Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Enhanced accuracy through ensembling of randomly initialized auto-regressive models for dynamical systems

Computational mechanics simulations using traditional finite element methods (FEM) require prohibitively expensive computational resources for real-time engineering applications, design optimization, and digital twin implementations. While machine learning (ML) surrogate models offer significant computational speedups, autoregressive ML models for time-dependent mechanical systems suffer from error accumulation that compromises long-term prediction reliability - a critical concern for engineering applications where accuracy over extended time horizons is essential for safety and performance assessments. Here, we propose a deep ensemble framework specifically designed to address this challenge in computational mechanics applications, where multiple ML surrogate models with random weight initializations are trained in parallel and their predictions aggregated during inference. This approach leverages statistical diversity to maximize information gain from a fixed set of training data and to mitigate error propagation, while maintaining the computational efficiency that makes ML surrogates attractive for engineering practice. We validate the framework on three representative problems spanning critical areas of computational mechanics: stress field evolution in heterogeneous microstructures under complex loading (relevant to advanced materials design and composite analysis), planetary-scale shallow water dynamics (applicable to environmental and geotechnical engineering), and Gray-Scott reaction-diffusion systems (relevant to mass transport and chemical process engineering). Across all test cases, the ensemble approach demonstrates consistent error reduction of 15-33% compared to individual models. The codes for this work are available on GitHub (https://github.com/Graham-Brady-Research-Group/AutoregressiveEnsemble_SpatioTemporal_Evolution).

autoregressive prediction↗

Influence of plasticizers on thermal and mechanical properties of biocomposite filaments made from lignin and polylactic acid for 3D printing

Polylactic acid (PLA) and organosolv lignin were mixed at different ratios and extruded to obtain PLA-lignin composite filaments. PLA was replaced with lignin up to 20 wt%. Two plasticizers (polyethylene glycol (PEG) 2000 and struktol TR451) were added in varying concentrations to enhance the properties of PLA_L20 (20% lignin in PLA) composite filaments. Furthermore, the effect of lignin in PLA, and PEG, and struktol in PLA_L20 composites was investigated via tensile test, differential scanning calorimetry, thermogravimetric analysis, scanning electron microscopy, Fourier transform infrared spectroscopy of the filaments, and dynamic mechanical analysis of 3D printed samples. A 2 wt% PEG was able to enhance both tensile stress and elongation at maximum load of PLA_L20 composite by 19% and 35%, respectively, whereas struktol TR451 was able to improve elongation at maximum load by 24%.

3D printing↗

An investigation of silicon carbide-water nanofluid for heat transfer applications.

Thermal conductivity and mechanical effects of silicon carbide nanoparticles uniformly dispersed in water were investigated. Mean size of SiC particles was 170 nm with a polydispersity of {approx}30% as determined from small-angle x-ray scattering and dynamic light scattering techniques. Room temperature viscosity of the nanofluids ranged from 2 to 3 cP for nominal nanoparticle loadings 4-7 vol %. On a normalized basis with water, viscosity of the nanofluids did not significantly change with the test temperature up to 85 C. Optical microscopy of diluted nanofluid showed no agglomeration of the nanoparticles. Thermal conductivity of the fluid was measured as a function of the nominal nanoparticle loading ranging from 1 to 7 vol %. Enhancement in thermal conductivity was approximately 28% over that of water at 7 vol % particle loadings under ambient conditions. Enhancements in thermal conductivities for the nanofluids with varying nanoparticle loadings were maintained at test temperatures up to 70 C. Results of thermal conductivity have been rationalized based on the existing theories of heat transfer in fluids. Implications of using this nanofluid for engineering cooling applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An ODE-Enabled Distributed Transient Stability Analysis for Networked Microgrids

