Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Random Variation of ACRR Core Report

The research presented in this paper is to be a contribution to a larger research project. The project was designed to test the safety standards of Sandia National Laboratories' ACRR. The MCNP model of the ACRR core is being used to simulate the environment. To test the safety standards, the dimensions and density of the fuel in the core were varied randomly. Each rod had its own dimension and density assigned to it randomly. Ten different cases of the ACRR core were randomly created. The different cases were studied using 640-group neutron fluxes. The fluxes were compared to see how the variations affected the system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Planning Roadmap for DER Integration in India: Industry Best Practices and Resource Guide

Ensuring safe, reliable, cost-effective DER integration at scale requires holistic planning, broad stakeholder engagement, and should address key development areas such as standards adoption, equipment testing and certification, interoperability and cybersecurity, interconnection procedures, and advanced forecasting and DER management. Each of these areas currently represent significant challenges for utilities, regulators, OEMs, developers, and even consumers worldwide. India has already seen significant growth of DERs and has announced targets for substantial growth yet to come, with the potential for DERs to make up a non-negligible portion of the country's overall generation capacity. As such, it is of critical importance that Indian stakeholders consider the potential impacts of wide-spread adoption of DERs and take preemptive action related to the five development areas listed here, among others. India should consider strategies including the adoption of key DER standards related to interconnection, testing, and cybersecurity; enabling effective and secure communication channels for DER interoperability; testing and certifying DER equipment in accredited testing laboratories; building robust, streamlined interconnection procedures; and revamping legacy system planning structures to incorporate DERs in a holistic planning framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Properties of Oxymethylene Ethers with Terminating Groups from Methyl to Butyl

Oxymethylene ethers (OMEs) have been studied as possible additives or replacements for diesel fuels. Typically, studies have considered only methyl-terminated OMEs. Recent structure-property relationship models suggest that extended-alkyl OMEs may provide improvements to many of the properties of methyl-terminated OMEs that make them less suitable as diesel fuel blendstocks. In this work, we describe the synthesis and characterization of 16 different OMEs with methyl, ethyl, propyl, butyl, isopropyl, and isobutyl terminating alkyl groups with varying oxymethylene chain length. Indicated Cetane Number, Lower Heating Value, Flash Point, Density, Viscosity, Vapor Pressure, and Oxidative Stability are tested via ASTM standard methods. Additionally, Water Solubility, Boiling Point, seal material compatibility, and sooting propensity (via the Yield Sooting Index) are measured for these fuels. For diesel compatibility, all tested OMEs except smaller methyl and ethyl OMEs, and the branched isopropyl OME, meet cetane number requirements. Further, extending the alkyl end group increases the heating value, but all OMEs, due to their oxygen content, have heating values less than diesel; despite this, all OMEs show significant reductions in soot production per unit heating value. Only the heaviest OMEs meet diesel viscosity requirements, and most are higher density than diesel. OMEs with larger alkyl groups show the highest stability under accelerated auto-oxidation conditions. Increases in alkyl group length cause order of magnitude reduction in water solubility, from hundreds of g/L for methyl terminated OMEs to hundreds of mg/L for butyl terminated OMEs. Limited seal material testing indicates that PEEK polymers are unaffected by OMEs; while extended alkyl groups may improve compatibility with FKM (Viton), other common elastomers (NBR, silicone) remain incompatible with all tested OMEs. Overall, it is found that methyl-terminated OMEs exhibit the most potential for soot reduction, but OMEs with larger propyl and butyl terminating alkyl groups show improved compatibility with existing diesel systems.

