Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials

Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volume histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We have validated the dosimetric accuracy of a commercial MRgIMRT system using high-resolution 3D techniques. We have demonstrated for the first time that hybrid 3D remote dosimetry is a comprehensive and feasible approach to commissioning MRgIMRT. This may provide better sensitivity in error detection compared with standard 2-dimensional measurements and could be used when implementing complex new magnetic resonance guided radiation therapy technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of numerical models for seismic fluid-structure-interaction analysis of nuclear, safety-related equipment

Seismic design, qualification, and risk assessment of nuclear safety-related vessels filled with liquid will have to consider the interaction between the vessel (tank), the contained liquid, and submerged components, if any. Seismic fluid-structure-interaction (FSI) analysis of nuclear vessels will rely on numerical models, which are required to be verified and validated. This study validates previously-verified numerical models using test data generated from earthquake-simulator experiments involving a cylindrical tank. Two solvers in LS-DYNA for FSI simulations are used for the numerical analysis: Arbitrary-Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD). Numerical and test results are compared for responses critical to seismic design of advanced reactor vessels: hydrodynamic pressures on the tank wall, reactions at the support, and wave heights of the contained liquid. Analysis is performed for one-, two-, and three-directional seismic inputs with a range of intensity, and rocking motions. The accuracy of the numerical results and different methods for outputting wave heights are discussed. Recommendations for validation of seismic FSI numerical models of advanced reactors are provided. As a result, the validation exercise presented in this study is broadly applicable to cylindrical tanks, regardless of industry sector.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A framework for feasibility-level validation of high-resolution wave hindcast models

The value of long-term wave hindcasts for investigating wave climates, wave energy resources, and extreme wave conditions has motivated research developing, calibrating and validating wave hindcast models. Past hindcast model validation studies examined the accuracy in modeling bulk wave parameters of overall sea states without considering the dependency of the model's skill within different sea states. In the present study, a framework for wave hindcast model validation is developed by examining the model accuracy for the most frequently occurring sea states, sea states contributing the most energy to total wave power, sea states associated with hurricane events, and those with the largest model error. Here, validations using bulk wave parameters and frequency-directional spectra at these key sea states and extreme wave conditions based on univariate and bivariate-contour methods provide insights to improve model accuracy, identifying the model's strong and weak points, and pathways for improvement, e.g., modeling wave-current interactions and adjusting wind data. This study adds to a growing body of research demonstrating that a carefully calibrated and verified spectral wave hindcast model can be used to estimate key wave energy parameters over a wide range of wave energy climates, as well as their spatial, temporal, frequency, directional, and probabilistic distributions.

54 ENVIRONMENTAL SCIENCES↗

Characterization and validation of an in silico toxicology model to predict the mutagenic potential of drug impurities*

Control and minimization of human exposure to potential genotoxic impurities found in drug substances and products is an important part of preclinical safety assessments of new drug products. The FDA's 2008 draft guidance on genotoxic and carcinogenic impurities in drug substances and products allows use of computational quantitative structure–activity relationships (QSAR) to identify structural alerts for known and expected impurities present at levels below qualified thresholds. This study provides the information necessary to establish the practical use of a new in silico toxicology model for predicting Salmonella t. mutagenicity (Ames assay outcome) of drug impurities and other chemicals. We describe the model's chemical content and toxicity fingerprint in terms of compound space, molecular and structural toxicophores, and have rigorously tested its predictive power using both cross-validation and external validation experiments, as well as case studies. Consistent with desired regulatory use, the model performs with high sensitivity (81%) and high negative predictivity (81%) based on external validation with 2368 compounds foreign to the model and having known mutagenicity. A database of drug impurities was created from proprietary FDA submissions and the public literature which found significant overlap between the structural features of drug impurities and training set chemicals in the QSAR model. Overall, the model's predictive performance was found to be acceptable for screening drug impurities for Salmonella mutagenicity. -- Highlights: ► We characterize a new in silico model to predict mutagenicity of drug impurities. ► The model predicts Salmonella mutagenicity and will be useful for safety assessment. ► We examine toxicity fingerprints and toxicophores of this Ames assay model. ► We compare these attributes to those found in drug impurities known to FDA/CDER. ► We validate the model and find it has a desired predictive performance.