Networked microgrid (NMG) exhibits noteworthy resiliency and flexibility benefits for the mutual support from neighboring microgrids. With high penetration of distributed energy resources (DERs) and the associated controls, the transient stability analysis of NMGs is of critical significance. To address the issues of computation burdens and privacy in the centralized transient analysis, this paper devises an ordinary differential equation (ODE)-enabled distributed transient stability (DTS) methodology for NMGs. First, an ODE-based microgrid model is established to capture the dynamics in the droop control of DERs as well as network and load. Further, a distributed DTS is devised for the ODE representation of an NMG, allowing a privacy-preserving transient analysis of each microgrid while accurately reconstructing the frequency dynamics under droop controls in all DERs. In conclusion, extensive tests are performed to verify the validity of the ODE-based microgrid model through both dynamic response and eigenvalue analysis, and the efficacy of the DTS algorithm in simulating the large signal responses and the frequent fluctuations in NMG.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computational study on the impact of gasoline-ethanol blending on autoignition and soot/NO x emissions under low-load gasoline compression ignition conditions

Here, in the present work, computational fluid dynamics (CFD) simulations of a single-cylinder gasoline compression ignition (GCI) engine are performed to investigate the impact of gasoline-ethanol blending on autoignition, nitrogen oxide (NO x ), and soot emissions under low-load conditions. In order to represent the test gasoline (RD5-87), a four-component toluene primary reference fuel (TPRF)+ethanol (ETPRF) surrogate (with 10% ethanol by volume; E10) is employed. A three-dimensional (3D) engine CFD model employing finite-rate chemistry with a skeletal kinetic mechanism (including NO x sub-mechanism), adaptive mesh refinement (AMR), and hybrid method of moments (HMOM) is adopted to capture the in-cylinder combustion phenomena and soot/NO x emissions. The engine CFD model is validated against experimental data for three gasoline-ethanol blends: E10, E30 and E100, with varying ethanol content by volume. Model validation is carried out for a broad range of start-of-injection (SOI) timings (−21, −27, −36, and −45 crank angle degrees (°CA) after top-dead-center (aTDC)) with respect to in-cylinder pressure, heat release rate, combustion phasing, NO x and soot emissions. For relatively later injection timings (−21 and −27 °CA aTDC), E30 yields higher amount of soot than E10; while the trend reverses for early injection cases (−36 and −45 °CA aTDC ). On the other hand, E100 yields the lowest amount of soot among all fuels irrespective of SOI timing. Further, E10 shows a non-monotonic trend in soot emissions with SOI timing: SOI-36>SOI-45>SOI-21>SOI-27, while soot emissions from E30 exhibit monotonic decrease with advancing SOI timing. NO x emissions from various fuels follow a trend of E10>E30>E100. On the other hand, NO x emissions increase as SOI timing is advanced for all fuels, with an anomaly for E10 and E100 where NO x decreases when SOI is advanced beyond −36 °CA aTDC. Detailed analysis of the numerical results is performed to investigate the soot/NO x emission trends and elucidate the impact of chemical composition and physical properties on autoignition and emissions characteristics.

Computational fluid dynamics↗

Coupled Mooring Analyses for the WEC-Sim Wave Energy Converter Design Tool: Preprint

A wave-energy-converter-specific time-domain modeling method (WEC-Sim) was coupled with a lumped-mass-based mooring model (MoorDyn) to improve its mooring dynamics modeling capability. This paper presents a verification and validation study on the coupled numerical method. First, a coupled model was built to simulate a 1/25 model scale floating power system connected to a traditional three-point catenary mooring with an angle of 120 between the lines. The body response and the tension force on the mooring lines at the fairlead in decay tests and under regular and irregular waves were examined. To validate and verify the coupled numerical method, the simulation results were compared to the measurements from a wave tank test and a commercial code (OrcaFlex). Second, a coupled model was built to simulate a two-body point absorber system with a chain-connected catenary system. The influence of the mooring connection on the point absorber was investigated. Overall, the study showed that the coupling of WEC-Sim and the MoorDyn model works reasonably well for simulating a floating system with practical mooring designs and predicting the corresponding dynamic loads on the mooring lines. Further analyses on improving coupling efficiency and the feasibility of applying the numerical method to simulate WEC systems with more complex mooring configuration are still needed.

