Search NASA⌕ Search

SEARCH · Search NASA

Results for “Uncertainty visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Status of the NEAMS and ARC neutronic fast reactor tools integration to the NEAMS Workbench

The Workbench initiative was launched in FY-2017 within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Integration Product Line to facilitate the transition from conventional tools to high-fidelity tools. The Workbench provides a common user interface for model creation, real-time validation, execution, output processing, and visualization for integrated codes. The integration of the Argonne Reactor Computation (ARC) suite of codes into the NEAMS Workbench was initiated in FY-2017. The ARC codes contain both legacy codes like DIF3D and REBUS-3 that were developed with over 30 years of experience, and newer NEAMS additions like MC2-3, PERSENT and PROTEUS. The ARC integration into the NEAMS Workbench interface relies on the PyARC module which handles the pre- and post-processing of the native ARC codes input, and the runtime environment. The PyARC module together with the NEAMS Workbench interface are both released under Open Source Software licenses. In FY-2019, the effort focused on integrating the explicit assembly management logic of REBUS, the GAMSOR code for gamma heating transport, and of the NODAL solver of PROTEUS. Additional capabilities were also integrated in response to user requests, such as the assembly power peaking calculation and a 2D result plotting capability. For verification and demonstration purposes, the ARC codes were used through the Workbench for solving the Sodium-cooled Fast Reactor Uncertainty Analysis in Modelling (SFR-UAM) benchmark problems, including the newly proposed unit cells and ASTRID problem. Significant effort in FY-2019 focused on training new users from ANL, INL, NCSU, and Westinghouse. In particular, extensive training material was developed in the form of tutorials, including documentation, sample inputs, and associated presentations. The ARC codes are now actively used through the NEAMS Workbench by nuclear engineers at ANL, INL, NCSU, and Westinghouse, for LFR, MSR, micro-reactor, and SFR core design analyses. Future efforts will focus on adding new and existing modeling capabilities available with the ARC and NEAMS codes, training new users and supporting them to continue building user experience.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Clinical Evaluation of Soft Tissue Organ Boundary Visualization on Cone-Beam Computed Tomographic Imaging

Purpose: Cone-beam computed tomographic images (CBCTs) are increasingly used for setup correction, soft tissue targeting, and image-guided adaptive radiotherapy. However, CBCT image quality is limited by low contrast and imaging artifacts. This analysis investigates the detectability of soft tissue boundaries in CBCT by performing a multiple-observer segmentation study. Methods and Materials: In four prostate cancer patients prostate, bladder and rectum were repeatedly delineated by five observers on CBCTs and fan-beam CTs (FBCTs). A volumetric analysis of contouring variations was performed by calculating coefficients of variation (COV: standard deviation/average volume). The topographical distribution of contouring variations was analyzed using an average surface mesh-based method. Results: Observer- and patient-averaged COVs for FBCT/CBCT were 0.09/0.19 for prostate, 0.05/0.08 for bladder, and 0.09/0.08 for rectum. Contouring variations on FBCT were significantly smaller than on CBCT for prostate (p < 0.03) and bladder (p < 0.04), but not for rectum (p < 0.37; intermodality differences). Intraobserver variations from repeated contouring of the same image set were not significant for either FBCT or CBCT (p < 0.05). Average standard deviations of individual observers' contour differences from average surface meshes on FBCT vs. CBCT were 1.5 vs. 2.1 mm for prostate, 0.7 vs. 1.4 mm for bladder, and 1.3 vs. 1.5 mm for rectum. The topographical distribution of contouring variations was similar for FBCT and CBCT. Conclusion: Contouring variations were larger on CBCT than FBCT, except for rectum. Given the well-documented uncertainty in soft tissue contouring in the pelvis, improvement of CBCT image quality and establishment of well-defined soft tissue identification rules are desirable for image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An open source analysis framework for large-scale building energy modeling

