Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Drop impact on hot plates: contact times, lift-off and the lamella rupture

When a liquid drop impacts on a heated substrate, it can remain deposited, or violently boil in contact, or lift off with or without ever touching the surface. The latter is known as the Leidenfrost effect. The duration and area of the liquid–substrate contact are highly relevant for the heat transfer, as well as other effects such as corrosion. However, most experimental studies rely on side view imaging to determine contact times, and those are often mixed with the time until the drop lifts off from the substrate. In this work, we develop and validate a reliable method of contact time determination using high-speed X-ray imaging and total internal reflection imaging. We exemplarily compare contact and lift-off times on flat silicon and sapphire substrates. We show that drops can rebound even without formation of a complete vapor layer, with a wide range of lift-off times. On sapphire, we find a local minimum of lift-off times that is much shorter than expected from capillary rebound in the comparatively low-temperature regime of transition boiling/thermal atomization. We elucidate the underlying mechanism related to spontaneous rupture of the lamella and receding of the contact area.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing growth of metal–organic frameworks with X-ray scattering and vibrational spectroscopy

Nucleation and crystallization arising from liquid to solid phase are involved in a multitude of processes in fields ranging from materials science to biology. Controlling the thermodynamics and kinetics of growth is advantageous to help tune the formation of complex morphologies. In this report, we harness wide-angle X-ray scattering and vibrational spectroscopy to elucidate the mechanism for crystallization and growth of the metal–organic framework Co-MOF-74 within microscopic volumes enclosed in a capillary and an attenuated total reflection microchip reactor. The experiments reveal molecular and structural details of the growth processes, while the results of plane wave density functional calculations allow identification of lattice and linker modes in the formed crystals. Synthesis of the metal–organic framework with microscopic volumes leads to monodisperse and micron-sized crystals, in contrast to those typically observed under bulk reaction conditions. Reduction in the volume of reagents within the microchip reactor was found to accelerate the reaction rate. The coupling of spectroscopy with scattering to probe reactions in microscopic volumes promises to be a useful tool in the synthetic chemist's kit to understand chemical bonding and has potential in designing complex materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into dual-functional modification for water stability enhancement of mesoporous zirconium metal–organic frameworks

The stability of metal–organic frameworks (MOFs) in water affects their ability to function as chemical catalysts, their capacity as adsorbents for separations in water vapor presence, and their usefulness as recyclable water harvesters. Here, we have examined water stability of four node-modified variants of the mesoporous MOF, NU-1000, namely formate-, Acac-, TFacac-, and Facac-NU-1000, comparing these with node-accessible NU-1000. These NU-1000 variants present ligands grafted to NU-1000's hexa-Zr(IV)-oxy nodes by displacing terminal aqua and hydroxo ligands. Facac-NU-1000, containing the most hydrophobic ligands, showed the greatest water stability, being able to undergo at least 20 water adsorption/desorption cycles without loss of water uptake capacity. Computational studies revealed dual salutary functions of installed Facac ligands: (1) enhancement of framework mechanical stability due to electrostatic interactions; and (2) transformation and shielding of the otherwise highly hydrophilic nodes from H-bonding interactions with free water, presumably leading to weaker channel-stressing capillary forces during water evacuation – consistent with trends in free energies of dehydration across the NU-1000 variants. Water harvesting and hydrolysis of chemical warfare agent simulants were examined to gauge the functional consequences of modification and mechanical stabilization of NU-1000 by Facac ligands. The studies revealed a harvesting capacity of ~1.1 L of water vapor per gram of Facac-NU-1000 per sorption cycle. They also revealed retention of catalytic MOF activity following 20 water uptake and release cycles. This study provides insights into the basis for node-ligand-engendered stabilization of wide-channel MOFs against collapse during water removal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystallization of nanopore-confined imidazolium ionic liquids probed by temperature-resolved in situ grazing-incidence wide angle X-ray scattering (GIWAXS)

