Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Image reconstruction techniques applied to nuclear mass models

A new procedure is presented that combines well-known nuclear models with image reconstruction techniques. A color-coded image is built by taking the differences between measured masses and the predictions given by the different theoretical models. This image is viewed as part of a larger array in the (N,Z) plane, where unknown nuclear masses are hidden, covered by a 'mask'.' We apply a suitably adapted deconvolution algorithm, used in astronomical observations, to 'open the window' and see the rest of the pattern. We show that it is possible to improve significantly mass predictions in regions not too far from measured nuclear masses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Layered Structures of Cuprous Chalcogenides as Thin Film Solar Cell Materials: Cu 2 Te and Cu 2 Se

The stable crystal structures of two cuprous chalcogenides of Cu 2 X (X = Te or Se) are predicted using an adaptive genetic algorithm in combination with first-principles density functional theory calculations. Both systems are found to prefer a unique and previously unrecognized layered structure, with the total energies much lower than all structures proposed in the literature so far. The newly discovered structures are further shown to be dynamically and mechanically stable, and possess electronic properties consistent with existing experimental observations. In particular, their layered nature is expected to prevail over other structural forms at the interfaces of thin-film solar cells, and knowledge about the precise atomic structures of the interfaces is a prerequisite for achieving long-term stability and high efficiency of CdTe and Cu(In; Ga)Se 2 solar cells.

14 SOLAR ENERGY↗

Machine learning-accelerated discovery of iron cobalt phosphides as rare-earth-free magnets

Here, the discovery of rare-earth-free permanent magnets has been a goal of scientists for decades. The absence of rare-earth elements will alleviate a pressing concern about the availability of rare-earth elements used in permanent magnets. These magnets are crucial for applications such as wind turbines, electric cars, and memory devices. Rare-earth magnets are special owing to a large magnetic anisotropy energy (K 1 ). In contrast, iron cobalt phosphides hold promise since doping P into cubic FeCo can induce anisotropy, leading to a large coercivity, without introducing rare-earth elements. We present a comprehensive search over the Fe-Co-P ternary space for magnets, utilizing recently developed adaptive machine learning feedback to efficiently screen over 850 000 structures. We focus on machine learning acceleration as a paradigm for materials design. Further adaptive genetic algorithm searches and first-principles calculations aid in the identification of 16 new structures below the known convex hull. Five of them possess high magnetic polarization (J s > 1 T). The structures with desirable magnetic properties center on (Fe,Co) 2⁢ P. This supports conventional wisdom, which focuses on the mixture of the two known end compounds: Fe 2 ⁢P and Co 2 ⁢P. Our work provides guidance for synthesis. We find Fe 7 ⁢CoP 4 shows the most promise (J s = 1.03T and K 1 = 0.83MJ/m 3 ).

36 MATERIALS SCIENCE↗

Adaptive Load Shedding for Grid Emergency Control via Deep Reinforcement Learning

Emergency control, typically such as under-voltage load shedding (UVLS), is broadly used to grapple with low voltage and voltage instability issues in real-world power systems under contingencies. However, existing emergency control schemes are rule-based and cannot be adaptively applied to uncertain and floating operating conditions. Here, we propose an adaptive UVLS algorithm for emergency control via deep reinforcement learning (DRL) and expert systems. We first construct dynamic components for picturing the power system operation as the environment. The transient voltage recovery criteria, which poses time-varying requirements to UVLS, is integrated into the states and reward function to advise the learning of deep neural networks. The proposed method has no tuning issue of coefficients in reward functions, and this issue was regarded as a deficiency in the existing DRL-based algorithms. Case studies illustrate that the proposed method outperforms the traditional UVLS relay in both the timeliness and efficacy for emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable Hybrid Scheme for Ray-Casting of Unstructured Volume Data

We present an algorithm for parallel volume rendering that is a hybrid between classical object order and image order techniques. The algorithm operates on unstructured grids (and structured ones), and thus can deal with block boundaries interleaving in complex ways. It also deals effectively with cases that are prone to load imbalance, i.e., cases where cell sizes differ dramatically, either because of the nature of the input data, or because of the effects of the camera transformation. The algorithm divides work over resources such that each phase of its processing is bounded in the amount of computation it can perform. We demonstrate its efficacy through a series of studies, varying over camera position, data set size, transfer function, image size, and processor count. At its biggest, our experiments scaled up to 8,192 processors and operated on data sets with more than one billion cells. In total, we find that our hybrid algorithm performs well in all cases. This is because our algorithm naturally adapts its computation based on workload, and can operate like either an object order technique or an image order technique in scenarios where those techniques are efficient.

