Search NASA⌕ Search

SEARCH · Search NASA

Results for “document filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Thirty-Day Outcome Following Carotid Artery Stenting: A 10-Year Experience from a Single Center

We aimed to present our experience with carotid angioplasty and stenting (CAS) and to document how the technique evolved over the last decade (1997-2007). A retrospective study of 333 patients (259 men; median age, 69 years) who underwent 336 CAS procedures. Of these, 118 (35%) patients were symptomatic and 164 (49%) lesions involved the left carotid bifurcation. The first 163 patients received a balloon-expandable stent, whereas the remaining 173 received a self-expandable one. Cerebral protection devices were used in the last 84 (25%) procedures. Access was via the femoral artery in all but six cases, in which direct puncture of the common carotid was necessary. The left common carotid originated from the innominate artery in 18 cases (5%). Conversion to open endarterectomy was necessary in two patients due to inability to remove the filter. Perioperative neurological events included stroke in 6 patients (1.8%), transient ischemic attack in 15 (4.5%), and hyperperfusion syndrome in 10 (3.0%). Three patients died during the first 30 days. As a result, the mortality and the combined stroke/death rate were 0.9 and 2.4%, respectively, with no differences between symptomatic and asymptomatic patients. Bradycardia was noted in 48 patients (14%), and hypotension in 45 (13%). Univariate analysis identified hypertension (P = 0.03), hyperlipidemia (P = 0.02), and current or ex-smoking (P = 0.02) as significant risk factors for death/stroke. On multivariate analysis using logistic regression, only hyperlipidemia [odds ratio (OR), 53.90; 95% confidence interval (CI), 4.19-693.47; P = 0.002] and current or ex-smoking (OR, 63.84; 95% CI,: 4.80-848.68; P = 0.001) remained statistically significant. In conclusion, CAS can be performed safely and effectively, with acceptable mortality, stroke/death, and cardiovascular complication rates. Although technological advances (stent design, cerebral protection devices), perioperative pharmacological management, and increasing experience are all clinically significant factors influencing the short-term results, none appeared to be statistically significant in this patient sample.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

This paper describes the physics design of a 100 keV, 60 A H{sup -} accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

43 PARTICLE ACCELERATORS↗

Space Trajectory Error Analysis Program (STEAP) for halo orbit missions. Volume 2: Programmer's manual

The six month effort was responsible for the development, test, conversion, and documentation of computer software for the mission analysis of missions to halo orbits about libration points in the earth-sun system. The software consisting of two programs called NOMNAL and ERRAN is part of the Space Trajectories Error Analysis Programs. The program NOMNAL targets a transfer trajectory from earth on a given launch date to a specified halo orbit on a required arrival date. Either impulsive or finite thrust insertion maneuvers into halo orbit are permitted by the program. The transfer trajectory is consistent with a realistic launch profile input by the user. The second program ERRAN conducts error analyses of the targeted transfer trajectory. Measurements including range, doppler, star-planet angles, and apparent planet diameter are processed in a Kalman-Schmidt filter to determine the trajectory knowledge uncertainty.

Byrnes, D. V.↗

Photoluminescence of patterned CdSe quantum dot for anti-counterfeiting label on paper

We successfully developed a method utilizing colloidal CdSe nanocrystalline quantum dot for anti-counterfeiting label on a piece of glossy paper. We deposited numbers and lines patterns of toluene soluble CdSe quantum dot using rubber stamper on a glossy paper. The width of line pattern was about 1-2 mm with 1-2 mm separation between lines. It required less than one minute for deposited CdSe quantum dot on glossy paper to dry and become invisible by naked eyes. However, patterned quantum dot become visible using long-pass filter glasses upon excitation of UV lamp or blue laser. We characterized photoluminescence of line patterns of quantum dot, and we found that emission boundaries of line patterns were clearly observed. The error of line size and shape were mainly due to defect of the original stamper. The emission peak wavelength of CdSe quantum dot was 629 nm. The emission spectrum of deposited quantum dot has full width at half maximum (FWHM) of 30-40 nm. The spectra similarity between deposited quantum dot and the original quantum dot in solution proved that our stamping method can be simply applied on glossy paper without changing basic optical property of the quantum dot. Further development of this technique is potential for anti-counterfeiting label on very important documents or objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A parameter estimation subroutine package