09 BIOMASS FUELS↗

ORNL Package Testing Program Overview

When transporting radioactive or hazardous materials, safety and security are top priorities. Packaging and transportation regulations require reliable evidence that containers have passed rigorous performance tests to ensure that the public and the environment are protected from the hazardous nature of the cargo. Because of its long history in energy and security research, Oak Ridge National Laboratory (ORNL) has needed to ship hazardous packages for the past 65 years. Since the 1940s, ORNL has made significant contributions to transportation regulations and has been at the forefront of regulatory testing development. Today, ORNL is a leader in standards development and testing of designs of radioactive material packages. ORNL plays a critical role in ensuring the safe transportation of radioactive materials across the United States by executing rigorous testing campaigns of packages that contain radioactive materials. Early testing activities focused on supporting the development of transportation regulations established by both the International Atomic Energy Agency (IAEA) and the United States. Currently, all package testing activities are performed under the Package Testing Program (PTP) at the Package Evaluation Facility (PEF) located at the National Transportation Research Center (NTRC), which is about 10 miles from the main ORNL campus. The PTP develops and evaluates testing solutions, ensuring that they are safe efficient, and in compliance with regulatory requirements. The vision for the PTP is to be a world-class leader in the evaluation and testing of radioactive and hazardous material packages. The key elements necessary to fulfill this mission are an experienced and professional staff; state-of-the-art facilities, equipment, and instrumentation; and completion of challenging programs and projects important to package transportation. Collaborations with other internal and external organizations play a significant role in building stronger teams and achieving this vision. By adhering to and advancing regulatory standards, ORNL’s PTP supports development of safe and compliant packaging, safeguarding the transportation process from potential risks associated with radioactive material logistics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Critical Compression Ratio on Rating Gasoline Knock Propensity

It is common practice in the automotive industry to explore the knock limits of fuels on an engine by a comparison of the knock limited spark advance (KLSA) at threshold knock intensity. However, the knock propensity of gasolines can be rated by changing one of three metrics on a variable compression ratio Cooperative Fuels Research (CFR) octane rating engine while holding the other two variables constant: knock intensity, spark timing, and critical compression ratio. The operational differences between the standard research octane number (RON) rating and modern engine operation have been explored in three parts. The first part focused on the effects of lambda and knock characterization. The second part studied the effects of spark timing. This third part explores the knock ratings of several gasolines by comparing the critical compression ratios at constant combustion phasing and knock intensity. The threshold knock intensity was based on the standard octane rating D1 pickup or by maximum amplitude of pressure oscillations (MAPO) measured by a piezoelectric cylinder pressure transducer. Several Fuels for Advanced Combustion Engines (FACE) gasolines, primary reference fuels (PRFs), and toluene standardization fuels (TSFs) were tested on a CFR octane rating engine with advanced data acquisition equipment and a piezoelectric cylinder pressure transducer. These tests deviated from the ASTM D2699 standard octane rating procedure. For each test fuel, the CFR engine was operated at stoichiometry at a constant combustion phasing (CA50) and the compression ratio was modified until a threshold knock intensity was realized. It was found that the chemical composition of the fuels affected the relationship of critical compression ratios between the D1 knockmeter and piezoelectric pressure transducer knock intensity thresholds, as well as the measured combustion maximum pressure rise rate and spark timing setting for constant CA50. For highly aromatic fuels tested at a constant MAPO knock intensity threshold, it was found that the maximum pressure rise rate was two to three times higher than that of highly paraffinic fuels with similar RON and the spark advance was several crank angle degrees less for constant combustion phasing.

Kolodziej, Christopher P↗

Advancing reliability assessments of photovoltaic modules and materials using combined-accelerated stress testing

Previously undiscovered failure modes in photovoltaic (PV) modules continue to emerge in field installations despite passing protocols for design qualification and quality assurance. Failure to detect these modes prior to widespread use could be attributed to the limitations of present-day standard accelerated stress tests (ASTs), which are primarily designed to identify known degradation or failure modes at the time of development by applying simultaneous or sequential stress factors (usually two at most). Here, we introduce an accelerated testing method known as the combined-accelerated stress test (C-AST), which simultaneously combines multiple stress factors of the natural environment. Simultaneous combination of multiple stress factors allows for improved identification of failure modes with better ability to detect modes not known a priori. A demonstration experiment was conducted that reproduced the field-observed cracking of polyamide- (PA-) and polyvinylidene fluoride (PVDF)–based backsheet films, a failure mode that was not detected by current design qualification and quality assurance testing requirements. In this work, a two-phase testing protocol was implemented. The first cycle (“Tropical”) is a predominantly high-humidity and high-temperature test designed to replicate harsh tropical climates. The second cycle (“Multi-season”) was designed to replicate drier and more temperate conditions found in continental or desert climates. Testing was conducted on 2 × 2-cell crystalline-silicon cell miniature modules constructed with both ultraviolet (UV)–transmitting and UV-blocking encapsulants. Cracking failures were observed within a cumulative 120 days of the Tropical condition for one of the PA-based backsheets and after 84 days of Tropical cycle followed by 42 days of the Multi-season cycle for the PVDF-based backsheet, which are both consistent with failures seen in fielded modules. In addition to backsheet cracking, degradation modes were observed including solder/interconnect fatigue, various light-induced degradation modes, backsheet delamination, discoloration, corrosion, and cell cracking. The ability to simultaneously apply multiple stress factors may allow many of the test sequences within the standardized design qualification procedure to be performed using a single test setup.