97 MATHEMATICS AND COMPUTING↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated size-specific CT dose monitoring program: Assessing variability in CT dose

Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-11: A Segmentation and Point Matching Enhanced Deformable Image Registration Method for Dose Accumulation Between HDR CT Images

Purpose: To propose and validate a novel and accurate deformable image registration (DIR) scheme to facilitate dose accumulation among treatment fractions of high-dose-rate (HDR) gynecological brachytherapy. Method: We have developed a method to adapt DIR algorithms to gynecologic anatomies with HDR applicators by incorporating a segmentation step and a point-matching step into an existing DIR framework. In the segmentation step, random walks algorithm is used to accurately segment and remove the applicator region (AR) in the HDR CT image. A semi-automatic seed point generation approach is developed to obtain the incremented foreground and background point sets to feed the random walks algorithm. In the subsequent point-matching step, a feature-based thin-plate spline-robust point matching (TPS-RPM) algorithm is employed for AR surface point matching. With the resulting mapping, a DVF characteristic of the deformation between the two AR surfaces is generated by B-spline approximation, which serves as the initial DVF for the following Demons DIR between the two AR-free HDR CT images. Finally, the calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. Results: The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative results as well as the visual inspection of the DIR indicate that our proposed method can suppress the interference of the applicator with the DIR algorithm, and accurately register HDR CT images as well as deform and add interfractional HDR doses. Conclusions: We have developed a novel and robust DIR scheme that can perform registration between HDR gynecological CT images and yield accurate registration results. This new DIR scheme has potential for accurate interfractional HDR dose accumulation. This work is supported in part by the National Natural ScienceFoundation of China (no 30970866 and no 81301940)

60 APPLIED LIFE SCIENCES↗

TU-CD-BRB-10: 18F-FDG PET Image-Derived Tumor Features Highlight Altered Pathways Identified by Trancriptomic Analysis in Head and Neck Cancer

Purpose: Several quantitative features can be extracted from 18F-FDG PET images, such as standardized uptake values (SUVs), metabolic tumor volume (MTV), shape characterization (SC) or intra-tumor radiotracer heterogeneity quantification (HQ). Some of these features calculated from baseline 18F-FDG PET images have shown a prognostic and predictive clinical value. It has been hypothesized that these features highlight underlying tumor patho-physiological processes at smaller scales. The objective of this study was to investigate the ability of recovering alterations of signaling pathways from FDG PET image-derived features. Methods: 52 patients were prospectively recruited from two medical centers (Brest and Poitiers). All patients underwent an FDG PET scan for staging and biopsies of both healthy and primary tumor tissues. Biopsies went through a transcriptomic analysis performed in four spates on 4×44k chips (Agilent™). Primary tumors were delineated in the PET images using the Fuzzy Locally Adaptive Bayesian algorithm and characterized using 10 features including SUVs, SC and HQ. A module network algorithm followed by functional annotation was exploited in order to link PET features with signaling pathways alterations. Results: Several PET-derived features were found to discriminate differentially expressed genes between tumor and healthy tissue (fold-change >2, p<0.01) into 30 co-regulated groups (p<0.05). Functional annotations applied to these groups of genes highlighted associations with well-known pathways involved in cancer processes, such as cell proliferation and apoptosis, as well as with more specific ones such as unsaturated fatty acids. Conclusion: Quantitative features extracted from baseline 18F-FDG PET images usually exploited only for diagnosis and staging, were identified in this work as being related to specific altered pathways and may show promise as tools for personalizing treatment decisions.