60 APPLIED LIFE SCIENCES↗

A practical method to test the validity of the standard Gumbel distribution in logit-based multinomial choice models of travel behavior

Most multinomial choice models (e.g., the multinomial logit model) adopted in practice assume an extreme-value Gumbel distribution for the random components (error terms) of utility functions. This distributional assumption offers a closed-form likelihood expression when the utility maximization principle is applied to model choice behaviors. As a result, model coefficients can be easily estimated using the standard maximum likelihood estimation method. However, maximum likelihood estimators are consistent and efficient only if distributional assumptions on the random error terms are valid. It is therefore critical to test the validity of underlying distributional assumptions on the error terms that form the basis of parameter estimation and policy evaluation. In this paper, a practical yet statistically rigorous method is proposed to test the validity of the distributional assumption on the random components of utility functions in both the multinomial logit (MNL) model and multiple discrete-continuous extreme value (MDCEV) model. Based on a semi-nonparametric approach, a closed-form likelihood function that nests the MNL or MDCEV model being tested is derived. The proposed method allows traditional likelihood ratio tests to be used to test violations of the standard Gumbel distribution assumption. Simulation experiments are conducted to demonstrate that the proposed test yields acceptable Type-I and Type-II error probabilities at commonly available sample sizes. The test is then applied to three real-world discrete and discrete-continuous choice models. For all three models, the proposed test rejects the validity of the standard Gumbel distribution in most utility functions, calling for the development of robust choice models that overcome adverse effects of violations of distributional assumptions on the error terms in random utility functions.

30 DIRECT ENERGY CONVERSION↗

Approaching the investigation of plasma turbulence through a rigorous verification and validation procedure: A practical example

In the present work, a Verification and Validation procedure is presented and applied showing, through a practical example, how it can contribute to advancing our physics understanding of plasma turbulence. Bridging the gap between plasma physics and other scientific domains, in particular, the computational fluid dynamics community, a rigorous methodology for the verification of a plasma simulation code is presented, based on the method of manufactured solutions. This methodology assesses that the model equations are correctly solved, within the order of accuracy of the numerical scheme. The technique to carry out a solution verification is described to provide a rigorous estimate of the uncertainty affecting the numerical results. A methodology for plasma turbulence code validation is also discussed, focusing on quantitative assessment of the agreement between experiments and simulations. The Verification and Validation methodology is then applied to the study of plasma turbulence in the basic plasma physics experiment TORPEX [Fasoli et al., Phys. Plasmas 13, 055902 (2006)], considering both two-dimensional and three-dimensional simulations carried out with the GBS code [Ricci et al., Plasma Phys. Controlled Fusion 54, 124047 (2012)]. The validation procedure allows progress in the understanding of the turbulent dynamics in TORPEX, by pinpointing the presence of a turbulent regime transition, due to the competition between the resistive and ideal interchange instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Chemical 13Ca Chemical Shift Calculations for Protein NMR Structure Determination, Refinement, and Validation

A recently determined set of 20 NMR-derived conformations of a 48-residue all-?-helical protein, (PDB ID code 2JVD), is validated here by comparing the observed 13C? chemical shifts with those computed at the density functional level of theory. In addition, a recently introduced physics-based method, aimed at determining protein structures by using NOE-derived distance constraints together with observed and computed 13C? chemical shifts, was applied to determine a new set of 10 conformations, (Set-bt), as a blind test for the same protein. A cross-validation of these two sets of conformations in terms of the agreement between computed and observed 13C? chemical shifts, several stereochemical quality factors, and some NMR quality assessment scores reveals the good quality of both sets of structures. We also carried out an analysis of the agreement between the observed and computed 13C? chemical shifts for a slightly longer construct of the protein solved by x-ray crystallography at 2.0-A resolution (PDB ID code 3BHP) with an identical amino acid residue sequence to the 2JVD structure for the first 46 residues. Our results reveal that both of the NMR-derived sets, namely 2JVD and Set-bt, are somewhat better representations of the observed 13C? chemical shifts in solution than the 3BHP crystal structure. In addition, the 13C?-based validation analysis appears to be more sensitive to subtle structural differences across the three sets of structures than any other NMR quality-assessment scores used here, and, although it is computationally intensive, this analysis has potential value as a standard procedure to determine, refine, and validate protein structures.

