Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A Classification of Mediterranean Cyclones Based on Global Analyses

The Mediterranean Sea region is dominated by baroclinic and orographic cyclogenesis. However, previous work has demonstrated the existence of rare but intense subsynoptic-scale cyclones displaying remarkable similarities to tropical cyclones and polar lows, including, but not limited to, an eye-like feature in the satellite imagery. The terms polar low and tropical cyclone have been often used interchangeably when referring to small-scale, convective Mediterranean vortices and no definitive statement has been made so far on their nature, be it sub-tropical or polar. Moreover, most of the classifications of Mediterranean cyclones have neglected the small-scale convective vortices, focusing only on the larger-scale and far more common baroclinic cyclones. A classification of all Mediterranean cyclones based on operational global analyses is proposed The classification is based on normalized horizontal shear, vertical shear, scale, low versus mid-level vorticity, low-level temperature gradients, and sea surface temperatures. In the classification system there is a continuum of possible events, according to the increasing role of barotropic instability and decreasing role of baroclinic instability. One of the main results is that the Mediterranean tropical cyclone-like vortices and the Mediterranean polar lows appear to be different types of events, in spite of the apparent similarity of their satellite imagery. A consistent terminology is adopted, stating that tropical cyclone- like vortices are the less baroclinic of all, followed by polar lows, cold small-scale cyclones and finally baroclinic lee cyclones. This classification is based on all the cyclones which occurred in a four-year period (between 1996 and 1999). Four cyclones, selected among all the ones which developed during this time-frame, are analyzed. Particularly, the classification allows to discriminate between two cyclones (occurred in October 1996 and in March 1999) which both display a very well-defined eye-like feature in the satellite imagery. According to our classification system, the two events are dynamically different and can be categorized as being respectively a tropical cyclone-like vortex and well-developed polar low.

Reale, Oreste↗

Ball Bearings Equipped for In Situ Lubrication on Demand

In situ systems that provide fresh lubricants to ball/race contacts on demand have been developed to prolong the operational lives of ball bearings. These systems were originally intended to be incorporated into ball bearings in mechanisms that are required to operate in outer space for years, in conditions in which lubricants tend to deteriorate and/or evaporate. These systems may also be useful for similarly prolonging bearing lifetimes on Earth. Reservoirs have been among the means used previously to resupply lubricants. Lubricant- resupply reservoirs are bulky and add complexity to bearing assemblies. In addition, such a reservoir cannot be turned on or off as needed: it supplies lubricant continuously, often leading to an excess of lubricant in the bearing. A lubricator of the present type includes a porous ring cartridge attached to the inner or the outer ring of a ball bearing (see Figure 1). Oil is stored in the porous cartridge and is released by heating the cartridge: Because the thermal expansion of the oil exceeds that of the cartridge, heating causes the ejection of some oil. A metal film can be deposited on a face of the cartridge to serve as an electrical-resistance heater. The heater can be activated in response to a measured increase in torque that signals depletion of oil from the bearing/race contacts. Because the oil has low surface tension and readily wets the bearing-ring material, it spreads over the bearing ring and eventually reaches the ball/race contacts. The Marangoni effect (a surface-tension gradient associated with a temperature gradient) is utilized to enhance the desired transfer of lubricant to the ball/race contacts during heating. For a test, a ball bearing designed for use at low speed was assembled without lubricant and equipped with a porous-ring lubricator, the resistance heater of which consumed a power of less than 1 W when triggered on by a torque-measuring device. In the test, a load of 20 lb (.89 N) was applied and the bearing was turned at a rate of 200 RPM. The lubricator control was turned on at the beginning of the test, turned off for about 800 seconds, then turned on again. As shown in Figure 2, the controlled lubricator stabilized the torque in a low range, starting immediately after initial turn-on and immediately after resumption of the lubricator control.