The crystallization behavior of ionic liquids (ILs) 1-butyl-3-methylimidazolium [BMIM] hexafluorophosphate [PF 6 ] and chloride [Cl] is investigated upon confinement in 2.3 or 8.2 nm diameter silica nanopore arrays, along with the effects of covalently modifying the pore walls with 1-(3-trimethoxysilylpropyl)3-methylimidazolium [TMS-MIM] + groups. In situ grazing-incidence wide angle x-ray scattering (GIWAXS) is performed during heating from as low as -110 °C to room temperature. Partially ordered “nanodomains” are observed in both ILs in the bulk molten state, but they are disrupted by nanoconfinement. Melting point depression consistent with capillary effects is observed for [BMIM][PF 6 ] in 2.3 nm pores. However, the melting point is elevated for [BMIM][PF 6 ] in 8.2 nm pores, which provide sufficient space to stabilize the crystalline phase. For [BMIM][Cl], crystallization is observed only in 8.2 nm bare silica pores, but the melting point is severely depressed. Tethering with IL-like [TMS-MIM + ] also promotes the crystallization of [BMIM][PF 6 ], resulting in elevated melting points. The combined effects of a larger pore size and pore surface tethering on [BMIM][PF 6 ] result in a single stable crystal phase that persists from -140 °C to 25 °C (vs. the bulk melting point of -11 °C). These results show that when ILs are used in confined systems, complex crystallization behavior can emerge depending on the counterion, pore size, and surface modification that require consideration of ion layering in the confined space in addition to surface free energy effects.

He, Yuxin [University of Kentucky, Lexington, KY (↗

Wettability of ultra-small pores of carbon electrodes by size-asymmetric ionic fluids

Recently, we studied the phase behavior of ionic fluids under confinement using the classical density functional theory within the framework of the restricted primitive model. Additionally, the theoretical results indicate that narrowing the pore size may lead to a drastic reduction in the electric double layer capacitance, while increasing the surface electrical potential would improve the ionic accessibility of micropores. In this work, we extend the theoretical investigation to systems containing size-asymmetric electrolytes that may exhibit a vapor-liquid like phase transition in the bulk phase. The effects of pore size and surface electric potential on the phase diagram and microscopic structures of the confined electrolytes were studied over a broad range of parameters. We found that decreasing the pore size or increasing the surface potential could destabilize the liquid phase in micropores, and capillary evaporation could occur regardless of the size asymmetry between cations and anions. Compared to that in a symmetric ionic system, the vapor-liquid phase separation is more likely to take place as the size asymmetry becomes more pronounced. The phase transition would alter the “accessibility” of ions to micropores and lead to coexisting micropores with different surface charge densities as identified by Monte Carlo simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation furnace for synchrotron dark-field x-ray microscopy experiments

We present a multi-purpose radiation furnace designed for x-ray experiments at synchrotrons. The furnace is optimized specifically for dark-field x-ray microscopy (DFXM) of crystalline materials at beamline ID06 of the European Synchrotron Radiation Facility. The furnace can reach temperatures above 1200 °C with a thermal stability better than 10 °C, with heating and cooling rates up to 30 K/s. The non-contact heating design enables samples to be heated either in air or in a controlled atmosphere contained within a capillary tube. The temperature was calibrated via the thermal expansion of an α-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the radiation furnace. In the current configuration of the beamline, this furnace can be used for DFXM, near-field x-ray topography, bright-field x-ray nanotomography, high-resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure single crystal of aluminum.