60 APPLIED LIFE SCIENCES↗

MO-DE-207B-11: Reliability of PET/CT Radiomics Features in Functional and Morphological Components of NSCLC Lesions: A Repeatability Analysis in a Prospective Multicenter Cohort

Purpose: The goal of this study was to evaluate the repeatability of radiomics features (intensity, shape and heterogeneity) in both PET and low-dose CT components of test-retest FDG-PET/CT images in a prospective multicenter cohort of 74 NSCLC patients from ACRIN 6678 and a similar Merck trial. Methods: Seventy-four patients with stage III-IV NCSLC were prospectively included. The primary tumor and up to 3 additional lesions per patient were analyzed. The Fuzzy Locally Adaptive Bayesian algorithm was used to automatically delineate metabolically active volume (MAV) in PET. The 3D SlicerTM software was exploited to delineate anatomical volumes (AV) in CT. Ten intensity first-order features, as well as 26 textural features and four 3D shape descriptors were calculated from tumour volumes in both modalities. The repeatability of each metric was assessed by Bland-Altman analysis. Results: One hundred and five lesions (primary tumors and nodal or distant metastases) were delineated and characterized. The MAV and AV determination had a repeatability of −1.4±11.0% and −1.2±18.7% respectively. Several shape and heterogeneity features were found to be highly or moderately repeatable (e.g., sphericity, co-occurrence entropy or intensity size-zone matrix zone percentage), whereas others were confirmed as unreliable with much higher variability (more than twice that of the corresponding volume determination). Conclusion: Our results in this large multicenter cohort with more than 100 measurements confirm the PET findings in previous studies (with <30 lesions). In addition, our study is the first to explore the repeatability of radiomics features in the low-dose CT component of PET/CT acquisitions (previous studies considered dosimetry CT, CE-CT or CBCT). Several features were identified as reliable in both PET and CT components and could be used to build prognostic models. This work has received a French government support granted to the CominLabs excellence laboratory and managed by the National Research Agency in the “Investing for the Future” program under reference ANR-10-LABX-07-01, and support from the city of Brest.

60 APPLIED LIFE SCIENCES↗

Butterfly Factorization Via Randomized Matrix-Vector Multiplications

This paper presents an adaptive randomized algorithm for computing the butterfly factorization of an m × n matrix with m ≈ n provided that both the matrix and its transpose can be rapidly applied to arbitrary vectors. The resulting factorization is composed of O(log n) sparse factors, each containing O(n) nonzero entries. The factorization can be attained using O(n 3/2 log n) computation and O(n log n) memory resources. Furthermore, the proposed algorithm can be implemented in parallel and can apply to matrices with strong or weak admissibility conditions arising from surface integral equation solvers as well as multi-frontal-based finite-difference, finite-element, or finite-volume solvers. A distributed-memory parallel implementation of the algorithm demonstrates excellent scaling behavior.

97 MATHEMATICS AND COMPUTING↗

Error-controlled, progressive, and adaptable retrieval of scientific data with multilevel decomposition

Extreme-scale simulations and high-resolution instruments have been generating an increasing amount of data, which poses significant challenges to not only data storage during the run, but also post-processing where data will be repeatedly retrieved and analyzed for a long period of time. The challenges in satisfying a wide range of post-hoc analysis needs while minimizing the I/O overhead caused by inappropriate and/or excessive data retrieval should never be left unmanaged. In this paper, we propose a data refactoring, compressing, and retrieval framework capable of 1) fine-grained data refactoring with regard to precision; 2) incrementally retrieving and recomposing the data in terms of various error bounds; and 3) adaptively retrieving data in multi-precision and multi-resolution with respect to different analysis. With the progressive data re-composition and the adaptable retrieval algorithms, our framework significantly reduces the amount of data retrieved when multiple incremental precision are requested and/or the downstream analysis time when coarse resolution is used. Experiments show that the amount of data retrieved under the same progressively requested error bound using our framework is 64% less than that using state-of-the-art single-error-bounded approaches. Parallel experiments with up to 1, 024 cores and ~ 600 GB data in total show that our approach yields 1.36× and 2.52× performance over existing approaches in writing to and reading from persistent storage systems, respectively.