14 SOLAR ENERGY↗

MEMOTE for standardized genome-scale metabolic model testing

Reconstructing metabolic reaction networks enables the development of testable hypotheses of an organism’s metabolism under different conditions. State-of-the-art genome-scale metabolic models (GEMs) can include thousands of metabolites and reactions that are assigned to subcellular locations. Gene–protein–reaction (GPR) rules and annotations using database information can add meta-information to GEMs. GEMs with metadata can be built using standard reconstruction protocols, and guidelines have been put in place for tracking provenance and enabling interoperability, but a standardized means of quality control for GEMs is lacking. Here we report a community effort to develop a test suite named MEMOTE (for metabolic model tests) to assess GEM quality.

59 BASIC BIOLOGICAL SCIENCES↗

Probing the role of solids loading and mix procedure on the properties of acoustically mixed materials for additive manufacturing

We report resonant acoustic mixing has been of particular interest for use in additive manufacturing since viscous, solids-loaded materials can be difficult to mix and inhomogeneity has adverse effects on print quality. In this study, we detail a method to iterate through different formulations and mix procedures and assess mixture quality. The approach utilizes a constant pressure-driven flow test to collect statistics on flow rate through a standard geometry. This test is first applied to well mixed formulations containing particulate solids and find that the results are sensitive to viscosity produced by solids content. We then consider the formulations at various stages of mixing and find that the spread in the volume measurements is indicative of the mixing quality; poorly mixed material yields measurements with wide distributions. We believe this testing approach can be useful when screening new formulations, developing mixing processes, or for quality control.

36 MATERIALS SCIENCE↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pyctos

Pyctos is a concolic testing framework for standard, dynamically-typed Python. Pyctos is able to generate exhaustive test inputs reaching 100% coverage for a subset of pure Python in the absence of type annotations, even where modern fuzzers would fail. Pyctos's underlying reasoning engine is the CVC5 SMT solver, though Z3 is also supported. Pyctos also supports a growing subset of the standard library and some third-party libraries, such as NumPy.

Washbourne, ErickN [Lawrence Livermore National La↗

Update of ASHRAE Standard 140 Section 5.2 and Related Sections (BESTEST Building Thermal Fabric Test Cases)

This report documents new work intended to update the current building thermal fabric software-to-software comparative test specifications and example results of ANSI/ASHRAE Standard 140-2017, Sections 5.2.1, 5.2.2, 5.2.3, and related supporting sections. The Building Energy Simulation Test and Diagnostic Method (BESTEST) test specification and example results that provide the basis for these Standard 140 sections were originally published in 1995. The state of the art in building energy simulation modeling has advanced since then. Additionally, comments on the test specification over the years highlighted ambiguities, further necessitating the update to the original work. This new work was conducted for the U.S. Department of Energy (DOE) by Argonne National Laboratory (Argonne) and National Renewable Energy Laboratory (NREL), in collaboration with a working group of international experts associated with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standing Standard Project Committee (SSPC) 140. SSPC 140 is responsible for ANSI/ASHRAE Standard 140. The new work, presented in this report, defined the test cases and specifications such that building energy simulation programs with time steps of one hour or less can perform the tests. Revisions to the test specification and update of example results follow the vetting process of iterative field trials established for previous BESTEST work that has been adapted for ASHRAE Standard 140.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental program with high duty-cycle polarized and unpolarized positron beams at Jefferson Lab

