Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct energy conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Integrated Models for Electrical Distribution Network Planning and District-Scale Building Energy Use

The increase of greenhouse emissions caused by a rise in global energy consumption is pushing the scientific community to develop tools that address key environmental, techno-economic and social issues. One specific area of focus is to create tools that enable the design of high-performance energy districts, including grid-interactive efficient buildings and electrical distribution infrastructure. This paper outlines the approach of integrating a synthetic distribution network tool (RNM-US) with URBANopt™, a modular and customizable software development kit for thermal and electrical modelling of buildings and energy systems at a district scale. First, we describe the algorithms implemented to integrate RNM-US with URBANopt to automatically generate the distribution network for the district considered. Following, we present a case study for the potential uses of the RNM-US integrations with URBANopt, highlighting the capabilities for economic and technical analysis of the distribution network built in relation to the electricity needs of the modelled buildings.

30 DIRECT ENERGY CONVERSION↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

A Bulk-Capacitance Reduction Method Using Self-Driven Thyristor for AC-DC Converters

Universal serial bus power delivery (USB-PD) fast chargers equipped with wide-bandgap devices are driven to higher power density and efficiency. Furthermore, the indispensable high-voltage bulk capacitors used to smooth the rectifier output could take 40% of the total system volume due to the large capacitance value required. This paper discussed a capacitor reduction method using a self-driven thyristor scheme comprised of only three components in total. No extra control circuit is needed. Circuit analysis and design equations are presented, and the design results are implemented in a 60-W GaN-based active-clamp flyback converter. The measurement results on the prototype show a 36.4% reduction of the bulk-capacitor size with similar efficiency compared to the conventional solution.

30 DIRECT ENERGY CONVERSION↗

Single-Phase Dielectric Fluid Thermal Management for Power-Dense Automotive Power Electronics

This paper describes the design and performance of a dielectric fluid cooling concept for automotive power electronics. The concept combines a low-thermal-resistance package (which eliminates metalized ceramic substrates) with a high-performance convective cooling strategy (slot jets impinging on finned surfaces). Modeling was first used to design the cooling system to maximize thermal performance and minimize pumping power. Additionally, a prototype was then fabricated, and experiments were conducted to validate the model predictions using three fluids at various fluid flow rates (16.7 cm 3 /s [1 L/min] to 68.3 cm 3 /s [4.1 L/min]) and inlet temperatures (30C and 70C). The final design was compact (120-cm 3 total volume, including heat exchanger and conceptual power modules) and cooled 12 devices (e.g., silicon carbide). The validated model was then used to predict the junction-to-fluid thermal resistance and pumping power for various conditions, including 40C fluid temperature. The results predict thermal resistance values as low as 19 mm 2 K/W are possible using the dielectric fluid cooling approach. The dielectric fluid cooling system is predicted to provide thermal resistance and pumping power values that are approximately 56% and 90% lower, respectively, compared to an automotive power electronics cooling system.

30 DIRECT ENERGY CONVERSION↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current-Source Converters

Magnetic components have become one of the primary barriers to high power density converters, especially to current-source converters (CSCs). In CSCs, the inductors/transformers have a predominantly dc flux to store energy, which can be offset by standard permanent magnets (PMs). However, eddy currents in standard PMs induce significant losses and thermal stress for medium-frequency applications. This article proposes using laminated PMs to offset the dc flux while reducing eddy currents, leading to significant reductions in the size, cost, and losses of inductors/transformers. Furthermore, the laminated PMs’ optimal location, orientation, and distribution are investigated to generalize this approach for maximum benefits. Here, three-dimensional finite-element analysis simulation and hardware experiments are presented to validate the effectiveness of the proposed approach in a medium-frequency transformer (MFT) for CSCs. Compared with standard PMs, the proposed use of laminated PMs reduces aggregate core-plus-PM losses by 85% in experiments, and thus, relaxes the MFT thermal design. Finally, the proposed approach is experimentally validated in a 40 kVA flyback-type MFT for a soft-switching solid-state transformer. Compared to the traditional design without any PMs, the proposed design increases the saturation current by 46% while inducing only 5% more losses, leading to significant savings in magnetics cost and size.

30 DIRECT ENERGY CONVERSION↗

Microgrid Service Restoration Incorporating Unmonitored Automatic Voltage Controllers and Net Metered Loads

Islanded microgrids may experience voltage and frequency instability due to uncontrolled state changes of voltage regulation devices and inaccurate demand forecasts. Uncontrolled state changes can occur if optimal microgrid restoration and dispatch algorithms, used for generating control commands for distributed energy resources, do not incorporate the behavior of automatic controllers of voltage regulation devices. Inaccurate demand forecasts may be encountered since post-outage demand of behind-the-meter net metered (NM) loads can vary significantly from their historical NM profiles. Here, this paper proposes an optimization formulation which allows optimal control of voltage regulators and capacitor banks without remote control and communication capabilities. A generalized demand model for NM loads is proposed which incorporates the cold load pickup phenomenon and their time varying post-outage demand in accordance with the IEEE 1547 standard. The time dependent optimal control formulation and the NM demand model are integrated in a sequential microgrid restoration algorithm by linearization of the involved logic propositions. A detailed case study on the unbalanced IEEE 123-node test system in OpenDSS validates the effectiveness of the proposed approach.