Full integration of building energy modelling into the design and retrofit process has long been a goal of building scientists and practitioners. However, significant barriers still exist. Among them are the lack of available: (1) configurable technology stacks for performing both small- and large-scale analyses, (2) different classes of algorithms compatible with common design workflows, and (3) analysis tools for effectively visualizing large-scale simulation results. This article discusses the OpenStudio® Analysis Framework: a scalable analysis framework for building energy modelling that was developed to overcome the three barriers listed above. The framework is open-source and scalable to facilitate wider adoption and has a clearly defined application programming interface upon which other applications can be built. It runs on high-performance computing systems, within cloud infrastructure, and on laptops, and uses a common workflow to enable different classes of algorithms. Lessons learned from previous development efforts are also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of a Neutrino-Induced Charged Current Single Neutral Pion Cross Section at MicroBooNE

Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) operating in the Booster Neutrino Beamline at Fermi National Accelerator Laboratory. MicroBooNE's physics goals include studying short basline $\nu$ oscillation and performing a suite of low energy $\nu$ cross section measurements. Of particular interest to MicroBooNE, and the broader LArTPC community, are electromagnetic showers; these showers are at the heart of searches for charged current $\nu_e$ interactions, including MicroBooNE's flagship search for a MiniBooNE-like low energy excess (LEE). Neutral current $\pi^0$'s, which decay into 2 electromagnetic showers ($\gamma$'s), are the dominant source of non-$\nu_e$ backgrounds in searches for $\nu_{\mu}\rightarrow\nu_e$ oscillations in LArTPCs, such as the LEE. While precise measurements of this neutral current channel will provide a tight constraint on our modeling uncertainties, such events are particularly difficult to iden tify in data with our current tools, as there is often little or no activity at the neutrino interaction point. Charged current interactions, on the other hand, have simpler topologies with a long $\mu$ track that anchors to the interaction vertex. With a vertex in hand, we can develop automated reconstruction tools for neutrino-induced shower topologies (like the $\gamma$'s from $\pi^0$ decay). Thus, in studying charged current $\pi^0$ interactions, we are developing tools that can potentially be used to reconstruct an important LEE background, while also studying the physics of neutrino interactions, of which data is sparse for argon. This thesis reports the world's first measurement of the absolute, flux-averaged cross section of $\nu_{\mu}$-charged current single $\pi^0$ production on argon. The analysis chain begins with the selection of inclusive $\nu_\mu$ charged current events, where a candidate $\mu$ and neutrino interaction vertex are identified. These events are t hen passed to a reconstruction framework where electromagnet! ic shower candidates are reconstructed using computer visualization tools. Finally, the cross section is calculated on two reconstructed topologies: those with at least two reconstructed showers and those with at least one. Additionally, this work describes the first fully-automated electromagnetic shower reconstruction process employed by a LArTPC to perform a cross section analysis. We measure the flux averaged cross section on argon at 824 MeV via the two and one shower selections respectively to be \par \noindent $\sigma_{\geq2 Shower}$ = (2.56 $\pm$ $0.50_{stat}$ $\pm$ $0.31_{genie}$ $\pm$ $0.37_{flux}$ $\pm$ $0.31_{det}$) $\times$ $10^{-38}$ $\frac{cm^2}{Ar}$, \par \noindent $\sigma_{\geq 1 Shower}$ = (2.64 $\pm$ $0.33_{stat}$ $\pm$ $0.36_{genie}$ $\pm$ $0.38_{flux}$ $\pm$ $0.35_{det}$) $\times$ $10^{-38}$ $\frac{cm^2}{Ar}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Environmental Baseline Survey Report for the Title Transfer of the K-792 Switchyard Complex at the East Tennessee Technology Park, Oak Ridge, Tennessee

