Search NASA⌕ Search

SEARCH · Search NASA

Results for “attack modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Characterization of Radiative Heating Anomaly in High Enthalpy Shock Tunnels

Surface heating measurements in shock tunnels operating at high enthalpy have previously showed anomalously high heating, the mechanisms for which have been the subject of much speculation. However, recent tests in JAXA’s High Enthalpy Shock Tunnel (HIEST) have presented compelling evidence that the heating anomaly is due to radiation from the shock layer, produced by impurities within the shock. This paper describes a test series performed with an Apollo capsule model at angle of attack. The purpose of the test is nominally to study transition over the capsule model at high enthalpy, however data is confounded by the presence of this radiative heating. The model is thus instrumented with thermocouple heat flux gauges and spectrometer-coupled fiber optics to characterize the spectrum of radiative heating simultaneous to the heat flux measurements. Analyses of the spectra, estimates of radiative heating corrections, and comparison to computational fluid dynamic simulation of the shock tunnel are presented.

Brett A Cruden↗

The Cementitious Barriers Partnership Experimental Programs and Software Advancing DOE’s Waste Disposal/Tank Closure Efforts – 15436

The U.S. Department of Energy Environmental Management (DOE-EM) Office of Tank Waste Management-sponsored Cementitious Barriers Partnership (CBP) is chartered with providing the technical basis for implementing cement-based waste forms and radioactive waste containment structures for long-term disposal. DOE needs in this area include the following to support progress in final treatment and disposal of legacy waste and closure of High-Level Waste (HLW) tanks in the DOE complex: long-term performance predictions, flow sheet development and flow sheet enhancements, and conceptual designs for new disposal facilities. The DOE-EM Cementitious Barriers Partnership is producing software and experimental programs resulting in new methods and data needed for end-users involved with environmental cleanup and waste disposal. Both the modeling tools and the experimental data have already benefited the DOE sites in the areas of performance assessments by increasing confidence backed up with modeling support, leaching methods, and transport properties developed for actual DOE materials. In 2014, the CBP Partnership released the CBP Software Toolbox –“Version 2.0” which provides concrete degradation models for 1) sulfate attack, 2) carbonation, and 3) chloride initiated rebar corrosion, and includes constituent leaching. These models are applicable and can be used by both DOE and the Nuclear Regulatory Commission (NRC) for service life and long-term performance evaluations and predictions of nuclear and radioactive waste containment structures across the DOE complex, including future SRS Saltstone and HLW tank performance assessments and special analyses, Hanford site HLW tank closure projects and other projects in which cementitious barriers are required, the Advanced Simulation Capability for Environmental Management (ASCEM) project which requires source terms from cementitious containment structures as input to their flow simulations, regulatory reviews of DOE performance assessments, and Nuclear Regulatory Commission reviews of commercial nuclear power plant (NPP) structures which are part of the overall US Energy Security program to extend the service life of NPPs. In addition, the CBP experimental programs have had a significant impact on the DOE complex by providing specific data unique to DOE sodium salt wastes at Hanford and SRS which are not readily available in the literature. Two recent experimental programs on cementitious phase characterization and on technetium (Tc) mobility have provided significant conclusions as follows: recent mineralogy characterization discussed in this paper illustrates that sodium salt waste form matrices are somewhat similar to but not the same as those found in blended cement matrices which to date have been used in long-term thermodynamic modeling and contaminant sequestration as a first approximation. Utilizing the CBP generated data in long-term performance predictions provides for a more defensible technical basis in performance evaluations. In addition, recent experimental studies related to technetium mobility indicate that conventional leaching protocols may not be conservative for direct disposal of Tc-containing waste forms in vadose zone environments. These results have the potential to influence the current Hanford supplemental waste treatment flow sheet and disposal conceptual design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind-Tunnel Investigation of Some Effects of Wing Sweep and Horizontal-Tail Height on the Static Stability of an Airplane Model at Transonic Speeds

A research model of an airplane with a configuration suitable for supersonic flight was tested at transonic speeds in order to establish the effects on longitudinal and lateral stability of certain changes in both wing sweep and height of the horizontal tail. Two wings of aspect ratio 3 and taper ratio 0.15, one having the quarter-chord line swept back 30 deg and the other 45 deg, were each tested with the horizontal tail of the model in a low and in a high position. One configuration was also tested with fuselage strakes. The tests were made at Mach numbers from 0.60 to 1.17 and Reynolds numbers from 1.9 x 10(exp 6) to 2.6 x 10(exp 6). The results indicated that a low horizontal-tail position (below the wing-chord plane) gave positive longitudinal stability for the model for all angles of attack used (angles of attack up to 24 deg); whereas, a higher tail position (above the wing-chord plane) resulted in a large reduction in stability at moderate angles of attack. With the higher horizontal tail, the 30 deg-swept-wing model had somewhat more stability than the 45 deg-swept-wing model at subsonic Mach numbers. With the lower tail, the 45 deg-swept-wing model had slightly more stability at all Mach numbers. The model with the 30 deg swept wing had greater directional stability with the tail in the higher rather than the lower position, but the opposite was true for the 45 deg-swept-wing model. The directional stability decreased sharply at high angles of attack; this characteristic was alleviated by the use of fuselage strakes which, however, proved to be detrimental to the longitudinal stability of the model tested.

