Search NASA⌕ Search

SEARCH · Search NASA

Results for “double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Influence of the space environment on some materials processing phenomena

The influence of the space environment on materials processing phenomena is studied by applying the principles of physical similarity to a system E on Earth and a system S in the microgravity environment of space. If these systems can be characterized by a set of dimensionless groups, then they are similar if corresponding members of the set are equal for E and S. Similarity is often impractical or impossible if Q is larger than a few samples. For example, there is a simple law of similarity for an isothermal liquid zone floating between inert solids; however, similarity is lost if the zone becomes nonisothermal. A molten zone during crystal growth is so complex that a complete set cannot be identified with certainty. A second example is double-diffusive convection during unidirectional solidification of a binary alloy. Results show that buoyancy driven fluid dynamical instabilities couple with constitutionally related instabilities quite differently in E and S.

Sekerka, R. F.↗

A tunable, solid, Fabry-Perot etalon for solar seismology

A solid etalon has been designed and fabricated from a 50-mm diameter wafer of optical-quality lithium niobate. The finished etalon has a free spectral range of 0.325 nm at 588 nm. The parallel faces are coated with silver, and the central 15-mm aperture of the etalon has a finesse of 18.6. The reflective faces double as electrodes, and application of voltage will shift the passband. This feature was used in a servo circuit to stabilize the passband against temperature and tilt-induced drifts to better than three parts in one billion. Operated in the stabilized mode for day-long sessions, this filter alternately samples the wings of a narrow atomic absorption line in the solar spectrum and produces a signal proportional to velocity on the solar disk. The Fourier transform of this signal yields information on acoustic waves in the solar interior.

Rust, David M.↗

Double-Knudsen-Cell Apparatus Measures Alloy-Component Activities

Double-Knudsen-cell apparatus provides molecular beam from selected one of two Knudsen cells. Both cells maintained at same temperature. Molecular beam directed into mass spectrometer for measurement of vapor pressure of selected material component. Designed to minimize undesired thermal gradients, provides appropriate translation to place selected cell in position for sampling, and minimizes mixing of molecular beams from cells.

Jacobson, Nathan S.↗

Spatial Distribution of Rolled up Kelvin-Helmholtz Vortices at Earth's Dayside and Flank Magnetopause

The Kelvin-Helmholtz Instability (KHI) can drive waves at the magnetopause. These waves can grow to form rolled-up vortices and facilitate transfer of plasma into the magnetosphere. To investigate the persistence and frequency of such waves at the magnetopause we have carried out a survey of all Double Star 1 magnetopause crossings, using a combination of ion and magnetic field measurements. Using criteria originally used in a Geotail study made by Hasegawa et al. (2006) (forthwith referred to as H2006), 17 candidate events were identified from the entire TC-1 mission (covering 623 orbits where the magnetopause was sampled), a majority of which were on the dayside of the terminator. The relationship between density and shear velocity was then investigated, to identify the predicted signature of a rolled up vortex from H2006 and all 17 events exhibited some level of rolled up behavior. The location of the events had a clear dawn-dusk asymmetry, with 12 (71 %) on the post noon, dusk flank suggesting preferential growth in this region.

