Bubble Dynamics, Two-Phase Flow, and Boiling Heat Transfer in Microgravity

This report contains two independent sections. Part one is titled "Terrestrial and Microgravity Pool Boiling Heat Transfer and Critical heat flux phenomenon in an acoustic standing wave." Terrestrial and microgravity pool boiling heat transfer experiments were performed in the presence of a standing acoustic wave from a platinum wire resistance heater using degassed FC-72 Fluorinert liquid. The sound wave was created by driving a half wavelength resonator at a frequency of 10.15 kHz. Microgravity conditions were created using the 2.1 second drop tower on the campus of Washington State University. Burnout of the heater wire, often encountered with heat flux controlled systems, was avoided by using a constant temperature controller to regulate the heater wire temperature. The amplitude of the acoustic standing wave was increased from 28 kPa to over 70 kPa and these pressure measurements were made using a hydrophone fabricated with a small piezoelectric ceramic. Cavitation incurred during experiments at higher acoustic amplitudes contributed to the vapor bubble dynamics and heat transfer. The heater wire was positioned at three different locations within the acoustic field: the acoustic node, antinode, and halfway between these locations. Complete boiling curves are presented to show how the applied acoustic field enhanced boiling heat transfer and increased critical heat flux in microgravity and terrestrial environments. Video images provide information on the interaction between the vapor bubbles and the acoustic field. Part two is titled, "Design and qualification of a microscale heater array for use in boiling heat transfer." This part is summarized herein. Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed Analog to Digital (A/D) converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Chung, Jacob N.↗

Effects of Ambient Inert Gas Properties on Cool-Flame Combustion of Normal-Alkane Droplets in Microgravity

Cool-flame-supported quasi-steady droplet combustion was first observed during droplet combustion experiments conducted onboard the International Space Station (ISS) in the Combustion Integrated Rack (CIR) with n-alkane fuels. These cool flames, not visible to the naked eye, result from the existence of the negative-temperature-coefficient (NTC) region during the combustion n-alkane fuels when the chemical-kinetic pathways experience a transition from the low-temperature chemistry to the normal, high-temperature-controlled chemistry. In this study, we present results for the cool-flame-supported droplet burning rates and extinction diameters for n-alkane fuels (n-heptane, n-octane, n-decane, and n-dodecane) in inert-diluent-substituted ambient environments. In these ISS experiments, some of the nitrogen in the ambient gas mixture is replaced by an inert gas, namely, carbon dioxide, helium, or xenon. Different diluents were observed to exert remarkably different influences on the cool-flame combustion of fuel droplets. The results show that the cool-flame extinction diameter is drastically increased with helium dilution compared to N2, CO2 or Xe, and Xe dilution leads to longer burning with a smaller extinction diameter. Unlike hot flames, the cool-flame burning rates are controlled by the cool-flame temperature established in the NTC region by the chemical kinetics, rather than by equilibrium thermodynamics, and the thermo-physical properties of the ambient gases, which control the heat feed back to the liquid droplet. The cool-flame extinction is triggered by the instability that occurs at the low-temperature end of the NTC region, below which cool diffusion flames become statically unstable. A quasi-steady theoretical model, presented earlier, which involves a six-step reduced-chemistry mechanism, valid around the lower end of the NTC region, is shown to explain the observed experimental trends qualitatively.

microgravity↗

Space suits.

Mercury pressure suit and space suit design for project gemini, noting temperature control by ventilation distribution system

TEMPERATURE CONTROL↗

Advanced Control Surface Seal Development for Future Space Vehicles

High temperature control surface seals have been identified as a critical technology in the development of future space vehicles. These seals must withstand temperatures of up to 2600 F and protect underlying temperature-sensitive structures (such as actuators and sealing capability by remaining resilient during flight conditions. The current baseline seal, used on the Shuttle orbiters and the X-38 vehicle, consists of a Nextel 312 sheath, an internal Inconel X-750 knitted spring tube, and hand-stuffed Saffil batting. Unfortunately at high temperatures (> 1500 F), the seal resiliency significantly degrades due to yielding and creep of the spring tube element. The permanent set in the seals can result in flow passing over the seals and subsequent damage to temperature sensitive components downstream of the seals. Another shortcoming of the baseline seal is that instances have been reported on Shuttle flights where some of the hand-stuffed Saffil batting insulation has been extracted, thus potentially compromising the seal. In vehicles where the thermal protection systems are delicate (such as with Shuttle tiles), the control surface seals must also limit the amount of force applied to the opposing surfaces. Additionally, in many applications the seals are subjected to scrubbing as control surfaces are actuated. The seals must be able to withstand any damage resulting from this high temperature scrubbing and retain their heat/flow blocking abilities.

