Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Molecular Dynamics of ULTEM 9085 for 3D Manufacturing: Spectra, Thermodynamic Properties, and Shear Viscosity.

We present results of a molecular dynamic analysis of welding at the polymer-polymer interface. The analysis is performed for polyetherimide/ polycarbonate polymer blends. The work is motivated by the applications to 3D manufacturing in space. In the first part of the report, we discuss bulk and spectral characteristics of the amorphous polymer blends. The vibrational and infra-red spectra obtained using auto-correlation functions calculations in molecular dynamics are compared with the experimental spectra. The mechanical and thermal properties of the samples including heat capacity, bulk modulus, and thermal expansion coefficients are estimated and compared with experimental values. In the second part of the report, we discuss the result of molecular dynamical modeling of shear viscosity in a fully atomistic model of amorphous polymer blends with flat interface. The key result of the research is the demonstration of shear thinning behavior of the shear viscosity as a function of shear rate which is in good agreement with experimental data.

Luchinsky, Dmitry G.↗

Do You See What I See? Interactive Visualization of Mission Design and Navigation

Mission Design and Navigation (MDNav) is an intensive process requiring advanced computational resources, expert human intuition, and many successive human-in-the-loop iterations to converge on acceptable trajectory designs or navigation solutions. The current bottleneck in MDNav is not the underlying computational algorithms but the human cognitive capacity to prune through a multitude of simulated results to select high-value candidates. One approach to alleviate this burden is through the judicious application of visualizations that allow humans to interactively filter data in multiple dimensions to reveal salient patterns and highlight divergences. When designed efficiently, such interactive visualizations should aid human operators to get familiar with data faster, visually observe correlations, and communicate findings more effortlessly. In this work, we present three visualization case studies that have the potential to increase human operator efficiency in MDNav. While identifying the most critical “pain points” that operators face, and also working on potential solutions, we followed a human-centered design approach. We started with a series of interviews with potential users, and then rapidly created prototypes for alternative solutions, validated outcomes with feedback from users through out development of these proof of concept visualizations. With this survey of our current efforts, we demonstrate the transformative capability of interactive data visualizations for improving mission development and operations, enabling operators to grow intuition, and communicating key concepts across diverse mission teams.

Arora, Nitin↗

Coprecipitation of Fe/Cr Hydroxides at Organic–Water Interfaces: Functional Group Richness and (De)protonation Control Amounts and Compositions of Coprecipitates

Iron/chromium hydroxide coprecipitation controls the fate and transport of toxic chromium (Cr) in many natural and engineered systems. Organic coatings on soil and engineered surfaces are ubiquitous; however, mechanistic controls of these organic coatings over Fe/Cr hydroxide coprecipitation are poorly understood. Here, Fe/Cr hydroxide coprecipitation was conducted on model organic coatings of humic acid (HA), sodium alginate (SA), and bovine serum albumin (BSA). The organics bonded with SiO 2 through ligand exchange with carboxyl (-COOH), and the adsorbed amounts and pK(a) values of -COOH controlled surface charges of coatings. The adsorbed organic films also had different complexation capacities with Fe/Cr ions and Fe/Cr hydroxide particles, resulting in significant differences in both the amount (on HA > SA(-COOH) >> BSA(-NH 2 )) and composition (Cr/Fe molar ratio: on BSA(-NH2) >> HA > SA(-COOH)) of heterogeneous precipitates. Negatively charged -COOH attracted more Fe ions and oligomers of hydrolyzed Fe/Cr species and subsequently promoted heterogeneous precipitation of Fe/Cr hydroxide nanoparticles. Organic coatings containing -NH 2 were positively charged at acidic pH because of the high pK(a) value of the functional group, limiting cation adsorption and formation of coprecipitates. Meanwhile, the higher local pH near the -NH 2 coatings promoted the formation of Cr(OH) 3 . Finally, this study advances fundamental understanding of heterogeneous Fe/Cr hydroxide coprecipitation on organics, which is essential for successful Cr remediation and removal in both natural and engineered settings, as well as the synthesis of Cr-doped iron (oxy)hydroxides for material applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Grid Impact of Oregon Offshore Wind [Slides]