Fisher, Lewis R.↗

Cyber-Attack Detection for Active Neutral Point Clamped (ANPC) Photovoltaic (PV) Converter using Kalman Filter

With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. Furthermore, the simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.

14 SOLAR ENERGY↗

Aerodynamic characteristics of two general aviation canard configurations at high angles of attack

The results of wind tunnel tests of two propeller driven canard general aviation aircraft models at high angles of attack are reported. Both tractor and pusher prop configurations were examined. Angles of attack of -6 to 40 deg were used with the pusher model at Re of 1,600,000, and from -30 to 90 deg and Re of 550,000 for the tractor model. The tests showed that the canard would stall long before the wing and produce a nose-down tendency, thus effectively keeping the aircraft out of the stall regime. However, a sequence of pilot actions or design factors such as the airfoils, relative geometry of the canard and wing, the propeller location and the center of gravity location could introduce a wide variance in stall characteristics from one aircraft to another.

Chambers, J. R.↗

Wind-Tunnel Investigation of the Low-Speed Static Stability and Control Characteristics of a Model of the Bell MX-776 (RASCAL) in Combined Angle of Attack and Sideslip

An investigation has been made in the Langley stability tunnel to determine the low-speed static stability and control characteristics of a model of the Bell MX-776. The results show the model to be longitudinally unstable in the angle-of-attack range around zero angle of attack and to become stable at moderate angles of attack. The results of the present investigation agree reasonably well with results obtained in other facilities at low speed. The present pitching-moment results at low Mach numbers also agree reasonably well with unpublished results of tests of the model at supersonic Mach numbers (up to Mach number 1.86). Unpublished results at moderate and high subsonic speeds, however, indicate considerably greater instability at low angles of attack than is indicated by low-speed results. The results of the present tests also showed that the pitching-moment coefficients for angles of attack up to 12deg remained fairly constant with sideslip angle up to 12deg. The elevators tested produced relatively large pitching moments at zero angle of attack but, as the angle of attack was increased, the elevator effectiveness decreased. The rate of decrease of elevator effectiveness with angle of attack was less for 8deg than for 20deg elevator deflection. Therefore although 8deg deflection caused an appreciable change in longitudinal trim angle and trim lift coefficient a deflection of 20deg caused only a small additional increase in trim angle and trim lift coefficient.

Letko, William↗

Data-based and secure switched cyber–physical systems

In this work, we develop a completely model-free moving target defense framework for the detection and mitigation of sensor and/or actuator attacks in cyber–physical systems with dynamics that evolve in discrete-time. We incorporate an intrusion detection mechanism based on an approximate dynamic programming technique that learns the policies for optimal regulation and optimal tracking while simultaneously defending against actuator and sensor attacks in a model-free fashion. Switching rules are leveraged to force proactive and reactive defense mechanisms as well as, guarantee the stability of the equilibrium point. Finally, as a case study, we apply the proposed moving target defense framework to a DC–DC converter that is used in electric vehicles.

42 ENGINEERING↗

Investigation of the Low-Speed Stability and Control Characteristics of a 1/10-Scale Model of the Convair YF-102 Airplane in the Langley Free-Flight Tunnel

An investigation of the low-speed, power-off stability and control characteristics of a 1/10-scale model of the Convair YF-102 airplane has been made in the Langley free-flight tunnel. The model was flown over a lift-coefficient range from 0.5 to the stall in its basic configuration and with several modifications involving leading-edge slats and increases in vertical-tail size. Only relatively low-altitude conditions were simulated and no attempt was made to determine the effect of freeing the controls. The longitudinal stability characteristics of the model were considered satisfactory for all conditions investigated. The lateral stability characteristics were considered satisfactory for the basic configuration over the speed range investigated except near the stall, where large values of static directional instability caused the model to be directionally divergent. The addition of leading-edge slats or an 8-percent increase in vertical-tail area increased the angle of attack at which the model became directionally divergent. The use of leading-edge slats in combination with a 40-percent increase in vertical-tail size eliminated the directional divergence and produced satisfactory stability characteristics through the stall. The longitudinal and lateral control characteristics were generally satisfactory. Although the adverse sideslip characteristics for the model were considered satisfactory over the angle-of-attack range, analysis indicates that the adverse sideslip characteristics of the airplane may be objectionable at high angles of attack.