30 DIRECT ENERGY CONVERSION↗

Impacts to FeRAM design arising from interfacial dielectric layers and wake up modulation in ferroelectric hafnium zirconium oxide

As ferroelectric hafnium zirconium oxide (HZO) becomes more widely utilized in ferroelectric microelectronics, integration impacts of intentional and non-intentional dielectric interfaces and their effects upon the ferroelectric film wake up and circuit parameters become important to understand. In this work, the effect of the addition of a linear dielectric aluminum oxide, Al 2 O 3 , below a ferroelectric Hf 0.58 Zr 0.42 O 2 film in a capacitor structure for FeRAM applications with NbN electrodes was measured. Depolarization fields resulting from the linear dielectric is observed to induce a reduction of the remanent polarization of the ferroelectric. Addition of the aluminum oxide also impacts the wake up of the HZO with respect to the cycling voltage applied. Intricately linked to the design of a FeRAM 1C/1T cell, the metal-ferroelectric-insulator-metal (MFIM) devices are observed to significantly shift charge related to the read states based on aluminum oxide thickness and wake up cycling voltage. As a result, a 33% reduction in the separation of read states is measured, which complicates how a memory cell is designed and illustrates the importance of clean interfaces in devices.

30 DIRECT ENERGY CONVERSION↗

Process Failure Detection via Recurrence Quantification Analysis in a Slot-Rectangular Spouted Bed

A study was conducted to explore the applicability of recurrence and recurrence quantification analysis (RQA) to the detection of process failures in spouted bed reactor systems. Here, three different potential failure modes were examined in a transparent, cold flow slot-rectangular spouted bed. These being, a simulated air leak from a side wall of the reactor, a simulated gas leak from the top wall of the reactor, and simulated agglomeration of solids via introduction of larger “klinker” particles. Bed pressure drop time history data were collected and analyzed via generation of recurrence plots (RPs) and RQA parameters. In general, the simulated agglomeration case was quite easily detected via ever RQA Parameter examined, whereas the simulated air leaks were detected by only a single RQA parameter.

30 DIRECT ENERGY CONVERSION↗

Film Cooling Performance Prediction for Air and Supercritical CO 2

The current study explores the possibility of cooling the vanes and blades of a direct-fired sCO 2 turbine using film cooling. The operating conditions of a direct-fired sCO 2 cycle and thermophysical properties of the fluid at those conditions can alter the flow field characteristics of the coolant jet and its mixing with the mainstream. Very little information is present in the literature regarding the performance of film cooling geometries employing supercritical CO 2 . The objective of this study is to estimate the resulting film cooling effectiveness while also capturing the effects of the crossflow-to-mainstream velocity ratio on the coolant jet. Herein, a computational fluid dynamic model is used to study the coolant jet exiting a cylindrical hole located on a flat plate, with the coolant fed by an internal channel. Steady-state Reynolds-averaged Navier–Stokes equations were solved along with the (shear-stress transport) SST k–ω model to provide the turbulence closure. The operating conditions for the direct-fired sCO 2 turbine are obtained using an in-house Cooled Turbine Model. Numerical predictions revealed that the crossflow effects and jet lift-off were more pronounced in the case of sCO 2 when compared to air. Spatial distribution of flow field and cooling effectiveness are presented at different operating conditions.

30 DIRECT ENERGY CONVERSION↗

Physics-Informed Deep Learning-Based Proof-of-Concept Study of a Novel Elastohydrodynamic Seal for Supercritical CO 2 Turbomachinery

Supercritical carbon dioxide (sCO 2 ) power cycles show promising potential of higher plant efficiencies and power densities for a wide range of power generation applications such as fossil fuel power plants, nuclear power production, solar power, and geothermal power generation. sCO 2 leakage through the turbomachinery has been one of the main concerns in such applications. To offer a potential solution, we propose an elastohydrodynamic (EHD) seal that can work at elevated pressures and temperatures with low leakage and minimal wear. The EHD seal has a very simple, sleeve-like structure, wrapping on the rotor with minimal initial clearance at micron levels. Here, in this work, a proof-of-concept study for the proposed EHD seal was presented by using the simplified Reynolds equation and Lame’s formula for the fluid flow in the clearance and for seal deformation, respectively. The set of nonlinear equations was solved by using both the conventional Prediction–Correction (PC) method and modern Physics-Informed Neural Network (PINN). It was shown that the physics-informed deep learning method provided good computational efficiency in resolving the steep pressure gradient in the clearance with good accuracy. The results showed that the leakage rates increased quadratically with working pressures and reached a steady-state at high-pressure values of 15~20 MPa, where Q = 300 g/s at 20 MPa for an initial seal clearance of 255 μm. This indicates that the EHD seal could be tailored to become a potential solution to minimize the sCO 2 discharge in power plants.