DeMange, Jeffrey J.↗

Improved thermoelectrically cooled quartz crystal microbalance

Design changes in the thermoelectrically-cooled quartz microbalance, which is used to monitor surface contamination in space simulation chambers, is described in terms of its extended temperature range, increased temperature control, mass sensitivity, and cooling power. The mass sensor uses 20 MHz quartz crystals having a sensitivity of 8.8 x 10 to the minus tenth power g/sq cm - Hz. The crystals are optically polished, metal plated, and overplated with magnesium fluoride to simulate an optical surface. The microbalance temperature circuitry is designed to readout and control surface temperature between 100 C and minus 59 C to plus or minus 0.5 C, and readout only temperature between minus 60 C and minus 199 C using auxiliary liquid nitrogen cooling. Data is included on the measurement of oil contamination of surfaces as a function of temperature in space simulation chambers.

D. McKeown↗

Thermal scale modeling.

Test models of spacecraft to investigate thermal behavior, particularly Mariner temperature control model

SPACECRAFT MODEL↗

Passive thermal-control coatings

Design engineer's handbook discusses passive temperature control techniques, selection of control surfaces, and environmental damage mechanisms.

Mookherji, T. K.↗

Mariner-Mars absorptance experiment.

Absorptivity standard instrument to investigate solar absorptance of four surfaces used for spacecraft temperature control for Mariner IV on Mars mission

TEMPERATURE CONTROL↗

Mariner-mars absorptance experiment.

Absorptivity standard instrument to investigate solar absorptance of four surfaces used for spacecraft temperature control for Mariner IV on Mars mission

ABSORPTIVE INDEX↗

Dynamic response for thermal control and measurement and fast radiation thermometry

A preliminary evaluation was made by ORNL of a two-color ratio pyrometer (TCRP) for temperature control in the Modular Electromagnetic Levitation (MEL) experiment. A discussion was presented by Eric Spjut at the 1987 NASA Non-Contact Temperature Measurement Workshop (NASA Conf. Publ. 2503, pp. 182-213) in which he described the non-linear characteristics of the time response of TCPs. Researchers replicated his model and results and note that the non-linear response behavior is minimized for small temperature steps at high temperatures. They then used the predicted response in a model for a proportional or integral feedback controller and predicted the control characteristics for heating and cooling a 5-mm diameter sphere of niobium at high (1500 to 2750 K) temperatures. The analysis shows that for a slow (25-ms) time response for a commercial RCRP, overshoots of several hundred kelvins will result from a 100-K decrease in the setpoint, and temperature tracking errors of 14 to 45 K will occur for control temperature ramps of 1000K/s. For a fast (greater than 0.1 ms) time response, the overshoot and ramp response errors are largely eliminated.

Shepard, R. L.↗

ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.

Garrett, J. W.↗

Hypersonic research engine project. Phase 2: Structures and cooling development

The flightweight components were adapted to form the basic engine assembly. The water cooled test adapters for use in wind tunnel tests were fabricated. Commercially available valves were selected for the coolant control system. The simplification of the temperature control concept and of the absence of weight and volume constraints made it possible to use these valves. Various calibration tests are also discussed.

Jilly, L. F.↗

Heat pipe applications for the space shuttle.

Discussion of six specific applications for heat pipe (HP) devices on the space shuttle. These applications were chosen from 27 concepts formulated as part of a study to evaluate the potential benefits associated with HP use. The formulation process is briefly described along with the applications which evolved. The bulk of the discussion deals with the 'top' six - namely, HP radiators for waste heat rejection, an HP augmented cold rail, an HP circuit for electronic equipment cooling, modular heat sink for control of remote packages, an HP temperature control for compartments, and air-cooled equipment racks. The philosophy, physical design details, and performance data are presented for each concept along with a comparison with the baseline design where applicable.

Tawil, M.↗