Marchetti, Mario↗

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗

Steps toward 8m honeycomb mirrors. VIII - Design and demonstration of a system of thermal control

Directed jets of ambient temperature air are proposed for the maintenance of low internal temperature gradients and conformity with ambient temperatures in honeycomb-structure borosilicate glass telescope mirrors. The use of greater airflow on thicker sections, to match cooling rates, and the cooling or heating of the internal, back, and edge surfaces of the mirror at the same rate established by convection on the front surface, have been tested on a full scale glass thermal model of a single honeycomb cell from an 8-m diameter mirror. The internal thermal gradient (less than 0.1 C) and ambient-temperature-change lag (less than 0.24 C) ensure minimum image degradation.

Cheng, A. Y. S.↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of thermal X/5-detector Skylab S-192 data for estimating evapotranspiration and thermal properties of soils for irrigation management

An energy budget approach to evaluating the SKYLAB X/5-detector S-192 data for prediction of soil moisture and evapotranspiration rate was pursued. A test site which included both irrigated and dryland agriculture in Southern Texas was selected for the SL-4 SKYLAB mission. Both vegetated and fallow fields were included. Data for a multistage analysis including ground, NC-130B aircraft, RB-57F aircraft, and SKYLAB altitudes were collected. The ground data included such measurements as gravimetric soil moisture, percent of the ground covered by green vegetation, soil texture, net radiation, soil temperature gradients, surface emittance, soil heat flux, air temperature and humidity gradients, and cultural practices. Ground data were used to characterize energy budgets and to evaluate the utility of an energy budget approach for determining soil moisture differences among twelve specific agricultural fields.

Moore, D. G.↗

Einstein Observatory solid state spectrometer observations of M87 and the Virgo cluster

X-ray observations of the galaxy M87 and of a region in the Virgo cluster displaced 7 arcmin from the center of M87 are reported. X-ray spectra were obtained at these two locations with the Solid State Spectrometer onboard the Einstein Observatory. Emission lines were observed in both locations, indicating the presence of heavy elements at abundances near solar. There is no strong abundance gradient, within the errors. A temperature gradient has been detected: T increases from about 1.4 keV at the position of M87 to about 3.35 keV 7 arcmin away. There is lower temperature thermal emission at the center of M87 with T about 0.6 keV, consistent with models for cooling flows in this cluster. A mass infall rate of nearly 20 solar masses/yr has been obtained. In addition to the thermal emission, a power-law component has been detected in the spectrum of M87, consistent with that observed by HEAO 1, indicating that this component probably originates in the galaxy itself. Comparison of the results with those of other observers and with theoretical models for this source indicates the presence of intracluster gas having density near 1/1000 per cu cm and temperature of about 30,000,000 K.

Lea, S. M.↗

Double Diffusive Convection in Materials Processing

A great number of crystals grown in space are plagued by convective motions which contribute to structural flaws. The character of these instabilities is not well understood but is associated with density variations in the presence of residual gravity (g-jitter). As a specific example, past HgCdTe crystal growth space experiments by Lehoczky and co-workers indicate radial compositional asymmetry in the grown crystals. In the case of HgCdTe the rejected component into the melt upon solidification is HgTe which is denser than the melt. The space grown crystals indicate the presence of three dimensional flow with the heavier HgTe-rich material clearly aligned with the residual gravity (0.55-1.55 micro g) vector. This flow stems from double-diffusive convection, namely, thermal and solutal buoyancy driven flow in the melt. The study of double-diffusive convection is multi-faceted and rather vast. In our investigation, we seek to focus on one specific aspect of this discipline that is of direct relevance to materials processing especially crystal growth, namely, the side ways heating regime. This problem has been widely studied, both experimentally and numerically, in the context of solar ponds wherein the system is characterized by a linear salt (solutal) gradient with an imposed lateral temperature gradient. The induced flow instabilities arise from the wide disparity between the fluid thermal diffusivity and the solute diffusivity. The extension of the analysis to practical crystal growth applications has however not been rigorously made and understood. One subtle but important difference in crystal growth systems is the fact that die system solute gradient is non-linear (typically exponential). Besides, the crystal growth problem has the added complexities of solidification, both lateral and longitudinal thermal gradients and segregation phenomena in systems where binary and ternary compounds are being grown. This paper treats the side ways heating problem alone in a model fluid system. Results from detailed numerical calculations, mainly two dimensional are provided. The interactions between a non-linear solute gradient and an imposed transverse thermal gradient are investigated. The buoyancy effects are treated in the traditional Boussinesq approximation and also in a more complete density formulation to address recent concerns of the first approach especially in simulations of the system response in a reduced gravity environment. Detailed flow, temperature and solute field plots along with heat and mass transfer results are presented in the paper. Implications to practical crystal growth systems as discerned from the modeling results are also explored and reported.

