presence of winds and rough seas. Results obtained define the boundaries between satisfactory and adequate flying qualities for these design features for longitudinal and lateral translational rate command and for vertical velocity command.

Franklin, James A.↗

Generalized seismic analysis

There is a constant need to be able to solve for enforced motion of structures. Spacecraft need to be qualified for acceleration inputs. Truck cargoes need to be safeguarded from road mishaps. Office buildings need to withstand earthquake shocks. Marine machinery needs to be able to withstand hull shocks. All of these kinds of enforced motions are being grouped together under the heading of seismic inputs. Attempts have been made to cope with this problem over the years and they usually have ended up with some limiting or compromise conditions. The crudest approach was to limit the problem to acceleration occurring only at a base of a structure, constrained to be rigid. The analyst would assign arbitrarily outsized masses to base points. He would then calculate the magnitude of force to apply to the base mass (or masses) in order to produce the specified acceleration. He would of necessity have to sacrifice the determination of stresses in the vicinity of the base, because of the artificial nature of the input forces. The author followed the lead of John M. Biggs by using relative coordinates for a rigid base in a 1975 paper, and again in a 1981 paper . This method of relative coordinates was extended and made operational as DMAP ALTER packets to rigid formats 9, 10, 11, and 12 under contract N60921-82-C-0128. This method was presented at the twelfth NASTRAN Colloquium. Another analyst in the field developed a method that computed the forces from enforced motion then applied them as a forcing to the remaining unknowns after the knowns were partitioned off. The method was translated into DMAP ALTER's but was never made operational. All of this activity jelled into the current effort. Much thought was invested in working out ways to unshakle the analysis of enforced motions from the limitations that persisted.

Butler, Thomas G.↗

Functional organization of primate translational vestibulo-ocular reflexes and effects of unilateral labyrinthectomy

Translational vestibulo-ocular reflexes (trVORs) are characterized by distinct spatio-temporal properties and sensitivities that are proportional to the inverse of viewing distance. Anodal (inhibitory) labyrinthine stimulation (100 microA, < 2 s) during motion decreased the high-pass filtered dynamics, as well as horizontal trVOR sensitivity and its dependence on viewing distance. Cathodal (excitatory) currents had opposite effects. Translational VORs were also affected after unilateral labyrinthectomy. Animals lost their ability to modulate trVOR sensitivity as a function of viewing distance acutely after the lesion. These deficits partially recovered over time, albeit a significant reduction in trVOR sensitivity as a function of viewing distance remained in compensated animals. During fore-aft motion, the effects of unilateral labyrinthectomy were more dramatic. Both acute and compensated animals permanently lost their ability to modulate fore-aft trVOR responses as a function of target eccentricity. These results suggest that (1) the dynamics and viewing distance-dependent properties of the trVORs are very sensitive to changes in the resting firing rate of vestibular afferents and, consequently, vestibular nuclei neurons; (2) the most irregularly firing primary otolith afferents that are most sensitive to labyrinthine electrical stimulation might contribute to reflex dynamics and sensitivity; (3) inputs from both labyrinths are necessary for the generation of the translational VORs.

Non-NASA Center↗

Rotational and translational diffusion of liquid n-hexane: EFP-based molecular dynamics analysis

Molecular Dynamics (MD) simulations based on the Effective Fragment Potential (EFP) method are utilized to provide a comprehensive assessment of diffusion in liquid n-hexane. We decompose translational diffusion into components along and orthogonal to the long axis of the molecule. Rotational diffusion is decomposed into tumbling and spinning motions about this axis. Our analysis yields four corresponding diffusion coefficients which are related to diagonal entries in the complete 6 × 6 diffusion tensor accounting for the three rotational and three translational degrees of freedom and for the potential coupling between them. However, coupling between different degrees of freedom is expected to be minimal for a natural choice of the molecular body-fixed axis, so then off-diagonal entries in the tensor are negligible. This expectation is supported by a hydrodynamic analysis of the diffusion tensor which treats the liquid surrounding the molecule being tracked as a viscous continuum. Thus, the EFP MD analysis provides a comprehensive characterization of diffusion and also reveals expected shortcomings of the hydrodynamic treatment, particularly for rotational diffusion, when applied to neat liquids.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control During Variable Radius Centrifugation Following Space Flight

Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, less than 20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. One result of this study will be to characterize the variability (gain, asymmetry) in both otolith-ocular responses and motion perception during variable radius centrifugation, and measure the time course of post-flight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

Wood, Scott J.↗

ZAG-Otolith: Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control during Variable Radius Centrifugation Following Space Flight

Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, <20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. One result of this study will be to characterize the variability (gain, asymmetry) in both otolithocular responses and motion perception during variable radius centrifugation, and measure the time course of postflight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

Wood, S. J.↗

Kinematid Parameters of Corrective Postural Responses Differ between Upper and Lower Body Perturbations

Balance control is disrupted following prolonged microgravity exposure, and to better understand this, both upper and lower body perturbations have been used to study postural control in space flight crewmembers. However, differences between several postural response indicators observed using the two techniques suggest that different sensory systems may be involved in organizing responses to these different perturbation approaches. The present study sought to compare differences in parameters of corrective postural responses between upper body perturbations (pushes to the chest) and forward translations of the support surface. Nine subjects participated in this study. Forward translations were performed using a NeuroCom EquiTest(TM) CDP system, which was synchronized with a Northern Digital OptoTrak motion tracking system (3 subjects). Chest pushes were applied using a hand-held force transducer device and were performed using a stabilometric system (6 subjects). Analysis of EMG has shown that: i) the earliest response of the leg muscles was registered significantly later during forward translation of the support surface than during chest pushes, and ii) there was a tendency for the different order of leg muscles activation during the translation tests. Analysis of the kinematic data showed a significant difference in the subject's body segments inclinations during corrective postural responses to upper and lower body perturbations. It appears that upper body perturbations likely engage the vestibular system more rapidly, while lower body perturbations likely engage somatosensory systems more rapidly. These differences must be taken into account when choosing the type of perturbation for testing postural function.

Sayenko, G.↗

A hydrodynamic model of the oscillating screen viscometer

The viscometer consists of an oscillating screen immersed in a fluid and free to rotate about an axis in its plane. The viscosity can be determined from the measured ratio of the periodic driving force to the screen motion when an adequate hydrodynamical model of the immersed oscillator is available. The screen is formed by a square mesh of thin wire whose dimensions invite comparison with asymptotic results for narrow hollow bodies translating in Stokes flow. These indicate that the closed hole structure of the grid plays an important role in determining its motion. It is shown that this role diminishes as the frequency increases. The computed results, obtained from a system of linear equations, are consistent with experimental values over the appropriate range of frequency.

Davis, A. M. J.↗

Multi-axis hand controller for the shuttle remote manipulator system

The Shuttle Remote Manipulator System, has a articulated arm of 50 ft. length with six motor-driven joints. The basic purpose is to establish physical contact with various space hardware items and maneuver these to the desired position and attitude with respect to the Orbiter, nulling out relative velocities and stabilizing the free-body system by managing residual energies. The normal operating mode is resolved-motion end-point rate control by man-in-loop command. The translational freedoms are defined so that the End Effector (EEFTR) of the arm will move in planes parallel to the principal translational planes of the Orbiter, at a rate commanded by the displacement of the Translation Hand Controller in the corresponding freedom and direction. The rotational freedoms are rate-controlled by the Rotation Hand Controller about pivot axes parallel to Orbiter roll, pitch and yaw, originating at the EEFTR reference point.

Lippay, A. L.↗

Force reflecting hand controller

A universal input device for interfacing a human operator with a slave machine such as a robot or the like includes a plurality of serially connected mechanical links extending from a base. A handgrip is connected to the mechanical links distal from the base such that a human operator may grasp the handgrip and control the position thereof relative to the base through the mechanical links. A plurality of rotary joints is arranged to connect the mechanical links together to provide at least three translational degrees of freedom and at least three rotational degrees of freedom of motion of the handgrip relative to the base. A cable and pulley assembly for each joint is connected to a corresponding motor for transmitting forces from the slave machine to the handgrip to provide kinesthetic feedback to the operator and for producing control signals that may be transmitted from the handgrip to the slave machine. The device gives excellent kinesthetic feedback, high-fidelity force/torque feedback, a kinematically simple structure, mechanically decoupled motion in all six degrees of freedom, and zero backlash. The device also has a much larger work envelope, greater stiffness and responsiveness, smaller stowage volume, and better overlap of the human operator's range of motion than previous designs.