30 DIRECT ENERGY CONVERSION↗

Effect of Substrate Temperature on the Electrochemical and Supercapacitance Properties of Pulsed Laser-Deposited Titanium Oxynitride Thin Films

Electrocatalytically active titanium oxynitride (TiNO) thin films were fabricated on commercially available titanium metal plates using a pulsed laser deposition method for energy storage applications. The elemental composition and nature of bonding were analyzed using X-ray photoelectron spectroscopy (XPS) to reveal the reacting species and active sites responsible for the enhanced electrochemical performance of the TiNO electrodes. Symmetric supercapacitor devices were fabricated using two TiNO working electrodes separated by an ion-transporting layer to analyze their real-time performance. The galvanostatic charge–discharge studies on the symmetric cell have indicated that TiNO films deposited on the polycrystalline titanium plates at lower temperatures are superior to TiNO films deposited at higher temperatures in terms of storage characteristics. For example, TiNO films deposited at 300 °C exhibited the highest specific capacity of 69 mF/cm 2 at 0.125 mA/cm 2 with an energy density of 7.5 Wh/cm 2 . The performance of this supercapacitor (300 °C TiNO) device is also found to be ~22% better compared to that of a 500 °C TiNO supercapacitor with a capacitance retention ability of 90% after 1000 cycles. Furthermore, the difference in the electrochemical storage and capacitance properties is attributed to the reduced leaching away of oxygen from the TiNO films by the Ti plate at lower deposition temperatures, leading to higher oxygen content in the TiNO films and, consequently, a high redox activity at the electrode/electrolyte interface.

30 DIRECT ENERGY CONVERSION↗

Characterization of Properties of Laser Powder Bed Fusion 3D-Printed Inconel 718 for Centrifugal Turbomachinery Applications

Here, this paper presents the results of a comprehensive effort to characterize the properties of Inconel 718 produced by a form of laser powder bed fusion (LPBF) additive manufacturing (AM) or 3D-printing, subsequently subjected to hot isostatic pressing (HIP) and heat treatment according to standards F3055-14a and AMS 5663, respectively. Material property data, while broadly available for traditional Inconel 718 presentations (e.g. forgings or castings), is currently lacking for the 3D-printed material. It is expected that while limited in size, the experimental data sets presented provide sufficient information to glean the capability of LPBF Inconel 718. These include: 1) Chemical composition, electron backscatter diffraction (EBSD), and x-ray energy dispersive spectroscopy (XEDS) characterization of 3D-printed material structure; 2) Tensile properties — 0.2% yield stress, ultimate stress, modulus of elasticity, and elongation to failure — based on 108 samples, as functions of temperature and sample print orientation; 3) Creep rupture data including the Larson-Miller parameter, based on 21 samples; and 4) High cycle fatigue data based on 21 samples as a function of temperature. Results are compared to available standards and/or data for forged, cast, and other AM Inconel 718. A key observation of this study, based on the EBSD results, is that while the material appears to approach full recrystallization following heat treatment, there is a detectable fraction of the material that does not fully recrystallize, resulting in a material with mechanical properties (e.g. yield stress, creep rupture) measurably lower than those of forgings, but higher than those of castings.

30 DIRECT ENERGY CONVERSION↗

Development of Modified Perturbation Solutions to the One-Phase Stefan Problems With a Convective Boundary

The classical Stefan problem is used to track the moving solid-liquid interface during the freezing process. Perturbation theory has often been applied to find an approximate analytical solution due to the nonlinearity of the moving interface. However, the Stefan number (i.e., the sensible over latent heat) must be small and usually less than 0.01 to assume the perturbation expansion, which in turn limits the thermal engineering applications. In this study, a modified perturbation solution is developed by adding a correction term after the leading-order solution to be valid for a much wider range of Stefan numbers (i.e., 0.01 less than or equal to Ste less than or equal to 1). Specifically, a one-phase Stefan problem is first formulated subjected to a convective boundary in the Cartesian, cylindrical, and spherical coordinate systems for inward solidification. The leading-order solution is calculated based on the regular perturbation theory, while the correction term is obtained using the Monte-Carlo method and a multi-variant regression. Results show that the correction term has a linear relationship with the Stefan number and is not significantly influenced by the Biot number. The proposed modified perturbation solution can accurately and rapidly predict the nonlinear moving interface motion for the freezing process.

