Search NASA⌕ Search

SEARCH · Search NASA

Results for “default”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

UPC++ v1.0 Programmer’s Guide, Revision 2021.9.0

UPC++ is a C++ library that provides Partitioned Global Address Space (PGAS) programming. It is designed for writing parallel programs that run efficiently and scale well on distributed-memory parallel computers. The PGAS model is single program, multiple-data (SPMD), with each separate constituent process having access to local memory as it would in C++. PGAS additionally provides one-sided Remote Memory Access (RMA) to a global address space, which is allocated in shared segments that are distributed over the processes. UPC++ also features Remote Procedure Call (RPC) communication, making it easy to move computation to operate on data that resides on remote processes. In UPC++, all communication operations are explicit, which encourages programmers to be aware of the cost of communication and data movement. Moreover, all communication operations are asynchronous by default, to enable programmers to write code that scales well even on hundreds of thousands of cores.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

UPC++ v1.0 Specification, Revision 2021.9.0

UPC++ is a C++ library providing classes and functions that support Partitioned Global Address Space (PGAS) programming. The key communication facilities in UPC++ are one-sided Remote Memory Access (RMA) and Remote Procedure Call (RPC). All communication operations are syntactically explicit and default to non-blocking; asynchrony is managed through the use of futures, promises and continuation callbacks, enabling the programmer to construct a graph of operations to execute asynchronously as high-latency dependencies are satisfied. A global pointer abstraction provides system-wide addressability of shared memory, including host and accelerator memories. The parallelism model is primarily process-based, but the interface is thread-safe and designed to allow efficient and expressive use in multi-threaded applications. The interface is designed for extreme scalability throughout, and deliberately avoids design features that could inhibit scalability.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) - Beta Version [Slides]

Due to high fossil fuel imports, high electricity rates, an unreliable electricity grid, and 100% renewable electricity goals, demand response can play a crucial role for the Puerto Rico electricity grid. The Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) is a spreadsheet-based tool in which users can estimate the potential impacts of demand response, energy efficiency, and VRE and storage adoption in Puerto Rico from 2021 through 2040. The tool includes projections for solar, wind, and battery adoption based on released RFPs and energy targets (including Act-17 2019) to generate a projected net load profile for each hour through 2040. Based on user inputs and default assumptions, the tool also projects load profile impacts of demand response and energy efficiency, and is specifically focused on highlighting projected demand response technical potential. This demand response technical potential can be used by local utilities, regulators, program administrators, or researchers to help design demand response programs for larger impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The False Dilemma: Rethinking AF Science and Technology Officer Talent Management

