Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Accurate and inexpensive thermal time-of-flight sensor for measuring refrigerant flow in minichannels

Thermal flow meters are good candidates for measuring flow rates in small diameter channels because they can be integrated into compact geometries and consist of only a few simple components. A new thermal time-of-flight (TOF) flow sensor is developed in this report for measuring liquid refrigerant velocities in minichannels. The sensor consists of a small heater and two downstream thermocouples. The heater is pulsed to induce a temperature rise in the fluid, and the time for the temperature pulse to reach the downstream thermocouples is measured. Insights from the data and a simplified one-dimensional transient model are used to calibrate the device. The calibration relates the time of flight to both the average refrigerant velocity and local temperature gradients in the fluid. The calibrated TOF device can detect refrigerant velocities between 1 and 20, mm s -1 , measuring 98.7% of the data to within ±3% of the full scale (±0.6 mm s -1 ).

42 ENGINEERING↗

Impact of the Screen Configurations on the Estimated Terra MODIS SD Degradation

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board the Aqua and Terra spacecraft have collected valuable Earth data for the last 19 and 21 years, respectively. MODIS is equipped with various on-orbit calibrators, including a solar diffuser (SD) and solar diffuser stability monitor (SDSM), that are used to monitor changes in the instrument’s gain over time. Nominally, SD calibrations alternate between two configurations: screen open and screen closed. Terra MODIS, however, experienced an anomaly in 2003, which has left the SD door and screen in a permanent open-closed configuration. This resulted in accelerated degradation of the SD on Terra MODIS due to the direct solar radiation exposure every orbit. It also led to an unexpected divergence between the calibration coefficients, m1, or the inverse of the gain, generated using SD data and those generated using lunar observations at the time of the 2003 anomaly. This paper examines the effect of the screen configuration on the Terra SD degradation by analyzing Terra SDSM data and comparing to Aqua. We generate “pseudo-open” Terra SDSM data by modeling the ratio of Aqua screen open and screen closed SDSM data and calculate the Terra SD degradation using this new screen open data. We then examine the effects on our m1 values calculated using this new pseudo-open SD degradation for Terra. Implementing this new degradation results in a smaller discrepancy between the lunar and SD m1 values after the door anomaly, indicating that there may be a systematic error in the SD degradation calculated with screen closed data.

MODIS↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

PTTI applications at the limits of GPS

Canadian plans for precise time and time interval services are examined in the light of GPS capabilities developed for geodesy. We present our experience in establishing and operating a geodetic type GPS station in a time laboratory setting, and show sub-nanosecond residuals for time transfer between geodetic sites. We present our approach to establishing realistic standard uncertainties for short-term frequency calibration services over time intervals of hours, and for longer-term frequency dissemination at better than the 10(exp -15) level of accuracy.

Douglas, Rob J.↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A Report on the Validation of Beryllium Strength Models

This report discusses work on validating beryllium strength models with flyer plate and Taylor rod experimental data. Strength models are calibrated with Hopkinson bar and quasi-static data. The Hopkinson bar data for beryllium provides strain rates up to about 4000 per second. A limitation of the Hopkinson bar data for beryllium is that it only provides information on strain up to about 0.15. The lack of high strain data at high strain rates makes it difficult to distinguish between various strength model settings. The PTW model has been calibrated many different times over the last 12 years. The lack of high strain data for high strain rates has resulted in these calibrated PTW models for beryllium exhibiting significantly different behavior when extrapolated to high strain. For beryllium, the α parameter of PTW has recently been calibrated to high precision shear modulus data. In the past the α value for beryllium was set based on expert judgment. The new α value for beryllium was used in a calibration of the beryllium PTW model by Sky Sjue. The calibration by Sjue used EOS table information to model the temperature dependence of the heat capacity. Also, the calibration by Sjue used EOS table information to model the density changes of the beryllium sample during the Hopkinson bar and quasi-static experiments. In this paper, the calibrated PTW model by Sjue is compared against experimental data and other strength models. The other strength models being considered are a PTW model calibrated by Shuh- Rong Chen and a Steinberg-Guinan type model by John Pedicini. The three strength models are used in a comparison against flyer plate and Taylor rod data. The results show that the Chen PTW model provides better agreement to this data. The Chen PTW model settings have been previously adjusted to provide a better fit to flyer plate data, whereas the Sjue PTW model has not been changed based on flyer plate data. However, the Sjue model provides a reasonable fit to flyer plate and Taylor rod data, and also gives a better match to recently analyzed Z-machine data which has a strain of about 0.35 and a strain rate of 3e5 s -1 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computational and experimental study of laminar flames