Ramachandra, Narayanan↗

Flight 1 technical report for experiment 74-36: Thermal migration of bubbles and their interaction with solidification interfaces

Specimens of gas saturated carbon tetrabromide were directionally solidified in a transparent furnace using a gradient freeze technique. The original temperature gradient was 5 C/cm and the cooling rate was 40 C/h. Progress of the experiment was monitored photographically. Gas bubbles were generated at the advancing solidification front in each of the three specimens. The gas bubbles were observed to increase in size, coalesce, and eventually be grown into the solid specimen under low gravity conditions. No bubble detachment from the interface was observed. Identical specimens processed in the laboratory showed bubble nucleation, bubble growth, and eventual bubble detachment due to buoyancy forces. Examination of the specimens showed a significantly greater void content in the low gravity processed samples. The grain size was observed to be finer in the low gravity processed samples.

Papazian, J. M.↗

Solar activity observed in X-rays and the EUV from OSO 7

Spectroheliograms obtained with the EUV spectroheliograph aboard OSO 7 between 1.7 and 400 A with a spatial resolution of at least 20 x 20 arc seconds are described, and results of an initial analysis of the Goddard X-ray polarimeter measurements are given and discussed in the light of current flare theories. The EUV observations are consistent with a picture in which coronal enhancement overlying an active region is made up of a nested set of arches or loops, with foot-points in regions of opposite magnetic polarity. The outermost arches are coolest, while those nearer the center are hotter. Along a given field line there is a temperature gradient such that the highest temperature occurs at the highest point of the magnetic arch. Polarimeter data provide evidence for polarization of about 20% in a number of X-ray bursts.

Thomas, R. J.↗

Critical transport parameters for porous media subjected to counterflow

Experimental and theoretical studies have been conducted to determine critical parameters at the onset of nonlinear counterflow in He II below the lambda point of He-4. Critical temperature differences have been measured in porous media for zero net mass flow and for Darcy permeabilities in the order of magnitude range from 10 to the -10th to 10 to the -8th sq cm. The normalized critical temperature gradients, which covered the liquid temperature range of 1.5 K to the lambda temperature, are found to vary with T proportional to the ratio of the superfluid density to the normal fluid density. This liquid temperature dependence appears to be consistent with duct data which are limited at low temperature by a Reynolds number criterion.

Frederking, T. H. K.↗

Effects of g-jitter and cross-diffusion on the onset of convection in doubly diffusive systems

The effects of a modulated gravity field in doubly diffusive layers with and without cross-diffusion are studied. Attention is focused on the determination of linear stability criteria for such systems. Floquet theory is used to establish the stability criteria by a systematic analysis of the topology of the neutral curves from which stability boundaries can be constructed. Convective stability boundaries for gravity-modulated doubly cross-diffusive systems are presented for the cases of dynamically free and rigid boundaries. Two physically different forms of layer stratification are considered: (1) imposed independent gradients of two components and (2) a solute gradient induced by a fixed temperature gradient.

Terrones, Guillermo↗

Elevated Temperature Crack Propagation

This paper is a summary of two NASA contracts on high temperature fatigue crack propagation in metals. The first evaluated the ability of fairly simple nonlinear fracture parameters to correlate crack propagation. Hastelloy-X specimens were tested under isothermal and thermomechanical cycling at temperatures up to 980 degrees C (1800 degrees F). The most successful correlating parameter was the crack tip opening displacement derived from the J-integral. The second evaluated the ability of several path-independent integrals to correlate crack propagation behavior. Inconel 718 specimens were tested under isothermal, thermomechanical, temperature gradient, and creep conditions at temperatures up to 650 degrees C (1200 degrees F). The integrals formulated by Blackburn and by Kishimoto correlated the data reasonably well under all test conditions.

