Search NASA⌕ Search

SEARCH · Search NASA

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Non-linear wave interaction in a magnetoplasma column. I - Theory. II Experiment

The paper presents an analysis of non-linear three-wave interaction for propagation along a cylindrical plasma column surrounded either by a metallic boundary, or by an infinite dielectric, and immersed in an infinite, static, axial magnetic field. An averaged Lagrangian method is used and the results are specialized to parametric amplification and mode conversion, assuming an undepleted pump wave. Computations are presented for a magneto-plasma column surrounded by free space, indicating that parametric growth rates of the order of a fraction of a decibel per centimeter should be obtainable for plausible laboratory plasma parameters. In addition, experiments on non-linear mode conversion in a cylindrical magnetoplasma column are described. The results are compared with the theoretical predictions and good qualitative agreement is demonstrated.

Larsen, J.-M.↗

Interstellar C IV and Si IV column densities toward early-type stars

Equivalent widths and deduced column densities of Si IV and C IV are examined for 18 early-type close binaries, and physical processes responsible for the origin of these ions in the interstellar medium are investigated. The available C IV/Si IV column density ratios typically lie within a narrow range from 0.8 to 4.5, and there is evidence that the column density of C IV is higher than that of N V along most lines of sight, suggesting that C IV is not formed in the same hot region as O VI. In addition, the existence of regions with a narrowly defined new temperature range around 50,000 deg K is indicated. The detection of the semitorrid gas of Bruhweiler, Kondo, and McCluskey (1978, 1979) is substantiated, and the relation of this gas to the observations of coronal gas in the galactic halo is discussed.

Bruhweiler, F. C.↗

Development of and fabrication of high resolution gas chromatographic capillary columns

Gas chromatographic columns which are used in the trace gas analyzer (TGA) for the space shuttle are coated with a polyoxyethylene lauryl ether. This stationary phase is of medium polarity and has a temperature limit of 160 C. A polymer for this application which has an improved thermal stability is investigated. The use of fused silica capillary columns with specially bonded phases as well as an introduction system (on column) was also studied.

Zlatkis, A.↗

Securing mechanism for the deployable column of the Hoop/Column antenna

The Column Longeron Latch (CLL) was designed and developed as the securing mechanism for the deployable, telescoping column of the Hoop/Column antenna. The column is an open lattice structure with three longerons as the principal load-bearing members. It is divided into telescoping sections that are deployed after the antenna is place in Earth orbit. The CLL provides a means to automatically lock the longeron sections into position during deployment as well as a means of unlocking the sections when the antenna is to be restowed. The CLL is a four bar linkage mechanism using the over center principle for locking. It utilizes the relative movement of the longeron sections to activate the mechanism during antenna deployment and restowing. The CLL design is one of the first mechanisms developed to meet the restowing requirements of spacecraft which will utilize the STS retrieval capability.

Ahl, E. L., Jr.↗

Radial dependence of HF wave field strength in the BPD column

The results of a recent set of RF frequency measurements of the beam plasma discharge (BPD) performed in order to determine a quantitative value for the field strength in the plasma frequency region of the spectrum are presented. The parallel and perpendicular components of the plasma wave electric fields inside the BPD column have comparable field strengths, on the order of 10 volts/m. The radial dependence of the field strength is very strong, decreasing by as much as 40 dB within one meter from the beam center, with the illumination or discharge column approximately one meter in diameter. The field strength inside the column increases as a function of distance along the beam at least for several meters from the gun aperture. The frequency and amplitude of the plasma wave increases with beam current. A particularly rapid increase in these parameters occurs as the beam current approaches the critical current.

Jost, R. J.↗

Direct coupling of microbore HPLC columns to MS systems

A detailed investigation using electron microscopy was conducted which examined the conditions of materials used in the construction of stable, high performance microbore liquid chromatography (LC) columns. Small details proved to be important. The effects of temperature on the elution of several homologous series used as probe compounds was examined in reverse phase systems. They showed that accessible temperature changes provide roughly half the increase in solvent strength that would be obtained going from a 100% aqueous to a 100% organic mobile phase, which is sufficient to warrant their use in many analyses requiring the use of gradients. Air circulation temperature control systems provide the easiest means of obtaining rapid, wide range changes in column temperature. However, slow heat transfer from the gas leads to thermal nonuniformity in the column and a decrease in resolution as the temperature program progresses.

