Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Design and construction of a quantum matter synthesizer

The quantum matter synthesizer (QMS) is a new quantum simulation platform in which individual particles in a lattice can be resolved and re-arranged into arbitrary patterns. The ability to spatially manipulate ultracold atoms and control their tunneling and interactions at the single-particle level allows full control of a many-body quantum system. We present the design and characterization of the QMS, which integrates into a single ultra-stable apparatus a two-dimensional optical lattice, a moving optical tweezer array formed by a digital micromirror device, and site-resolved atomic imaging. We demonstrate excellent mechanical stability between the lattice and tweezer array with relative fluctuations below 10 nm, diffraction-limited imaging at a resolution of 655 nm, and high-speed real-time control of the tweezer array at a 2.52 kHz refresh rate, which will be adopted to realize fast rearrangement of atoms. The QMS also features new technologies and schemes, such as nanotextured anti-reflective windows and all-optical long-distance transport of atoms.

47 OTHER INSTRUMENTATION↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Interfaces in Halide Perovskites: Passivating Defects and Probing Grain Structure

In this talk we describe the role of interfaces, surface defects, and strain on non-radiative recombination losses in hybrid perovskite semiconductors. Using combinations of scanning-probe, electron backscatter diffraction (EBSD), and time-resolved photoluminescence microscopy and spectroscopy, we explore the microscopic origins of non-radiative recombination in both archetypal methylammonium lead tri-iodide (MAPI), and more advanced mixed-cation perovskites. Using EBSD, we image local grain orientation and strain, and correlate surface strain with increased non-radiative recombination in MAPI. We explore the interface between the perovskite and various common charge extraction layers, combining experiment and simulation to show that surface recombination at the charge extraction layers is a limitation in current perovskite solar cell architectures. Finally, we explore alternative passivation and extraction layers to propose ways to more routinely approach the theoretical voltage limits in perovskite photovoltaic using scalable process chemistry.

14 SOLAR ENERGY↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Operando microscopy for neuromorphic hardware

Microscopy techniques can uncover the physical properties and dynamic behaviours of materials, driving the discovery of emergent phenomena and guiding the design of next-generation computing hardware. As artificial intelligence becomes pervasive, the demand for high-performance materials to support sustainable information technologies is growing. Here, this Review highlights state-of-the-art imaging from electron and X-ray to optical techniques to probe the dynamics of neuromorphic materials, including operando characterization of devices. We examine design principles for neuromorphic materials, along with obstacles that hinder their development. Emphasis is placed on spatially and temporally resolved approaches that capture state changes including phase transitions, ferroic switching and spin-wave propagation that emulate biological components such as neurons, synapses and their connectivity. We discuss challenges in operando characterization and the integration of artificial intelligence-driven analysis for feedback-guided material discovery. Finally, we outline opportunities for real-time imaging of neuromorphic systems, paving the way towards adaptive, brain-inspired hardware.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Grand-scale Atmospheric Imaging Apparatus (GAIA) and Wind LiDAR Multi-scale Measurements in the Atmospheric Surface Layer

Understanding the organization and dynamics of turbulence structures in the atmospheric surface layer (ASL) is important for fundamental and applied research in different fields, including weather prediction, snow settling, particle and pollutant transport, and wind energy. The main challenges associated with probing and modeling turbulence in the ASL are: i) the broad range of turbulent scales associated with the different eddies present in high Reynolds-number boundary layers ranging from the viscous scale ($\mathcal{O}$(mm)) up to large energy-containing structures ($\mathcal{O}$(km)); ii) the non-stationarity of the wind conditions and the variability associated with the daily cycle of the atmospheric stability; iii) the interactions among eddies of different sizes populating different layers of the ASL, which contribute to momentum, energy, and scalar turbulent fluxes. Creative and innovative measurement techniques are required to probe near-surface turbulence by generating spatio-temporally-resolved data in the proximity of the ground and, at the same time, covering the entire ASL height with large enough streamwise extent to characterize the dynamics of larger eddies evolving aloft. To this aim, the U.S. National Science Foundation sponsored the development of the Grand-scale Atmospheric Imaging Apparatus (GAIA) enabling super-large snow particle image velocimetry (SLPIV) in the near-surface region of the ASL. This inaugural version of GAIA provides a comprehensive measuring system by coupling SLPIV and two scanning Doppler LiDARs to probe the ASL at an unprecedented resolution. A field campaign performed in 2021–2022 and its preliminary results are presented herein elucidating new research opportunities enabled by the GAIA measuring system.

