Search NASA⌕ Search

SEARCH · Search NASA

Results for “computation time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Numerical investigations in three-dimensional internal flows

An investigation into the use of computational fluid dynamics (CFD) was performed to examine the expected heat transfer rates that will occur within the NASA-Ames 100 megawatt arc heater nozzle. This nozzle was tentatively designed and identified to provide research for a directly connected combustion experiment specifically related to the National Aerospace Plane Program (NASP) aircraft, and is expected to simulate the flow field entering the combustor section. It was found that extremely fine grids, that is very small mesh spacing near the wall, are required to accurately model the heat transfer process and, in fact, must contain a point within the laminar sublayer if results are to be taken directly from a numerical simulation code. In the present study, an alternative to this very fine mesh and its attendant increase in computational time was invoked and is based on a wall-function method. It was shown that solutions could be obtained that give accurate indications of surface heat transfer rate throughout the nozzle in approximately 1/100 of the computer time required to do the simulation directly without the use of the wall-function implementation. Finally, a maximum heating value in the throat region of the proposed slit nozzle for the 100 megawatt arc heater was shown to be approximately 6 MW per square meter.

Rose, William C.↗

Assessment of a parabolic analysis for axisymmetric internal flows in rocket and turbomachinery ducts

The flow paths in gas turbine passages encompass a wide range of flow properties such as Reynolds number and Mach number as well as many other variable flow conditions such as swirl, free-stream turbulence, and laminar/turbulent transition. An existing computer program, the Axisymmetric Diffuser Duct (ADD) code, which calculates compressible, turbulent, swirling flow through axisymmetric ducts has been modified to include the effects of free-stream turbulence and laminar/turbulent transition. The program has been evaluated on a matrix of test cases to determine its accuracy, robustness, and limits of applicability. This improved version of the ADD code calculates solutions which compare well with available data and can now be applied to a wider range of problems than previously possible. In addition a concept called local enhancement was developed and tested on a simple two-dimensional geometry in order to demonstrate a method to reduce computer time. In this concept the pressure distribution is calculated on a coarse grid using the ADD code and the viscous layer is locally enhanced using a boundary layer analysis. By applying this concept, an order of magnitude reduction in computer time was possible without any loss in accuracy.

Power, G. D.↗

Design of the VISITOR Tool: A Versatile ImpulSive Interplanetary Trajectory OptimizeR

The design of trajectories for interplanetary missions represents one of the most complex and important problems to solve during conceptual space mission design. To facilitate conceptual mission sizing activities, it is essential to obtain sufficiently accurate trajectories in a fast and repeatable manner. To this end, the VISITOR tool was developed. This tool modularly augments a patched conic MGA-1DSM model with a mass model, launch window analysis, and the ability to simulate more realistic arrival and departure operations. This was implemented in MATLAB, exploiting the built-in optimization tools and vector analysis routines. The chosen optimization strategy uses a grid search and pattern search, an iterative variable grid method. A genetic algorithm can be selectively used to improve search space pruning, at the cost of losing the repeatability of the results and increased computation time. The tool was validated against seven flown missions: the average total mission (Delta)V offset from the nominal trajectory was 9.1%, which was reduced to 7.3% when using the genetic algorithm at the cost of an increase in computation time by a factor 5.7. It was found that VISITOR was well-suited for the conceptual design of interplanetary trajectories, while also facilitating future improvements due to its modular structure.

Corpaccioli, Luca↗

Faster Antenna Noise Temperature Calculations Using a Novel Approximation Technique

In order to properly tradeoff the various antenna and feed configurations for the Square Kilometre Array (SKA) optical design it is necessary to evaluate the gain and noise temperature of each configuration over a wide range of frequencies. German Cortes describes the standard technique for computing antenna noise temperature. However, since the total antenna pattern needs to be calculated over the entire 4 pi steradians at a fine enough resolution to accurately include the main beam, the computer time required is enormous. Even at modest frequencies and reflector sizes (approximately 5 to 10 GHz for a 12 meter main reflector) the technique can take days on a single node of a supercomputer. Utilizing the standard technique to compute the noise temperature for all the cases required to properly characterize the SKA design is clearly not feasible. At least a 100 to 1000 speedup in the computation time is required. This paper describes an approximation technique that can accomplish this improvement with extremely small errors in noise temperature calculation of a few tenths of Kelvin.