This analysis used high-resolution offshore wind data and a detailed production cost model (PCM) of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios vary both offshore wind capacities and the Western Interconnection generation and transmission infrastructure. From the scenario modeling and analysis, we identified the following key findings. In addition, we simulated a subset of the scenarios for a range of historical weather years (2007-2013), to understand the robustness of our findings to different weather conditions. Trans-coastal transmission constraints and congestion are the key drivers to the curtailment of Oregon offshore wind. Once power can be delivered into the Willamette Valley, there are few system constraints that lead to a significant curtailment of offshore wind off the coast of Oregon. Approximately 2.6 GW of installed offshore wind capacity can be integrated into Oregon's power system without major upgrades to trans-coastal transmission while avoiding significant curtailment. The system value provided by offshore wind ranges between $\$65$ /MWh and $\$85$ /MWh across the various scenarios considered. Offshore wind heavily influences the flow of the cross Cascade transmission. Across all scenarios, we found a robust relationship of approximately 500-550 MW decrease in the hourly flow of the cross Cascade transmission for every 1,000 MW of hourly offshore wind generation. However, we also found there was not a strong relationship between the highest cross-Cascade transmission flow hours and high offshore wind generation, limiting the extent to which offshore wind can be considered a non-wires alternative to cross cascade transmission. Depending on the meteorological year, 880-1,580 MW and 1,650-3,100 MW can be counted on to serve coastal loads with 2.6 GW and 5 GW of offshore wind capacity, respectively. Offshore wind allows for more optimal daily and hourly scheduling of hydropower, while still complying with various technical and regulatory constraints on the water resource. Oregon offshore wind has the potential to contribute to the evening net load peak in California (i.e., mitigate duck curve challenges), however transmission congestion between California and Oregon limits this contribution. Co-located storage at the point of interconnection for offshore wind reduces curtailment when trans-coastal transmission is not upgraded, providing a non-wires alternative to increase offshore wind capacity beyond 2.6 GW.

17 WIND ENERGY↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

This study explores tradeoffs between the use of home solar+storage systems for backup power versus day-to-day utility bill savings. The study focuses specifically on the “reserve setting” available with most home battery storage systems, which allow the customer to maintain some minimum level of storage in reserve in case of an unforeseen power interruption. The more capacity that is held in reserve, the greater the customer’s ability to ride-through possible power interruptions, but less capacity is then available to manage utility bills on a day-to-day basis. This study evaluates this operational tradeoff across a diverse set of locations and residential electricity tariff structures, relying on Berkeley Lab’s PRESTO model to stochastically simulate power interruption events, and exploring a range of sensitivities, including variations in customer value of lost load (VoLL), interruption frequency, and other key drivers. The results show that, in most circumstances, the opportunity cost of holding storage capacity in reserve, in terms of foregone bill saving, tends to outweigh any gains in reliability value associated with mitigated power interruptions. This finding is robust across tariff structures and across most of the sensitivities considered, including those related to rate level, customer load level, and storage sizing. There are a limited set of circumstances where raising the reserve setting improves the overall customer value (comprised of bill savings plus reliability value). Specifically, that exception occurs when all of the following conditions apply: (a) the customer resides in a location with exceptionally poor reliability, (b) the customer has exceptionally high VoLL; (c) the customer is on a net billing rate or on a TOU rate that allows grid discharging but not grid charging; and (d), depending on the location, the price arbitrage differential on that rate is relatively small. In all other circumstances analyzed, total customer value declines with reserve level.