In 2019, Secretary of the Air Force (SECAF) Heather Wilson launched the 2030 Science and Technology (S&T) Strategy by stating, “The advantage will go to those who create the best technologies and who integrate and field them in creative operational ways that provide military advantages.” In 2021, 15% of Air Force general officers responsible for creating and integrating this technological edge had a science, technology, engineering, and math (STEM) graduate degree, and less than 1% of generals had a STEM doctorate. As one point of comparison, at least 32% and 13% of founding CEOs of Fortune 500 technology companies had a master’s and doctoral STEM degree, respectively. The gulf is larger when you consider that these CEOs used their technical degrees throughout their careers whereas most general officers do not. In large organizations, if the leader does not possess technical knowledge, it is difficult to drive innovation systems and connect ideas to reality. The evidence for this disconnect is abundant in acquisition challenges for high-tech systems, significant pushback to the “revolution in military affairs”, and failure of the “Third Offset” to take hold and deliver capabilities to offset Chinese and Russian capabilities. Indeed, when the former Air Force and Space Force Chief Software Officer, Nicolas M. Chaillan, offered his resignation, one of the main reasons for leaving was “the failure of OSD and the Joint Staff to deliver on their own alleged top ‘priority’, JADC2 – they couldn’t ‘walk the walk.’” Senior leaders have recognized this disconnect, and several inquiries and studies regarding STEM competency have been conducted. Many have posed a false dilemma: a large, STEM-cognizant or small, STEM-expert force. However, current and future STEM human capital needs are managed at the unit and functional area level. This leads to “silos” and the tactical “needs of the present” dominating the strategic “needs of the future”, highlighted by only two functional areas systematically tracking future STEM needs. Therefore, the decision on force structure appears to have been historically made by default through these and other perceived structural realities, and a vast majority of recommendations have focused on the small STEM community – an exercise in diminishing returns. In essence, the solution often boils down to finding unicorns – officers that have chartered the unforgiving pathway through the traditional “gates” to general officer while obtaining sufficient STEM proficiency along the way. Fortunately for the Air Force, these officers exist, albeit at a rate below what the evidence would suggest is necessary. However, this approach fundamentally limits the ability to develop a deep pool of officers with the ability to create and integrate technologies and ensures the Dunning-Kruger effect is prevalent. The Dunning-Kruger effect is a cognitive bias where those with limited knowledge in an area lack the expertise necessary to recognize their lack of expertise and consequently are prone to overestimate their knowledge and performance. In short, we need less leaders overestimating their STEM knowledge and more with hard-earned STEM competency required to “walk the walk” to create and integrate technologies for military advantage. This will not be accomplished by restricting the emphasis to the traditional scientists and engineering (S&E) career fields – the pool, only 10% of line officers, and general officer progression is just too small. Fortunately, the recent SECAF’s Management Initiatives and Chief of Staff’s (CSAF) Action Orders, both containing emphasis on organic expertise to “accrue advantage in military-technological competition,” present an opportunity to truly develop a framework for the force of the future.

99 GENERAL AND MISCELLANEOUS↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mojave firmware 1.09 FW valuation- Firmware 1.09 Results

This quick note outlines what we found after our conversion with you and your team. As suggested, we loaded 1547-2003 source requirements document (SRD) and then went back and loaded 1547-2018 SRD. This did result in implementing the new 1547-2018 settings. This short report focuses on the frequency-watt function and shows a couple of screen shots of the parameter settings via the Mojave HMI interface and plots of the results of the inverter with FW function enabled in both default and most aggressive settings response to frequency events. The first screen shot shows the 1547-2018 selected after selecting 1547-2003.

97 MATHEMATICS AND COMPUTING↗

Modular Control Architecture for Scalable, Resilient, and Cybersecure Microgrids Test Results [Mojave firmware 1.09 FW valuation]

This quick note outlines what we found after our conversion with you and your team. As suggested, we loaded 1547-2003 source requirements document (SRD) and then went back and loaded 1547-2018 SRD. This did result in implementing the new 1547-2018 settings. This short report focuses on the frequency-watt function and shows a couple of screen shots of the parameter settings via the Mojave HMI interface and plots of the results of the inverter with FW function enabled in both default and most aggressive settings response to frequency events. The first screen shot shows the 1547-2018 selected after selecting 1547-2003.

42 ENGINEERING↗

Design for Remanufacturing

The objective of this project was to develop relationships between published scholarship, industry experience, and remanufacturing design rules and identify a clear path for integrating remanufacturing design rules into CAD tools and design practices. To accomplish this, remanufacturing knowledge was compiled, and then the relationships between this knowledge and a prioritized set of product design guidelines was developed. Next, a process to create rules out of guidelines was developed by first defining life extension as a primary function, and remanufacturing as effective tasks to control the failure modes that would restrict the product life. The reliability centered maintenance (RCM) process was used to identify proactive tasks and default actions to mitigate the effects of failure modes. These tasks were developed into expert system rules. The impact of design on remanufacturing was then validated through implementing a prioritized set of design rules for a Heavy Duty Off-Road (HDOR) techno-economic case study. Finally, detailed steps on how to define, develop, and integrate these rules into CAD were created.