This environmental baseline survey (EBS) documents the baseline environmental conditions of the U. S. Department of Energy's (DOE's) K-792 Switchyard Complex, which includes the former K-792 Switchyard, the K-79 1-B building, the K-796-A building, and the K-792 Northern Expansion Area located in the northwestern portion of the East Tennessee Technology Park (ETTP). The total area of the property is approximately 19.91 acres. DOE is proposing to transfer the title of this land area and buildings to the Heritage Center, LLC (Heritage Center), a subsidiary corporation of the Community Reuse Organization of East Tennessee (CROET). This report provides supporting information for the transfer of this government-owned facility at ETTP to a non-federal entity. The area proposed for title transfer includes the former K-792 Switchyard, the K-792 Northern Expansion Area, Bldg. K-791-B, Bldg. K-796-A, and the underlying property known as the underlying fee. Located within the K-792 Switchyard footprint but not included in the transfer are Bldg. K-131 0-MP and Bldg. K- 131 0-MQ, two buildings owned by a private company that leases space in the northern portion of the Switchyard. The transfer footprint is bounded by Perimeter Road to the north and west, the parking area for Portal 8 to the south, and primarily the former K-792 Powerhouse Complex and Avenue 'U' North to the east; however, the eastern boundary along the Northern Expansion area has no physical features associated with it. Zone 2 remedial action objectives were developed by the DVS to support the future use of ETTP as a mixed-use commercial and industrial park. Therefore, remediation criteria were designed for the protection of the future industrial worker under the assumption the worker normally would not have the potential for exposure to soils at depths below 10 ft below ground surface (bgs). Accordingly, land use controls (LUCs) have been established to restrict disturbance of soils below 10 ft deep and to limit future land use to industriallcornmercial activities. Where the need for LUCs below 10 ft bgs is not warranted, this is so stated and explained. Once all actions associated with the DVS for Zone 1 and Zone 2 are completed and the data support it, there will be a re-evaluation with EPA and TDEC for the restriction on excavation below 10 ft. The DVS process and the preparation of this report included visual and physical inspections of the property and adjacent properties, a detailed records search, sampling and analysis of soils, radiological walkover surveys, and a risk evaluation. Resources evaluated as part of the records search included Federal Government records, title documents, aerial photographs that may reflect prior uses, and interviews with current and former employees 1 involved in the operations on the real property to identify any areas on the property where hazardous substances and petroleum products, or their derivatives, and acutely hazardous wastes were stored for one year or more, known to have been released, or disposed of. In addition, radiological surveys of Bldgs. K-791-B and K-796-A were conducted to assess the buildings radiological condition. Soil vapor sampling and polychlorinated biphenyl (PCB) swipe sampling also were conducted within the buildings. Based on the U. S. Department of Energy's (DOE's) review of the existing information, including discussions and interviews referenced herein, and evaluation of the data gathered in preparation of the environmental baseline survey (EBS) for the K-792 Switchyard Complex, DOE recommends the following: Due to the uncertainty associated with the nature of the on-site groundwater and the need to evaluate and possibly address groundwater in the future, DOE recommends that the transfer of the K-792 Switchyard Complex be achieved by a covenant deferral per the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) Sect. 120(h)(3)(c). Land use restrictions associated with the covenant deferral are described.

54 ENVIRONMENTAL SCIENCES↗

Economic Consequence Analysis of Disasters: The ECAT Software Tool

This study develops a methodology for rapidly obtaining approximate estimates of the economic consequences from numerous natural, man-made and technological threats. This software tool is intended for use by various decision makers and analysts to obtain estimates rapidly. It is programmed in Excel and Visual Basic for Applications (VBA) to facilitate its use. This tool is called E-CAT (Economic Consequence Analysis Tool) and accounts for the cumulative direct and indirect impacts (including resilience and behavioral factors that significantly affect base estimates) on the U.S. economy. E-CAT is intended to be a major step toward advancing the current state of economic consequence analysis (ECA) and also contributing to and developing interest in further research into complex but rapid turnaround approaches. The essence of the methodology involves running numerous simulations in a computable general equilibrium (CGE) model for each threat, yielding synthetic data for the estimation of a single regression equation based on the identification of key explanatory variables (threat characteristics and background conditions). This transforms the results of a complex model, which is beyond the reach of most users, into a "reduced form" model that is readily comprehensible. Functionality has been built into E-CAT so that its users can switch various consequence categories on and off in order to create customized profiles of economic consequences of numerous risk events. E-CAT incorporates uncertainty on both the input and output side in the course of the analysis.