14 SOLAR ENERGY↗

The Effect of Variable End of Charge Battery Management on Small-Cell Batteries

ABSL Space Products is the world leading supplier of Lithium-ion batteries for space applications and has pioneered the use of small capacity COTS cells within large arrays. This small-cell approach has provided many benefits to space application designers through increased flexibility and reliability over more traditional battery designs. The ABSL 18650HC cell has been used in most ABSL space battery applications to date and has a recommended End Of Charge Voltage (EOCV) of 4.2V per cell. For all space applications using the ABSL 18650HC so far, this EOCV has been used at all stages of battery life from ground checkout to in orbit operations. ABSL and NASA have identified that, by using a lower EOCV for the same equivalent Depth Of Discharge (DOD), battery capacity fade could be reduced. The intention of this paper is to compare battery performance for systems with fixed and variable EOCV. In particular, the effect of employing the blanket value of 4.2V per cell versus utilizing a lower EOCV at Beginning Of Life (BOL) before gradually increasing it (as the effects of capacity fade drive the End Of Discharge Voltage closer to the acceptable system level minimum) is analyzed. Data is compared from ABSL in-house and NASA GRC tests that have been run under fixed and variable EOCV conditions. Differences in capacity fade are discussed and projections are made as to potential life extension capability by utilizing a variable EOCV strategy.

Neubauer, Jeremy↗

Renewable-Storage Hybrids in a Decarbonized Electricity Supply

We explore the potential impacts of growing industry interest in hybrid systems comprising PV and battery technologies on the results and findings of the Solar Futures Study (2021). Through comparison of Solar Futures Study scenarios with and without PV-battery hybrid configurations enabled (in the same grid planning model), we find that the highest net-value hybrid configuration depends strongly on power sector carbon policy, which increases the value of more forward-looking designs. While the availability of PV-battery hybrid configurations primarily displaces standalone PV and battery capacity, we find that it (a) increases solar's share of total capacity and generation and (b) reduces required transmission expansion and associated costs under scenarios that combine aggressive cost reductions and power sector decarbonization policy. Results will also be presented for the complementarity and economic value of wind-PV hybrids with varying amounts of energy storage.

complementarity↗

Exploring the dependence of gas cooling and heating functions on the incident radiation field with machine learning

ABSTRACT Gas cooling and heating functions play a crucial role in galaxy formation. But, it is computationally expensive to exactly compute these functions in the presence of an incident radiation field. These computations can be greatly sped up by using interpolation tables of pre-computed values, at the expense of making significant and sometimes even unjustified approximations. Here, we explore the capacity of machine learning to approximate cooling and heating functions with a generalized radiation field. Specifically, we use the machine learning algorithm XGBoost to predict cooling and heating functions calculated with the photoionization code cloudy at fixed metallicity, using different combinations of photoionization rates as features. We perform a constrained quadratic fit in metallicity to enable a fair comparison with traditional interpolation methods at arbitrary metallicity. We consider the relative importance of various photoionization rates through both a principal component analysis (PCA) and calculation of SHapley Additive exPlanation (shap) values for our XGBoost models. We use feature importance information to select different subsets of rates to use in model training. Our XGBoost models outperform a traditional interpolation approach at each fixed metallicity, regardless of feature selection. At arbitrary metallicity, we are able to reduce the frequency of the largest cooling and heating function errors compared to an interpolation table. We find that the primary bottleneck to increasing accuracy lies in accurately capturing the metallicity dependence. This study demonstrates the potential of machine learning methods such as XGBoost to capture the non-linear behaviour of cooling and heating functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic ground state of La 2 LiMoO 6 : A comparison with other Mo 5+ ( S=1/2 ) double perovskites