Linear least squares estimation and regression analyses continue to play a major role in orbit determination and related areas. In this report we document a library of FORTRAN subroutines that have been developed to facilitate analyses of a variety of estimation problems. Our purpose is to present an easy to use, multi-purpose set of algorithms that are reasonably efficient and which use a minimal amount of computer storage. Subroutine inputs, outputs, usage and listings are given along with examples of how these routines can be used. The following outline indicates the scope of this report: Section (1) introduction with reference to background material; Section (2) examples and applications; Section (3) subroutine directory summary; Section (4) the subroutine directory user description with input, output, and usage explained; and Section (5) subroutine FORTRAN listings. The routines are compact and efficient and are far superior to the normal equation and Kalman filter data processing algorithms that are often used for least squares analyses.

Bierman, G. J.↗

Operation of the ATLAS trigger system in Run 2

The ATLAS experiment at the Large Hadron Collider employs a two-level trigger system to record data at an average rate of 1 kHz from physics collisions, starting from an initial bunch crossing rate of 40 MHz. During the LHC Run 2 (2015–2018), the ATLAS trigger system operated successfully with excellent performance and flexibility by adapting to the various run conditions encountered and has been vital for the ATLAS Run-2 physics programme. For proton-proton running, approximately 1500 individual event selections were included in a trigger menu which specified the physics signatures and selection algorithms used for the data-taking, and the allocated event rate and bandwidth. The trigger menu must reflect the physics goals for a given data collection period, taking into account the instantaneous luminosity of the LHC and limitations from the ATLAS detector readout, online processing farm, and offline storage. This document discusses the operation of the ATLAS trigger system during the nominal proton-proton data collection in Run 2 with examples of special data-taking runs. Aspects of software validation, evolution of the trigger selection algorithms during Run 2, monitoring of the trigger system and data quality as well as trigger configuration are presented.

43 PARTICLE ACCELERATORS↗

Space Trajectory Error Analysis Program (STEAP) for halo orbit missions. Volume 1: Analytic and user's manual

Development, test, conversion, and documentation of computer software for the mission analysis of missions to halo orbits about libration points in the earth-sun system is reported. The software consisting of two programs called NOMNAL and ERRAN is part of the Space Trajectories Error Analysis Programs (STEAP). The program NOMNAL targets a transfer trajectory from Earth on a given launch date to a specified halo orbit on a required arrival date. Either impulsive or finite thrust insertion maneuvers into halo orbit are permitted by the program. The transfer trajectory is consistent with a realistic launch profile input by the user. The second program ERRAN conducts error analyses of the targeted transfer trajectory. Measurements including range, doppler, star-planet angles, and apparent planet diameter are processed in a Kalman-Schmidt filter to determine the trajectory knowledge uncertainty. Execution errors at injection, midcourse correction and orbit insertion maneuvers are analyzed along with the navigation uncertainty to determine trajectory control uncertainties and fuel-sizing requirements. The program is also capable of generalized covariance analyses.

Byrnes, D. V.↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

Global Assimilation of L-Band Brightness Temperature Observations from SMAP and SMOS into the Catchment Land Surface Model and Contribution to the Skill of Soil Moisture Estimates

