Search NASA⌕ Search

SEARCH · Search NASA

Results for “antenna array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

THE PRECISION AND ACCURACY OF EARLY EPOCH OF REIONIZATION FOREGROUND MODELS: COMPARING MWA AND PAPER 32-ANTENNA SOURCE CATALOGS

As observations of the Epoch of Reionization (EoR) in redshifted 21 cm emission begin, we assess the accuracy of the early catalog results from the Precision Array for Probing the Epoch of Reionization (PAPER) and the Murchison Wide-field Array (MWA). The MWA EoR approach derives much of its sensitivity from subtracting foregrounds to <1% precision, while the PAPER approach relies on the stability and symmetry of the primary beam. Both require an accurate flux calibration to set the amplitude of the measured power spectrum. The two instruments are very similar in resolution, sensitivity, sky coverage, and spectral range and have produced catalogs from nearly contemporaneous data. We use a Bayesian Markov Chain Monte Carlo fitting method to estimate that the two instruments are on the same flux scale to within 20% and find that the images are mostly in good agreement. We then investigate the source of the errors by comparing two overlapping MWA facets where we find that the differences are primarily related to an inaccurate model of the primary beam but also correlated errors in bright sources due to CLEAN. We conclude with suggestions for mitigating and better characterizing these effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of W production during ICRF operations: experiments and modeling

For successfully heating plasma with waves in the ion cyclotron range of frequencies (ICRFs), mitigating impurity production is just as crucial as maximizing power coupling, especially in high-Z environments. ICRF can effectively deposit energy on ions, modify turbulence-driven transport, and enhance fusion reaction efficiency, but only when its power coupling has minimal impact on impurity production. To do so, one must rely on a toroidal array of at least three active elements excited with appropriate phasing and power ratio to reduce the currents induced on the antenna frame below levels critical for physical sputtering. In contrast to classic two-strap antennas, which are optimized for dipole phasing with equal power on both straps, three-strap antennas in ASDEX Upgrade (AUG)—but also four-strap antennas in JET, Alcator C-Mod, SPARC and ITER—offer the possibility to act also on the power ratio between the central and outer straps. With optimal settings, impurity production can be reduced substantially, making the ICRF compatible with the high-Z wall. This paper explores the characteristics of the AUG three-strap antennas in terms of impurity production, as well as the key role of plasma composition in this process. Numerical simulations were performed using SSWICH and Petra-M (finite element codes) to quantify impurity production and compare with experimental results. Energies of ions falling on antenna limiters (measured with probes) are well predicted by both codes. These tools are then used to further describe the source of the impurity, namely the gross erosion of tungsten from an ICRF antenna, for different plasma mixtures. Results are also compared to spectroscopy data. Ultimately, we show that deleterious effects of the ICRF on plasma surface interactions will be weaker in plasmas containing larger fractions of highly ionized heavier low-Z impurity, which is typically relevant for experiments relying on impurity seeding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superluminal Labview Code

This labview code is used to set the phase and amplitudes on the 72 antenna of the superluminal machine, and to map out the radiation patter from the superluminal antenna.Each antenna radiates a modulated signal consisting of two separate frequencies, in the range of 2 GHz to 2.8 GHz. The phases and amplitudes from each antenna are controlled by a pair of AD8349 vector modulators (VMs). These VMs set the phase and amplitude of a high frequency signal using a set of four DC inputs, which are controlled by Linear Technologies LTC1990 digital to analog converters (DACs). The labview code controls these DACs through an 8051 microcontroller.This code also monitors the phases and amplitudes of the 72 channels. Near each antenna, there is a coupler that channels a portion of the power into a binary network. Through a labview controlled switching array, any of the 72 coupled signals can be channeled in to the Tektronix TDS 7404 digital oscilloscope. Then the labview code takes an FFT of the signal, and compares it to the FFT of a reference signal in the oscilloscope to determine the magnitude and phase of each sideband of the signal. The code compensates for phase and amplitude errors introduced by differences in cable lengths.The labview code sets each of the 72 elements to a user determined phase and amplitude. For each element, the code runs an iterative procedure, where it adjusts the DACs until the correct phases and amplitudes have been reached.

