Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Simulations of Sparse Static Detector Networks for City-Scale Radiological/Nuclear Detection

Sparse static detector networks in urban environments can be used in efforts to detect illicit radioactive sources, such as stolen nuclear material or radioactive "dirty bombs." We use detailed simulations to evaluate multiple configurations of detector networks and their ability to detect sources moving through a $6\times 6$ km 2 area of downtown Chicago. A detector network's probability of detecting a source increases with detector density but can also be increased with strategic node placement. Here, we show that the ability to fuse correlated data from a source-carrying vehicle passing by multiple detectors can significantly contribute to the overall detection probability. In this article, we distinguish static sensor deployments operated as networks able to correlate signals between sensors, from deployments operated as arrays where each sensor is operated individually. In particular, we show that additional visual attributes of source-carrying vehicles, such as vehicle color and make, can greatly improve the ability of a detector network to detect illicit sources.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Use of carbonyldiimidazole as a derivatization agent for the detection of pinacolyl alcohol, a forensic marker for Soman, by EI-GC–MS and LC-HRMS in official OPCW proficiency test matrices

Pinacolyl alcohol (PA), a key forensic marker for the nerve agent Soman (GD), is a particularly difficult analyte to detect by various analytical methods. In this work, we have explored the reaction between PA and 1,1'-carbonyldiimidazole (CDI) to yield pinacolyl 1H-imidazole-1-carboxylate (PIC), a product that can be conveniently detected by gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Regarding its GC–MS profile, this new carbamate derivative of PA possesses favorable chromatographic features such as a sharp peak and a longer retention time (RT = 16.62 min) relative to PA (broad peak and short retention time, RT = 4.1 min). Additionally, the derivative can also be detected by LC-HRMS, providing an avenue for the analysis of this chemical using this technique where PA is virtually undetectable unless present in large concentrations. From a forensic science standpoint, detection of this low molecular weight alcohol signals the past or latent presence of the nerve agent Soman (GD) in a given matrix (i.e., environmental or biological). The efficiency of the protocol was tested separately in the analysis and detection of PA by EI-GC–MS and LC-HRMS when present at a 10 μg/mL in a soil matrix featured in the 44th PT and in a glycerol-rich liquid matrix featured in the 48th Official Organization for the Prohibition of Chemical Weapons (OPCW) Proficiency Test when present at a 5 μg/mL concentration. In both scenarios, PA was successfully transformed into PIC, establishing the protocol as an additional tool for the analysis of this unnatural and unique nerve agent marker by GC–MS and LC-HRMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

pyFLANK, a graph neural network based null distribution inference model for F ST outlier detection

Detecting genomic regions under selection is essential for understanding how populations adapt to different environments, yet it remains challenging due to the confounding effects of demographic history and linkage disequilibrium (LD). Fixation index (F ST ) is a widely used statistic to identify genomic regions under adaptation. However, identifying genes under selection by defining F ST outliers often remains challenging, owing to confounding effects of underlying demographic history. Traditional methods assume independence among loci and rely on simple demographic models, while newer models perform much better but are computationally expensive and not easily scalable. Here, we present pyFLANK, an open-source and automated Python implementation which detects F ST outliers using a null distribution inferred from quasi-independent loci. Our tool integrates three approaches to identify loci obeying a null distribution: graph neural network (GNN) inference, linkage disequilibrium (LD)-based inference, and user-defined input. Because pyFLANK uses GNN-based inference of quasi-independent loci, it yields a more accurate null model with less need for user parameter input. In simulation experiments, pyFLANK achieved lower false positive rates than current methods while maintaining comparable detection power, indicating that its refined null model better distinguishes true adaptive loci from background variation. The GNN-based model, in particular, detected additional loci associated with phenotypic variance that were not identified by existing methods. Assessments of simulation and real data from different species demonstrate that pyFLANK achieves lower false positive rates compared with other commonly used F ST outlier detectors, while maintaining comparable detection power and excellent computational performance, providing a robust and user-friendly tool for identifying loci under divergent selection. It extends existing F ST outlier frameworks by incorporating explicit LD-aware strategies for null model calibration. The method is intended as a practical and scalable complement to existing genome scan approaches.