16 TIDAL AND WAVE POWER↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Quinoa, Version 0.2

Quinoa is a set of computational tools that enables research and numerical analysis in fluid dynamics. At this time it remains a test-bed to experiment with various algorithms using fully asynchronous runtime systems. Currently, Quinoa consists of the following tools: (1) Walker, a numerical integrator for systems of stochastic differential equations in time. It is a mathematical tool to analyze and design the behavior of stochastic differential equations. It allows the estimation of arbitrary coupled statistics and probability density functions and is currently used for the design of statistical moment approximations for multiple mixing materials in variable-density turbulence. (2) Inciter, an overdecomposition-aware finite element field solver for partial differential equations using 3D unstructured grids. Inciter is used to research asynchronous mesh-based algorithms and to experiment with coupling asynchronous to bulk-synchronous parallel code. Two planned new features of Inciter, compared to the previous release (LA-CC-16-015), to be implemented in 2017, are (a) a simple Navier-Stokes solver for ideal single-material compressible gases, and (b) solution-adaptive mesh refinement (AMR), which enables dynamically concentrating compute resources to regions with interesting physics. Using the NS-AMR problem we plan to explore how to scale such high-load-imbalance simulations, representative of large production multiphysics codes, to very large problems on very large computers using an asynchronous runtime system. (3) RNGTest, a test harness to subject random number generators to stringent statistical tests enabling quantitative ranking with respect to their quality and computational cost. (4) UnitTest, a unit test harness, running hundreds of tests per second, capable of testing serial, synchronous, and asynchronous functions. (5) MeshConv, a mesh file converter that can be used to convert 3D tetrahedron meshes from and to either of the following formats: Gmsh, http://www.geuz.org/gmsh, Netgen, http://sourceforge.net/apps/mediawiki/netgen-mesher, ExodusII, http://sourceforge.net/projects/exodusii, HyperMesh, http://www.altairhyperworks.com/product/HyperMesh.

Bakosi, Jozsef↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification: Preprint

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed toverify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results,a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observedfailure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Reinforcement Learning for Volt- Var Control: A Novel Two-stage Progressive Training Strategy

This paper develops a reinforcement learning (RL) approach to solve a cooperative, multi-agent Volt-Var Control (VVC) problem for high solar penetration distribution systems. The ingenuity of our RL method lies in a novel two-stage progressive training strategy that can effectively improve training speed and convergence of the machine learning algorithm. In Stage 1 (individual training), while holding all the other agents inactive, we separately train each agent to obtain its own optimal VVC actions in the action space: fconsume, generate, do-nothingg. In Stage 2 (cooperative training), all agents are trained again coordinatively to share VVC responsibility. Rewards and costs in our RL scheme include (i) a system-level reward (for taking an action), (ii) an agent-level reward (for doing-nothing), and (iii) an agent-level action cost function. This new framework allows rewards to be dynamically allocated to each agent based on their contribution while accounting for the trade-off between control effectiveness and action cost. The proposed methodology is tested and validated in a modified IEEE 123-bus system using realistic PV and load profiles. Simulation results confirm that the proposed approach is robust and computationally efficient; and it achieves desirable volt-var control performance under a wide range of operation conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data distribution service-based interoperability framework for smart grid testbed infrastructure

This study presents the design and implementation of a communication and control infrastructure for smart grid operation. The proposed infrastructure enhances the reliability of the measurements and control network. The advantages of utilizing the data-centric over message-centric communication approach are discussed in the context of smart grid applications. The data distribution service (DDS) is used to implement a data-centric common data bus for the smart grid. This common data bus improves the communication reliability, enabling distributed control and smart load management. These enhancements are achieved by avoiding a single point of failure while enabling peer-to-peer communication and an automatic discovery feature for dynamic participating nodes. The infrastructure and ideas presented in this paper were implemented and tested on the smart grid testbed. A toolbox and application programing interface for the testbed infrastructure are developed in order to facilitate interoperability and remote access to the testbed. This interface allows control, monitoring, and performing of experiments remotely. Furthermore, it could be used to integrate multidisciplinary testbeds to study complex cyber-physical systems (CPS).