dawn-dusk asymmetry↗

Establishing and Monitoring an Aseptic Workspace

When are aseptic operations necessary? In order to meet certain bioburden requirements, some components must undergo dry heat microbial reduction (DHMR) or other sterilizing procedures. If sensitive surfaces must be re-exposed after DHMR, this could compromise the bioburden levels. Recontaminating sterilized surfaces could be costly both in time by requiring repeated DHMR and risk to the hardware, which may not be compatible with repeated high temperature bakes. In order to prevent recontamination of the sensitive surfaces, an aseptic environment and sterile technique must be employed. Aseptic environments mean working in a space with almost no detectable bioburden in the air or on surfaces. Ideally, DHMR happens as late as possible to avoid requiring aseptic operations, as it can be considered a high-risk operations. Preparing the cleanroom for aseptic operations Establishing an ISO (International Organization for Standardization) class 5 space to minimize airborne particles. Maintain low bioburden in the cleanroom by using biocidal cleaners. Using multiple biocidal techniques decreases the likelihood of selecting for resistant microorganisms. 70% Isopropyl Alcohol (IPA) denatures the proteins in a microorganism (note: 70% IPA is better at killing microorganisms than 100% IPA) 7% hydrogen peroxide: damages DNA and proteins through oxygen radical damage. Ultraviolet-C (UV-C) lamps: causes crosslinking in DNA which prevents replication. Monitor cleanroom regularly for bioburden trending: Standard bioassay: Swab or wipe samples of cleanroom surfaces processed for colony forming unity (viable or spore selected); Rapid bioassay: Adenosine triphosphate (ATP) or Limulus amebocyte lysate (LAL) for a bioburden snapshot. High levels can signal an immediate re-cleaning before standard bioassay samples are taken. Airborne monitoring: Active (pulling air through a filter) or passive (particle fallout) for bioburden. Verify bioburden levels just before aseptic operation. Test hardware and cleanroom surfaces and air 3 days before the planned aseptic operation. Rapid bioburden just before aseptic operation to ensure room was not re-contaminated. Preparing personnel and tools: Personnel training. Everyone in the cleanroom: Standard cleanroom certification Everyone on the team: 1 day Planetary Protection overview. Aseptic operators only: Half-day aseptic operations training. Covers sterile garmenting/gloves, Sterile handling with a focus on contact transfer risk, tool/GSE preparation, and two-operator system for opening sterilized tools/components. Tool sterilization: All tools to be used during an aseptic operation need to be identified. Compatible tools are sterilized by DHMR or Autoclave. Double wrapped so that the exterior bag can be handled by a non-sterile operator, and the sterile. Tools that are not compatible with high heat do not come in contact with sensitive surfaces: either substitutes are found, or tools are isolated by wrapping in sterile foil. During an aseptic operation. Pre-task to make sure everyone understands the operations, who is handling what, and when the most critical surfaces will be exposed. Monitoring during the operation. Bioburden: active and passive airborne bioburden sampling, glove-tip dabs onto a plate after completion of operation (3 days for results). Particles: real time particle counter constantly running, with alarm for exceeding ISO 5 conditions.

aseptic processing↗

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect↗

Multiple nitrogen components in lunar soil sample 12023

Nitrogen is one of the enigmatic elements in lunar soils and breccias. The large range in (delta)N-15 values found within lunar soils was initially attributed to a secular increase in the N-15/N-14 ratio of 50 percent within the solar corona, and hence in the implanted nitrogen within the lunar regolith. However, more recent explanations have proposed a two (or many) component mixing model of solar wind nitrogen with some hypothetical non-solar components. Such components could include indigenous lunar nitrogen, nitrogen contained in interstellar grains in primitive meteorites, and magnetospheric nitrogen from the terrestrial atmosphere. To understand the makeup of multi-component mixtures it is advantageous to have carbon and noble gas data measured simultaneously, particularly in the case of lunar soils, where the solar wind is a likely fundamental contributor of nitrogen. To this end, a new nitrogen instrument was adapted to give some of the desired data in parallel. Conjoint measurements of N abundance and (delta)N-15 together with N/Ar-36 and Ar-36/Ar-38 ratios obtained during a stepped combustion of lunar soil 12023. The results are preliminary to a much more comprehensive investigation of well characterized fractions of the sample which we still have available from a previous study. Stepped combustion of a sample of 12023,7 yielded 94 ppm nitrogen with a (delta)N-15 = +22.2 percent, as well as the characteristic heavy-light-heavy pattern observed for lunar samples. The low temperature maximum was +75.1 percent at 550 C, the minimum at 800 C with (delta)N-15 = -16.7 percent and the high temperature (delta)N-15 peak is +90.6 percent at 1250 C. The major releases of nitrogen occurred between 650 C - 800 C in the form of a double peak; a third, substantial release occurred at 1150 C yielding 14.2 ppm of nitrogen coinciding with a small but recognizable drop in (delta)N-15 against a regularly increasing trend.

Brilliant, D. R.↗

Wide-Field Imaging Interferometry Spatial-Spectral Image Synthesis Algorithms

Developed is an algorithmic approach for wide field of view interferometric spatial-spectral image synthesis. The data collected from the interferometer consists of a set of double-Fourier image data cubes, one cube per baseline. These cubes are each three-dimensional consisting of arrays of two-dimensional detector counts versus delay line position. For each baseline a moving delay line allows collection of a large set of interferograms over the 2D wide field detector grid; one sampled interferogram per detector pixel per baseline. This aggregate set of interferograms, is algorithmically processed to construct a single spatial-spectral cube with angular resolution approaching the ratio of the wavelength to longest baseline. The wide field imaging is accomplished by insuring that the range of motion of the delay line encompasses the zero optical path difference fringe for each detector pixel in the desired field-of-view. Each baseline cube is incoherent relative to all other baseline cubes and thus has only phase information relative to itself. This lost phase information is recovered by having point, or otherwise known, sources within the field-of-view. The reference source phase is known and utilized as a constraint to recover the coherent phase relation between the baseline cubes and is key to the image synthesis. Described will be the mathematical formalism, with phase referencing and results will be shown using data collected from NASA/GSFC Wide-Field Imaging Interferometry Testbed (WIIT).