Wheat, Robert↗

Development of an Integrated Multidiagnostic to Assess the High-Z Impurity Fluxes in the Metallic Environment of WEST Using IMAS

WEST is an actively cooled, long-pulse tokamak with nearly all plasma-facing components (PFC) made of tungsten. One of the aims of WEST is to study plasma operations with tungsten PFCs in preparation for long-pulse operations on high-Z divertor devices, such as ITER. For long-pulse operation, the high-Z impurity content and transport to the core plasma are critical concerns that require further measurement and interpretation to improve plasma performance and PFC durability. This work details the impurity influxes in WEST during a series of discharges in which the lower hybrid (LH) injected power was incrementally increased. An analysis has been performed of measurements collected from an array of edge diagnostics. Visible spectroscopy was utilized to measure the spectral radiances generated by fuel particles (D) and impurities (W, O, and C) at the divertor and at the antennas with a newly developed spectral peak-fitting tool used to analyze the data in WEST. The scrape-off layer (SOL) plasma conditions (n e and T e ) measured at the divertor target with flush Langmuir probes and near the outer mid-plane (OMP) using reciprocating Langmuir probes (RCPs) are used to evaluate the number of ionizations per photons (S/XB) coefficients required to estimate the impurity fluxes obtained with the collisional-radiative model ColRadPy. Here, the array of edge diagnostics discussed in this work, coupled with SOL plasma modeling tools, represents a multidiagnostic interpretative modeling workflow that will continue to be applied to upcoming experimental campaigns on the WEST experiment to assess high-Z impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Far-field Wireless Energy Harvesting for Increased Safeguards Equipment Battery Life.

Modern unattended safeguards equipment (e.g. seals) incorporates many low-power electronic circuits, which are typically powered by expensive and toxic lithium thionyl chloride (LiSOCL2) batteries. The limited life of these batteries necessitates their periodic replacement. This replacement must be performed before total battery discharge to avoid potential loss of continuity of knowledge. Thus, the effective battery capacity becomes significantly less than the actual usable capacity. Additionally, such maintenance is a radiological hazard to personnel, as well as a monetary burden to a safeguards inspectorate. Energy harvesting, a commercially available technology, could extend the operational life of batterypowered equipment to achieve significant efficiencies for safeguards deployments. Energy harvesting is the scavenging and storage of ambient energy sources, such as solar, thermal, and kinetic for use in lowpower electronic applications. While the amount of scavenged energy per unit time may be small, it most often comes from a source that will not be depleted throughout the deployment of the harvesting device. The best-known energy harvesters are solar panels and wind turbines. Recently, far-field wireless energy harvesting has become a commercially available option. Far-field wireless energy harvesting provides consistent, predictable, and un-tethered power over distances up to 50 feet. This process converts radio frequency (RF) energy, both intentionally emitted and ambient, into usable direct current (DC) power. Incorporating far-field wireless energy harvesting into safeguards equipment can significantly extend the equipment’s battery life and perhaps make it indefinite. Furthermore, additional functionality can be added to safeguards equipment without lowering its operational life expectancy. This paper explores the benefits and drawbacks of integrating far-field wireless energy harvesting into a chosen safeguards seal: the Remotely Monitored Sealing Array (RMSA). Specifically, it examines the performance of a commercially available RF harvesting system from Powercast, as well as commercial and custom antenna solutions.

25 ENERGY STORAGE↗

A METHOD TO EXTRACT THE ANGULAR POWER SPECTRUM OF THE EPOCH OF REIONIZATION FROM LOW-FREQUENCY RADIO INTERFEROMETERS

The redshifted 21 cm signal of neutral hydrogen from the epoch of reionization (EoR) is extremely weak and its first detection is therefore expected to be statistical with first-generation low-frequency radio interferometers. In this Letter, we propose a method to extract the angular power spectrum of the EoR from the visibility correlation coefficients p{sub ij} (u, v), instead of the visibilities V{sub ij} (u, v) measured directly by radio interferometers in conventional algorithm. The visibility correlation coefficients are defined as p{sub ij}(u,v)=V{sub ij}(u,v)/{radical}(|V{sub ii}||V{sub jj}|) by introducing the autocorrelation terms V{sub ii} and V{sub jj} such that the angular power spectrum C{sub l} can be obtained through C{sub l} = T {sup 2}{sub 0}(|p{sub ij} (u, v)|{sup 2}), independently of the primary beams of antennas. This also partially removes the influence of receiver gains in the measurement of C{sub l} because the amplitudes of the gains cancel each other out in the statistical average operation of (|p{sub ij} (u, v)|{sup 2}). We use the average system temperature T{sub 0} as a calibrator of C{sub l}, which is dominated by the Milky Way and extragalactic sources in the frequency range that we are interested in, below 200 MHz. Finally, we demonstrate the feasibility of this novel method using the simulated sky maps as targets and the 21 CentiMeter Array (21CMA) as interferometer.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview on Experiments On ITER-like Antenna On JET And ICRF Antenna Design For ITER