Positron beams, both polarized and unpolarized, are identified as important ingredients for the experimental programs at the next generation of lepton accelerators. In the context of the hadronic physics program at Jefferson Lab (JLab), positron beams are complementary, even essential, tools for a precise understanding of the electromagnetic structure of nucleons and nuclei, in both the elastic and deep-inelastic regimes. For instance, elastic scattering of polarized and unpolarized electrons and positrons from the nucleon enables a model independent determination of its electromagnetic form factors. Also, the deeply-virtual scattering of polarized and unpolarized electrons and positrons allows unambiguous separation of the different contributions to the cross section of the lepto-production of photons and of lepton-pairs, enabling an accurate determination of the nucleons and nuclei generalized parton distributions, and providing an access to the gravitational form factors of the energy-momentum tensor. Furthermore, positron beams offer the possibility of alternative tests of the Standard Model of particle physics through the search of a dark photon, the precise measurement of electroweak couplings, and the investigation of charged lepton flavor violation. This document discusses the perspectives of an experimental program with high duty-cycle positron beams at JLab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Transformer Testing Approach Reduces Reactor Down Time

The ATR-774 transformer yard has been in operation for 57 years. It's old, outdated, and reaching end of life. Plant health has decided to construct a new transformer yard, which will require testing. I've explored the standards library and compiled a list of tests that need to be performed on the transformer yard. This effort led to a significant speed-up in the testing process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Bureau of Standards Reactor LEU Fuel Element Flow Test Conceptual Design

As part of the U.S. National Nuclear Security Administration’s (NNSA’s) mission to eliminate or minimize the civilian use of weapon-grade highly enriched uranium (HEU) fuels, the NNSA Office of Material Management and Minimization (M 3 ) Reactor Conversion Program is collaborating with six U.S. High Performance Research Reactors (USHPRR), including one critical facility, to convert from the use of HEU to low-enriched uranium (LEU) fuel. The M3 conversion objectives for the USHPRR are to develop LEU fuel element designs that will ensure safe reactor operations and maintain the existing experimental performance of each facility. The work is being conducted through many interrelated activities that are being completed by stakeholders across organizations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Standardizing an Intermediate-Scale High Explosive Safety Test Suite

Small-scale safety testing, while successful in screening out extremely dangerous explosive compositions, does not fully characterize the explosive hazards associated with handling larger, consolidated or bare charges. It is proposed that intermediate-scale tests using consolidated charges in the range 25 mg – 1 kg are warranted to satisfactorily address the hazards. A standard for this intermediate-scale testing should be developed, proofed, peer-reviewed and adopted to assist in the development of safe new high explosive compositions across the complex. This whitepaper explains why current small-scale safety testing is insufficient to characterize the handling hazard, identifies the guiding aspects of explosive response that drive the handling hazards associated with larger consolidated charges, and proposes a suite of tests/experiments that can serve as a starting point for an intermediate-scale safety standard.

42 ENGINEERING↗

Novel Geochemistry Determined from High Pressure, High Temperature Simulation Experiments of Hydraulic Fracture Test Site 2

A standard method in unconventional oil and gas production is the process of hydraulic fracturing followed by a shut-in period, during which the fracture fluid remains pressurized in the reservoir for up to three weeks before production begins. Despite this widely used process, very little is known about what occurs in the reservoir during this shut-in process. In order to properly delineate potential reservoir reactions that may occur during shut-in that would lead to corrosion and scaling events, experiments were conducted in high pressure, high temperature reactors to simulate conditions of the Wolfcamp Formation in the Delaware Basin. Experimental design allowed the assessment of the effect of proppant, microbiology, and time on the mineralogy and fluid chemistry in the reservoir. Results suggest the biggest impact on fluid chemistry and shale mineralogy during shut-in is time. Analyses demonstrate dissolution of the shale material, with maximum dissolved ions occurring after 7 days of the shut-in period. After 21 days, results suggest precipitation occurs. The Delaware Basin is demonstrated to be high in sulfate content, which further increases in the fluid due to dissolution reactions during shut-in. The pressure vessel experiments suggest there was no significant contribution to reactions from microbiology during the shut-in period. Furthermore, early production samples demonstrate a significant selection of the microorganism Caminicella, a genus of which has previously been correlated to corrosion and sulfide production. Results suggest shut-in conditions may provide high sulfate concentrations that could later be utilized by a shifted microbial community to drive potential well infrastructure failure. This is the first study to incorporate microbiology, mineralogy, and fluid chemistry to investigate the fundamental geochemical reactions that occur during shut-in and early phase production of the Delaware Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S032R001/2477425/urtec-2021-5219-ms.pdf/1 by Carol Worster on 28 February 2022 Basin. Results from this study can complement observations from the Hydraulic Fracture Test Site 2 observations

58 GEOSCIENCES↗