42 ENGINEERING↗

Optimization of artificial viscosity in production codes based on Gaussian Regression surrogate models

To accurately model flows with shock waves using staggered-grid Lagrangian hydrodynamics, artificial viscosity has to be introduced to convert kinetic energy into internal energy, thereby increasing the entropy across shocks. Determining the appropriate strength of the artificial viscosity is an art and strongly depends on the particular problem and experience of the researcher. The objective of this study is to pose the problem of finding the appropriate strength of artificial viscosity as an optimization problem and solve this problem using machine learning (ML) tools, specifically using surrogate models based on Gaussian Process regression and Bayesian analysis. We describe the optimization method and discuss various practical details of its implementation. The shock-containing problems for which we apply this method all have been implemented in the LANL code FLAG. First, we apply ML to find optimal values to isolated shock problems of different strengths. Second, we apply ML to optimize viscosity for a 1D propagating detonation problem based on Zel’dovich-von Neumann-Doring (ZND) detonation theory using a reactive burn model. We compare results for default (currently used values in FLAG) and optimized values of artificial viscosity for these problems demonstrating the potential for significant improvement in the accuracy of computations.

42 ENGINEERING↗

Fitting $\overline{\nu}$ for minor Pu isotopes

After successful fitting of prompt $\overline{\nu}$ for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we will move on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. To mitigate these challenges— and provide consistency within CGMF—we will take a stepped approach to the optimization. Continuing from the 239 Pu work, we will then fit 241 Pu(n,f) $\overline{\nu}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we can consistently optimize 240 Pu(n,f) $\overline{\nu}$. Following that step, we will move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We will possibly also be able to develop systematics for the CGMF input parameters along the Pu isotopic chain. This work can serve as a guide to broadening the reactions available in CGMF. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will shown in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points.

07 ISOTOPE AND RADIATION SOURCES↗

Changing the Remit to Address on an Ariba Network Invoice [Slides]

The process described in this presentation is optional but will be helpful to suppliers who use multiple remit to addresses in their interactions with LANL. After completing these steps, suppliers will be able to change the remit to address when generating an electronic invoice from the default value assigned by Ariba.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of 3D Simulation Capabilities within xRAGE using a Suite of Test Problems

This presentation describes a 3D verification and validation suite for xRAGE. Three verification test problems for hydrodynamics are presented: the Kidder ball problem, the Verney shell problem, and a 5-material compression problem. There is excellent agreement between 2D and 3D XRAGE simulation results for these problems, and between the xRAGE results and the benchmark solutions. In addition, two 3D ICF test problems are presented, based on an OMEGA direct drive capsule experiment, and on a NIF indirect drive capsule experiment. These two ICF test problems are used to evaluate two hydrodynamic methods within xRAGE. In addition to hydrodynamics the simulations also include three temperature plasma physics, thermal conduction and radiation diffusion. When simulating either capsule in 3D the newer unsplit hydrodynamic method in xRAGE produces more vorticity relative to the older default method. For the indirect drive capsule the 3D simulations are in reasonable agreement with the experimental values of ion temperature and neutron production. Unstable 3D vortex rings are present near the DT ice/carbon interface which enhance the confinement of the DT ice.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-Term Electricity Requirement and Emission Implications for Sustainable Aviation Fuel Production with CO 2 -to-Fuels Technologies

