At least 361 records · Page 20

The Physics of Hard Spheres Experiment on MSL-1: Required Measurements and Instrument Performance

The Physics of HArd Spheres Experiment (PHaSE), one of NASA Lewis Research Center's first major light scattering experiments for microgravity research on complex fluids, flew on board the Space Shuttle's Microgravity Science Laboratory (MSL-1) in 1997. Using colloidal systems of various concentrations of micron-sized plastic spheres in a refractive index-matching fluid as test samples, illuminated by laser light during and after crystallization, investigations were conducted to measure the nucleation and growth rate of colloidal crystals as well as the structure, rheology, and dynamics of the equilibrium crystal. Together, these measurements support an enhanced understanding of the nature of the liquid-to-solid transition. Achievement of the science objectives required an accurate experimental determination of eight fundamental properties for the hard sphere colloidal samples. The instrument design met almost all of the original measurement requirements, but with compromise on the number of samples on which data were taken. The instrument performs 2-D Bragg and low angle scattering from 0.4 deg. to 60 deg., dynamic and single-channel static scattering from 10 deg. to 170 deg., rheology using fiber optics, and white light imaging of the sample. As a result, PHaSE provided a timely microgravity demonstration of critical light scattering measurement techniques and hardware concepts, while generating data already showing promise of interesting new scientific findings in the field of condensed matter physics.

Doherty, Michael P.↗

Octafluoropropane Concentration Dynamics on Board the International Space Station

Since activating the International Space Station s (IS9 Service Module in November 2000, archival air quality samples have shown highly variable concentrations of octafluoropropane in the cabin. This variability has been directly linked to leakage from air conditioning systems on board the Service Module, Zvezda. While octafluoro- propane is not highly toxic, it presents a significant chal- lenge to the trace contaminant control systems. A discussion of octafluoropropane concentration dynamics is presented and the ability of on board trace contami- nant control systems to effectively remove octafluoropro- pane from the cabin atmosphere is assessed. Consideration is given to operational and logistics issues that may arise from octafluoropropane and other halo- carbon challenges to the contamination control systems as well as the potential for effecting cabin air quality.

Perry, J. L.↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Dynamics of Single Chains of Suspended Ferrofluid Particles