Environmental Economics↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗

The Sirius System and Its Astrophysical Puzzles: Hubble Space Telescope and Ground-based Astrometry

Sirius, the seventh-nearest stellar system, is a visual binary containing the metallic-line A1 V star Sirius A, the brightest star in the sky, orbited in a 50.13 year period by Sirius B, the brightest and nearest white dwarf (WD). Using images obtained over nearly two decades with the Hubble Space Telescope (HST), along with photographic observations covering almost 20 years and nearly 2300 historical measurements dating back to the 19th century, we determine precise orbital elements for the visual binary. Combined with the parallax and the motion of the A component, these elements yield dynamical masses of 2.063±0.023 M{sub ⊙} and 1.018±0.011 M{sub ⊙} for Sirius A and B, respectively. Our precise HST astrometry rules out third bodies orbiting either star in the system, down to masses of ∼15–25 M{sub Jup}. The location of Sirius B in the Hertzsprung–Russell diagram is in excellent agreement with theoretical cooling tracks for WDs of its dynamical mass, and implies a cooling age of ∼126 Myr. The position of Sirius B on the mass–radius plane is also consistent with WD theory, assuming a carbon–oxygen core. Including the pre-WD evolutionary timescale of the assumed progenitor, the total age of Sirius B is about 228 ± 10 Myr. We calculated evolutionary tracks for stars with the dynamical mass of Sirius A, using two independent codes. We find it necessary to assume a slightly subsolar metallicity, of about 0.85 Z{sub ⊙}, to fit its location on the luminosity–radius plane. The age of Sirius A based on these models is about 237–247 Myr, with uncertainties of ±15 Myr, consistent with that of the WD companion. We discuss astrophysical puzzles presented by the Sirius system, including the probability that the two stars must have interacted in the past, even though there is no direct evidence for this and the orbital eccentricity remains high.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Learning for Immersive Engagement in Energy Simulations

The fast computation which is critical for immersive engagement with and learning from energy simulations would be furthered by developing a general method for creating rapidly computed simplified versions of NREL's computation-intensive energy simulations. Created using machine learning techniques, these 'reduced form' simulations can provide statistically sound estimates of the results of the full simulations at a fraction of the computational cost with response times - typically less than one minute of wall-clock time - suitable for real-time human-in-the-loop design and analysis. Additionally, uncertainty quantification techniques can document the accuracy of the approximate models and their domain of validity. Approximation methods are applicable to a wide range of computational models, including supply-chain models, electric power grid simulations, and building models. These reduced-form representations cannot replace or re-implement existing simulations, but instead supplement them by enabling rapid scenario design and quality assurance for large sets of simulations. We present an overview of the framework and methods we have implemented for developing these reduced-form representations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

60 APPLIED LIFE SCIENCES↗

Subsidence Measurements at the Teller 27 Field Site, Seward Peninsula, Alaska, 2021

In September 2021, differential GPS (dGPS) points were collected in areas of visual subsidence in the Teller watershed near mile marker 27 of the Bob Blodgett Nome-Teller Memorial Highway on the Seward Peninsula of Alaska. This study aimed to understand how structural permafrost loss is affecting meter-scale ground elevation. As ice thaws, heaving and slumping of the landscape creates new microtopographical features on the landscape that may alter surface hydrology and soil moisture and thus plant community composition and biogeochemical cycling. The Teller 27 field site is underlain with discontinuous permafrost, so the landscape features a variety of permafrost features. We collected ground elevations from eight subsidence areas in two forms: 1) Transects were sampled laterally through areas of ground subsidence to capture the high edges and low spots where the earth slumped. 2) The circumference of the subsidence area was sampled in order to measure the ground area affected by subsidence. These data were collected with an Emlid Reach RS2 dGPS and a base station. This dataset includes one *.csv of dGPS locations of the eight subsidence locations and one *.kml of measurement locations.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic) was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Overview of the Tolerance Limit Calculations with Application to TSURFER