Mcnair, H. M.↗

Atmospheric contributions to the column variance in direct-detection dial

One of the most important parameters of a Differential Absorption Lidar (DIAL) system is the delay time between the on and off resonant pulses. It is important that this delay time is sufficiently small to ensure that the atmosphere is effectively frozen between the pulses. Therefore, most Dial systems were designed with two lasers firing alternately less than 1 msec apart. Despite the importance of this parameter in the design of DIAL systems and its contribution to the overall error of a column measurement, very little is known about the size of the error for the case of a direct-detection system using atmospheric backscatter. The ultraviolet DIAL system uses two independent YAG/dye lasers and is therefore suitable for measuring the effects of different pulse delays on the variance of column measurements for a variety of atmospheric conditions. A set of DIAL returns were acquired with the two lasers tuned to the same wavelength and with a range of pulse delay times between 250 microseconds and several minutes. This data set was recorded in full on a computer and was used both to test different averaging techniques and also to evaluate atmospheric contributions to DIAL columns.

Milton, M. J. T.↗

Galactic interstellar abundance surveys with IUE. II - The equivalent widths and column densities

This paper continues a survey of interstellar densities, abundances, and cloud structure in the Galaxy, using the International Ultraviolet Explorer (IUE) satellite. Equivalent widths of 18 ultraviolet resonance transitions are presented and column densities for Si II, Mn II, Fe II, S II, and Zn II toward 261 early-type stars are derived. These equivalent widths and column densities agree within the stated errors of earlier Copernicus, BUSS, or IUE surveys of Mn II, Fe II, S II, and Zn II for 45 stars in common. The column densities are derived from single-component curves of growth with a common b-value based on that of Fe II and Si II.

Van Steenberg, Michael E.↗

Stratospheric column NO2 measurements from three Antarctic sites

The significance of stratospheric odd-nitrogen compounds in Antarctic ozone depletion studies has prompted an increase in Antarctic activities. Although several species are being studied, work has concentrated on the acquisition of NO2 data. Ground-based measurements of stratospheric column NO2 have been made at Arrival Heights, Antarctica, since spring 1982, with some gaps in the data base. Additional data has been acquired since February 1986 at Pole Station and Halley Bay, thus providing a chain of stations across the continent. The technique used is that of absorption spectroscopy in several wavelength regions, although here only those measurements are reported in the 430 to 450 nm region where strongly structured absorption been determined experimentally. However, theory features due to NO2 are identified in scattered sunlight in the zenith sky. Operation of a moon-tracking system at Arrival Heights has provided some additional data during the polar night. Previous analyses have shown that the NO2 column observed from the ground is strongly influenced by the season, and by the location of the site with respect to that of the polar vortex. The column amount correlates strongly with stratospheric temperature at about 70 mbar. The present data set further illustrates these features, and demonstrates both the strengths and qualifications apparent in the technique.

Keys, J. G.↗

Growth of single-crystal columns of CoSi2 embedded in epitaxial Si on Si(111) by molecular beam epitaxy

The codeposition of Si and Co on a heated Si(111) substrate is found to result in epitaxial columns of CoSi2 if the Si:Co ratio is greater than approximately 3:1. These columns are surrounded by an Si matrix which shows bulk-like crystalline quality based on transmission electron microscopy and ion channeling. This phenomenon has been studied as functions of substrate temperature and Si:Co ratio. Samples with columns ranging in average diameter from approximately 25 to 130 nm have been produced.

Fathauer, R. W.↗

Secular increase of the total vertical column abundance of carbon monoxide above central Europe since 1950

The secular increase of the total vertical column abundance of carbon monoxide has been derived from sets of infrared solar spectra recorded from an altitude of 3.58 km at the Jungfraujoch Station, Switzerland, in 1950-1951 and in 1985-1987. The results are based on equivalent width measurements of the R3 line of the 1-0 vibration-rotation band of (C-12)(0-16) at 2159.30/cm. The set of 1985-1987 observations indicates a strong seasonal cycle in the total column abundance of CO, with a + or - 25 percent modulation between minimum values in late summer and the maximum values in late winter. Variability on shorter time scales is also present in both the old and recent data sets. The mean cumulative rate of increase of the total column abundance of CO above the Jungfraujoch is found to be (0.85 + or - 0.20) percent/yr between 1950-1951 and 1985-1987. The present findings are compared with trends reported in earlier studies.

Zander, R.↗

Load-shortening behavior of an initially curved eccentrically loaded column

To explore the feasibility of using buckled columns to provide a soft support system for simulating a free-free boundary condition in dynamic testing, the nonlinear load-shortening behavior of initially imperfect, eccentrically loaded slender columns is analyzed. Load-shortening curves are obtained for various combinations of load eccentricity and uniform initial curvature and are compared, for reference purposes, with the limiting case of the classical elastica. Results for numerous combinations of initial curvature and load eccentricity show that, over a wide range of shortening, an axially loaded slender column exhibits load-deflection compliance which is of the same order as that of a straight but otherwise identical cantilever beam under lateral tip loading.