Mcaffee, Douglas A.↗

Voice Controlled Wheelchair

Michael Condon, a quadraplegic from Pasadena, California, demonstrates the NASA-developed voice-controlled wheelchair and its manipulator, which can pick up packages, open doors, turn a TV knob, and perform a variety of other functions. A possible boon to paralyzed and other severely handicapped persons, the chair-manipulator system responds to 35 one-word voice commands, such as "go," "stop," "up," "down," "right," "left," "forward," "backward." The heart of the system is a voice-command analyzer which utilizes a minicomputer. Commands are taught I to the computer by the patient's repeating them a number of times; thereafter the analyzer recognizes commands only in the patient's particular speech pattern. The computer translates commands into electrical signals which activate appropriate motors and cause the desired motion of chair or manipulator. Based on teleoperator and robot technology for space-related programs, the voice-controlled system was developed by Jet Propulsion Laboratory under the joint sponsorship of NASA and the Veterans Administration. The wheelchair-manipulator has been tested at Rancho Los Amigos Hospital, Downey, California, and is being evaluated at the VA Prosthetics Center in New York City.

Source record↗

Long-Lived Linear-Motion Suspension For Cryogenic Instrument

Mechanism suspends optical component in cryogenic instrument in such way to allow component to translate smoothly along one axis, without vibration. Bearings located outside cooled instrument chamber for longer life. Thermal isolators separate bearings from cryogenic environment inside instrument chamber.

Packard, Douglas T.↗

Rotational and Translational Velocity and Acceleration Thresholds for the Onset of Cybersickness in Virtual Reality

This paper determined rotational and translational velocity and acceleration thresholds for the onset of cybersickness. Cybersickness causes discomfort and discourages the widespread use of virtual reality systems for both recreational and professional use. Visual motion or optic flow is known to be one of the main causes of cybersickness due to the sensory conflict it creates with the vestibular system. The aim of this experiment is to detect rotational and translational velocity and acceleration thresholds that cause the onset of cybersickness. Participants were exposed to a moving particle field in virtual reality for a few seconds per run. The field moved in different directions (longitudinal, lateral, roll, and yaw), with different velocity profiles (steady and accelerating), and different densities. Using a staircase procedure, that controlled the speed or acceleration of the field, we detected the threshold at which participant started to feel temporary symptoms of cybersickness. The optic flow was quantified for each motion type and by modifying the number of features, the same amount of optic flow was present in each scene. Having the same optic flow in each scene allows a direct comparison of the thresholds. The results show that the velocity and acceleration thresholds for rotational optic flow were significantly lower than for translational optic flow. The thresholds suggestively decreased with the decreasing particle density of the scene. Finally, it was found that all the rotational and translational thresholds strongly correlate with each other. While the mean values of the thresholds could be used as guidelines to develop virtual reality applications, the high variability between individuals implies that the individual tuning of motion controls would be more effective to reduce cybersickness while minimizing the impact on the experience of immersion.

Terenzi, Lorenzo↗

Directivity of acoustic radiation from sources

The radiation properties of acoustic monopoles and dipoles are described. The directivity of radiation from these sources in a free field and in the presence of an absorptive surface is described. The kinematic effects on source radiation due to translation and rotation are discussed. Experimental measurements of sound from an acoustic monopole in motion and the characteristics of helicopter rotor and propeller noise are reviewed. An introduction is provided to several essential concepts required by noise control engineers making measurements of noise from moving sources in the proximity of the ground.

Lansing, D. L.↗

Directivity of acoustic radiation from sources

The radiation properties of acoustic monopoles and dipoles are described, as well as the directivity of radiation from these sources in a free field and in the presence of an absorptive surface. The kinematic effects on source radiation due to translation and rotation are discussed. Experimental measurements of sound from an acoustic monopole in motion and the characteristics of helicopter rotor and propeller noise are reviewed. Several essential concepts required by noise control engineers making measurements of noise from moving sources in the proximity of the ground are introduced.

Lansing, D. L.↗

Face-Sealing Butterfly Valve

Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

Tervo, John N.↗

Self calibrating autoTRAC

The work reported here demonstrates how to automatically compute the position and attitude of a targeting reflective alignment concept (TRAC) camera relative to the robot end effector. In the robotics literature this is known as the sensor registration problem. The registration problem is important to solve if TRAC images need to be related to robot position. Previously, when TRAC operated on the end of a robot arm, the camera had to be precisely located at the correct orientation and position. If this location is in error, then the robot may not be able to grapple an object even though the TRAC sensor indicates it should. In addition, if the camera is significantly far from the alignment it is expected to be at, TRAC may give incorrect feedback for the control of the robot. A simple example is if the robot operator thinks the camera is right side up but the camera is actually upside down, the camera feedback will tell the operator to move in an incorrect direction. The automatic calibration algorithm requires the operator to translate and rotate the robot arbitrary amounts along (about) two coordinate directions. After the motion, the algorithm determines the transformation matrix from the robot end effector to the camera image plane. This report discusses the TRAC sensor registration problem.

Everett, Louis J.↗