La 2 LiMoO 6 is a double perovskite (DP) with P2 1 /n symmetry based on the Mo5+ ion, 4d1, t2g1, S=1/2. It is isostructural with Sr 2 YMoO 6 , the magnetic ground state of which is apparently a very unusual collective spin singlet or valence-bond glass state as is the case for cubic (Fm-3m) Ba 2 YMoO 6 . Initial studies of La 2 LiMoO 6 suggested a different ground state from the other DPs but no clear conclusions could be drawn. A more detailed study is presented here including magnetic susceptibility, heat capacity, and elastic neutron-scattering results. This DP is now well characterized as an antiferromagnet, T N =18K, via observation of magnetic Bragg peaks in neutron scattering and an anomaly in the magnetic heat capacity. The ordering wave vector is k=( 1/21/2 0), consistent with a type I face-centered-cubic magnetic structure, and the ordered moment on Mo 5+ is 0.32(11)μ B , much reduced from the spin-only value of 1μ B . The index, f=|v c |/T N ~3, indicates a low level of frustration. The heat-capacity data above T N can be interpreted in terms of a one-dimensional spin-correlation model, as can the low-temperature data which follow a T 1 power law. This is consistent with an earlier suggestion. The difference with isostructural Sr 2 YMoO 6 is attributed to differences in the local distortion of the Mo–O octahedron and the resulting orbital ordering.

36 MATERIALS SCIENCE↗

A High‐Rate Li–CO 2 Battery Enabled by 2D Medium‐Entropy Catalyst

Abstract Lithium‐air batteries based on CO 2 reactant (Li–CO 2 ) have recently been of interest because it has been found that reversible Li/CO 2 electrochemistry is feasible. In this study, a new medium‐entropy cathode catalyst, (NbTa) 0.5 BiS 3 , that enables the reversible electrochemistry to operate at high rates is presented. This medium entropy cathode catalyst is combined with an ionic liquid‐based electrolyte blend to give a Li–CO 2 battery that operates at high current density of 5000 mA g −1 and capacity of 5000 mAh g −1 for up to 125 cycles, far exceeding reported values in the literature for this type of battery. The higher rate performance is believed to be due to the greater stability of the multi‐element (NbTa) 0.5 BiS 3 catalyst because of its higher entropy compared to previously used catalysts with a smaller number of elements with lower entropies. Evidence for this comes from computational studies giving very low surface energies (high surface stability) for (NbTa) 0.5 BiS 3 and transmission electron microscopystudies showing the structure being retained after cycling. In addition, the calculations indicate that Nb‐terminated surface promotes Li–CO 2 electrochemistry resulting in Li 2 CO 3 and carbon formation, consistent with the products found in the cell. These results open new direction to design and develop high‐performance Li–CO 2 batteries.

25 ENERGY STORAGE↗

Urban cells: Extending the energy hub concept to facilitate sector and spatial coupling

The rapid growth of urban areas and concerns over climate change make it vital to improve the energy sustainability of cities. Understanding the complex interactions within different sectors (sectoral) and localities (spatial) of cities plays a crucial role in improving efficiency and sustainability, which is extremely challenging due to the complex urban morphology. State-of-the-art energy concepts do not facilitate a detailed consideration of both sectoral and spatial coupling that energy infrastructure maintains at the urban scale. This has become a significant challenge when designing interconnected urban energy infrastructure. The Urban Cell concept is introduced to address this bottleneck. A novel computational model using a modular approach is introduced to create an interconnected urban infrastructure, including the energy, building, and transportation sectors. Optimal sizing of the distributed energy system (including renewables, energy storage, and dispatchable sources) and optimal urban morphology is determined within a modular unit. A game-theoretic approach is used to model the interactions between urban cells (modular units). The study revealed that the urban cell concept can reduce the net present value of the interconnected energy infrastructure by 37% while increasing the installed renewable energy capacity by 25%. This demonstrates the benefit potential of urban cells and the importance of considering interactions between different sectors and different parts within a city. The Urban Cell concept can be used to present the complex interactions maintained within a city.