Lyon, Richard G.↗

A Common Origin of Normal Type Ia Supernovae Suggested by the Photometric Diversity

In recent years, with the increasing number of type Ia supernovae (SNe Ia) discovered soon after their explosions, a nonnegligible fraction of SNe Ia with early-excess emissions (EExSNe Ia) have been confirmed. In this paper, we present a total of 67 early-phase normal SNe Ia from published papers and ongoing transient survey projects to systematically investigate their photometric behaviors from very early time. We found that EExSNe Ia in our sample have longer rise and brighter peak luminosities compared to non-EExSNe Ia. Moreover, EExSNe Ia commonly have “tiny red bump” or “blue plateau” features in the early B − V color while non-EExSNe Ia show blueward evolution from the very beginning. Here, we propose that the thin He-shell double detonation scenario can phenomenologically explain the photometric diversities of normal SNe Ia considering different white dwarf–He-shell mass combinations and the viewing angle effect, implying a unified explosion mechanism of normal-type SNe Ia. To further verify the possible common origin of normal SNe Ia, systematical studies of multiband photometric and spectral properties of early-phase SNe Ia through the new-generation wide-field time-domain survey facilities and global real-time follow-up networks are highly needed.

Wu, Weiyu↗

Double galaxy redshifts and the statistics of small numbers

Tifft (1980, 1982) claimed that observations of double galaxies reveal a 72 km/s periodicity. Sharp showed that the 'periodicities' in the observations are completely consistent with the statistics of small numbers. Here it is shown that Tifft's statistical procedure would ascribe a periodicity to small sets of Gaussian random noise. Satisfying the null hypothesis that the observations are not samples drawn from a normal population would require the acquisition of at least an order of magnitude more data.

Newman, William I.↗

An electromagnetic/electrostatic dual cathode system for electron beam instruments

A method of providing cathode redundancy which consists of two fixed cathodes and uses electromagnetic and/or electrostatic fields to direct the electron beam to the electron optical axis is presented, with application to the cathode system of the Scanning Electron Microscope and Particle Analyzer proposed for NASA's Mariner Mark II Comet Rendezvous/Asteroid Flyby projected for the 1990s. The symmetric double deflection system chosen has the optical property that the image of the effective electron source is formed above the magnet assembly near the apparent position of the effective source, and it makes the transverse positions of the electron sources independent of the electron beam energy. Good performance of the system is found, with the sample imaging resolution being the same as for the single-axis cathode.

Bradley, J. G.↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

Vitamin E provides protection for bone in mature hindlimb unloaded male rats

The deleterious effects of skeletal unloading on bone mass and strength may, in part, result from increased production of oxygen-derived free radicals and proinflammatory cytokines. This study was designed to evaluate the ability of vitamin E (alpha-tocopherol), a free-radical scavenger with antiinflammatory properties, to protect against bone loss caused by skeletal unloading in mature male Sprague-Dawley rats. A 2 x 3 factorial design was used with either hindlimb unloading (HU) or normal loading (ambulatory; AMB), and low-dose (LD; 15 IU/kg diet), adequate-dose (AD; 75 IU/kg diet), or high-dose (HD; 500 IU/kg diet) vitamin E (DL-alpha-tocopherol acetate). To optimize the effects of vitamin E on bone, dietary treatments were initiated 9 weeks prior to unloading and continued during the 4-week unloading period, at which time animals were euthanized and blood and tissue samples were collected. Serum vitamin E was dose-dependently increased, confirming the vitamin E status of animals. The HD treatment improved oxidation parameters, as indicated by elevated serum ferric-reducing ability and a trend toward reducing tissue lipid peroxidation. Histomorphometric analysis of the distal femur revealed significant reductions in trabecular thickness (TbTh), double-labeled surface (dLS/BS), and rate of bone formation to bone volume (BFR/BV) due by HU. AMB animals on the HD diet and HU animals on the LD diet had reduced bone surface normalized to tissue volume (BS/TV) and trabecular number (TbN); however, the HD vitamin E protected against these changes in the HU animals. Our findings suggest that vitamin E supplementation provides modest bone protective effects during skeletal unloading.