Johnson, Joseph L., Jr.↗

Progress towards extreme attitude testing with Magnetic Suspension and Balance Systems

Progress is reported in a research effort aimed towards demonstration of the feasibility of suspension and aerodynamic testing of models at high angles of attack in wind tunnel Magnetic Suspension and Balance Systems. Extensive modifications, described in this paper, have been made to the Southampton University suspension system in order to facilitate this work. They include revision of electromagnet configuration, installation of all-new position sensors and expansion of control system programs. An angle of attack range of 0 to 90 deg is expected for axisymmetric models. To date, suspension up to 80 deg angle of attack has been achieved.

Britcher, Colin P.↗

Performance Evaluation of Vertical Federated Machine Learning Against Adversarial Threats on Wide-Area Control System: Preprint

Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.

adversarial threats↗

The Double-edged Sword of Data-driven Super-Resolution: Adversarial Super-resolution Models

Data-driven super-resolution (SR) methods are often integrated into imaging pipelines as preprocessing steps to improve downstream tasks such as classification and detection. However, these SR models introduce a previously unexplored attack surface into imaging pipelines. In this paper, we present AdvSR, a framework demonstrating that adversarial behavior can be embedded directly into SR model weights during training, requiring no access to inputs at inference time. Unlike prior attacks that perturb inputs or rely on backdoor triggers, AdvSR operates entirely at the model level. By jointly optimizing for reconstruction quality and targeted adversarial outcomes, AdvSR produces models that appear benign under standard image quality metrics while inducing downstream misclassification. We evaluate AdvSR on three SR architectures (SRCNN, EDSR, SwinIR) paired with a YOLOv11 classifier and demonstrate that AdvSR models can achieve high attack success rates with minimal quality degradation. These findings highlight a new model-level threat for imaging pipelines, with implications for how practitioners source and validate models in safety-critical applications.

Sullivan, Haley [ORNL] (ORCID:0000000274069217)↗

Dynamic surface measurements on a model helicopter rotor during blade slap at high angles of attack

The modern helicopter offers a unique operational capability to both the public and private sectors. However, the use of the helicopter may become severely limited due to the radiated noise generated by the rotor system. A description is presented of some of the experimental results obtained with a model helicopter rotor in an anechoic wind tunnel with regard to blade stall as a source mechanism of blade slap. Attention is given to dynamic rotor blade surface phenomena and the resulting far field impulsive noise from the model helicopter rotor at high angles of attack and low tip speed. The results of the investigation strongly implicates the boundary layer as playing an important role in blade slap due to blade/vortex interaction (BVI) in a highly loaded rotor. Intermittent stall cannot be ruled out as a possible source mechanism for blade slap. This implies that blade surface characteristics, airfoil shape and local Reynolds number may now be used as tools to reduce the resultant far-field sound pressure levels in helicopters.

Hubbard, J. E., Jr.↗

Test Capability Enhancements to the NASA Langley 8-Foot High Temperature Tunnel

The NASA Langley 8-Foot High Temperature Tunnel produces true enthalpy environments simulating flight from Mach 4 to Mach 7, primarily for airbreathing propulsion and aerothermal/thermo-structural testing. Flow conditions are achieved through a methane-air heater and nozzles producing aerodynamic Mach numbers of 4, 5 or 7 and have exit diameters of 8 feet or 4.5 feet. The 12-ft long free-jet test section, housed inside a 26-ft vacuum sphere, accommodates large test articles. Recently, the facility underwent significant upgrades to support hydrocarbon fueled scramjet engine testing and to expand flight simulation capability. The upgrades were required to meet engine system development and flight clearance verification requirements originally defined by the joint NASA-Air Force X-43C Hypersonic Flight Demonstrator Project and now the Air Force X-51A Program. Enhancements to the 8-Ft. HTT were made in four areas: 1) hydrocarbon fuel delivery; 2) flight simulation capability; 3) controls and communication; and 4) data acquisition/processing. The upgrades include the addition of systems to supply ethylene and liquid JP-7 to test articles; a Mach 5 nozzle with dynamic pressure simulation capability up to 3200 psf, the addition of a real-time model angle-of-attack system; a new programmable logic controller sub-system to improve process controls and communication with model controls; the addition of MIL-STD-1553B and high speed data acquisition systems and a classified data processing environment. These additions represent a significant increase to the already unique test capability and flexibility of the facility, and complement the existing array of test support hardware such as a model injection system, radiant heaters, six-component force measurement system, and optical flow field visualization hardware. The new systems support complex test programs that require sophisticated test sequences and precise management of process fluids. Furthermore, the new systems, such as the real-time angle of attack system and the new programmable logic controller enhance the test efficiency of the facility. The motivation for the upgrades and the expanded capabilities is described here.

Harvin, S. F.↗