At least 361 records · Page 20

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal Conditioning for Satellite Borne Energetic-Charged-Particle Experiments

Many of the spacecraft launched thus far have carried detectors for investigating cosmic rays, solar protons, solar plasmas, and the geomagnetically trapped radiation. These detectors, which will find continued application in the future, include ion chambers; proportional, Geiger-Muller, scintillation, Cerenkov, and solid state detectors; ion collectors; and nuclear emulsions. The instrumentation required to condition the signals from these detectors prior to telemetering is steadily growing more complex in order to permit more meaningful measurements. This report describes a number of instrumentation elements typical of the present state of the art, and a present-generation three-detector system which illustrates the integration of such basic elements into a complex system.

Ludwig, George H.↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Development of a Sodium LIDAR for Spaceborne Missions

We are currently developing laser and electro-optic technologies to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of a Heliophysics mission targeted to study the composition and dynamics of Earths mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. There is a pressing need in the Ionosphere Thermosphere - Mesosphere (ITM) community for high-resolution measurements that can characterize small-scale dynamics (i.e. Gravity Waves with wavelengths smaller than a few hundred km) and their effects in the Mesosphere-Lower-Termosphere (MLT) on a global basis. This is compelling because they are believed to be the dominant contributors to momentum transport and deposition in the MLT, which largely drive the global circulation and thermal structure and interactions with the tides and planetary waves in this region. We are developing a spaceborne remote sensing technique that will enable acquisition of global Na density, temperature and wind measurements in the MLT with the spatial and temporal resolution required to resolve issues associated with the structure, chemistry, dynamics, and energetics of this regionA nadir-pointing spaceborne Na Doppler resonance fluorescence LIDAR on board of the ISS will essentially make high-resolution, in time and space, Na density, temperature and vertical wind measurements, from 75-115 km (MLT region). Our instrument concept consisted of a high-energy laser transmitter at 589 nm and highly sensitive photon counting detector that allows for range-resolved atmospheric-sodium-temperature profiles. The atmospheric temperature is deduced from the linewidth of the resonant fluorescence from the atomic sodium vapor D2 line as measured by our tunable laser. We are currently developing a high power energy laser that allows for some day time sodium lidar observations with the help of a narrow bandpass filter based on etalon or atomic sodium Faraday filter with 5 to 10 pm optical bandwidth. The current baseline detector for the lidar instrument is a 16-channel Photomultiplier Tube with receiver electronics that has been space-qualified for the ICESat-2ATLAS mission. Our technique uses the 16-channels as a photon-number-resolving single detector to provide the required full-spectroscopic sodium lineshape waveform for recovering Mesospheric temperature profiles. In this paper, we will describe our instrument concept for a future Heliophysics space mission based on board of the International Space Station (ISS).

lidar↗

Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

Dark matter lighter than 10 GeV / c 2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10 MeV / c 2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications

Two optically clear, bright, scintillating ZnS materials have been identified that, like previous opaque ZnS scintillators, are excellent charged particle detectors. We show that ZnS is a good fast-neutron-to charged-particle converter making optically clear ZnS an intrinsic fast-neutron detector that does not require layering or mixing of converter materials and scintillator materials, and removes the limitations imposed by opaque ZnS scintillator materials used for more than a century. Thermal neutron detection using optically clear 6 LiF or 10 BN and clear ZnS may benefit from improved spatial resolution and light transmission. Properties and tests of clear scintillating ZnS are described. Fast-neutron imaging applications benefit from increased efficiency of these scintillators, minimal scattering in the scintillator, and increased useful detector volume. Charged particle and fast-neutron detectors have numerous applications in nuclear non-proliferation and security, nuclear and particle physics, and non-destructive testing and environmental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent developments on a 128 x 128 indium antimonide/FET switch hybrid imager for low-background applications

By combining high-quality mesa photovoltaic indium antimonide detector material with a silicon x-y FET switch multiplexer, a useful infrared area detector has been developed. This device is intended for low-background applications, where high sensitivity is required. Initial characterization of the detector at 80 K showed a KTC limited read noise of less than 1000 electrons, good dark current, responsivity uniformity, and a maximum readout rate of 10 MHz. The hybrid mating technology has sufficient precision to allow expansion to a 256 x 256 format. The dark current in the detector material is sufficiently low to allow full-frame integration, even with arrays as large as 256 x 256 elements.

Bailey, Gary C.↗

Development of High Resolution Mirrors and Cd-Zn-Te Detectors for Hard X-ray Astronomy

We describe the fabrication and implementation of a high-resolution conical, grazing- incidence, hard X-ray (20-70 keV) telescope. When flown aboard stratospheric balloons, these mirrors are used to image cosmic sources such as supernovae, neutron stars, and quasars. The fabrication process involves generating super-polished mandrels, mirror shell electroforming, and mirror testing. The cylindrical mandrels consist of two conical segments; each segment is approximately 305 mm long. These mandrels are first, precision ground to within approx. 1.0 micron straightness along each conical segment and then lapped and polished to less than 0.5 micron straightness. Each mandrel segment is the super-polished to an average surface roughness of approx. 3.25 angstrom rms. By mirror shell replication, this combination of good figure and low surface roughness has enabled us to achieve 15 arcsec, confirmed by X-ray measurements in the Marshall Space Flight Center 102 meter test facility. To image the focused X-rays requires a focal plane detector with appropriate spatial resolution. For 15 arcsec optics of 6 meter focal length, this resolution must be around 200 microns. In addition, the detector must have a high efficiency, relatively high energy resolution, and low background. We are currently developing Cadmium-Zinc-Telluride fine-pixel detectors for this purpose. The detectors under study consist of a 16x16 pixel array with a pixel pitch of 300 microns and are 1 mm and 2 mm thick. At 60 keV, the measured energy resolution is around 2%.