Yildirim, C. (ORCID:0000000249690685)↗

Direct comparison of wire, foil, and hybrid X-pinches on a 200 kA, 150 ns current driver

Wire X-pinches (WXPs) have been studied comprehensively as fast (~1 ns pulse width), small (~1 μm) x-ray sources, created by twisting two or more fine wires into an “X” to produce a localized region of extreme magnetic pressure at the cross-point. Recently, two alternatives to the traditional WXP have arisen: the hybrid X-pinch (HXP), composed of two conical electrodes bridged by a thin wire or capillary, and the laser-cut foil X-pinch (LCXP), cut from a thin foil using a laser. We present a comparison of copper wire, hybrid, and laser-cut foil X-pinches on a single experimental platform: UC San Diego’s ~200 kA, 150 ns rise time GenASIS driver. All configurations produced 1–2 ns pulse width, ≤5 μm soft x-ray (Cu L-shell, ~1 keV) sources (resolutions diagnostically limited) with comparable fluxes. WXP results varied with linear mass and wire count, but consistently showed separate pinch and electron-beam-driven sources. LCXPs produced the brightest (~1 MW), smallest (≤5 μm) Cu K-shell sources, and spectroscopic data showed both H-like Cu K α lines indicative of source temperatures ≥2 keV, and cold K α (~8050 eV) characteristic of electron beam generated sources, which were not separately resolved on other diagnostics (within 1–2 ns and ≤200 μm). HXPs produced minimal K-shell emission and reliably single, bright, and small L-shell sources after modifications to shape the early current pulse through them. Benefits and drawbacks for each configuration are discussed to provide potential X-pinch users with the information required to choose the configuration best suited to their needs.

42 ENGINEERING↗

Prototype equation of state for phase transition of confined fluids based on the generalized van der Waals partition function

A simple self-consistent prototype equation of state (EOS) based on the Generalized van der Waals (vdW) partition function has been demonstrated to describe the phase transition of simple fluids in nanopores with uniform size. Different from those commonly presented in the literature, the new EOS does not need an auxiliary equation that is conventionally applied to provide the capillary pressure derived from surface tension. Lastly, the encouraging performance of the EOS calls for further extension to applications with more complex fluids and porous media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Droplet formation simulation using mixed finite elements

Droplet formation happens in finite time due to the surface tension force. The linear stability analysis is useful to estimate the size of a droplet but fails to approximate the shape of the droplet. This is due to a highly nonlinear flow description near the point where the first pinch-off happens. A one-dimensional axisymmetric mathematical model was first developed by Eggers and Dupont [“Drop formation in a one-dimensional approximation of the Navier–Stokes equation,” J. Fluid Mech. 262, 205–221 (1994)] using asymptotic analysis. This asymptotic approach to the Navier–Stokes equations leads to a universal scaling explaining the self-similar nature of the solution. Numerical models for the one-dimensional model were developed using the finite difference [Eggers and Dupont, “Drop formation in a one-dimensional approximation of the Navier–Stokes equation,” J. Fluid Mech. 262, 205–221 (1994)] and finite element method [Ambravaneswaran et al., “Drop formation from a capillary tube: Comparison of one-dimensional and two-dimensional analyses and occurrence of satellite drops,” Phys. Fluids 14, 2606–2621 (2002)]. The focus of this study is to provide a robust computational model for one-dimensional axisymmetric droplet formation using the Portable, Extensible Toolkit for Scientific Computation. The code is verified using the Method of Manufactured Solutions and validated using previous experimental studies done by Zhang and Basaran [“An experimental study of dynamics of drop formation,” Phys. Fluids 7, 1184–1203 (1995)]. The present model is used for simulating pendant drops of water, glycerol, and paraffin wax, with an aspiration of extending the application to simulate more complex pinch-off phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relative permeability as a stationary process: Energy fluctuations in immiscible displacement