Orange, Thomas W.↗

Estimation of surface temperature variations due to changes in sky and solar flux with elevation

The magnitude of elevation effects due to changes in solar and sky fluxes, on interpretation of single thermal images and composite products such as temperature difference and thermal inertia, are examined. Simple expressions are derived for the diurnal behavior of the two parameters, by fitting field observations in one tropic (Hawaii) and two semi-arid climates (Wyoming and Colorado) (Hummer-Miller, 1981). It is shown that flux variations with elevation can cause changes in the mean diurnal temperature gradient from -4 to -14 degrees C/km, evaluated at 2000 m. Changes in the temperature-difference gradient of 1 to 2 degrees C/km are also produced which is equivalent to an effective thermal-inertia gradient of 100 W s(exp 1/2)/sq m-K-km. An example is presented showing an elevation effect of 12 degrees C on the day and night thermal scenes of a test site in Arizona.

Hummer-Miller, S.↗

Application of HCMM data to regional geologic analysis for mineral and energy resource evaluation

The effects of topographic elevation and slope on thermal images were examined using representative field obstructions of the solar and sky radiation and a simple linearized thermal model. The forms are easily adapted for analysis of HCMM images using the DMA digital terrain data. From a representative set of field observations, it was found that flux variations with elevation can cause changes in the mean diurnal temperature gradient from -4 deg to -14 deg per km evaluated at 2000 m. Changes in the temperature difference gradient of 1 to 2 C per km are also produced which is equivalent to an effective thermal inertia gradient of 100 W s to the 1/2 power/sq m K/1 per km. Exposed bedrock on topographic ridges will appear to have a lower thermal inertia due to the additional effect.

Watson, K.↗

Study of a columnar grain structure produced in a superalloy by gradient-annealing prealloyed powder extrusions

Annealing in a temperature gradient was used to produce a structure of continuous columnar grains in alloy 713 C made by extrusion of prealloyed powder. The columnar-grained specimens had tensile strengths within plus or minus 5 percent of those of the as-cast alloy at 760 C and 980 C but were significantly stronger at room temperature. Stress-rupture tests at 760 C and 980 C showed lives scattered from 17 to 376 percent of those of as-cast 713 C tested under the same conditions. X-ray diffraction studies showed the large grains formed upon annealing to have a well-defined texture, although the as-extruded material had none.

Miner, R. V., Jr.↗

Studies of noble-metal thermocouple stability at high temperatures

Two investigatory studies on performance characteristics of noble-metal thermocouples are described. (1) thermoelectric stability as affected by preferential oxidation of iridium in the system iridium-40% rhodium versus iridium, and (2) the effects of temperature gradients on the emf stability of the systems platinum-13% rhodium versus platinum and iridium-40% rhodium versus iridium, operating in air. The stability investigation was carried out at three temperatures - 1700, 1850, and 2000 C - by comparing the output of the test thermocouple in air with the output of an identically constructed reference thermocouple in nitrogen. The results show that no calibration shift was observed producing a change in output greater than that corresponding to a 2.0% change in the indicated temperature for all samples tested. The investigation of gradient effects was carried out by subjecting test thermocouples to both severe and mild gradients for periods up to 200 hours. For the platinum system, the operating temperature was 1500 C with gradients of 1475 and 700 C/cm; for the iridium system, 2000 C with gradients of 700, 1500, and 1975 C/cm. Exposure to temperature gradients was found to introduce significant changes in calibration for both systems. In both investigations, the thermoelements were examined by means of electron-probe analysis and by metallographic methods to detect chemical and structural changes. Data and micrographs are presented.

Freeze, P.↗

Surface-tension-driven flow in a glass melt

Motion driven by surface tension gradients was observed in a vertical capillary liquid bridge geometry in a sodium borate melt. The surface tension gradients were introduced by maintaining a temperature gradient on the free melt surface. The flow velocities at the free surface of the melt, which were measured using a tracer technique, were found to be proportional to the applied temperature difference and inversely proportional to the melt viscosity. The experimentally observed velocities were in reasonable accord with predictions from a theoretical model of the system.

Mcneil, Thomas J.↗