During the past three years, our research has centered on an investigation of the effects of complex chemistry and detailed transport on the structure and extinction of hydrocarbon flames in coflowing axisymmetric configurations. We have pursued both computational and experimental aspects of the research in parallel on both steady-state and time-dependent systems. The computational work has focused on the application of accurate and efficient numerical methods for the solution of the steady-state and time-dependent boundary value problems describing the various reacting systems. Detailed experimental measurements were performed on axisymmetric coflow flames using two-dimensional imaging techniques. Previously, spontaneous Raman scattering, chemiluminescence, and laser-induced fluorescence were used to measure the temperature, major and minor species profiles. Particle image velocimetry (PIV) has been used to investigate velocity distributions and for calibration of time-varying flames. Laser-induced incandescence (LII) with an extinction calibration was used to determine soot volume fractions, while soot surface temperatures were measured with three-color optical pyrometry using a color digital camera. A blackbody calibration of the camera allows for determination of soot volume fraction as well, which can be compared with the LII measurements. More recently, we have concentrated on a detailed characterization of soot using a variety of techniques including time-resolved LII (TiRe-LII) for soot primary particles sizes, multi-angle light scattering (MALS) for soot radius of gyration, and spectrally-resolved line of sight attenuation (spec-LOSA). Combining the information from all of these soot measurements can be used to determine the soot optical properties, which are observed to vary significantly depending on spatial location and fuel dilution. Our goal has been to obtain a more fundamental understanding of the important fluid dynamic and chemical interactions in these flames so that this information can be used effectively in combustion modeling.

02 PETROLEUM↗

An extended radar relative calibration adjustment (eRCA) technique for higher-frequency radars and range–height indicator (RHI) scans

Abstract. This study extends the relative calibration adjustment technique for calibration of weather radars to higher-frequency radars as well as range–height indicator (RHI) scans. The calibration of weather radars represents one of the most dominant sources of error for their use in a variety of fields including quantitative precipitation estimation and model comparisons. While most weather radars are routinely calibrated, the frequency of calibration is often less than required, resulting in miscalibrated time periods. While full absolute calibration techniques often require the radar to be taken offline for a period of time, there have been online calibration techniques discussed in the literature. The relative calibration adjustment (RCA) technique uses the statistics of the ground clutter surrounding the radar as a monitoring source for the stability of calibration but has only been demonstrated to work at S- and C-band for plan-position indicator (PPI) scans at a constant elevation. In this work the RCA technique is modified to work with higher-frequency radars, including Ka-band cloud radars. At higher frequencies the properties of clutter can be much more variable. This work introduces an extended clutter selection procedure that incorporates the temporal stability of clutter and helps to improve the operational stability of RCA for relatively higher-frequency radars. The technique is also extended to utilize range–height scans from radars where the elevation is varied rather than the azimuth. These types of scans are often utilized with research radars to examine the vertical structure of clouds. The newly extended technique (eRCA) is applied to four Department of Energy Atmospheric Radiation Measurement (DOE ARM) weather radars ranging in frequency from C- to Ka-band. Cross comparisons of three co-located radars with frequencies C, X, and Ka at the ARM Cloud, Aerosol, and Complex Terrain Interactions (CACTI) site show that the technique can determine changes in calibration. Using an X-band radar at the ARM Eastern North Atlantic (ENA) site, we show how the technique can be modified to be more resilient to clutter fields that show increased variability, in this case due to sea clutter. The results show that this technique is promising for a posteriori data calibration and monitoring.