To establish confidence in the results of computerized physics models, a key regulatory requirement is to develop a scientifically defendable process. The methods employed for confidence, characterization, and consolidation, or C3, are statistically involved and are often accessible only to avid statisticians. This manuscript serves as a pedagogical presentation of the C3 process to all stakeholders—including researchers, industrial practitioners, and regulators—to impart an intuitive understanding of the key concepts and mathematical methods entailed by C3. The primary focus is on calculation of tolerance limits, which is the overall goal of the C3 process. Tolerance limits encode the confidence in the calculation results as communicated to the regulator. Understanding the C3 process is especially critical today, as the nuclear industry is considering more innovative ways to assess new technologies, including new reactor and fuel concepts, via an integrated approach that optimally combines modeling and simulation and minimal targeted validation experiments. This manuscript employs intuitive, analytical, numerical, and visual representations to explain how tolerance limits may be calculated for a wide range of configurations, and it also describes how their values may be interpreted. Various verification tests have been developed to test the calculated tolerance limits and to help delineate their values. The manuscript demonstrates the calculation of tolerance limits for TSURFER, a computer code developed by the Oak Ridge National Laboratory for criticality safety applications. The goal is to evaluate the tolerance limit for TSURFER-determined criticality biases to support the determination of upper, subcritical limits for regulatory purposes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HydroForecast Long-term: Improving hydropower’s resilience to climate change through accurate climate-scale

With hydrologic patterns and water availability across the globe shifting due to climate change, advancements in hydrologic prediction systems can help significantly reduce the uncertainties that utilities and water supply entities have in their decision making. Understanding and estimating hydrology at the climate scale is critical for managing water resources under changing climate scenarios. This project focuses on integrating state-of-the-art neural network modeling with downscaled climate projections to deliver the reliable water supply projections decades into the future to meet an urgent need from hydropower operators and water utilities. In this Phase 1 DOE SBIR proposal, we developed and validated a theory-guided neural network model, HydroForecast Long-term, for climate-scale hydrology and implemented the model within existing HydroForecast infrastructure. HydroForecast Long-term combines the most accurate streamflow modeling system with a flexible and scalable data architecture to generate water supply projections out to the year 2100. This report illustrates that we have achieved our four objectives: 1) create a prototype of HydroForecast Long-term, building the neural network prediction model, 2) build an automated data input pipeline that processes large amounts of data from the latest global temperature and precipitation climate models; 3) benchmark the accuracy of the hydrologic model over the recent two decades over a large set of diverse basins, and 4) create a set of output visuals and summary metrics informed by customer feedback that connect the data to critical decision points. This work empowers water users to make data-informed decisions supporting a resilient, renewable-powered grid and water system. The results advance the Department of Energy’s mission by addressing critical gaps in water supply planning under climate change.