The Soil Moisture Active Passive (SMAP) and Soil Moisture Ocean Salinity (SMOS) missions provide global observations of L-band (1.4 GHz) passive microwave brightness temperature (Tb) observations at a resolution of ~40 km every 2-3 days. These observations have been available since 2015 from SMAP and since 2010 from SMOS.Soil moisture estimates from the separate assimilation of SMAP and SMOS Tb observations into land surface models were previously shown to improve over model-only estimates, thereby demonstrating the value of assimilating L-band Tb observations for soil moisture estimation. The assimilation experiments documented in the literature do not, however, establish whether the joint assimilation of SMAP and SMOS Tbs improves the skill of the resulting soil moisture estimates beyond what can be achieved with either set of observations alone. Moreover, because the published SMAP and SMOS results used different assimilation systems and configurations and applied different evaluation data and procedures, it is unclear whether the assimilation of SMAP-only or SMOS-only Tbs results in better soil moisture skill. In this presentation, we compare the results of three separate assimilation experiments for the period from April 2015 to present. The experiments utilize the SMAP Level-4 Soil Moisture (L4_SM) algorithm, which assimilates L-band Tb observations into the NASA Catchment land surface model using a spatially distributed ensemble Kalman filter. Specifically, the three experiments presented here assimilate (i) SMAP Tbs only, as in the L4_SM product, (ii) SMOS Tbs only, after interpolation of 40° incidence angle, and (iii) both SMAP and SMOS Tbs. In all other respects, the configuration of three experiments is identical, as is the validation of the output. Preliminary results suggest that the joint assimilation of SMAP and SMOS Tbs yields the most skillful soil moisture estimates when compared to independent in situ measurements. Moreover, the skill of the SMAP-only assimilation exceeds that of the SMOS-only assimilation. The presentation provides an in-depth evaluation of the skill of the assimilation estimates vs. independent in situ and satellite measurements and in terms of statistics of the observation-minus-forecast residuals and analysis increments.

Reichle, Rolf↗

Solid Collection Efforts: Ta Collimator Evaluation

Ta collimator sets that were part of the gated x-ray detector diagnostic (GXD) at NIF were analyzed for debris distribution and damage in 2011. These disks (ranging in thickness from 250 to 750 {mu}m) were fielded approximately 10 cm from target chamber center (TCC) on various symcap, THD and re-emit shots. The nose cone holder and forward Ta collimator (facing target chamber center, TCC) from all shots show evidence of surface melt. Non-destructive analysis techniques such as optical microscopy, surface profilometry, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and x-ray fluorescence (XRF) were used to determine debris composition and degree of deformation associated with each Ta disk. Molten debris from the stainless steel nose cone contaminated the surface of the collimators along with other debris associated with the target assembly (Al, Si, Cu, Au and In). Surface elemental analysis of the forward collimator Ta disks indicates that Au hohlraum debris is less concentrated on these samples versus those fielded 50 cm from TCC in the wedge range filter (WRF) assembly. It is possible that the Au is distributed below or within the stainless steel melt layer covering the disk, as most of the foreign debris is captured in the melted coating. The other disks (fielded directly behind the forward collimator in a sandwiched configuration) have visible forms of deformation and warping. The degree of warping increases as the shock wave penetrates the assembly with the most damage sustained on the back collimator. In terms of developing a solid collection capability, the collimator analyses suggests that close proximity may cause more interference with capsule debris collection and more damage to the surface of the collector diagnostic. The analyses of the Ta collimators were presented to the Target and Laser Interaction Sphere (TaLIS) group; a representative presentation is attached to this document.

36 MATERIALS SCIENCE↗

Classifier-Guided Sampling for Complex Energy System Optimization

This report documents the results of a Laboratory Directed Research and Development (LDRD) effort entitled “Classifier-Guided Sampling for Complex Energy System Optimization” that was conducted during FY 2014 and FY 2015. The goal of this project was to develop, implement, and test major improvements to the classifier-guided sampling (CGS) algorithm. CGS is type of evolutionary algorithm for performing search and optimization over a set of discrete design variables in the face of one or more objective functions. Existing evolutionary algorithms, such as genetic algorithms, may require a large number of objective function evaluations to identify optimal or near-optimal solutions. Reducing the number of evaluations can result in significant time savings, especially if the objective function is computationally expensive. CGS reduces the evaluation count by using a Bayesian network classifier to filter out non-promising candidate designs, prior to evaluation, based on their posterior probabilities. In this project, both the single-objective and multi-objective versions of the CGS are developed and tested on a set of benchmark problems. As a domain-specific case study, CGS is used to design a microgrid for use in islanded mode during an extended bulk power grid outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning Models for Planetary Seismicity Detection