Fichter, W. B.↗

Thermocapillary flow and natural convection in a melt column with an unknown melt/solid interface

A vertical melt column set up between an upper heating rod and a lower sample rod, i.e., the so-called half-zone system, is a convenient experimental tool for studying convection in the melt in floating-zone crystal growth. In order to help understand the convection observed in the melt column, a computer model has been developed to describe steady state, axisymmetrical thermocapillary flow and natural convection in the melt. The governing equations and boundary conditions are expressed in general non-orthogonal curvilinear coordinates in order to accurately treat the unknown melt/solid interface as well as all other physical boundaries in the system. The effects of key dimensionless variables on the following items are discussed: (1) convection and temperature distribution in the melt; (2) the shape of the melt/solid interface; (3) the height of the melt column. These dimensionless variables are the Grashof, Marangoni and Prandtl numbers.

Lan, C. W.↗

Seasonal cycle and secular trend of the total and tropospheric column abundance of ethane above the Jungfraujoch

The secular trend and the seasonal cycle of the total and the tropospheric column abundances of C2H6 over the Jungfraujoch Station (Switzerland) were deduced from infrared solar spectra recorded in 1951 and from 1984 to 1988. Results show a definite seasonal variation in the total vertical column abundance of C2H6, with a maximum of (1.43 + or - 0.03) x 10 to the 16th molecules/sq cm during March and April and a minimum in the fall; the ratio between the maximum and the minimum column abundances was found to be 1.62 + or - 0.11. The secular trend in the tropospheric burden above the Jungfraujoch was found to be (0.85 + or - 0.3) percent/yr.

Ehhalt, D. H.↗

Infrared measurements of HF and HCl total column abundances above Kitt Peak, 1977-1990 - Seasonal cycles, long-term increases, and comparisons with model calculations

The paper deals with hydrogen-chloride and hydrogen-fluoride total column measurements, their estimated long-term rates of increase, seasonal cycles, and variability, deduced from the analysis of a set of high-resolution infrared solar spectra recorded at Kitt Peak. The Kitt Peak observations and methods of analysis are described, the results are presented and compared with previously reported measurements and trends. The data is analyzed by using a multilayer nonlinear least-squares spectral fitting procedure and a consistent set of spectroscopic line parameters. Model-calculated hydrogen-chloride and hydrogen-fluoride total columns obtained with a two-dimensional model are discussed, and the model results are compared with the measured hydrogen-chloride and hydrogen-fluoride total columns, seasonal cycles, and trends. It is pointed out that the observed trends of both molecules are in satisfactory agreement with the model results calculated from emission histories and photooxidation rates for the source molecules.

Rinsland, C. P.↗

A photoautotrophic source for lycopane in marine water columns

Suspended particulate matter and recent sediments from diverse oceanic sites have been investigated for their contents of lycopane. Lycopane was present in all samples, including both oxic and anoxic water column and sediments. The highest concentrations in the water column were found in surface waters of the central Pacific gyre (1.5 ng/L) and in the anoxic waters of the Cariaco Trench (1.1 ng/L) and the Black Sea (0.3 ng/L). Vertical concentration profiles suggest that lycopane is probably algal in origin. Moreover, biogeochemical conditions in anoxic zones apparently result in a secondary production of lycopane from an as yet unidentified precursor. Compound-specific carbon isotopic analyses have been carried out on lycopane from water column and sediment samples. Isotopic compositions of lycopane range between -23.6 and -32.9 percent and are consistent with a photoautotrophic origin. We postulate that some lycopane is produced in surface waters of the ocean, while additional lycopane is produced in anoxic zones by anaerobic microbial action on an algal precursor.

Wakeham, Stuart G.↗

Measurements and model calculations of HCl column amounts and related parameters over McMurdo during the austral spring in 1989

Solar spectra obtained from a ground-based Fourier transform infrared instrument at McMurdo (Antarctica) in the spring of 1989 have been analyzed to determine total HCl column amounts. A one-dimensional photochemical model was used to simulate the rate of recovery of HCl in the springtime. Low column amounts (about 1 x 10 exp 15 molecules/sq cm) were observed in early September and may be attributed to the heterogeneous conversion of HCl to active chlorine species during the polar night. The rate of recovery of HCl is consistent with its production by chlorine atoms reacting with methane and is dependent on concentrations of active chlorine species and NO molecules in the altitude region from 12 to 22 km. High HCl column amounts (about 7 x 10 exp 15 molecules/sq cm) were observed following recovery in late October, suggesting that the lower stratosphere in the polar region had descended relative to mid-latitudes and that the degree of dechlorination of the transported air was very small.

Liu, X.↗

Fluid column stability in the presence of periodic accelerations

The interface stability of fluid columns in the presence of a periodic acceleration field with a component normal to the longitudinal axis of the isothermal cylinder was investigated. Floquet theory was used in the investigation and the column was taken as infinite. The finite length case was also studied and axisymmetric and nonaxisymmetric oscillations were considered. Results for the infinite length case were good approximations to those for the finite length column.

Lyell, M. J.↗