Liang, Xin↗

pCamal

The Parallel CUBIT Adaptive Mesh Algorithm Library (pCAMAL) is a distributed-memory embarrassingly parallel hexahedral mesh generator. pCAMAL utilizes the sweeping method following a serial step of geometry decomposition conducted in the CUBIT geometry preparation and mesh generation tool. pCAMAL also reports mesh quality statistics as calculated in parallel from per-element quality metrics.

Pebay, Philippe↗

Spatiotemporal Plasma-Particle Characterization of Dry Aerosols Using Nanosecond, Femtosecond, and Filament Laser-Produced Plasmas

The ability to rapidly characterize dry aerosols in air using laser-induced breakdown spectroscopy (LIBS) with femtosecond laser pulses promises advancement towards real-time atmospheric sampling and standoff capabilities. Of particular interest is the ability to apply LIBS in the context of low-particle loaded environments where discrete particle interactions must be observed within the sampling volume of the laser-produced plasma (LPP). In this study, dry nanoparticles in suspension are generated from a standard solution and sampled in air using Q-switched nanosecond (ns-) pulses, short-focus (SF) femtosecond (fs-) pulses, and filaments. Short time-gated plasma images are captured to observe spatially and temporally varying discrete plasma-particle interactions, which is shown to influence early air breakdown behavior and subsequent plasma evolution. Along with images, photo-multiplier tube (PMT) measurements are conducted where strong spatiotemporal dependencies are exhibited by the collected emission signal on particle proximity and plasma expansion behavior. Finally, conditional analysis is performed on LIBS measurements to determine associated sampling probabilities and filter out spectra with poor or absent emission peaks with an adaptive threshold algorithm.

42 ENGINEERING↗

Incoherent range-based holography of far-distant objects using LIDAR

Los Alamos National Laboratory has developed an incoherent, long-range, sub-centimeter resolution (LIDAR) with which we achieve centimeter-scale reflection holography at extremely long ranges. The system consists of a pulsed laser and photon-counting receiver. This combination yields round-trip time of flight data to illuminate parts of the object of interest. The aggregation of these data for many LIDAR pulses yields a plot with a range on the X axis and reflectance on the Y axis, which we refer to as a range profile. Observing that the range profile is a projection of the reflection map of the object onto the view vector, we collect profiles from a variety of viewing angles and invert these data to form an image. We adapt imaging algorithms from the field of computer aided tomography to suit our application and present results from imaging demonstrations at a 10 km range.

Hoffmann, Mitchell P. (ORCID:0000000170551324)↗

Dynamic Tuning of Seismic Signal Detector Trigger Levels for Local Networks

The quality of automatic signal detections from sensor networks depends on individual detector trigger levels (TLs) from each sensor. The largely manual process of identifying effective TLs is painstaking and does not guarantee optimal configuration settings, yet achieving superior automatic detection of signals and ultimately, events, is closely related to these parameters. In this paper, we present a Dynamic Detector Tuning (DDT) system that automatically adjusts effective TL settings for signal detectors to the current state of the environment by leveraging cooperation within a local neighborhood of network sensors. After a stabilization period, the DDT algorithm can adapt in near-real time to changing conditions and automatically tune a signal detector to identify (detect) signals from only events of interest. Our current work focuses on reducing false signal detections early in the seismic signal processing pipeline, which leads to fewer false events and has a significant impact on reducing analyst time and effort. This system provides an important new method to automatically tune detector TLs for a network of sensors and is applicable to both existing sensor performance boosting and new sensor deployment. Finally, with ground truth on detections from a local neighborhood of seismic sensors within a network monitoring the Mount Erebus volcano in Antarctica, we show that DDT reduces the number of false detections by 18% and the number of missed detections by 11% when compared with optimal fixed TLs for all sensors.

58 GEOSCIENCES↗