Ramsey, Brian D.↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Measurement of inclusive and differential cross sections for single top quark production in association with a W boson in proton-proton collisions at $\sqrt{s}$ = 13 TeV

Measurements of the inclusive and normalised differential cross sections are presented for the production of single top quarks in association with a W boson in proton-proton collisions at a centre-of-mass energy of 13 TeV. The data used were recorded with the CMS detector at the LHC during 2016–2018, and correspond to an integrated luminosity of 138 fb -1 . Events containing one electron and one muon in the final state are analysed. For the inclusive measurement, a multivariate discriminant, exploiting the kinematic properties of the events is used to separate the signal from the dominant t$\overline{t}$ background. A cross section of 79.2 ± 0.9(stat)$^{+7.7}_{-8.0}$ (syst) ± 1.2 (lumi) pb is obtained, consistent with the predictions of the standard model. For the differential measurements, a fiducial region is defined according to the detector acceptance, and the requirement of exactly one jet coming from the fragmentation of a bottom quark. The resulting distributions are unfolded to particle level and agree with the predictions at next-to-leading order in perturbative quantum chromodynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Free-moving Quantitative Gamma-ray Imaging

The ability to map and estimate the activity of radiological source distributions in unknown three-dimensional environments has applications in the prevention and response to radiological accidents or threats as well as the enforcement and verification of international nuclear non-proliferation agreements. Such a capability requires well-characterized detector response functions, accurate time-dependent detector position and orientation data, a digitized representation of the surrounding 3D environment, and appropriate image reconstruction and uncertainty quantification methods. We have previously demonstrated 3D mapping of gamma-ray emitters with free-moving detector systems on a relative intensity scale using a technique called Scene Data Fusion (SDF). Here we characterize the detector response of a multi-element gamma-ray imaging system using experimentally benchmarked Monte Carlo simulations and perform 3D mapping on an absolute intensity scale. We present experimental reconstruction results from hand-carried and airborne measurements with point-like and distributed sources in known configurations, demonstrating quantitative SDF in complex 3D environments.

47 OTHER INSTRUMENTATION↗

The contribution of Compton ionization to ultrafast x-ray scattering

We investigate the role of Compton ionization in ultrafast non-resonant x-ray scattering using a molecular model system, which includes the ionization continuum via an orthonormalized plane wave ansatz. Elastic and inelastic components of the scattering signal, as well as coherent-mixed scattering that arises from electron dynamics, are calculated. By virtue of a near-quantitative distinction between scattering related to electronic transitions into bound and continuum states, we demonstrate how Compton ionization contributes to the coherent-mixed component. Analogous to inelastic scattering, the contribution to the coherent-mixed signal is significant and particularly manifests at intermediate and high-momentum transfers. Strikingly, for molecules with inversion symmetry, the exclusion of bound or continuum transitions may lead to the prediction of spurious coherent-mixed signals. We conclude that qualitative and quantitative accuracies of predicted scattering signals on detectors without energy resolution require that elements of the two-electron density operator are used. This approach inherently accounts for all accessible electronic transitions, including ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Strain Sensing for Particle Detection

Optomechanical strain sensing provides attractive opportunities for novel particle detection schemes, as well as studying stress-induced (i.e. non-radiogenic) phonon bursts, which have been demonstrated to limit the coherence times of superconducting qubits and are a suspected culprit in the low energy excesses observed by many dark matter direct detection experiments. We are investigating SiN microring optical resonator strain sensors, developed at Purdue University, for applications in fundamental particle sensing and QIS. These sensors can be embedded in the substrate upon which superconducting qubits are patterned, providing a handle to distinguish decoherence events of radiogenic origin from those due to crystal stress. In a similar way, these sensors can be operated in conjunction with superconducting detectors (e.g., MKIDs, TES) to enable multi-channel readout of particle interactions in the device substrate or serve as anticoincidence detectors, which may be required to ident ify low-energy interactions from dark matter particles down to the fermionic thermal relic mass limit of a few keV. Such sensors can potentially be used to directly observe resonant scattering processes of gamma rays (and perhaps neutrinos) where no detectable quanta are produced in the target, via the microscopic stress induced by the momentum transfer to the (fixed-in-place) crystal lattice as a whole. These strain sensors have so far found application in photonics and communications, but have yet to be adopted for HEP uses, where they can provide unique capabilities in the search for dark matter as well as understanding and improving the coherence times of superconducting qubits.

43 PARTICLE ACCELERATORS↗

A portable self-contained gas chromatograph.

The design and fabrication of a completely portable, self-contained gas chromatograph is described. This instrument utilizes a closed-loop hydrogen carrier gas flow as maintained by a hydrogen generator-separator. It employs an auxiliary hydrogen generator to keep a positive flow of hydrogen through the detector. The detector is an ionization cross section detector. The only maintenance required is the addition of water (5-15 cc/day) to the auxiliary hydrogen generator. Lower limit of detection for the present system is of the order of 1-10 ppm ethane.

Stevens, M. R.↗

Very high resolution radiometer /VHRR/

Discussion of the design and performance of the very high resolution radiometer (VHRR) representing the first of a second-generation of infrared scanning radiometers of high performance. Following a description of the optical, signal-electronics, sync-generator, scan-drive, cooler, and contamination-protection design, it is pointed out that the two VHRRs presently operating have logged a total of 15,500 hrs of continuous successful operation since launch. The cooler operation has been particularly noteworthy. The cold plate heater power, required to maintain the detectors at 105 K, has undergone in almost a year's operation so small a degradation as to indicate a VHRR cooler lifetime exceeding the instrument design lifetime of one year by a large margin. High resolution, low noise, and jitter-free pictures are shown to have been derived from these instruments.

Aronson, A. I.↗