36 MATERIALS SCIENCE↗

Development of a Validation Approach for an Integrated Waste Glass Melter Model

Integrated models are being developed to represent the physics occurring within the high-level and low-activity waste melters that will be used to vitrify legacy tank waste at the Hanford site. These models couple the melt pool, cold cap, and plenum region within a single computational domain. Validation of the models is essential to ensure the reliability of the numerical predictions of the operational melters. Experimental data from laboratory- and pilot-scale tests are thus being used to inform and validate various aspects of the melter model. This study presents a tiered approach to model validation consisting of a series of progressively more complex test cases designed to model the physics occurring in the full-scale system. A hierarchical methodology has been developed to segregate and simplify the physical phenomena affecting the multiphase flow and heat transfer within a waste glass melter. Finally, four hierarchical levels are defined in a validation pyramid and built up in levels of increasing complexity from unit problems to subsystem cases, to pilot-scale systems, and then to the full-scale system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation Studies of RELAP5-3D for High-Temperature Gas-Cooled Reactor Analysis Using a Refined RELAP5-3D Model of the High Temperature Test Facility

RELAP5-3D has been used extensively for high-temperature gas-cooled reactor (HTGR) analysis, but such analysis lies outside the validation basis for the code. Oregon State University (OSU) and the United States Department of Energy’s (DOE) Advanced Reactor Technologies (ART) – Gas-cooled reactor campaign worked together to design and operate the High Temperature Test Facility (HTTF) at OSU to provide validation data for prismatic HTGR thermal hydraulics analysis. Work using a previous RELAP5-3D model of HTTF demonstrated the ability to reproduce trends in HTTF data but an inability to reproduce the values measured in multiple experiments within the uncertainty. It was hypothesized that a new model with a finer radial nodalization would perform better for HTTF analysis. In this paper, we present the development of that more refined model and analyze HTTF experiments PG-27 and PG-29, a pressurized (PCC) and depressurized conduction cooldown (DCC) transient. Comparing PG-27 results to experimental data shows a better prediction of steady state and transient temperatures; however, a deeper dive reveals that better transient temperature predictions are a result of better initial conditions. The transient temperature rise in the core is comparable between the two models, but the legacy model predicts temperatures in the reflectors better. The new model demonstrates the ability to predict unique temperatures in each sector of the core during PG-29, capturing the azimuthal asymmetry; however, the temperature predictions still differ from measured temperatures. One hypothesis is that differences between the assumed and actual power distribution leads to the underprediction of the individual block temperatures. These results suggest that gaps and uncertainties in the measured boundary conditions for the HTTF tests do not allow to fully validate RELAP5-3D for prismatic HTGR analyses. The authors suspect that some of the differences between predicted and measured temperatures may be a result of uncertainties associated with HTTF itself rather than RELAP5-3D. We demonstrated improved validation for steady-state analysis, but significantly improved transient performance has yet to be recognized.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Extending the Nuclide Inventory Validation Basis for High-Burnup Fuel with New Radiochemical Assay Data

Efforts are underway at Oak Ridge National Laboratory to improve the nuclide inventory validation basis for spent nuclear fuel at high burnups. Recently conducted radiochemical assay experiments provided new measurement data for nine samples of fuel irradiated in a pressurized water reactor, with estimated sample burnups in the 30 to 70 GWd/t range. This type of destructive assay data is essential for validating computational methods, tools, and nuclear data applied in nuclear safety analyses and for improving our understanding of the bias and uncertainty in code predictions. The measurement data include key actinides and fission products that span a gamut of needs and interests for nuclear science and engineering applications in criticality safety, reactor physics, nuclide inventory, decay heat, and radiation shielding. The SCALE 6.3 code system with ENDF/B-VII.1 cross-section libraries was used to simulate the irradiation histories of the measured fuel samples. The calculated nuclide concentrations are compared to corresponding measurement data. The significance of the comparisons is discussed, emphasizing how the addition of the new measurement data fills gaps in the validation basis at high burnups and contributes to the decrease in bias and uncertainty for predicted nuclide concentrations. The discussion addresses the effect of the sample burnup used in the simulation—which is based on reactor operator records or on calibration to measured data for burnup indicator fission products—on the validation results.

