CRADA Number NFE-19-07846 with Grid Fruit, LLC (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07846 between Oak Ridge National Laboratory (ORNL) and Grid Fruit, LLC (Grid Fruit) focused on simulating, monitoring, and adjusting controls of commercial refrigerator and freezer systems to provide load flexibility and demand response services from these machines. Viewing these medium and low-temp coolers as thermal masses, the volumes of chilled air in these coolers make them time-shiftable loads ripe for deployment at optimal times. Grid Fruit is a startup company developing methods to schedule the chilling cycles (e.g., in “build load” and “shed load” grid events) to provide energy efficiency, peak shifting, and other benefits both to the grid and the broader environment. These benefits can be magnified by coordinating chillers with HVAC, lights, computers, and other loads. Grid Fruit completed simulations and then selected and ordered controls hardware to prove the technology were successful, but the diversity of chiller models in the field without digital controls, as well as limited market demand at present, make further exploration necessary before commercialization.

42 ENGINEERING↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NMPC for Mode-Switching Operation of Reversible Solid Oxide Cell Systems

Solid oxide cells (SOCs) are a promising dual-mode technology that generates hydrogen through high-temperature water electrolysis and generates power through a fuel cell reaction that consumes hydrogen. Reversible operation of SOCs requires a transition between these two modes for hydrogen production setpoints as the demand and price of electricity fluctuate. Moreover, a well-functioning control system is important to avoid cell degradation during mode-switching operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional integral (PI) control strategies, while ramping between the modes of hydrogen and power production. While both control methods provide similar performance in many metrics, NMPC significantly reduces cell thermal gradients and curvatures (mixed spatial-temporal partial derivatives) during mode switching. A dynamic process flowsheet of the reversible SOC system was developed in the open-source, equation-based IDAES modeling framework. Our IDAES dynamic simulation results show that NMPC can ramp the SOC system between hydrogen and power production targets within short mode-switching times. Moreover, NMPC can comply with operating limits in the SOC system more effectively than PI, and only NMPC can directly enforce user-specified limits for mixed spatial-temporal partial derivatives of temperature. This allows for management of the trade-off be-tween operating efficiency and cell degradation, which is dependent on these temperature curvatures.

Li, Mingrui↗

Thermodynamic Properties and Molecular Packing Explain Performance and Processing Procedures of Three D18:NFA Organic Solar Cells

Abstract Organic solar cells (OSCs) based on D18:Y6 have recently exhibited a record power conversion efficiency of over 18%. The initial work is extended and the device performance of D18‐based OSCs is compared with three non‐fullerene acceptors, Y6, IT‐4F, and IEICO‐4Cl, and their molecular packing characteristics and miscibility are studied. The D18 polymer shows unusually strong chain extension and excellent backbone ordering in all films, which likely contributes to the excellent hole‐transporting properties. Thermodynamic characterization indicates a room‐temperature miscibility for D18:Y6 and D18:IT‐4F near the percolation threshold. This corresponds to an ideal quench depth and explains the use of solvent vapor annealing rather than thermal annealing. In contrast, D18:IEICO‐4Cl is a low‐miscibility system with a deep quench depth during casting and poor morphology control and low performance. A failure of ternary blends with PC 71 BM is likely due to the near‐ideal miscibility of Y6 to begin with and indicates that strategies for developing successful ternary or quaternary solar cells are likely very different for D18 than for other high‐performing donors. This work reveals several unique property–performance relations of D18‐based photovoltaic devices and helps guide design or fabrication of yet higher efficiency OSCs.

Wang, Zhen↗

Qubit spin ice

Artificial spin ices are frustrated spin systems that can be engineered, in which fine tuning of geometry and topology has allowed the design and characterization of exotic emergent phenomena at the constituent level. Here, we report a realization of spin ice in a lattice of superconducting qubits. Unlike conventional artificial spin ice, our system is disordered by both quantum and thermal fluctuations. The ground state is classically described by the ice rule, and we achieved control over a fragile degeneracy point, leading to a Coulomb phase. The ability to pin individual spins allows us to demonstrate Gauss’s law for emergent effective monopoles in two dimensions. The demonstrated qubit control lays the groundwork for potential future study of topologically protected artificial quantum spin liquids.