47 OTHER INSTRUMENTATION↗

Satellite Sea Ice Measurements in the Arctic Ocean

Satellite observations sustained since 1979 have been the primary source of information to reveal Arctic Ocean sea ice extent is diminishing rapidly. Sea ice is also thinning based on historical surface and near-surface records and more recent satellite retrievals. There is a new “normal” environment in the Arctic environment with substantial socio-economic impacts. A key question is: What are the spatial and temporal characteristics of the sea ice thickness distribution throughout the annual cycle, and what is the evolving inter-annual trend? Arctic Ocean sea ice conditions have been determined with passive microwave radiometer, active scatterometer and other satellite instrument measurements recorded by a continuing series of satellites. An important feature of the continuous time series measurements has been the overlap of each new satellite dataset with ongoing measurements so as to provide adequate time intervals for calibration and validation. Satellite instrument diversity has provided both coarse spatial resolution measurements over the entire Arctic Ocean for long-period time series and limited-duration fine spatial resolution data over selected regions for navigation and other applications. Satellite observations of Arctic Ocean sea ice will continue to increase in importance because predictability of sea ice is poor and societal interest is great. Unfortunately, however the sustainability of some critical elements of the current Arctic Ocean satellite measurement suite beyond 2020 remains uncertain, e.g., after the CryoSat-2 and ICESat-2 missions have concluded.

Halpern, David↗

GOES-16 ABI Solar Reflective Channel Validation for Earth Science Application

This paper presents the validation results of GOES-16 Satellite's Advanced Baseline Imager (ABI) obtained from a reflectance-based field campaign undertaken at the Salar de Uyuni in Bolivia in June 2017. In situ ground measurements are used to characterize the surface reflectance and the atmosphere in order to constrain the radiative transfer code and predict at-sensor reflectance (also referred to as top-of-atmosphere (TOA) reflectance) to compare with concurrent GOES-16 ABI measurements. The five-day field campaign provided repeated TOA reflectance estimates, allowing assessment not only of the calibration accuracy of the ABI reflective channels 1, 2, 3, 5 and 6, but also of its stability over the duration of the campaign. The results show that the accuracy of the ABI reflective channels calibration is within specification for channels 1, 3, 5, and 6 - average biases within 2%; for channel 2 the bias is 5%. The estimated uncertainty on the derived biases is 2–2.4%. Some calibration stability issues were present in the ABI calibration at the time of the campaign: (i) a jump on the order of 2% in channels 1 and 6, coincident with an ABI solar calibration event, reflects an instability of the ABI gains in these channels, and (ii) short-term variability in channels 1 and 2 is due to striping (ABI detector-todetector calibration differences). Continued validation and subsequent reprocessing of ABI reflectance imagery would allow Earth scientists to fully benefit from the high spatial and spectral fidelity of the GOES-16 ABI diurnal measurements at the continental scale.

Joel McCorkel↗

Synchronizing computer clocks using a local area network

Researchers completed the first tests of a method to synchronize the clocks of networked computers to the National Institute of Standards and Technology (NIST) time scale. The method uses a server computer to disseminate the time to other clients on the same local-area network. The server is synchronized to NIST using the ACTS protocol over a dial-up telephone line. The software in both the server and the parameters of this model are used to adjust the time of the local clock and the interval between calibration requests in a statistically optimum way. The algorithm maximizes the time between calibrations while at the same time keeping the time of the local clock correct within a specific tolerance. The method can be extended to synchronize computers linked over wide-area networks, and an experiment to test the performance of the algorithms over such networks is being planned.

Levine, Judah↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System: Preprint

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS↗

Measurements and kinetic modeling of O 2 vibrational kinetics in O 2 –Ar mixtures partially dissociated by a Ns pulse discharge

Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

The TRMM Multi-satellite Precipitation Analysis (TMPA): Quasi-Global Precipitation Estimates at Fine Scales

The TRMM Multi-satellite Precipitation Analysis (TMPA) provides a calibration-based sequential scheme for combining multiple precipitation estimates from satellites, as well as gauge analyses where feasible, at fine scales (0.25 degrees x 0.25 degrees and 3-hourly). It is available both after and in real time, based on calibration by the TRMM Combined Instrument and TRMM Microwave Imager precipitation products, respectively. Only the after-real-time product incorporates gauge data at the present. The data set covers the latitude band 50 degrees N-S for the period 1998 to the delayed present. Early validation results are as follows: The TMPA provides reasonable performance at monthly scales, although it is shown to have precipitation rate dependent low bias due to lack of sensitivity to low precipitation rates in one of the input products (based on AMSU-B). At finer scales the TMPA is successful at approximately reproducing the surface-observation-based histogram of precipitation, as well as reasonably detecting large daily events. The TMPA, however, has lower skill in correctly specifying moderate and light event amounts on short time intervals, in common with other fine-scale estimators. Examples are provided of a flood event and diurnal cycle determination.

Huffman, George J.↗