97 MATHEMATICS AND COMPUTING↗

Seismic and LOCA safety testing and analysis program for Westinghouse PWR fuel under end of life conditions

The NRC issued Information Notice - IN 2012-09 in June 2012 which challenges approved assumptions based on the beginning of life (BOL) conditions in seismic and LOCA analysis. Westinghouse manufactures a variety of PWR fuel designs, including 14*14, 15*15, 16*16 and 17*17 array, also different fuel lengths from 12 feet to 14 feet. The fuels are supplied to the cores designed by Westinghouse and Combustion Engineering, and other cores around world. To address IN 2012-09 efficiently and economically, Westinghouse and PWR Owner Groups launched a testing and analysis program funded by PWROG. The program planed testing and analysis matrices based on types of fuel designs. The testing plan includes grid crush tests, fuel assembly mechanical tests and flowing water damping tests. Applying modelling technique, the program will reduce the number of test and cost. The ultimate goal of the program is to generate fuel assembly EOL models for all fuel designs manufactured by Westinghouse and to be ready for any plant specific seismic and LOCA analysis to address NRC IN for EOL effect. The phase I of PWROG for EOL conditions has been completed and several conclusions are obtained. First, the gapped grids reduce grid dynamic stiffness, local impact stiffness and crush strength. Also, due to gapped grids, both the fuel assembly natural frequency and stiffness are reduced. Secondly, applying higher fuel assembly damping due to the flowing water effect can significantly reduce fuel assembly impact forces. However, during a seismic event the reactor coolant pumps may trip resulting in a coast-down. As such, reduced flow rates that occur during the pump coast-down must be considered. Thirdly, the analytical model representation of a reactor core adequately characterizes the core response under seismic and LOCA excitations. Static and dynamic structural test results of a fuel assembly compared with analytical predictions indicate that the fuel assembly lateral and axial structural behavior can be fully determined with finite element models. Fourthly, analyses for EOL fuel assemblies under seismic and LOCA loads demonstrate EOL effect and flowing water damping effect. With flowing water damping benefit, significant margin can be recovered for fuel assemblies with EOL conditions and under seismic loads.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Computational Methods to Characterize Panel Loading Conditions for Accelerated Testing

Panel cracking and degradation due to wind loading are known to have a detrimental effect on power output. Recreating these damaging conditions in a controlled experimental setting requires an understanding of the loads being generated at the panel surface as a function of both wind speed, wind direction, and panel orientation. To better understand these relationships, a computational fluid dynamics (CFD) simulation package was constructed using an open-source Python library for solving partial differential equations with the finite element method. This CFD package allows the simulated wind speed and panel orientation of a multi-panel array to be easily changed and provides the capability to measure the traction forces at discrete points along the sun-facing and ground-facing surface of an interior panel residing in the wake of one or more upstream panels. A parameter exploration was performed in which the panel angle was varied in even increments from -70 deg to 70 deg and the wind speed was varied from 2 to 30 m/s. During post processing, the measured traction along the panel surface was averaged spatially and interpreted as a time-varying signal, where further processing of this signal yielded the root mean square amplitude and a characteristic frequency associated with the loading. This study found that higher wind speeds are generally associated with increased amplitude of loading and that the panel orientation angle can significantly exacerbate or mitigate this loading. These outcomes are presented along with current work on higher-fidelity verification simulations and recommendations for performing accelerated experimental testing.

loading↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gear Test Assembly - Status Report FY2018

The gear test assembly completed testing in air and distilled water successfully under a range of loading conditions. An external torque sensor assembly was designed and added to confirm the torque readings provided by the Parker control system. Hand calculations were performed to determine the time range that the heaters could be turned on without exceeding the ASME Boiler and Pressure Vessel code Fatigue Stress Limits for 1,000,000 cycles. Transient computational fluid dynamics analyses were performed to determine the heater cycle on/off time. Steady state computational fluid dynamics analyses were performed to determine the final temperature distribution throughout the insulated assembly using a thinner but more effective insulation configuration. The initial heating tests were completed (without insulation installed) to check the heater control system. Testing of the argon pressurized seal chambers were performed and indicated the need for re-machining of several components to eliminate some leaks. Nondestructive examination of the gears continued successfully using eddy current and ultrasonic inspection techniques.

42 ENGINEERING↗