13 HYDRO ENERGY↗

Pre-Transient Characterization of Historic EBR-II Pins for Transient Testing

Current interest in sodium-cooled fast reactor (SFR) designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced reactor fuel technology development. Modern U-Zr and U- Pu-Zr pin designs are primary candidates to fuel SFRs and boast high fuel utilization capacity, increased fuel-cladding compatibility, and improved safety through inherent feedback mechanisms. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under transient overpower (TOP) and loss of flow (LOF) scenarios. Throughout historical testing within the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF), fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds to inform operational limitations rely heavily on fuel composition, burnup, and irradiation history. In expanding TOP and LOF testing, the Transient Heat sink Overpower Response (THOR) Capsule will be used to test modern fuel technologies in a static sodium environment in the Transient Reactor Test (TREAT) Facility. The THOR capsule is highly instrumented and will provide time-dependent thermal behavior of SFR fuel pins subjected to accident conditions within TREAT. The THOR-Metallic (THOR- M) campaign aims to validate and expand historical TOP and LOF testing on high burnup U-Zr and U-Pu- Zr fuel alloys previously irradiated in EBR-II by running the rods to failure. This contribution focuses primarily on the pre-transient engineering-scale destructive and non- destructive characterization that has been conducted on both the test and sibling pins used for the TOP and LOF tests. All pins underwent visual examination, neutron radiography, element contact profilometry, and precise gamma scan. The sibling pins used for each test were further analyzed using gas assay, sampling, and recharge analysis (GASR), and optical microscopy. The results from each technique confirmed that the fuel pins were intact and devoid of any atypical developments when compared to historical data. Additionally, the analyzed measurements establish a baseline for comparison to post-transient analysis. Key fuel behaviors quanitifed include axial elongation of the fuel column, diametral strain of the pin, patterns in fluff structure geometry, changes in axial isotope distribution, evolution of constituent redistribution, porosity, and fission gas release. The pre-transient measurements and changes attributed to transient behavior from post-transient measurement will be compared to historical data to capture the behavioral dependence on composition, burnup, and irradiation history. Results from this work advance the initiatives of the THOR-M campaign, which aid in informing fuel performance models and establishing safety criteria for SFR operational limits. The novel combination of test environment, in-situ instrumentation, and comprehensive suite of characterization methods provides greater understanding of transient fuel behavior. Overall, information on the time and condition of pin failure for high burnup U-Pu-Zr will greatly expand the limited existing TOP and LOF test data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-Transient Characterization of Historic EBR-II Pins for Transient Testing

Current interest in sodium-cooled fast reactor (SFR) designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced reactor fuel technology development. Modern U-Zr and U- Pu-Zr pin designs are primary candidates to fuel SFRs and boast high fuel utilization capacity, increased fuel-cladding compatibility, and improved safety through inherent feedback mechanisms. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under transient overpower (TOP) and loss of flow (LOF) scenarios. Throughout historical testing within the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF), fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds to inform operational limitations rely heavily on fuel composition, burnup, and irradiation history. In expanding TOP and LOF testing, the Transient Heat sink Overpower Response (THOR) Capsule will be used to test modern fuel technologies in a static sodium environment in the Transient Reactor Test (TREAT) Facility. The THOR capsule is highly instrumented and will provide time-dependent thermal behavior of SFR fuel pins subjected to accident conditions within TREAT. The THOR-Metallic (THOR- M) campaign aims to validate and expand historical TOP and LOF testing on high burnup U-Zr and U-Pu- Zr fuel alloys previously irradiated in EBR-II by running the rods to failure. This contribution focuses primarily on the pre-transient engineering-scale destructive and non- destructive characterization that has been conducted on both the test and sibling pins used for the TOP and LOF tests. All pins underwent visual examination, neutron radiography, element contact profilometry, and precise gamma scan. The sibling pins used for each test were further analyzed using gas assay, sampling, and recharge analysis (GASR), and optical microscopy. The results from each technique confirmed that the fuel pins were intact and devoid of any atypical developments when compared to historical data. Additionally, the analyzed measurements establish a baseline for comparison to post-transient analysis. Key fuel behaviors quanitifed include axial elongation of the fuel column, diametral strain of the pin, patterns in fluff structure geometry, changes in axial isotope distribution, evolution of constituent redistribution, porosity, and fission gas release. The pre-transient measurements and changes attributed to transient behavior from post-transient measurement will be compared to historical data to capture the behavioral dependence on composition, burnup, and irradiation history. Results from this work advance the initiatives of the THOR-M campaign, which aid in informing fuel performance models and establishing safety criteria for SFR operational limits. The novel combination of test environment, in-situ instrumentation, and comprehensive suite of characterization methods provides greater understanding of transient fuel behavior. Overall, information on the time and condition of pin failure for high burnup U-Pu-Zr will greatly expand the limited existing TOP and LOF test data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-109: Evaluation of Deformable Accumulated Parotid Doses Using Different Registration Algorithms in Adaptive Head and Neck Radiotherapy