Nuclide inventory↗

Validation of theory-based models for the control of plasma currents in W7-X divertor plasmas

A theory-based model for the control of plasma currents for steady-state operation in W7-X is proposed and intended for model-based plasma control. The conceptual outline implies the strength of physics-based models: it offer approaches applicable to future conditions of fusion devices or next-step machines. The application at extrapolated settings is related to the validity range of the theory model. Therefore, the predictive power of theory-based control models could be larger than for data-driven approaches and limitations can be predicted from the validity range for the prediction of bootstrap currents in W7-X. The model predicts the L/R response when density or heating power is changed. The model is based on neoclassical bootstrap current calculations and validated for different discharge conditions. While the model was found to be broadly applicable for conducted electron-cyclotron-heated discharges in W7-X, limits were found for cases when the polarization of the electron cyclotron heating was changed from X2 to O2-heating. The validity assessment attempts to quantify the potential of the derived model for model-based control in the operational space (density, heating power) of W7-X.

neoclassical modelling↗

Statistical validation of event predictors: A comparative study based on the field of seizure prediction

The prediction of events is of substantial interest in many research areas. To evaluate the performance of prediction methods, the statistical validation of these methods is of utmost importance. Here, we compare an analytical validation method to numerical approaches that are based on Monte Carlo simulations. The comparison is performed in the field of the prediction of epileptic seizures. In contrast to the analytical validation method, we found that for numerical validation methods insufficient but realistic sample sizes can lead to invalid high rates of false positive conclusions. Hence we outline necessary preconditions for sound statistical tests on above chance predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New tools for the analysis and validation of cryo-EM maps and atomic models

Recent advances in the field of electron cryomicroscopy (cryo-EM) have resulted in a rapidly increasing number of atomic models of biomacromolecules that have been solved using this technique and deposited in the Protein Data Bank and the Electron Microscopy Data Bank. Similar to macromolecular crystallography, validation tools for these models and maps are required. While some of these validation tools may be borrowed from crystallography, new methods specifically designed for cryo-EM validation are required. Here, new computational methods and tools implemented in PHENIX are discussed, including d 99 to estimate resolution, phenix.auto_sharpen to improve maps and phenix.mtriage to analyze cryo-EM maps. It is suggested that cryo-EM half-maps and masks should be deposited to facilitate the evaluation and validation of cryo-EM-derived atomic models and maps. The application of these tools to deposited cryo-EM atomic models and maps is also presented.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-terminal Subsystem Model Validation for Pacific DC Intertie

this paper proposes to validate dynamic model of Pacific DC Intertie with the concept of hybrid simulation by combing simulation with PMU measurements. The Playback function available in GE PSLF is adopted for hybrid simulation. It is demonstrated for the first time the feasibility of using Playback function on multi-terminal subsystem. Sensitivity studies are also presented as a result of common PMU measurement quality problem, ie, offset noise and time synchronization. Results indicate a good tolerance of PDCI model generally. It is recommended that requirements should apply to phasor measurements in model validation work to ensure better analysis. Key parameters are identified based on impact of value change to model behavior. Two events are employed for preliminary model validation with PMU measurements. Suggestions are made for PDCI model validation work in the future.

Pacific DC Intertie, model validation, hybrid simu↗

Validation of Synthetic U.S. Electric Power Distribution System Data Sets

There is a strong need for synthetic yet realistic distribution system test data sets that are as diverse, large, and complex to solve as real systems. Such data sets can facilitate the development of advanced algorithms and the assessment of emerging distributed energy resources while avoiding the need to acquire proprietary critical infrastructure or private data. Such synthetic data sets, however, are useful only if they are realistic enough to look and behave similarly to actual systems. This paper presents a comprehensive framework for validating synthetic distribution data sets using a three-pronged statistical, operational, and expert validation approach. Furthermore, it also presents a set of statistical and operational metric targets for achieving realistic data sets based on detailed characterization of more than 10,000 real U.S. utility feeders. The paper demonstrates the use of the proposed validation approach to validate three large-scale synthetic data sets developed by the authors representing Santa Fe, New Mexico; Greensboro, North Carolina; and the San Francisco Bay Area, California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of finite-element models using full-field experimental data: Levelling finite-element analysis data through a digital image correlation engine