17 WIND ENERGY↗

Rapid simulations of hyperspectral near-field images of three-dimensional heterogeneous surfaces

The scattering-type scanning near-field optical microscope (s-SNOM) has emerged as a powerful tool for resolving nanoscale inhomogeneities in laterally heterogeneous samples. However, most analytical models used to predict the scattering near-field signals are assuming homogenous landscapes (bulk materials), resulting in inconsistencies when applied to samples with more complex configurations. In this work, we combine the point-dipole model (PDM) to the finite-element method (FEM) to account for the lateral and vertical heterogeneities while keeping the computation time manageable. Full images, spectra, or hyperspectral line profiles can be simulated by calculating the self-consistent dipole radiation demodulated at higher harmonics of the tip oscillation, mimicking real experimental procedures. Using this formalism, we clarify several important yet puzzling experimental observations in near-field images on samples with rich typography and complex material compositions, heterostructures of two-dimensional material flakes, and plasmonic antennas. The developed method serves as a basis for future investigations of nano-systems with nontrivial topography.

36 MATERIALS SCIENCE↗

Exploring Domain-Wall Pinning in Ferroelectrics via Automated High-Throughput Atomic Force Microscopy

Domain-wall dynamics in ferroelectric materials are strongly position-dependent, since each polar interface is locked into a unique local microstructure. This necessitates spatially resolved studies of wall pinning using scanning-probe microscopy techniques. The pinning centers and pre-existing domain walls are usually sparse within the image plane, precluding the use of dense hyperspectral imaging modes and requiring time-consuming human experimentation. Here, a large-area epitaxial PbTiO 3 film on cubic KTaO 3 was investigated to quantify the electric-field-driven dynamics of the polar–strain domain structures using ML-controlled automated piezoresponse force microscopy. Analysis of 1500 switching events reveals that domain-wall displacement depends not only on field parameters but also on the local ferroelectric–ferroelastic configuration. For example, twin boundaries in polydomains regions, like a 1 – /c+ ∥ a 2 – /c – , stay pinned up to a certain level of bias magnitude and change only marginally as the bias increases from 20 to 30 V, whereas single-variant boundaries, like the a 2 + /c + ∥ a 2 – /c – stack, are already activated at 20 V. These statistics on the possible ferroelectric and ferroelastic wall orientations, together with the automated high-throughput AFM workflow, can be distilled into a predictive map that links domain configurations to pulse parameters. Here, this microstructure-specific rule set forms the foundation for the design of ferroelectric memories.

automated scanning probe microscopy↗

Unveiling defect-mediated carrier dynamics in monolayer semiconductors by spatiotemporal microwave imaging

The optoelectronic properties of atomically thin transition-metal dichalcogenides are strongly correlated with the presence of defects in the materials, which are not necessarily detrimental for certain applications. For instance, defects can lead to an enhanced photoconduction, a complicated process involving charge generation and recombination in the time domain and carrier transport in the spatial domain. Here, we report the simultaneous spatial and temporal photoconductivity imaging in two types of WS 2 monolayers by laser-illuminated microwave impedance microscopy. The diffusion length and carrier lifetime were directly extracted from the spatial profile and temporal relaxation of microwave signals, respectively. Time-resolved experiments indicate that the critical process for photoexcited carriers is the escape of holes from trap states, which prolongs the apparent lifetime of mobile electrons in the conduction band. As a result, counterintuitively, the long-lived photoconductivity signal is higher in chemical-vapor deposited (CVD) samples than exfoliated monolayers due to the presence of traps that inhibits recombination. Overall, our work reveals the intrinsic time and length scales of electrical response to photoexcitation in van der Waals materials, which is essential for their applications in optoelectronic devices.