NASA Discipline Musculoskeletal↗

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The genesis of starbursts and infrared emission in the centers of galaxies

We present 10.8-micron maps of the central regions of 21 IR-luminous galaxies. Each map, obtained using the NASA MSFC bolometer array at the IRTF, has a resolution of about 4 arcsec and spans typically 25 x 20 arcsec. Some of the galaxies have also been mapped at 12.5, 19.2, and 30/microns. The sample consists primarily of starburst galaxies but includes several Seyferts and LINERs. On average, the flux detected in each map is about 58 percent of that detected at 12 microns by IRAS. We see a variety of morphologies, including compact and elongated sources and more complex distributions exhibiting such features as kiloparsec-size rings and double lobes. The mid-IR radiation is emitted by dust particles, and for two of the galaxies we see spatial color variations attributable to the presence of very small grains and consistent with their depletion in the starbursts. The mid-IR emission traces the dust heated by the youngest stars. Comparison of the distributions of intense star formation and the dense neutral interstellar medium for eight of these galaxies demonstrates that the two are intimately linked.

Telesco, C. M.↗

Surface Terminations of LaAlO 3 Perovskite Nanoparticles as Viewed by Solid-State Nuclear Magnetic Resonance

Nanocrystal surfaces generally undergo reconstructions that differentiate them from the bulk structures, often in nontrivial ways. Understanding these terminations is critical across diverse fields, from heterogeneous catalysis to the formation of topological states and the synthesis of semiconductor nanomaterials. Determining surface structures is currently an interdisciplinary task, most often involving high-resolution electron microscopy and surface electron diffraction. These methods, however, do not provide a global view of the ensemble of structures present in a sample. Here, we show how surface-sensitive solid-state nuclear magnetic resonance (SSNMR) spectroscopy methods can bridge this gap. In this context, we investigated the surface structure of lanthanum aluminate (LaAlO 3 ) perovskite nanoparticles. Four distinct surface terminations have previously been observed for this material, but their relative abundances were unknown. Using an array of double- and triple-resonance SSNMR methods probing the relative proximities of surface 1 H, 27 Al, 17 O, and 139 La nuclei, we conclude the surface to be majority terminated (80%) by AlO x with substantial (20%) LaO x terminated regions.

Materials↗

Effects of thermomechanical processing on tensile and long-time creep behavior of Nb-1 percent Zr-0.1 percent C sheet

Effects of thermomechanical processing on the mechanical properties of Nb-1 wt. percent Zr-0.1 wt. percent C, a candidate alloy for use in advanced space power systems, were investigated. Sheet bars were cold rolled into 1-mm thick sheets following single, double, or triple extrusion operations at 1900 K. All the creep and tensile specimens were given a two-step heat treatment 1 hr at 1755 K + 2 hr 1475 K prior to testing. Tensile properties were determined at 300 as well as at 1350 K. Microhardness measurements were made on cold rolled, heat treated, and crept samples. Creep tests were carried out at 1350 K and 34.5 MPa for times of about 10,000 to 19,000 hr. The results show that the number of extrusions had some effects on both the microhardness and tensile properties. However, the long-time creep behavior of the samples were comparable, and all were found to have adequate properties to meet the design requirements of advanced power systems regardless of thermomechanical history. The results are discussed in correlation with processing and microstructure, and further compared to the results obtained from the testing of Nb-1 wt. percent Zr and Nb-1 wt. percent Zr-0.06 wt. percent C alloys.

Titran, Robert H.↗

Advanced 30/20 GHz multiple beam antenna for future communications satellites

The technologies which will be implemented in advanced satellite communications systems being studied by NASA and the intended coverage scenarios are described. The systems will function at 30/20 GHz with 2.5 GHz bandwidth for the uplink and downlink. Subfrequencies will have 500 MHz bandwidth and operations will include TDMA modes. Sample scan patterns are presented for the centerminous U.S. The signals will be broadcast from a multibeam offset Cassegrain reflector antenna to obtain a low sidelobe, wide angle scan. Three contiguous low sidelobe beams will be generated with a diplex feed cluster and a 19 element scanning beam-forming network. The same technology will be used to double the capacity of current 14/12 GHz satellites.

Chen, C. C.↗