Perera, ATD↗

Evaluation of the energy balance of chemical looping combustion of solid fuels using CuO-based oxygen carriers

Chemical looping combustion (CLC) can inherently capture the CO2 generated during thermal energy production. When using CuO-based oxygen carriers, the reactions in both the fuel reactor (FR) and air reactor (AR) are exothermic, facilitating autothermal operation. To prevent the oxygen carrier from becoming agglomerated while ensuring a sufficient oxygen release rate, it is necessary to predict the FR temperature and remove an appropriate amount of heat from the AR when burning high-rank fuels. Here in this work, the energy balance of a CuO-based CLC system firing various solid fuels (biomass, coal, and petroleum coke) was investigated by establishing a thermodynamic model using FactSage. The energy distribution characteristics of the FR were quantified based on a virtual five-step thermodynamic sequence. The effects of fuel properties, oxygen carrier properties, and operating conditions on the energy balance were evaluated systematically. The results indicate that the temperature difference between the FR and AR is not very sensitive to the heating value of the fuel, while the CuO loading of the oxygen carrier, the heat capacity of the support material, and the flow rate of the fluidizing gas have significant impact. The insights obtained in this work will help improve the design and heat management of CLC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field tunable magnetic transitions of CsCo 2 (MoO 4 ) 2 (OH): a triangular chain structure with a frustrated geometry

The sawtooth chain compound CsCo 2 (MoO 4 ) 2 (OH) is a complex magnetic system and here, we present a comprehensive series of magnetic and neutron scattering measurements to determine its magnetic phase diagram. The magnetic properties of CsCo 2 (MoO 4 ) 2 (OH) exhibit a strong coupling to the crystal lattice and its magnetic ground state can be easily manipulated by applied magnetic fields. There are two unique Co 2+ ions, base and vertex, with J bb and J bv magnetic exchange. The magnetism is highly anisotropic with the b-axis (chain) along the easy axis and the material orders antiferromagnetically at T N = 5 K. There are two successive metamagnetic transitions, the first at H c 1 = 0.2 kOe into a ferrimagnetic structure, and the other at H c 2 = 20 kOe to a ferromagnetic phase. Heat capacity measurements in various fields support the metamagnetic phase transformations, and the magnetic entropy value is intermediate between S = 3/2 and 1/2 states. The zero field antiferromagnetic phase contains vertex magnetic vectors (Co(1)) aligned parallel to the b-axis, while the base vectors (Co(2)) are canted by 34° and aligned in an opposite direction to the vertex vectors. The spins in parallel adjacent chains align in opposite directions, creating an overall antiferromagnetic structure. Further, at a 3 kOe applied magnetic field, adjacent chains flip by 180° to generate a ferrimagnetic phase. An increase in field gradually induces the Co(1) moment to rotate along the b-axis and align in the same direction with Co(2) generating a ferromagnetic structure. The antiferromagnetic exchange parameters are calculated to be J bb = 0.028 meV and J bv = 0.13 meV, while the interchain exchange parameter is considerably weaker at J ch = (0.0047/N ch ) meV. Our results demonstrate that the CsCo 2 (MoO 4 ) 2 (OH) is a promising candidate to study new physics associated with sawtooth chain magnetism and it encourages further theoretical studies as well as the synthesis of other sawtooth chain structures with different magnetic ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical properties investigation of tetragonal Ba T 2 P 2 (T = Ru, Pd)

The structural, thermal, electrical transport, and magnetic properties of ternary compounds BaT 2 P 2 (T = Ru, Pd) are reported together with electronic structure calculations. Our results show that BaRu 2 P 2 crystallises in the layered tetragonal ThCr 2 Si 2 -type structure (space group I4/mmm) whereas BaPd 2 P 2 adopts the primitive tetragonal CeMg 2 Si 2 -type structure (space group P4/mmm). The combined experimental results and electronic structure calculations suggest metallic and diamagnetic ground states for both materials. Electrical transport measurements further indicate non-Fermi liquid behaviour at low temperatures. Notably, BaRu 2 P 2 exhibits an anomalous feature in the magnetic susceptibility at T ~ 260 K, similar to that observed in BaRu 2 As 2 . A comparison between the bare density of states obtained from electronic structure calculations and the experimentally estimated values suggests the presence of strong correlation effects in the material. Furthermore, the heat capacity of BaPd 2 P 2 , calculated using the full phonon dispersion relation, is in good agreement with the experimental data, particularly at low temperatures, highlighting the significant contribution of optical phonon branches to C P in this temperature range.