42 ENGINEERING↗

Phase-resolved terahertz nanoimaging of W Te 2 microcrystals

The terahertz (THz) electrodynamics of few-layer W⁢Te 2 is dominated by the plasmon response. However, THz surface plasmons (SPs) with long wavelengths in two-dimensional exfoliated crystals are typically confined by the lateral geometry. Direct visualization of the plasmonic standing wave patterns is challenging due to the spatial confinement and low quality factor of the SP, especially for samples that are only a few monolayers thick. Here, we resolve subtle real-space features of the plasmonic response of W⁢Te 2 by augmenting more common scattering amplitude experiments with the phase contrast accomplished within the time-domain version of THz nanoimaging. Amplitude and phase images allow us to quantitatively evaluate the evolution of the plasmonic response at cryogenic temperatures in samples with variable thickness from 3 to 12 monolayers. Further, the proposed imaging modality is universally applicable to the THz near-field nanoscopy of low-dimensional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient superconductivity at nano- and meso-scales

High-T c superconductivity is surpassed by few, if any, other unsolved problems in contemporary physics in terms of its richness, complexity, impact on other fields, and potential technological importance in energy applications. Recent discoveries reveal that the highest transition temperatures emerge under extraordinary experimental conditions such as the strong perturbation of a single atomic layer material by the underlying substrate, application of ~200 GPa pressure or ~MV/cm static electric fields, or irradiation by intense femtosecond optical fields. Research in superconductivity under extreme experimental conditions is challenging and requires the development of novel experimental methods and new theoretical tools suitable to tackle the problem. Our team has approached the challenges of transient superconductivity under intense optical fields by rethinking the types of experimental observables that are best suited to elucidate the physics of light-induced effects. This exercise has identified the need for: i) ultra-fast spatio-temporal probes enabling access to plasmonic properties and also nano-scale inhomogeneities that are ubiquitous in unconventional superconductors; ii) meso-scale structures and hybrid meta-surfaces imperative for strong enhancement of optical fields and iii) theoretical approaches suitable to explain and predict the response of superconductors under ultra-fast photo-excitation. Co-PIs have already made major advances with developing capabilities i)-iii). Therefore, our team is poised to make significant progress in transient superconductivity by exploring novel spatio-temporal effects that currently remain unattainable. Co-investigators will search for light-induced superconductivity in the high-T c cuprates to build upon spectacular recent results still lacking independent confirmations. Novel data acquisition methods combined with nano-plasmonic imaging will allow our team to test the hypothesis of photo-induced superconducting pairing. Spatio-temporal experiments will provide insights into the interplay between superconductivity and competing orders in the cuprates. Co-PIs will also investigate strong light-matter interaction and superconductivity in FeSe monolayers. Finally, we will study spatio-temporal electrodynamics of planar Josephson junctions. This latter direction will allow our team to thoroughly characterize one of the most fundamental examples of inhomogeneity in all of unconventional superconductivity. The proposed experiments in combination with theoretical analysis will provide information that is difficult to obtain using alternative methods. Basov and Averitt will carry out pump-probe spectroscopy and nano-imaging experiments. Averitt and Hone will design and fabricate state-of-the-art meta-surfaces. Theoretical and computational studies of ultrafast transient phenomena will be carried out by Millis and Fogler. Modeling of time-resolved nano-optical effects will be done by Fogler. The bulk of the requested budget will be used to support graduate students at Columbia & UCSD that will be co-supervised by co-PIs. The proposed program is transformative, since it will enable an entire suite of experiments previously either impossible or technically implausible. It will deliver critically important insights not only into mechanisms of unconventional superconductivity but also to many other correlated quantum materials.