Aviation contributed approximately 10% of the U.S. transportation sector's greenhouse gas (GHG) emissions and about 3% of the nation's total GHG production before the coronavirus disease (COVID-19) pandemic (EPA 2022). Unlike the ground transportation sector, which can be decarbonized by using batteries and hydrogen fuel cell powertrain technologies, the technical and economic challenges of aviation electrification open the opportunity for CO 2 utilization (CO2U) using clean power sources. The U.S. government set a goal to produce 3 billion gallons per year of sustainable aviation fuels (SAF) by 2030 and scale up the production to 35 billion gallons per year by 2050 (Bioenergy Technologies Office 2022). In this report, we examine three potential locations, in California, Iowa, and Louisiana, for SAF production using two production pathways that are expected to be available by 2030. We analyze the electricity cost to satisfy 10% of the SAF production potential for the select locations. Specifically, we consider (1) retail electricity cost from the default local utility in each location; (2) physical power purchase agreement (PPA) for renewable power and battery storage hybrid systems with preset prices; (3) financial PPA from a dedicated renewable plant; and (4) estimated real-time pricing (RTP) from the wholesale power market with utility delivery adders. Retail rates are available for the three potential locations; however, the developer should negotiate with the local utility in Iowa for new tariff riders, because the load of the proposed SAF plant (1.4 GW) is significantly higher than the current industrial tariff structure requirement (200 kW). The developers are not able to claim federal credits (i.e., the Inflation Reduction Act of 2022) when sourcing electricity from local utilities. Developers could consider prioritizing physical and financial PPAs as purchase options. While physical PPAs can be imported out of state, this structure imposes availability issues as developers must locate in the same electricity grid regions. Financial PPAs do not have the same location restrictions and provide the same cost savings as physical PPAs, but financial PPAs impose financial risks in the event of system curtailment and grid interruption. RTPs are available for customers in California with flexible load and hourly load management capability; however, utilities in our studied regions in Louisiana and Iowa only offer time-of-use and curtailment programs to incentivize lower energy usage in peak hours. These utilities do not currently offer RTP programs, and the developer may need to have further negotiations with the local utilities to access RTP programs. The results show that purchased electricity prices may range from 2.6 cents/kWh to 7.1 cents/kWh for the three studied plants.

02 PETROLEUM↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K2O, LaBr3, KBr, Cu, Zr, F, Ga, Ga2O3, NaNO2, Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated assuming 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradioactive chemical

54 ENVIRONMENTAL SCIENCES↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradradioactive chemicals modeled. And finally, the calculations assume all 12 tests will be performed at the same place at both locations, and all 11 radioactive material types will be used for each test. This is conservative because it is anticipated that no more than two material types will be used per test.

99 GENERAL AND MISCELLANEOUS↗

Pavilion 2 Feature Additions [Slides]

Pavilion 2 is a critical component of system testing for LANL HPC systems. Pavilion 2 is system independent, which allows for the creation of a large suite of generalized tests than can be applied to multiple systems. These additions to Pavilion 2 improve our ability to test systems and diagnose issues. With such a large suite, running the proper tests when diagnosing and fixing a system can be difficult, as well as locating old tests for reference. Test configurations may contain several permutations of a test, not all of which may apply to a given system. The ability to run sets of test permutations lets the tester focus on specific parts of the test without having to edit the test configurations or run extraneous tests. The addition of the filter argument improves the ability to find test results based on test attributes, including past tests. Pavilion 2's system independence is largely based on various layers of configuration files. Configuration files for the host, test, and modes exist to allow generalized testing. The operating system configuration layer can provide helpful OS defaults to a test. Survey, a collection and reporting tool, can help us gauge the performance of a system as well as diagnose issues. The addition of a Survey mode in Pavilion 2 makes running tests with Survey very straightforward. The Survey results are combined with Pavilion 2's test results to make it easy to access.

97 MATHEMATICS AND COMPUTING↗

Pavilion 2 Feature Additions [Slides]

Pavilion 2 is a critical component of system testing for LANL HPC systems. Pavilion 2 is system independent, which allows for the creation of a large suite of generalized tests than can be applied to multiple systems. These additions to Pavilion 2 improve our ability to test systems and diagnose issues. With such a large suite, running the proper tests when diagnosing and fixing a system can be difficult, as well as locating old tests for reference. Test configurations may contain several permutations of a test, not all of which may apply to a given system. The ability to run sets of test permutations lets the tester focus on specific parts of the test without having to edit the test configurations or run extraneous tests. The addition of the filter argument improves the ability to find test results based on test attributes, including past tests. Pavilion 2's system independence is largely based on various layers of configuration files. Configuration files for the host, test, and modes exist to allow generalized testing. The operating system configuration layer can provide helpful OS defaults to a test. Survey, a collection and reporting tool, can help us gauge the performance of a system as well as diagnose issues. The addition of a Survey mode in Pavilion 2 makes running tests with Survey very straightforward. The Survey results are combined with Pavilion 2's test results to make it easy to access.

97 MATHEMATICS AND COMPUTING↗