Purpose: Three deformable image registration (DIR) algorithms are utilized to perform deformable dose accumulation for head and neck tomotherapy treatment, and the differences of the accumulated doses are evaluated. Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions.Three DIR methods (B-spline, Diffeomorphic Demons and MIMvista) were used to propagate parotid structures from planning CTs to the daily CTs and accumulate fractionated dose on the planning CTs. The mean accumulated doses of parotids were quantitatively compared and the uncertainties of the propagated parotid contours were evaluated using Dice similarity index (DSI). Results: The planned mean dose of the ipsilateral parotids (32.42±3.13Gy) was slightly higher than those of the contralateral parotids (31.38±3.19Gy)in 10 patients. The difference between the accumulated mean doses of the ipsilateral parotids in the B-spline, Demons and MIMvista deformation algorithms (36.40±5.78Gy, 34.08±6.72Gy and 33.72±2.63Gy ) were statistically significant (B-spline vs Demons, P<0.0001, B-spline vs MIMvista, p =0.002). And The difference between those of the contralateral parotids in the B-spline, Demons and MIMvista deformation algorithms (34.08±4.82Gy, 32.42±4.80Gy and 33.92±4.65Gy ) were also significant (B-spline vs Demons, p =0.009, B-spline vs MIMvista, p =0.074). For the DSI analysis, the scores of B-spline, Demons and MIMvista DIRs were 0.90, 0.89 and 0.76. Conclusion: Shrinkage of parotid volumes results in the dose increase to the parotid glands in adaptive head and neck radiotherapy. The accumulated doses of parotids show significant difference using the different DIR algorithms between kVCT and MVCT. Therefore, the volume-based criterion (i.e. DSI) as a quantitative evaluation of registration accuracy is essential besides the visual assessment by the treating physician. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225)

60 APPLIED LIFE SCIENCES↗

The role of acceptable knowledge in transuranic waste disposal operations - 11117

The Acceptable Knowledge (AK) process plays a key role in the delineation of waste streams destined for the Waste Isolation Pilot Plant (WIPP). General Electric's Vallecitos Nuclear Center (GEVNC) provides for an ideal case study of the application of AK in a multiple steward environment. In this review we will elucidate the pivotal role Acceptable Knowledge played in segregating Department of Energy (DOE) responsibilities from a commercial facility. The Acceptable Knowledge process is a necessary component of waste characterization that determines whether or not a waste stream may be considered for disposal at the WIPP site. This process may be thought of as an effort to gain a thorough understanding of the waste origin, chemical content, and physical form gleaned by the collection of documentation that concerns generator/storage site history, mission, and operations; in addition to waste stream specific information which includes the waste generation process, the waste matrix, the quantity of waste concerned, and the radiological and chemical make up of the waste. The collection and dissemination of relevant documentation is the fundamental requirement for the AK process to work. Acceptable Knowledge is the predominant process of characterization and, therefore, a crucial part of WIPP's transuranic waste characterization program. This characterization process, when conducted to the standards set forth in WIPP's operating permit, requires confirmation/verification by physical techniques such as Non-Destructive Examination (NDE), Visual Examination (VE), and Non-Destructive Assay (NDA). These physical characterization techniques may vary in their appropriateness for a given waste stream; however, nothing will allow the substitution or exclusion of AK. Beyond the normal scope of operations, AK may be considered, when appropriate, a surrogate for the physical characterization techniques in a procedure that appeals to concepts such As Low As Reasonably Achievable (ALARA) and budgetary savings. This substitution is referred to as an Acceptable Knowledge Sufficiency Determination. With a Sufficiency Determination Request, AK may supplant the need for one or all of the physical analysis methods. This powerful procedure may be used on a scale as small as a single container to that of a vast waste stream. Only under the most stringent requirements will an AK Sufficiency Determination be approved by the regulators and, to date, only six such Sufficiency Determinations have been approved. Although Acceptable Knowledge is legislated into the operational procedures of the WIPP facility there is more to it than compliance. AK is not merely one of a long list of requirements in the characterization and verification of transuranic (TRU) waste destined for the WIPP. Acceptable Knowledge goes beyond the regulatory threshold by offering a way to reduce risk, cost, time, and uncertainty on its own laurels. Therefore, AK alone can be argued superior to any other waste characterization technique.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