Following an overview of the ITER Ion Cyclotron Resonance Frequency (ICRF) system, the JET ITER-like antenna (ILA) will be described. The ILA was designed to test the following ITER issues: (a) reliable operation at power densities of order 8 MW/m{sup 2} at voltages up to 45 kV using a close-packed array of straps; (b) powering through ELMs using an internal (in-vacuum) conjugate-T junction; (c) protection from arcing in a conjugate-T configuration, using both existing and novel systems; and (d) resilience to disruption forces. ITER-relevant results have been achieved: operation at high coupled power density; control of the antenna matching elements in the presence of high inter-strap coupling, use of four conjugate-T systems (as would be used in ITER, should a conjugate-T approach be used); operation with RF voltages on the antenna structures up to 42 kV; achievement of ELM tolerance with a conjugate-T configuration by operating at 3{omega} real impedance at the conjugate-T point; and validation of arc detection systems on conjugate-T configurations in ELMy H-mode plasmas. The impact of these results on the predicted performance and design of the ITER antenna will be reviewed. In particular, the implications of the RF coupling measured on JET will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Here we report on the successful fabrication of orthomode transducer-coupled transition-edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments with the superconductor electronics fabrication facility at SEEQC Inc. Commercial microfabrication foundry could provide increase in detector fabrication throughput for a next-generation CMB experiment, CMB-S4, that would deploy approximately one order of magnitude more detectors than current CMB experiments. We also developed TES bolometers with two TESs in series that have two different superconducting temperatures (Tc) using a superconducting proximity effect between niobium (Nb) and aluminum-manganese (AlMn) alloy. We will discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments and other experiments that require TESs and superconducting RF circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a long-slot microwave plasma source

A 20 cm long 10 cm wide microwave plasma source was realized by inserting two 20 cm long 1.5 mm diameter rod antennas into the plasma. Plasma luminous distributions around the antennas were changed by magnetic field arrangement created by permanent magnets attached to the source. The distributions appeared homogeneous in one direction along the antenna when the spacing between the antenna and the source wall was 7.5 mm for the input microwave frequency of 2.45 GHz. Plasma density and temperature at a plane 20 cm downstream from the microwave shield were measured by a Langmuir probe array at 150 W microwave power input. The measured electron density and temperature varied over space from 3.0 × 10{sup 9} cm{sup −3} to 5.8 × 10{sup 9} cm{sup −3}, and from 1.1 eV to 2.1 eV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Tianlai dish pathfinder array: design, operation, and performance of a prototype transit radio interferometer

ABSTRACT The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about 5% of 6200 h of on-sky observations through 2019 October. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80 K for most feed antennas and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole (NCP), yielded visibilities with amplitudes of 20–30 mK, consistent with the expected signal from the NCP radio sky with ${\lt}10\,$ mK precision for 1 MHz × 1 min binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$ mK level.

(cosmology:) large-scale structure of the Universe↗

Measurements of the parallel wavenumber of lower hybrid waves in the scrape-off layer of a high-density tokamak