Reflector Antennas↗

A High-Performance Computing Predictive GNSS Performance Monitor for Autonomous Air Vehicles in Urban Environments

This report offers analysis and design insights for leveraging High-Performance Computing (HPC) to predict line-of-sight (LOS) Global Navigation Satellite System (GNSS) availability in a city. This work is motivated by the emerging fields of Advanced and Urban Air Mobility (AAM/UAM), where regulatory authorities are seeking city-scale, meter-resolution risk forecasting in order to safely integrate new flight missions with existing urban life and infrastructure. This work addresses the technical challenge of efficiently computing urban GNSS satellite visibility to predict GNSS performance metrics under these requirements. We present a new HPC-optimized shadow casting algorithm variant as a ray-based approach to forecasting satellite visibility. We apply this algorithm variant in a software-defined prognostic service which generates a GNSS navigation risk-correlated map as a path planning-style potential field. We detail dominant computational burdens, viable simplifying assumptions, and different algorithmic implementations, intending to demonstrate a baseline of computation time needed by each stage in such a service. We conclude by analyzing the prototype service’s prediction accuracy compared to receiver data from Corpus Christi, Texas. This informs design trade-offs along the dimensions of hardware, computation time, and tolerable forecasting error (including proportions of false positives and false negatives).

GNSS↗

RESOLVING THE ELECTROCHEMICAL EQUATIONS OF A SOLID OXIDE FUEL CELL FOR USE IN TRANSIENT SIMULATION AND INTEGRATION INTO CYBER-PHYSICAL SYSTEMS

A major challenge with complex cyber-physical systems stems from long model computational time that creates a mismatch between the model system and the physical system. The numerical modeling of solid oxide fuel cells (SOFCs) presents particular challenges due to the highly coupled nature of the underlying equations and the multiphysics needed to fully resolve their behavior during a transient event. To this end current approaches revolve around splitting the computational efforts into resolving temperature effects and resolving electrochemical effects. Current methods employed for the transient simulation of an SOFC for implementation in the Hybrid Performance (HyPer) facility cyberphysical plant at the National Energy Technology Laboratory reveal a distinct need for accelerated results with a high degree of stability. To this aim, an investigation into the computational time for the code reveals that the underlying electrochemical algorithm takes an order of magnitude more time than its thermal counterpart and has a tendency to vary in terms of iteration time and as such a rework of the underlying system is proposed. The primary method for accelerated electrochemical algorithm solutions is to employ higher order root finding recipes for the resolution of the highly coupled electrochemical equations. This is done with the intention to reduce the overall number of subiterations necessary for resolving voltage, current density, and species concentration, properties of the fuel cell that are all directly coupled and require nested iterative approaches. The overall objective of this approach is an order of magnitude reduction in calculation time without sacrificing stability and increasing accuracy. Specific approaches involve using both bounded and unbounded techniques, such as the False Position method and the Secant method (or if applicable Newton-Raphson) respectively, the drawbacks being slower convergence for False Position and instability for the Secant or Newton-Raphson methods. Current preliminary results on simplified versions of the parent functions involved for electrochemical calculations indicate a reduction in computational steps by a factor of two for the secant method and a factor of three for Newton-Raphson. When implemented into new modified electrochemical algorithms, the results indicate a possible order of magnitude reduction in calculation time.

Arias, Jesus↗

Simulation and Flight Test Capability for Testing Prototype Sense and Avoid System Elements