FST↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

Detection of trace contaminants released from rapidly heated pulsed power electrodes by laser diagnostics

Development of a capability to measure trace gas contaminants released from pulsed power electrodes would immediately impact Sandia pulsed power research. These releases occur during ultra-fast heating of metal electrodes during pulsed power discharges and can lead to substantial power losses through plasma formation. Detection of contaminants is a formidable challenge due to the need for in-situ spatially and temporally resolved measurements of trace gases in the extreme environment of ultra-fast heated metal surfaces. We investigate the feasibility of laser diagnostics for detecting contaminants, including H-atom, OH, and H 2 O. Laser-induced fluorescence and photofragmentation fluorescence showed significant plasma emission interferences and did not yield any detectable H-atom, OH, or H 2 O. Our newly developed H-atom detection using femtosecond degenerate four-wave mixing suppressed interferences and enabled detection of H-atoms. A few shots showed large signals in the near-surface region of metal foils, suggesting the formation of a wave of H-atoms from the metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Warped April Tag Impacts on Detection and Pose Estimation

This report evaluates the impact of geometric deformation on an April Tag, particularly when warped due to attachment on a curved surface, on its detectability and pose estimation performance. A comparative analysis was conducted using a flat April Tag as a control under identical experimental conditions, which involved recording video sequences with varying viewing angles. For detectability, the warped tag exhibited consistent detection failures at viewing angles beyond 40° and complete failures beyond 60°, whereas the flat tag maintained reliable detection across all angles. For pose estimation, measured by pose jitter (variation in rotation and translation), differences between the warped and flat tags were minimal and statistically insignificant, indicating robust performance even for the deformed tag. These findings suggest that while geometric warping reduces an April Tag’s detectability, its pose estimation accuracy remains relatively unaffected under the tested conditions.

42 ENGINEERING↗

Nucleic Acid-Based Detection Protease Activity

Proteases include clinically relevant markers for clotting disorders, certain cancers as well as toxins. Assays for protease activity often use designed peptides mimicking natural substrates and detection with colorometric and fluorescence-based detection that is difficult to multiplex without expensive and resource demanding instruments. This work demonstrates detection of proteolytic activity using PCR and sequencing-readable reporter molecules. The assay development focused on binding the constructed peptide-oligonucleotide chimera to immobilized streptavidin. Thrombin, an essential component of the clotting cascade, was used as a model system for testing peptide substrate recognition and release of a designed oligonucleotide for detection. Detection of protease activity was demonstrated in a concentration-dependent manner using MALDI-MS, RT-PCR and DNA sequencing.

Wunschel, David S [Pacific Northwest National Labo↗

AEPF: Attention-Enabled Point Fusion for 3D Object Detection

Current state-of-the-art (SOTA) LiDAR-only detectors perform well for 3D object detection tasks, but point cloud data are typically sparse and lacks semantic information. Detailed semantic information obtained from camera images can be added with existing LiDAR-based detectors to create a robust 3D detection pipeline. With two different data types, a major challenge in developing multi-modal sensor fusion networks is to achieve effective data fusion while managing computational resources. With separate 2D and 3D feature extraction backbones, feature fusion can become more challenging as these modes generate different gradients, leading to gradient conflicts and suboptimal convergence during network optimization. To this end, we propose a 3D object detection method, Attention-Enabled Point Fusion (AEPF). AEPF uses images and voxelized point cloud data as inputs and estimates the 3D bounding boxes of object locations as outputs. An attention mechanism is introduced to an existing feature fusion strategy to improve 3D detection accuracy and two variants are proposed. These two variants, AEPF-Small and AEPF-Large, address different needs. AEPF-Small, with a lightweight attention module and fewer parameters, offers fast inference. AEPF-Large, with a more complex attention module and increased parameters, provides higher accuracy than baseline models. Experimental results on the KITTI validation set show that AEPF-Small maintains SOTA 3D detection accuracy while inferencing at higher speeds. AEPF-Large achieves mean average precision scores of 91.13, 79.06, and 76.15 for the car class’s easy, medium, and hard targets, respectively, in the KITTI validation set. Results from ablation experiments are also presented to support the choice of model architecture.

Chemistry↗

A Systematic Search for MeV–GeV Pulsar Wind Nebulae without Gamma-Ray Detected Pulsars

An increasing number of pulsar wind nebulae (PWNe) are being identified in the TeV band by ground-based Imaging Air Cherenkov Telescopes such that they constitute the dominant source class of Galactic TeV emitters. However, MeV–GeV PWN counterparts are still largely lacking. To date, only a dozen PWNe are identified by the Fermi–Large Area Telescope (LAT) in the MeV–GeV band. Most PWNe are located along the Galactic plane embedded within the prominent, diffuse Galactic γ-ray emission, which makes these sources difficult to disentangle from the bright diffuse background. We present a systematic search for γ-ray counterparts to known PWNe in the 300 MeV–2 TeV energy band using the Fermi–LAT. We target the locations of previously identified PWNe that lack detected Fermi–LAT pulsars to minimize associated pulsar contamination. The sample includes six previously identified Fermi PWNe and eight Fermi–LAT sources associated with PWNe. We report the analysis of 58 regions of interest and classify Fermi–LAT detected sources as either a likely PWN or a candidate PWN counterpart based on their morphological and spectral characteristics across the broadband spectrum. There are nine unidentified Fermi–LAT sources that we consider as likely PWN counterparts, which, if confirmed to be PWNe, would greatly increase the PWN population detected by the Fermi–LAT from 12 to 21. The remaining Fermi–LAT detected sources are considered weaker PWN candidates. A second approach in the systematic search for γ-ray emitting PWNe will involve studying the off-pulse phases of Fermi–LAT detected pulsars for the presence of an obscured PWN and will be reported in a subsequent paper.