36 MATERIALS SCIENCE↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Grid-scale Energy Storage Hazard Analysis & Design Objectives for System Safety

Battery based energy storage systems are becoming a critical part of a modernized, resilient power system. However, batteries have a unique combination of hazards that can make design and engineering of battery systems difficult. This report presents a systematic hazard analysis of a hypothetical, grid scale lithium-ion battery powerplant to produce sociotechnical "design objectives" for system safety. We applied system's theoretic process analysis (STPA) for the hazard analysis which is broken into four steps: purpose definition, modeling the safety control structure, identifying unsafe control actions, and identifying loss scenarios. The purpose of the analysis was defined as to prevent event outcomes that can result in loss of battery assets due to fires and explosions, loss of health or life due to battery fires and explosions, and loss of energy storage services due to non- operational battery assets. The STPA analysis resulted in identification of six loss scenarios, and their constituent unsafe control actions, which were used to define a series of design objectives that can be applied to reduce the likelihood and severity of thermal events in battery systems. These design objectives, in all or any subset, can be utilized by utilities and other industry stakeholders as "design requirements" in their storage request for proposals (RFPs) and for evaluation of proposals. Further, these design objectives can help to protect firefighters and bring a system back to full functionality after a thermal event. We also comment on the hazards of flow battery technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Evaluation of a Next-Generation High-Temperature Particle Receiver for Concentrating Solar Thermal Applications

High-temperature particle receivers are being developed to achieve temperatures in excess of 700 °C for advanced power cycles and solar thermochemical processes. This paper describes designs and features of a falling particle receiver system that has been evaluated and tested at the National Solar Thermal Test Facility at Sandia National Laboratories. These advanced designs are intended to reduce heat losses and increase the thermal efficiency. Novel features include aperture covers, active air flow, particle flow obstructions, and optimized receiver shapes that minimize advective heat losses, increase particle curtain opacity and uniformity, and reduce cavity wall temperatures. Control systems are implemented in recent on-sun tests to maintain a desired particle outlet temperature using an automated closed-loop proportional–integral–derivative controller. These tests demonstrate the ability to achieve and maintain particle outlet temperatures approaching 800 °C with efficiencies between 60 and 90%, depending on incident power, mass flow, and environmental conditions. Lessons learned regarding the testing of design features and overall receiver operation are also presented.

Mills, Brantley H.↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Photonic Refrigeration from Time-Modulated Thermal Emission

We develop theoretical and computational formalisms to describe thermal radiation from temporally modulated systems. We demonstrate that such a modulation results in a photon-based active cooling mechanism. This mechanism has a high thermodynamic performance that can approach the Carnot limit. Our work points to exciting new avenues in active, time-modulated control of thermal emission for cooling and energy harvesting applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum computing universal thermalization dynamics in a (2 + 1)D Lattice Gauge Theory

Simulating non-equilibrium phenomena in strongly-interacting quantum many-body systems, including thermalization, is a promising application of near-term and future quantum computation. By performing experiments on a digital quantum computer consisting of fully-connected optically-controlled trapped ions, we study the role of entanglement in the thermalization dynamics of a Z 2 lattice gauge theory in 2+1 spacetime dimensions. Using randomized-measurement protocols, we efficiently learn a classical approximation of non-equilibrium states that yields the gap-ratio distribution and the spectral form factor of the entanglement Hamiltonian. These observables exhibit universal early-time signals for quantum chaos, a prerequisite for thermalization. Our work, therefore, establishes quantum computers as robust tools for studying universal features of thermalization in complex many-body systems, including in gauge theories.

97 MATHEMATICS AND COMPUTING↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Automated Production of Optimization-Based Control Logics for Dynamic Facade Systems, with Experimental Application to Two-Zone External Venetian Blinds

The primary goal of this research is to devise a system that produces controllers for complex fenestration systems that perform nearly as well as Model Predictive Control but at a level of cost and implementation complexity that rivals simple heuristic controls. To this end, a cloud-based automated controller production system has been set up for a motorized external Venetian blind device, with a simple web interface that can be used by non-experts. The computation cost per controller is in the range of a few dollars, and the control logic is simple enough to be implemented on small and cheap distributed controllers. The web interface allows the user to specify some details of their particular building and window configuration, including orientation, latitude, interior geometries, and lighting and HVAC system parameters. Upon submittal, a cloud-based system configures the necessary files and commands, and then runs thousands of optimizations with them. Once the calculations are finished, the system produces a lookup table and interpolation-based controller scripts that can be used on a simple and cheap distributed controller. This paper describes the underlying models and optimization processes. It also describes the resulting control logics for two cases tested at Lawrence Berkeley National Laboratory’s Advanced Windows Testbed Facility: illuminance maximization subject to glare constraints; and lighting + HVAC energy minimization. The performance of the model-based controllers produced by the automated web-based system are compared to a heuristic ‘block beam’ controller in physical experiments at the Testbed. The experimental results are supplemented by simulation experiments with the same configuration as the Testbed. The results show the illuminance maximizing controller significantly outperforms the heuristic controller in terms of glare avoidance, and also outperforms it in terms of hours of daylight autonomy. The energy minimizing controller also outperforms the heuristic controller. This paper also discusses how the web-based system may be extended to consider other configurations, such as electrochromic windows and thermally massive HVAC systems. Potential roles for this type of system within the building design and construction industry are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