NASA Langley Research Center (LaRC) and The MITRE Corporation (MITRE) have developed, and successfully demonstrated, an integrated simulation-to-flight capability for evaluating sense and avoid (SAA) system elements. This integrated capability consists of a MITRE developed fast-time computer simulation for evaluating SAA algorithms, and a NASA LaRC surrogate unmanned aircraft system (UAS) equipped to support hardware and software in-the-loop evaluation of SAA system elements (e.g., algorithms, sensors, architecture, communications, autonomous systems), concepts, and procedures. The fast-time computer simulation subjects algorithms to simulated flight encounters/ conditions and generates a fitness report that records strengths, weaknesses, and overall performance. Reviewed algorithms (and their fitness report) are then transferred to NASA LaRC where additional (joint) airworthiness evaluations are performed on the candidate SAA system-element configurations, concepts, and/or procedures of interest; software and hardware components are integrated into the Surrogate UAS research systems; and flight safety and mission planning activities are completed. Onboard the Surrogate UAS, candidate SAA system element configurations, concepts, and/or procedures are subjected to flight evaluations and in-flight performance is monitored. The Surrogate UAS, which can be controlled remotely via generic Ground Station uplink or automatically via onboard systems, operates with a NASA Safety Pilot/Pilot in Command onboard to permit safe operations in mixed airspace with manned aircraft. An end-to-end demonstration of a typical application of the capability was performed in non-exclusionary airspace in October 2011; additional research, development, flight testing, and evaluation efforts using this integrated capability are planned throughout fiscal year 2012 and 2013.

Howell, Charles T.↗

Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer

Purpose: To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Methods: Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. Results: The results from AXB and XVMC agreed with measurements within ±3.0% for the lung-equivalent phantom with a 6 × 6 cm{sup 2} field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ±3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124–358 s), 66.1 ± 16.0 s (range, 42–94 s), and 6.7 ± 1.1 s (range, 5–9 s) for XVMC, AXB, and AAA, respectively. Conclusions: In the phantom evaluations, AXB and XVMC agreed better with measurements than did AAA. Calculations differed in the density-changing zones (substance boundaries) between AXB/XVMC and AAA. In the lung SBRT cases, a comparative analysis of dose-volumetric data and dose distributions with XVMC demonstrated that the AXB provided better agreement with XVMC than AAA. The computation time of AXB was faster than that of XVMC; therefore, AXB has better balance in terms of the dosimetric performance and computation speed for clinical use than XVMC.

60 APPLIED LIFE SCIENCES↗

Mesh Adaptive Search Optimization in SERPENT2 Stereolithography Geometry

SERPENT2 Monte Carlo program has the capability to model reactor cores by stereolithography (STL) geometry. In this geometry, volumes are defined by the union of triangulated surfaces. Using the STL geometry offers unique benefits, including: 1) the model can be printed on 3D printers; 2) the possibility to use directly geometrical models from Computer-Aided Design (CAD); 3) the capability to perform multi-physics simulations coupling neutronics, thermal-hydraulics, and material science computations. In this work the STL geometry has been created by the CUBIT software, which is designed for finite elements mesh generation. The materials in the STL geometry have been assigned by a simple C program using the colors of the volumes in the CUBIT model. The goal of this work is to minimize the SERPENT2 computing time using mesh adaptive search algorithms. The basic idea is to split the geometry of the core into two zones: one zone containing the fuel elements (including the moderator and the coolant) and the other containing the reflector (and the target zone of the core, if it is driven by an external neutron source). By performing this splitting, two separate meshes are used, which results in a considerable computing time saving. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Organic scintillation detector response simulation using non-analog MCNPX-PoliMi

Organic liquid scintillation detectors are valuable for the detection of special nuclear material since they are capable of detecting both neutrons and gamma rays. Scintillators can also provide energy information which is helpful in identification and characterization of the source. In order to design scintillation based measurement systems appropriate simulation tools are needed. MCNPX-PoliMi is capable of simulating scintillation detector response; however, simulations have traditionally been run in analog mode which leads to long computation times. In this paper, non-analog MCNPX-PoliMi mode which uses variance reduction techniques is applied and tested. The non-analog MCNPX-PoliMi simulation test cases use source biasing, geometry splitting and a combination of both variance reduction techniques to efficiently simulate pulse height distribution and then time-of-flight for a heavily shielded case with a {sup 252}Cf source. An improvement factor (I), is calculated for distributions in each of the three cases above to analyze the effectiveness of the non-analog MCNPX-PoliMi simulations in reducing computation time. It is found that of the three cases, the last case which uses a combination of source biasing and geometry splitting shows the most improvement in simulation run time for the same desired variance. For pulse height distributions speedup ranging from a factor 5 to 25 is observed, while for time-of-flights the speedup factors range from 3 to 10. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Poster — Thur Eve — 44: Linearization of Compartmental Models for More Robust Estimates of Regional Hemodynamic, Metabolic and Functional Parameters using DCE-CT/PET Imaging