Research in planetary seismology is fundamentally constrained by a lack of data. Seismo-logical science products of future missions can typically only be informed by theoretical signal/noise characteristics of the environment or likely Earth-analogues. Although objectives can be re-assessed after some initial data-collection upon lander arrival, transfer of high-resolution data back to Earth is costly on lander power usage. Over the last several years, development of GPU computing techniques and open-source high-level APIs have led to rapid advances in deep learning within the fields of computer vision, natural language processing, and collaborative filtering. These techniques are actively being adapted in seismology for a variety of tasks, including: earthquake detection, seismic phase discrimination, and ground-motion prediction. Until the recent detection of mars quakes during the Mars InSight mission, the only other measurements of seismicity recorded outside of Earth was on the Moon during the Apollo missions between 1969 to 1977. These unique data sets have been periodically revisited using new seismological methods, including ambient noise interferometry and Hidden Markov Models. Our objective is to develop a deep learning seismic detector and use it to catalog moonquakes from the Apollo 17 Lunar Seismic Profiling Experiment (LSPE) and compare the results with those obtained by other methods. Additionally, we will assess the accuracy tradeoff between using a training set of lunar data and one composed of Earth seismicity. In this document, we present preliminary results using a prototype classifier trained on a small set of earthquakes that was able to obtain detections for LSPE moonquakes with a greater accuracy than a recent study using Hidden Markov Models.

Civilini, F.↗

Development of a One-Domain Volume-Averaged Navier–Stokes Solver

The interaction between a high-enthalpy flow and a thermal protection material is inherently multiscale and multiphysics. In conventional aerothermal analyses, the external flow and material response are generally modeled using separate computational domains coupled through boundary conditions at the material surface. Although this approach has supported many practical applications, it requires assumptions about the location and behavior of the interface and may become difficult to apply when material decomposition, internal reactions, and surface recession substantially alter the porous structure. This report presents the development of a one-domain formulation in which the free-fluid and porous-material regions are represented within a single computational domain. The formulation is based on the volume-averaged Navier–Stokes (VANS) equations, derived from the governing equations for reacting, compressible flow and condensed material. Volume averaging transfers the influence of the unresolved material microstructure to the macroscale equations through effective transport properties, interfacial source terms, and dispersion fluxes. Particular attention is given to regions in which porosity and permeability vary rapidly, including the diffuse transition between a porous material and the surrounding fluid. The resulting equations are implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO). The report describes the pressure–velocity coupling strategy used by the solver, examines spatial filtering techniques for deriving effective properties, and evaluates the influence of a smoothly varying interface permeability. Numerical demonstrations include canonical porous-flow configurations, a flow-tube configuration representative of FiberForm® permeability experiments, and the oxidation of a porous carbon material. The purpose of this work is to establish a mathematical and computational foundation for a unified treatment of flow and thermal protection material response. The present formulation is intended to support the progressive inclusion of additional physical processes, including multicomponent transport, finite-rate gas–surface chemistry, pyrolysis, internal oxidation, and material recession. It also provides a framework for connecting pore-scale simulations and microstructural characterization with macroscale aerothermal-response calculations. This report is intended for researchers and engineers working in computational fluid dynamics, porous-media transport, material response, and thermal protection system modeling. It documents both the theoretical development and the initial numerical assessment of the one-domain approach, while identifying the closure of effective and dispersion terms as an important subject for continued investigation.

Ablation↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wavelet-Based Interpolation and Representation of Non-Uniformly Sampled Spacecraft Mission Data

A well-documented problem in the analysis of data collected by spacecraft instruments is the need for an accurate, efficient representation of the data set. The data may suffer from several problems, including additive noise, data dropouts, an irregularly-spaced sampling grid, and time-delayed sampling. These data irregularities render most traditional signal processing techniques unusable, and thus the data must be interpolated onto an even grid before scientific analysis techniques can be applied. In addition, the extremely large volume of data collected by scientific instrumentation presents many challenging problems in the area of compression, visualization, and analysis. Therefore, a representation of the data is needed which provides a structure which is conducive to these applications. Wavelet representations of data have already been shown to possess excellent characteristics for compression, data analysis, and imaging. The main goal of this project is to develop a new adaptive filtering algorithm for image restoration and compression. The algorithm should have low computational complexity and a fast convergence rate. This will make the algorithm suitable for real-time applications. The algorithm should be able to remove additive noise and reconstruct lost data samples from images.

Bose, Tamal↗