In lower hybrid current drive (LHCD) experiments on tokamaks, the parallel wavenumber of lower hybrid waves is an important physics parameter that governs the wave propagation and absorption physics. However, this parameter has not been experimentally well-characterized in the present-day high density tokamaks, despite the advances in the wave physics modeling. In this paper, we present the first measurement of the dominant parallel wavenumber of lower hybrid waves in the scrape-off layer (SOL) of the Alcator C-Mod tokamak with an array of magnetic loop probes. The electric field strength measured with the probe in typical C-Mod plasmas is about one-fifth of that of the electric field at the mouth of the grill antenna. The amplitude and phase responses of the measured signals on the applied power spectrum are consistent with the expected wave energy propagation. At higher density, the observed k{sub ||} increases for the fixed launched k{sub ||}, and the wave amplitude decreases rapidly. This decrease is correlated with the loss of LHCD efficiency at high density, suggesting the presence of loss mechanisms. Evidence of the spectral broadening mechanisms is observed in the frequency spectra. However, no clear modifications in the dominant k{sub ||} are observed in the spectrally broadened wave components, as compared to the measured k{sub ||} at the applied frequency. It could be due to (1) the probe being in the SOL and (2) the limited k{sub ||} resolution of the diagnostic. Future experiments are planned to investigate the roles of the observed spectral broadening mechanisms on the LH density limit problem in the strong single pass damping regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of large dual-polarized multichroic TES bolometer arrays for CMB measurements with the SPT-3G camera

This paper presents the procedures used by Argonne National Laboratory to fabricate large arrays of multichroic transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) measurements. These detectors will be assembled into the focal plane for the SPT-3G camera, the third generation CMB camera to be installed in the South Pole Telescope. The complete SPT-3G camera will have approximately 2690 pixels, for a total of 16,140 TES bolometric detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a Nb microstrip line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES bolometers. There are six TES bolometer detectors per pixel, which allow for measurements of three band-passes (95 GHz, 150 GHz and 220 GHz) and two polarizations. The steps involved in the monolithic fabrication of these detector arrays are presented here in detail. Patterns are defined using a combination of stepper and contact lithography. The misalignment between layers is kept below 200 nm. The overall fabrication involves a total of 16 processes, including reactive and magnetron sputtering, reactive ion etching, inductively coupled plasma etching and chemical etching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIRST VIEWS OF A NEARBY LIRG: STAR FORMATION AND MOLECULAR GAS IN IRAS 04296+2923

We present a first look at the local luminous infrared galaxy (LIRG) IRAS 04296+2923. This barred spiral galaxy, overlooked because of its location behind the Taurus molecular cloud, is among the half dozen closest (D = 29 Mpc) LIRGs. More IR-luminous than either M82 or the Antennae, it may be the best local example of a nuclear starburst caused by bar-mediated secular evolution. We present Palomar J and Pa {beta} images, Very Large Array continuum maps from {lambda}= 20-1.3 cm, a subarcsecond Keck Long Wavelength Spectrometer image at 11.7 {mu}m and Owens Valley Millimeter Array CO(1-0), {sup 13}CO(1-0), and 2.7 mm continuum images. The J-band image reveals a symmetric barred spiral galaxy. Two bright, compact mid-infrared and radio sources in the nucleus mark a starburst that is energetically equivalent to {approx}10{sup 5} O7 stars, separated by {approx}<50 pc. This is probably a pair of young super star clusters, with estimated stellar masses of {approx}10{sup 7} M{sub sun} each. The nuclear starburst is forming stars at the rate of {approx}12 {+-} 6 M{sub sun} yr{sup -1}, or about half of the total star formation rate for the galaxy of {approx}25 {+-} 10 M{sub sun} yr{sup -1}. IRAS 04296+2923 is very bright in CO, and among the most gas-rich galaxies in the local universe. The {sup 12}CO luminosity of the inner half kpc is equivalent to that of the entire Milky Way. While the most intense CO emission is extended over a 15'' (2 kpc) diameter region, the nuclear starburst is confined to within 1''-2'' (150-250 pc) of the dynamical center. Based on masses obtained with {sup 13}CO, we find that the CO conversion factor in the nucleus is lower than the Galactic value, X {sup Gal}{sub CO} by a factor of three to four, typical of gas-rich spiral nuclei. The nuclear star formation efficiency (SFE) is {sup nuc}M{sub gas}/SFR{sup nuc} = 2.7 x 10{sup -8}yr{sup -1}, corresponding to a gas consumption timescale, {tau}{sup nuc}{sub SF} {approx} 4 x 10{sup 7} yr. The SFE is 10 times lower in the disk, with {tau}{sup disk}{sub SF} {approx} 3.3 x 10{sup 8} yr. The low absolute SFE in the disk implies that the molecular gas is not completely consumed before it drifts into the nucleus, and is capable of fueling a sustained nuclear starburst. IRAS 04296+2923 appears to be beginning a 100 Myr period as an LIRG, during which it will turn much of its 6 x 10{sup 9} M{sub sun} of molecular gas into a nuclear cluster of stars.