Acharyya, A. [Univ. of Southern Denmark, Odense (D↗

Remote-sensing detectability of airborne Arctic dust

Remote-sensing (RS)-based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on questionable claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness temperature differences at 11 and 12 µm (BTD 11–12 ), has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD 11–12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One much more likely contributor would be water clouds in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD 11–12 values would, however, only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced ice-nucleating particle (INP) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can readily be detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate-sensitive region.

54 ENVIRONMENTAL SCIENCES↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Optical Production and Detection of Ultrasonic Waves in Metals for Nondestructive Testing

Ultrasonic waves were produced by striking the surface of a metal with the focused one-joule pulse of a Q-switched ruby laser. Rayleigh (surface) waves and longitudinal waves were detected with conventional transducers. Optical methods of detection were tested and developed. Rayleigh waves were produced with an oscillator and transducer. They were optically detected on curved polished surfaces, and on unpolished surfaces. The technique uses a knife edge to detect small angle changes of the surface as the wave pulse passes the illuminated spot. Optical flaw detection using pulse echo and attenuation is demonstrated.

Morrison, R. A.↗

Single photon detection and timing - Experiments and techniques.

Single photon detection and timing means essentially the detection and timing of a single photoelectron released by light from a photosensitive surface of a photomultiplier, channel multiplier, avalanche multiplier photodiode, or other photodevice. Necessary photodevice gain and detection circuits, mechanisms and statistics of photodevice gain, photodevice and background noise and their reduction, and practical photodevice techniques and photon detection performance tests are discussed. Fast timing with single photons, and single photon detection with moderate timing requirements are considered.

Poultney, S. K.↗

Threshold detection in an on-off binary communications channel with atmospheric scintillation

The optimum detection threshold in an on-off binary optical communications system operating in the presence of atmospheric turbulence was investigated assuming a poisson detection process and log normal scintillation. The dependence of the probability of bit error on log amplitude variance and received signal strength was analyzed and semi-emperical relationships to predict the optimum detection threshold derived. On the basis of this analysis a piecewise linear model for an adaptive threshold detection system is presented. Bit error probabilities for non-optimum threshold detection system were also investigated.

Webb, W. E.↗

A noise study of the A-6 airplane and techniques for reducing its aural detection distance

A study was undertaken to determine the noise reduction potential of the A-6 airplane in order to reduce its aural detection distance. Static and flyby noise measurements were taken to document the basic airplane signature. The low-frequency noise which is generally most critical for aural detection was found to be broad-band in nature from this airplane, and its source is the turbojet engine exhaust. High-frequency compressor noise, which is characteristic of turbojet powerplants, and which is prominent at close range for this airplane, has no measurable effect on aural detection distance. The use of fluted-engine exhaust nozzles to change the far-field noise spectra is suggested as a possible means for reducing the aural detection distances. Detection distances associated with eight-lobe and four-lobe nozzles are estimated for a 1,000-foot altitude and grassy terrain to decrease from 4 miles to about 3 miles, and from 3 miles to about 2 miles for a 300-foot altitude and grassy terrain.

Hilton, D. A.↗

Threshold detection in an on-off binary communications channel with atmospheric scintillation

The optimum detection threshold in an on-off binary optical communications system operating in the presence of atmospheric turbulence was investigated assuming a poisson detection process and log normal scintillation. The dependence of the probability of bit error on log amplitude variance and received signal strength was analyzed and semi-empirical relationships to predict the optimum detection threshold derived. On the basis of this analysis a piecewise linear model for an adaptive threshold detection system is presented. The bit error probabilities for nonoptimum threshold detection systems were also investigated.

Webb, W. E.↗

Threshold detection in an on-off binary communications channel with atmospheric scintillation

The optimum detection threshold in an on-off binary optical communications system operating in the presence of atmospheric turbulence has been investigated assuming a Poisson detection process and log normal scintillation. The dependence of the probability of bit error on log amplitude variance and received signal strength has been analyzed, and semi-empirical relationships to predict the optimum detection threshold have been derived. On the basis of this analysis, a piecewise-linear model for an adaptive threshold detection system is presented. The bit-error probabilities for nonoptimum threshold detection systems have also been investigated.

Webb, W. E.↗