Relative permeability is commonly used to model immiscible fluid flow through porous materials. In this work, we derive the relative permeability relationship from conservation of energy, assuming that the system to be non-ergodic at large length scales and relying on averaging in both space and time to homogenize the behavior. Explicit criteria are obtained to define stationary conditions: (1) there can be no net change for extensive measures of the system state over the time averaging interval; (2) the net energy inputs into the system are zero, meaning that the net rate of work done on the system must balance with the heat removed; and (3) there is no net work performed due to the contribution of internal energy fluctuations. Results are then evaluated based on direct numerical simulation. Dynamic connectivity is observed during steady-state flow, which is quantitatively assessed based the Euler characteristic. We show that even during steady-state flow at low capillary number ([Formula: see text]), typical flow processes will explore multiple connectivity states. The residence time for each connectivity state is captured based on the time-and-space average. The distribution for energy fluctuations is shown to be multi-modal and non-Gaussian when terms are considered independently. However, we demonstrate that their sum is zero. Given an appropriate choice of the thermodynamic driving force, we show that the conventional relative permeability relationship is sufficient to model the energy dissipation in systems with complex pore-scale dynamics that routinely alter the structure of fluid connected pathways.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prediction of hemiwicking dynamics in micropillar arrays

Dynamic hemiwicking behavior is observable in both nature and a wide range of industrial applications ranging from biomedical devices to thermal management. We present a semi-analytical modeling framework (without empirical fitting coefficients) to predict transient capillary-driven hemiwicking behavior of a liquid through a nano/microstructured surface, specifically a micropillar array. In our model framework, the liquid domain is discretized into micropillar unit cells to enable the time marching of the hemiwicking front. A simplified linear pressure drop is assumed along the hemiwicking length such that the local meniscus curvature, contact angle, and effective liquid height are determined at each time step in our transient model. This semi-analytical model is validated with experimental data from our own experiments and from published literature for different fluids. Our model predicts hemiwicking dynamics with <20% error over a broad range of micropillar geometries with height-to-pitch ratio ranging between ≈0.34 and 6.7 and diameter-to-pitch ratio in the range of ≈0.25–0.7 and without any fitting parameters. For lower diameter-to-pitch ratio data points related to sparse micropillar array arrangements, we suggest modifications to the semi-analytical model. This work sheds light on complex and dynamic solid–liquid–vapor interfacial interactions which could serve as a guide for the design of textured surfaces for wicking enhancement in multi-phase thermal and mass transport technologies and applications.

Mechanics↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Filament extension atomizers: A study of integration potential into spray dryers for high-viscosity and non-Newtonian fluids

Filament extension atomizers (FEAs) are an emerging class of spray nozzles designed to atomize high-viscosity and non-Newtonian fluids that are challenging for conventional pressure or two-fluid nozzles. In this study, we investigate the influence of roller geometry, surface velocity, roller material, and fluid rheology on the atomization performance of FEA systems using concentrated whey protein suspensions (50–70 wt. %). Extensional and shear rheology experiments, along with high-speed imaging and particle image velocimetry, reveal that filament breakup dynamics are governed by competition between inertial, capillary, and viscoelastic stresses. High roller rotational velocity leads to narrower spray cones, contradicting rheology experiments and suggests a significant inertial contribution to filament breakup. Smaller rollers operating at the same rotational velocity led to broader spray cones consistent with expectations. An FEA nozzle was integrated into a conventional dryer producing particles in the 100 μm range. Results suggest that FEA technology enables atomization of highly viscous fluids at industrially relevant spray cone angles similar to those generated by pressure nozzles, offering a pathway to improve energy efficiency in spray drying by enabling higher solids loading feedstocks. Furthermore, these insights provide critical guidance for optimizing FEA nozzle designs and process parameters across a range of applications.