36 MATERIALS SCIENCE↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural and Chemical Evolution of an Inverse CeO x /Cu Catalyst under CO 2 Hydrogenation: Tunning Oxide Morphology to Improve Activity and Selectivity

Small nanoparticles of ceria deposited on a powder of CuO display a very high selectivity for the production of methanol via CO 2 hydrogenation. CeO 2 /CuO catalysts with ceria loadings of 5%, 20%, and 50% were investigated. Among these, the system with 5% CeO x showed the best catalytic performance at temperatures between 200 and 350 °C. The evolution of this system under reaction conditions was studied using a combination of environmental transmission electron microscopy (E-TEM), in situ X-ray absorption spectroscopy (XAS), and time-resolved X-ray diffraction (TR-XRD). For 5% CeO x /Cu, the in situ studies pointed to a full conversion of CuO into metallic copper, with a complete transformation of Ce 4+ into Ce 3+ . Images from E-TEM showed drastic changes in the morphology of the catalyst when it was exposed to H 2 , CO 2 , and CO 2 /H 2 mixtures. Under a CO 2 /H 2 feed, there was a redispersion of the ceria particles that was detected by E-TEM and in situ TR-XRD. Finally, these morphological changes were made possible by the inverse oxide/metal configuration and facilitate the binding and selective conversion of CO 2 to methanol.

03 NATURAL GAS↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Dark Lock-in Thermography Identifies Solder Bond Failure as the Root Cause of Series Resistance Increase in Fielded Solar Modules

Correlating the electrical performance of photovoltaic modules to the spatially resolved photoluminescence, electroluminescence, and dark lock-in thermography (DLIT) images is an important long-term goal for developing solar cell technology. These images offer highly sophisticated and detailed information about the spatial distribution and (if imaged at successive time intervals) temporal degradation of local series and shunt resistances. There have been extensive studies to correlate these imaging techniques to local characteristics at the cell level. However, it has been difficult to extract and quantify module-level information from the techniques. In this study, we interpret module current-voltage (I-V) measurements along with corresponding DLIT images within a module-scale simulation framework, demonstrating that series resistance degradation of the module I-V characteristics, in this case, can be attributed to solder bond failures. Our simulations highlight how current crowding associated with a failed solder joint (or a section of the solder pad) translates to the characteristic point-like (asymmetric doublet) heating pattern in neighboring solder joints (or the neighboring regions of the solder pad). Overall, the correlation between series resistance and solder joint degradation could inform expedited diagnosis of field degradation of solar modules.

42 ENGINEERING↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Facile hyperpolarization chemistry for molecular imaging and metabolic tracking of [1– 13 C]pyruvate in vivo

Hyperpolarization chemistry based on reversible exchange of parahydrogen, also known as Signal Amplification By Reversible Exchange (SABRE), is a particularly simple approach to attain high levels of nuclear spin hyperpolarization, which can enhance NMR and MRI signals by many orders of magnitude. SABRE has received significant attention in the scientific community since its inception because of its relative experimental simplicity and its broad applicability to a wide range of molecules, however, in vivo detection of molecular probes hyperpolarized by SABRE has remained elusive. Here we describe a first demonstration of SABRE-hyperpolarized contrast detected in vivo, specifically using hyperpolarized [1– 13 C]pyruvate. Biocompatible formulations of hyperpolarized [1– 13 C]pyruvate in, both, methanol-water, and ethanol-water mixtures followed by dilution with saline and catalyst filtration were prepared and injected into healthy Sprague Dawley and Wistar rats. Effective hyperpolarization-catalyst removal was performed with silica filters without major losses in hyperpolarization. Metabolic conversion of pyruvate to lactate, alanine, and bicarbonate was detected in vivo. Pyruvate-hydrate was also observed as a minor byproduct. Measurements were performed on the liver and kidney at 4.7 T via time-resolved spectroscopy and chemical-shift-resolved MRI. In addition, whole-body metabolic measurements were obtained using a cryogen-free 1.5 T MRI system, illustrating the utility of combining lower-cost MRI systems with simple, low-cost hyperpolarization chemistry to develop safe and scalable molecular imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