flat bands↗

Agent-Based Simulation of Price-Demand Dynamics in Multi-Service Charging Station

As the adoption of electric vehicles and hydrogen fuel-cell vehicles grows, understanding how dynamic pricing strategies influence charging and refueling behaviors becomes crucial for optimizing local energy markets. This paper proposes a simulation-based analysis of a hydrogen-electricity integrated charging station that serves both types of vehicles. A multi-agent simulation framework is developed to model the interactions between vehicles and the station, incorporating price- and delay-sensitive behaviors in decision-making. The station can dynamically adjust energy prices, while vehicles optimize their charging or refueling choices based on their utility values. A series of sensitivity analyses are conducted to evaluate how electricity pricing, infrastructure capacity, and waiting behavior impact station performance. Results highlight that moderate electricity prices maximize user participation without sacrificing profit, infrastructure should be right-sized to demand to avoid over- or underutilization, and delay-toleration also affects service outcomes, which may reach the maximum service coverage at the threshold of 45 minutes.

Wang, Xudong [University of Tennessee, Knoxville (↗

Third-Party Aggregation Rulemaking in MISO and SPP Footprints

The report highlights key considerations for retail regulators in the footprints of the Southwest Power Pool (SPP) or Midcontinent Independent System Operator (MISO) in states that previously opted out of allowing third-party aggregation participation under FERC Order 719 and that may want to explore reversing the decision due to a changing policy environment under new FERC orders (i.e., 2222) and/or tightening resource adequacy constraints. Through a document review and a series of 27 interviews with regulators, aggregators, and other industry professionals, this document provides a high-level policy overview of the retail regulator’s role in a selection of processes, rules, and regulations to better understand how states have treated and/or integrated aggregators into wholesale markets. The report summarizes findings in two sections: General Findings and Specific Policy Findings. The General Findings offer high level takeaways such as the fact that 17 of the 20 states in MISO and SPP footprints opted out of third party aggregations following Order 719. Additionally, there is only one state that is fully restructured in the MISO and SPP footprints whereas the rest are vertically integrated, and the majority of third-party aggregations in the U.S. take place in restructured states outside of these footprints. Even so, third-party aggregations do take place in MISO and SPP albeit in small numbers and in an ad hoc regulatory environment. The specific policy findings delve deeper into specific examples of state actions on the topics of jurisdiction, registration and licensing, data governance, dual participation, and dispute resolution. Tables in each category organize state actions into Tiers I-III, which roughly correspond to the possible level of involvement or possible change necessary by state regulators and/or legislators to implement these actions. The tier level does not indicate any value judgement, as each state has respective regulatory limitations and each decision comes with various tradeoffs. One main tradeoff is between simplicity and quick implementation versus comprehensive and prolonged implementation. In many cases, actions in Tier I could be implemented without significant changes by relying on the use of existing processes for an aggregator context. On the other hand, many actions in Tier III are more narrowly designed to address aggregators specifically, but often require more significant changes including the involvement of additional parties through stakeholder engagement or legislative action. In some cases, these tiers are discrete. However, state regulators may also choose to progress through these various tiers sequentially as they phase in aggregators while learning from their experience. With the ability to stack bulk system level services, distributed energy resource aggregations in MISO and SPP could provide various private benefits (e.g., increased value streams to the owner) as well as societally beneficial grid services (e.g., peaking capacity, ancillary services, and other services that increase the grid’s overall operational efficiency). In deciding how to best to enable these benefits, states and retail regulators must weigh various tradeoffs if considering reversing a previous opt out.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