A BAPTA employing rotary transformers, stepper motors and ceramic ball bearings
The utilization of rotary transformers as an alternative to slip rings for the power transfer from solar panels to a satellite's main body could be advantageous, especially if an ac bus system is taken into consideration. Different approaches with main emphasis on the electromagnetic design were investigated and showed efficiencies of up to 99% with a 3 kW power capability. A solidly preloaded pair of ball bearings with ceramic balls assures proper transformer air gaps and acceptable torque changes over temperature and temperature gradients. The bearing and power transfer assembly is driven by a direct drive stepper motor with inherent redundancy properties and needs no caging mechanism.