Full-field data from digital image correlation (DIC) provide rich information for finite-element analysis (FEA) validation. However, there are several inherent inconsistencies between FEA and DIC data that must be rectified before meaningful, quantitative comparisons can be made, including strain formulations, coordinate systems, data locations, strain calculation algorithms, spatial resolutions and data filtering. As such, in this paper, we investigate two full-field validation approaches: (1) the direct interpolation approach, which addresses the first three inconsistencies by interpolating the quantity of interest from one mesh to the other, and (2) the proposed DIC-levelling approach, which addresses all six inconsistencies simultaneously by processing the FEA data through a stereo-DIC simulator to ‘level’ the FEA data to the DIC data in a regularisation sense. Synthetic ‘experimental’ DIC data were generated based on a reference FEA of an exemplar test specimen. The direct interpolation approach was applied, and significant strain errorswere computed, even though therewas no model form error, because the filtering effect of theDIC enginewas neglected. In contrast, the levelling approach provided accurate validation results, with no strain error when no model form error was present. Next, model form error was purposefully introduced via a mismatch of boundary conditions. With the direct interpolation approach, the mismatch in boundary conditions was completely obfuscated, while with the levelling approach, it was clearly observed. Finally, the ‘experimental’ DIC datawere purposefully misaligned slightly fromthe FEA data. Both validation techniques suffered from the misalignment, thus motivating continued efforts to develop a robust alignment process. In conclusion, direct interpolation is insufficient, and the proposed levelling approach is required to ensure that the FEA and the DIC data have the same spatial resolution and data filtering. Only after the FEA data have been ‘levelled’ to the DIC data can meaningful, quantitative error maps be computed.

42 ENGINEERING↗

Validation of a Monte Carlo model used for simulating tube current modulation in computed tomography over a wide range of phantom conditions/challenges

Purpose: Monte Carlo (MC) simulation methods have been widely used in patient dosimetry in computed tomography (CT), including estimating patient organ doses. However, most simulation methods have undergone a limited set of validations, often using homogeneous phantoms with simple geometries. As clinical scanning has become more complex and the use of tube current modulation (TCM) has become pervasive in the clinic, MC simulations should include these techniques in their methodologies and therefore should also be validated using a variety of phantoms with different shapes and material compositions to result in a variety of differently modulated tube current profiles. The purpose of this work is to perform the measurements and simulations to validate a Monte Carlo model under a variety of test conditions where fixed tube current (FTC) and TCM were used. Methods: A previously developed MC model for estimating dose from CT scans that models TCM, built using the platform of MCNPX, was used for CT dose quantification. In order to validate the suitability of this model to accurately simulate patient dose from FTC and TCM CT scan, measurements and simulations were compared over a wide range of conditions. Phantoms used for testing range from simple geometries with homogeneous composition (16 and 32 cm computed tomography dose index phantoms) to more complex phantoms including a rectangular homogeneous water equivalent phantom, an elliptical shaped phantom with three sections (where each section was a homogeneous, but different material), and a heterogeneous, complex geometry anthropomorphic phantom. Each phantom requires varying levels of x-, y- and z-modulation. Each phantom was scanned on a multidetector row CT (Sensation 64) scanner under the conditions of both FTC and TCM. Dose measurements were made at various surface and depth positions within each phantom. Simulations using each phantom were performed for FTC, detailed x–y–z TCM, and z-axis-only TCM to obtain dose estimates. This allowed direct comparisons between measured and simulated dose values under each condition of phantom, location, and scan to be made. Results: For FTC scans, the percent root mean square (RMS) difference between measurements and simulations was within 5% across all phantoms. For TCM scans, the percent RMS of the difference between measured and simulated values when using detailed TCM and z-axis-only TCM simulations was 4.5% and 13.2%, respectively. For the anthropomorphic phantom, the difference between TCM measurements and detailed TCM and z-axis-only TCM simulations was 1.2% and 8.9%, respectively. For FTC measurements and simulations, the percent RMS of the difference was 5.0%. Conclusions: This work demonstrated that the Monte Carlo model developed provided good agreement between measured and simulated values under both simple and complex geometries including an anthropomorphic phantom. This work also showed the increased dose differences for z-axis-only TCM simulations, where considerable modulation in the x–y plane was present due to the shape of the rectangular water phantom. Results from this investigation highlight details that need to be included in Monte Carlo simulations of TCM CT scans in order to yield accurate, clinically viable assessments of patient dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