Quantitative analysis of dynamic positron emission tomography (PET) data usually involves minimizing a cost function with nonlinear regression, wherein the choice of starting parameter values and the presence of local minima affect the bias and variability of the estimated kinetic parameters. These nonlinear methods can also require lengthy computation time, making them unsuitable for use in clinical settings. Kinetic modeling of PET aims to estimate the rate parameter k{sub 3}, which is the binding affinity of the tracer to a biological process of interest and is highly susceptible to noise inherent in PET image acquisition. We have developed linearized kinetic models for kinetic analysis of dynamic contrast enhanced computed tomography (DCE-CT)/PET imaging, including a 2-compartment model for DCE-CT and a 3-compartment model for PET. Use of kinetic parameters estimated from DCE-CT can stabilize the kinetic analysis of dynamic PET data, allowing for more robust estimation of k{sub 3}. Furthermore, these linearized models are solved with a non-negative least squares algorithm and together they provide other advantages including: 1) only one possible solution and they do not require a choice of starting parameter values, 2) parameter estimates are comparable in accuracy to those from nonlinear models, 3) significantly reduced computational time. Our simulated data show that when blood volume and permeability are estimated with DCE-CT, the bias of k{sub 3} estimation with our linearized model is 1.97 ± 38.5% for 1,000 runs with a signal-to-noise ratio of 10. In summary, we have developed a computationally efficient technique for accurate estimation of k{sub 3} from noisy dynamic PET data.

60 APPLIED LIFE SCIENCES↗

A deep learning-guided automated workflow in LipidOz for detailed characterization of fungal fatty acid unsaturation by ozonolysis

Understanding fungal lipid biology and metabolism is critical for antifungal target discovery as lipids play central roles in cellular processes. Nuances in lipid structural differences can significantly impact their functions, making it necessary to characterize lipids in detail to enable and understanding of their roles in these complex systems. In particular, lipid double bond (DB) locations are an important component of lipid structure that can only be determined using a few specialized analytical techniques. Ozone-induced dissociation mass spectrometry (OzID-MS) is one such technique that uses ozone to break lipid DBs, producing pairs of characteristic fragments that allow the determination of DB positions. In this work we apply OzID-MS and LipidOz software to analyze the complex lipids of Saccharomyces cerevisiae yeast strains transfected with different fatty acid desaturases from Histoplasma capsulatum to determine the specific unsaturated lipids produce. The automated data analysis in LipidOz made the determination of DB positions from this large dataset more practical, but manual verification for all targets was still time-consuming. The DL model reduces manual involvement in data analysis, but since it was trained using mammalian lipid extracts, the prediction accuracy on yeast-derived data was reduced. We addressed both shortcomings by retraining the DL model to act as a pre-filter to prioritize targets for automated analysis, providing confident manually verified results but requiring less computational time and manual effort. Our workflow resulted in the determination of novel DB positions and enzymatic specificity.

mass spectrometry, deep learning, Lipidomics, doub↗

Discrete-State Simulated Annealing For Traveling-Wave Tube Slow-Wave Circuit Optimization

Algorithms based on the global optimization technique of simulated annealing (SA) have proven useful in designing traveling-wave tube (TWT) slow-wave circuits for high RF power efficiency. The characteristic of SA that enables it to determine a globally optimized solution is its ability to accept non-improving moves in a controlled manner. In the initial stages of the optimization, the algorithm moves freely through configuration space, accepting most of the proposed designs. This freedom of movement allows non-intuitive designs to be explored rather than restricting the optimization to local improvement upon the initial configuration. As the optimization proceeds, the rate of acceptance of non-improving moves is gradually reduced until the algorithm converges to the optimized solution. The rate at which the freedom of movement is decreased is known as the annealing or cooling schedule of the SA algorithm. The main disadvantage of SA is that there is not a rigorous theoretical foundation for determining the parameters of the cooling schedule. The choice of these parameters is highly problem dependent and the designer needs to experiment in order to determine values that will provide a good optimization in a reasonable amount of computational time. This experimentation can absorb a large amount of time especially when the algorithm is being applied to a new type of design. In order to eliminate this disadvantage, a variation of SA known as discrete-state simulated annealing (DSSA), was recently developed. DSSA provides the theoretical foundation for a generic cooling schedule which is problem independent, Results of similar quality to SA can be obtained, but without the extra computational time required to tune the cooling parameters. Two algorithm variations based on DSSA were developed and programmed into a Microsoft Excel spreadsheet graphical user interface (GUI) to the two-dimensional nonlinear multisignal helix traveling-wave amplifier analysis program TWA3. The algorithms were used to optimize the computed RF efficiency of a TWT by determining the phase velocity profile of the slow-wave circuit. The mathematical theory and computational details of the DSSA algorithms will be presented and results will be compared to those obtained with a SA algorithm.