DIRECT ENERGY CONVERSION,MATHEMATICS AND COMPUTING↗

Multi-Scale Thermal Analysis for Design of SiC-Based Medium Voltage Motor Drive: Preprint

This paper describes a multi-scale thermal analysis approach for the design of an air-cooled 1.7-kV SiC MOSFET-based medium-voltage variable-speed motor drive. The National Renewable Energy Laboratory supported the project objectives by providing thermal management design support to the project partner The Ohio State University (OSU). The scope of the models and limited resources required efficient and flexible thermal models to be developed. Two modeling techniques are described that significantly reduced model run time and enabled more complex models to be run faster while retaining needed accuracy. The first technique uses the effectiveness-NTU method to extract convection boundary conditions from a computational fluid dynamics (CFD) model that can be applied to a fast-running finite element analysis model. The second is a porous media technique that enables system-level CFD simulations that incorporate effects from heat exchangers (e.g., pin fin heat sinks) that run in a fraction of the time required for fully resolved CFD simulations. The multi-scale approach to the thermal analysis enabled fast and accurate simulation for the converter design ranging from the die level up to the full system with 36 submodules. The modeling results were validated against experimental data from system tests performed by OSU.

DIRECT ENERGY CONVERSION↗

Thermal Optimization of a Silicon Carbide, Half-Bridge Power Module

This project describes the modeling process to design the packaging and heat exchanger for a half-bridge wide-bandgap (WBG) power semiconductor module. The module uses two silicon carbide, metal-oxide-semiconductor field-effect transistor (MOSFET) devices per switch position that are soldered to an aluminum nitride, direct-bond copper (DBC) substrate. A baseplate cooling configuration (e.g., no thermal grease) is used along with a water-ethylene glycol, jet-impingement-style heat exchanger. The heat exchanger was designed to be fabricated using prototyping equipment from the National Renewable Energy Laboratory, complies with automotive standards (for minimal channel sizes, flow rates, and coolant), and considers reliability aspects (i.e., erosion/corrosion). Device-scale computational fluid dynamics (CFD) is used first to design the slot jet impingement cooling configuration and compute the effective heat transfer coefficient (HTC) of the concept. The computed HTCs are then used as boundary conditions for a finite element study to optimize the package geometry (e.g., device layout and baseplate thickness) to minimize thermal resistance and minimize temperature variation between the module's four devices. Finally, a fluid manifold is designed to generate the slot jets and cool the devices. Module-scale CFD predicts a relatively low junction-to-fluid thermal resistance of 16.7 mm2 K/W, a 1.4 degrees C temperature variation between devices, and a total pressure drop of 5,860 Pa (0.85 psi) for the design. The thermal resistance of the module design is about 67% lower than the 2015 BMW i3 power electronics/modules thermal resistance.

DIRECT ENERGY CONVERSION↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Shepherding Metadata Through the Building Lifecycle

Many different digital representations of a building are produced over the course of its lifecycle. These representations contain the metadata required to support different stages of the building, from initial planning and design, to construction and commissioning, through operations, audits, retrofits and maintenance. However, because of differences in the semantics, structure and syntax of these representations, the metadata they contain is not interoperable. We present a novel method for leveraging these representations to create a unified, authoritative Brick metadata model for a building that can be continually maintained over the course of the building lifecycle. A simple synchronization protocol relays inferred Brick metadata from existing metadata sources such as gbXML, BuildingSync, Project Haystack and Modelica to a central integration server, which merges the metadata into a valid Brick model.

Fierro, Gabe↗

Investigating Effects of Operational Parameters on the Rate of Electrochemical Cleaning of Chromium Deposits on Strontium-Doped Lanthanum Manganite Cathodes in Solid Oxide Fuel Cells

Chromium poisoning of the cathode remains a significant obstacle to the stable long-term performance of solid oxide fuel cells. This study reports, a quick, in-situ mitigation method, called electrochemical cleaning. By applying a mild anodic bias, the electrochemical deposition reactions of chromium-containing species are reversed. Chromium vapor species are formed, freeing active electrochemical sites in the air electrode. An LSM/YSZ-based cell was exposed to Cr vapors at 800ºC and then subjected to electrochemical cleaning. Cell performance recovery was evidenced by current-voltage and EIS measurements. Chromium removal was verified using SEM and EDS analyses. The cyclability of the electrochemical cleaning was tested by repeated poisoning and cleaning of another cell. Investigation into the effect of cell operating parameters (current density and cell temperature) on the rate of cleaning is discussed.

30 DIRECT ENERGY CONVERSION↗