Energy efficiency↗

Laser speckle contrast imaging of blood microcirculation in pancreatic tissues during laparoscopic interventions

Laser speckle contrast imaging of the microcirculatory bed of the pancreas is performed, which allows its condition to be assessed and thereby is an additional valuable tool for making a diagnostic decision and dynamically monitoring the effectiveness of the treatment for pathology of the abdominal organs. Laparoscopic operations on the pancreas are low-traumatic and in most cases avoid open surgical interventions. For the first time an experimental system for recording speckle images, combined with a commercially available five-millimetre rigid laparoscope, is presented. The sensitivity of the system to the fluid motion in a capillary at different velocities is determined, and the possibility of finding areas of blood microcirculation disturbance in modelling pancreatic ischemia in an experiment on laboratory animals is revealed. The laparoscope illumination channel is verified by comparison with speckle dynamics under external illumination of the studied object. (paper)

60 APPLIED LIFE SCIENCES↗

Hanging droplets from liquid surfaces

Natural and man-made robotic systems use the interfacial tension between two fluids to support dense objects on liquid surfaces. Here, we show that coacervate-encased droplets of an aqueous polymer solution can be hung from the surface of a less dense aqueous polymer solution using surface tension. The forces acting on and the shapes of the hanging droplets can be controlled. Sacs with homogeneous and heterogeneous surfaces are hung from the surface and, by capillary forces, form well-ordered arrays. Locomotion and rotation can be achieved by embedding magnetic microparticles within the assemblies. Direct contact of the droplet with air enables in situ manipulation and compartmentalized cascading chemical reactions with selective transport. Applications including functional microreactors, motors, and biomimetic robots are evident.

36 MATERIALS SCIENCE↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗

Reconfiguration of an Electrothermal-Arc Plasma Source for In Situ PMI Studies

An electrothermal-arc plasma source (ET-Arc) has been developed to produce transient plasma heat and particle fluxes similar to those produced by edge localized modes onto divertor plasma-facing components in tokamaks. The ET-Arc utilizes a capacitive discharge to send current through a 4-mm-diameter, 9-cm-long capillary source liner. The liner material is ablated to form a high-velocity plasma jet that impacts the target downstream. With the current discharge circuit configuration, pulse lengths are 1 to 2 ms in duration and deliver heat fluxes of 0.25 to 2.1 GW m-2. The plasma was previously characterized with optical emission spectroscopy (OES) on helium emission lines. The He I line ratios were interpreted with collisional radiative analysis to calculate ne and Te. The electron temperature and electron density ranged from Te = 1 to 5 eV and ne = 1022 to 1028 electrons/m3, respectively.

Lindquist, Elizabeth G.↗

Quantification of Changes in Fill Tube Curvature During Target Assembly

National Ignition Facility (NIF) targets used for inertial confinement fusion (ICF) experiments are precision-engineered assemblies composed of more than 100 components carefully and precisely assembled with accuracies no larger than a few micrometers in most cases. When individual components deviate from these strict specifications during the assembly process, they can induce target failure. An integral component essential to ICF targets is the capsule-fill-tube assembly. This assembly involves bonding the capsule to a fused silica tube less than 5 μm in thickness, through which the tritium and deuterium (T 2 + D 2 ) fuel mixture is injected into the capsule prior to the NIF shot. The filling tube is bonded to a larger fused silica capillary, about 130 μm in outer diameter, which is coated with a polymeric layer on the order of a 10-μm thickness or less. Only tubes exhibiting a deflection equivalent to less than 1% of their total length from a perfectly straight line are suitable for assembly. Slight curvatures on the order of 1 mm over 10 cm can induce unwanted stresses, potentially causing capsule misalignment and resulting in clogging or leaks during the filling process. Despite manually qualitatively sorting each tube for straightness prior assembly, it has been found that the treatments the tubes undergo once attached to the capsule can alter their curvature. Filling tubes that initially satisfy straightness tolerances can undergo geometric deformation, resulting in curvature deviations exceeding 1% of their total length and thus failing to meet target assembly requirements. Here, in this study, we propose a metric to assess the degree of curvature of the filling tubes and to gauge their changes in curvature caused by the standard thermal processing methods employed in target assembly. In addition, we suggest alternatives to mitigate tube curvature, ensuring they conform to specifications following assembly in the final targets.

Materials science↗