Wilson, Jeffrey D.↗

A hyperbolic-equation system approach for magnetized electron fluids in quasi-neutral plasmas

A new approach using a hyperbolic-equation system (HES) is proposed to solve for the electron fluids in quasi-neutral plasmas. The HES approach avoids treatments of cross-diffusion terms which cause numerical instabilities in conventional approaches using an elliptic equation (EE). A test calculation reveals that the HES approach can robustly solve problems of strong magnetic confinement by using an upwind method. The computation time of the HES approach is compared with that of the EE approach in terms of the size of the problem and the strength of magnetic confinement. The results indicate that the HES approach can be used to solve problems in a simple structured mesh without increasing computational time compared to the EE approach and that it features fast convergence in conditions of strong magnetic confinement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MCTP system model based on linear programming optimization of apertures obtained from sequencing patient image data maps

Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.

60 APPLIED LIFE SCIENCES↗

Application of the TITAN Hybrid Deterministic Transport Code to Medical Physics - Paper 118

The TITAN code is a 3-dimensional parallel deterministic transport code that solves the linear Boltzmann equation. The TITAN code has hybrid algorithms that are ideal for medical physics applications: i) SN and characteristics method and ii) SN with a fictitious quadrature set and ray-tracing. These hybrid algorithms have been used in the simulation of computed tomography (CT) and single photon emission computed tomography (SPECT) In this paper, the hybrid algorithms developed for medical physics applications in the TITAN code are discussed. First, the TITAN code's block-oriented approach for utilizing SN and characteristic solvers for CT is presented and results for a simple test case are given. Second, the paper describes a hybrid formulation for SPECT with an SN solver in the phantom, a fictitious quadrature set for directions from the phantom surface passing through the collimator, and a simplified ray-tracing algorithm for particle transport to the detector. Finally, ongoing work is described and concluding remarks are given. The TITAN code's hybrid algorithms allow it to efficiently solve problems with low-scatter regions, which are frequently found in medical physics applications. The TITAN code has been used to solve a simplified CT problem and generate projection images for SPECT simulations. The WCOS technique was developed to improve the TITAN code's collimator representation. For these applications, the TITAN code was shown to require significantly less computation time than MCNP5. Work is currently underway to implement an iterative image reconstruction algorithm in the TITAN code. A script that calls the TITAN code to complete the forward projection step in SPECT has already been used to reconstruction a 2-dimensional phantom. The ability of TITAN to fully model particle transport in the patient in short computation times is expected to be a great advantage to iterative reconstruction. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Configuring Airspace Sectors with Approximate Dynamic Programming

In response to changing traffic and staffing conditions, supervisors dynamically configure airspace sectors by assigning them to control positions. A finite horizon airspace sector configuration problem models this supervisor decision. The problem is to select an airspace configuration at each time step while considering a workload cost, a reconfiguration cost, and a constraint on the number of control positions at each time step. Three algorithms for this problem are proposed and evaluated: a myopic heuristic, an exact dynamic programming algorithm, and a rollouts approximate dynamic programming algorithm. On problem instances from current operations with only dozens of possible configurations, an exact dynamic programming solution gives the optimal cost value. The rollouts algorithm achieves costs within 2% of optimal for these instances, on average. For larger problem instances that are representative of future operations and have thousands of possible configurations, excessive computation time prohibits the use of exact dynamic programming. On such problem instances, the rollouts algorithm reduces the cost achieved by the heuristic by more than 15% on average with an acceptable computation time.

Bloem, Michael↗