79 ASTRONOMY AND ASTROPHYSICS↗

New cosmic rays experiments in the underground laboratory of IFIN-HH from Slanic Prahova, Romania

Since 2006 a modern laboratory has been developed by IFIN-HH in the underground of Slanic Prahova salt ore. This work presents a short review of previous scientific activities performed in the underground laboratory, in parallel with some plans for the future. A mobile detector for cosmic muon flux measurements has been set up at IFIN-HH, Romania. The device is used to measure the muon flux on different locations at the surface and underground and it consists of two detection layers, each one including four large scintillator plates. A new rotatable detector for measurements of the directional variation of the muon flux has been designed and it is presently under preliminary tests. Built from four layers of sensitive material and using for collecting the signals and directing them to the micro PMTs a new technique, through optical fibers instead wave length shifters, it allows an easy discrimination of the moun flux on the arrival directions of muons. Combining the possibility to rotate and the directionality properties, the underground muon detector is acting like a muon tomography device, being able to scan, using cosmic muons, the rock material above the detector. In parallel new detection system based on SiPM will be also installed in the following weeks. It should be composed by four layers, each layer consisting in 4 scintillator plates what we consider in the following as a module of detection. For this purpose, first two scintillator layers, with the optical fibers positioned on perpendicular directions are put in coincidence with other two layers, 1 m distance from the first two, with similar optical fiber arrangement, thus allowing reconstructing muon trajectory. It is intended also to design and construct an experimental device for the investigation of such radio antennas and the behavior of the signal in rock salt at the Slanic salt mine in Romania. Another method to detect high energy neutrinos is based on the detection of secondary particles resulting from the interaction with the salt massive. We intent to design and construct a 3D array in the underground of Slanic Prahova salt ore.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and simulation of ICRF wave intensity with a recalibrated phase contrast imaging diagnostic on Alcator C-Mod

Waves in the ion cyclotron range of frequencies (ICRF) are one of the major tools to heat fusion plasmas. Full-wave simulations are essential to predict the wave propagation and absorption quantitatively, and it is important that these codes be validated against actual experimental measurements. In this work, the absolute intensity of the ICRF waves previously measured with a phase contrast imaging diagnostic was recalibrated and compared once more with full-wave predictions. In the earlier work, significant discrepancies were found between the measured and the simulated mode converted wave intensity [N. Tsujii et al., Phys. Plasmas 19, 082508]. With the new calibration of the detector array, the measured mode converted wave intensity is now in much better agreement with the full-wave predictions. The agreement is especially good for comparisons performed close to the antenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SiO MASERS AROUND WX PSC MAPPED WITH THE KVN AND VERA ARRAY (KaVA)

We present the first images of the v = 1 and v = 2 J = 1 → 0 SiO maser lines taken with KaVA, i.e., the combined array of the Korean Very Long Baseline Interferometry (VLBI) Network and the VLBI Exploration of Radio Astrometry (VERA), toward the OH/IR star WX Psc. The combination of long and short antenna baselines enabled us to detect a large number of maser spots, which exhibit a typical ring-like structure in both the v = 1 and v = 2 J = 1 → 0 SiO masers as those that have been found in previous VLBI observational results of WX Psc. The relative alignment of the v = 1 and v = 2 SiO maser spots are precisely derived from astrometric analysis, due to the absolute coordinates of the reference maser spot that were well determined in an independent astrometric observation with VERA. The superposition of the v = 1 and v = 2 maser spot maps shows a good spatial correlation between the v = 1 and v = 2 SiO maser features. Nevertheless, it is also shown that the v = 2 SiO maser spot is distributed in an inner region compared to the v = 1 SiO maser by about 0.5 mas on average. These results provide good support for the recent theoretical studies of the SiO maser pumping, in which both the collisional and the radiative pumping predict the strong spatial correlation and the small spatial discrepancy between the v = 1 and v = 2 SiO maser.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostics for the Biased Electrode Experiment on NSTX

A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer (SOL) by creating a strong local poloidal electric field. The set of electrodes were separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the RF antenna and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to ±100 volts. Present power supplies limit the current on two electrodes to 30 amps the other two to 10 amps each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic (GPI) located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