We present an experimental study of the dynamics of isolated chains made of super-paramagnetic particles under the influence of a magnetic field. The motivation of this work is to understand if the chain fluctuations exist and, if it does, how does the fluctuation affect chain aggregation. We find that single chains strongly fluctuate and that the characteristic frequency of their fluctuations is inversely proportional to the magnetic field strength. The higher the field the lower the characteristic frequency of the chain fluctuations. In the high magnetic field limit, chains behave like rigid rods without any internal motions. In this work, we used ferrofluid particles suspended in water. These particles do not have any intrinsic magnetization. Once a magnetic field is applied, a dipole moment is induced in each particle, proportional to the magnetic field. A dipolar magnetic interaction then occurs between particles. If dipole-dipole magnetic energy is higher than the thermal energy, the result is a structure change inside the dipolar fluid. The ratio of these two energies is expressed by a coupling constant lambda as: lambda = (pi(a(exp 3))(chi(exp 2))(mu(sub 0))(H(sub 0))(exp 2))/18kT Where a is the particle radius, mu(sub 0) is the vacuum magnetic permeability, H(sub 0) the applied magnetic field, k the Boltzmann constant and T the absolute temperature. If lambda > 1, magnetic particles form chains along the field direction. The lateral coalescence of several chains may form bigger aggregates especially if the particle volume fraction is high. While many studies and applications deal with the rheological properties and the structural changes of these dipolar fluids, this work focuses on the understanding of the chain dynamics. In order to probe the chain dynamics, we used dynamic light scattering (DLS) in self-beating mode as our experimental technique. The experimental geometry is such that the scattering plane is perpendicular to the magnetic field. Therefore, only motions in this plane are probed. A very dilute sample of a ferrofluid emulsion with a particle volume fraction of 10(exp -5) is used in this experiment. We chose such a low volume fraction to avoid multiple light scattering as well as lateral chain-chain aggregation. DLS measures the dynamic structure factor S(q,t) of the sample (q is the scattering wave vector, t is the time). In the absence of the magnetic field, identical particles of ferrofluid droplets are randomly distributed and S(q,t) reduces to exp(-q(exp 2)2D(sub 0)t). D(sub 0)=(kT/(6(pi)(eta)(a)) is the diffusion coefficient of Brownian particles (where Xi = (6(pi)(eta)(a)) is the Stokes frictional coefficient of a spherical particle in a fluid of viscosity eta). If interactions or polydispersity can not be ignored, an effective diffusion coefficient is introduced. Formally, D(sub eff) is defined as: D(sub eff) = - q(exp -2) partial derivative of (ln(S(q,t)) with respect to time, as t goes to 0. D(sub eff) reduces to D(sub 0) if no interactions and only a few particles size are present. Therefore, we can use DLS to measure particle size. The particle radius was found to be a=0.23 mu m with 7% of polydispersity. In this case, if we vary the scattering angle theta (and so q) we do not have any change in the measured diffusion coefficient: it is q-independent. When a magnetic field is applied, particles aggregate into chains if lambda > 1. We first studied the kinetics of the chain formation when lambda = 406. At a fixed scattering angle, we measured diffusion coefficient D(sub eff) as a function of time. Experimentally, we find that D(sub eff) decreases monotonously with time. Physically, this means that chains are becoming longer and longer. Since we are only sensitive to motions in the scattering plane and since chains have their main axis perpendicular to this plane, the measured diffusion coefficient is the trans-verse diffusion coefficient. We can relate D(sub eff) to the mean number of particles per chain N(t) at a given time and to the diffusion coefficient of an isolated particle D(sub 0) as D(sub eff)=f(N(t))D(sub 0). Since f(N) is known from other recent work, N can be expressed as a function of the time. We found a square root dependency: N(t) proportional to the square root of t. As expected for very low volume fraction, this behavior is characteristic of a diffusion-limited aggregation as suggested by several authors and by our previous work. In this study, we focus on the dependence of the effective diffusion coefficient on the scattering angle and the magnetic field strength. After the magnetic field is applied (lambda = 406) for a long time, typically 6 hours, kinetics of chain formation becomes very slow. Chain size does not vary much over the next hour period. Thus, we can perform different interesting experiments. First, at a fixed magnetic field, we measure the effective diffusion coefficient as a function of the scattering angle (from 5 to 130 deg). Our results show that the measured diffusion coefficient increases linearly with the scattering angle: D(sub eff) proportional to q. If we do the same experiment for different lambda values, D(sub eff) depends on lambda as D(sub eff) proportional to lambda(exp -1/2). We also find for different lambda values that the same asymptotic D(sub eff) value is obtained when q approaches zero. The angle dependency of D(sub eff) suggests that an additional motion exists besides chain drifting. Chain size is constant during experiment, which was verified by measuring the same diffusion coefficient at the beginning and at the end of the angle switching. If chains are rigid, D(sub eff) is independent of q. Therefore, we found that D(sub eff) not only measures the motion of the entire chain but also its internal fluctuations. These internal motions are the fluctuations of the particles in the chain. To understand the q dependency of D(sub eff), let us look at the probing length used. In our study, the characteristic length scale probed is l=2pi/q which is in the range of 0.9<l/a<20. When l is much larger than the particle radius (l/a going to infinity) we are mainly sensitive to the center of mass diffusion of the chain. D(sub eff) is then the diffusion of the entire chain and depends only on N but not on q and lambda. The value D(sub eff) allows us to obtain the number of particles per chain N. In the opposite limit (i.e. l/a < 1), we are sensitive to motions on the size of individual particles. The main contributions to the measured diffusion coefficient come from internal motions of the chains (i.e. particles' fluctuations inside the chain). We investigated also the effect of the chain size on D(sub eff). For the same value of the magnetic interaction lambda and different chain sizes, we found that the slope of D(sub eff) versus q decreases when N increases as a power law D(sub eff) proportional to N(exp -0.7). This is an important behavior because this means that the longer the chain the slower its internal fluctuations besides the whole chain motion.

Cutillas, S.↗

A model study of potential sampling errors due to data scatter around expendable bathythermograph transects in the tropical Pacific

A linear multiple vertical-mode model described by McPhaden et al. (1988) is used to examine potential errors due to data scatter around expendable bathythermograph (XBT) transects in the tropical Pacific. Two methods of sampling are compared. In the first, the model was sampled along approximately straight lines of grid points corresponding to the mean positions of XBT tracks in the eastern, central, and western Pacific; in the second, the model was sampled again at the dates and locations of actual XTB casts for 1979-1983. The model indicates that the data scattered zonally around XBT transects in general can lead to about 2 dyn cm error in dynamic height in composite sections of XBT data. Errors larger than 2 dyn cm occurred in regions where XBT sample spacing in the zonal direction was insufficient to resolve Rossby wave variations in the model.

Mcphaden, Michael J.↗

Dynamics of groups around interacting double ellipticals: Measuring dark matter haloes

Binary galaxies, as binary stars, are important to measure masses, as suggested by Page (1952). Because three orbit parameters are measurable for galaxies at one instant of time, severe uncertainties remain in the orbit and mass determinations. These uncertainties can partly be overcome by statistical studies of selected samples and/or n-body simulations. Close double galaxies (and isolated galaxies) could also be useful to estimate dynamical masses if we can find test particles around them. Interacting elliptical pairs or dumb-bell galaxies are found with a large range, between 0-1200 km s(exp -1), of relative radial velocities. Standard 2-body orbit calculations, highly uncertain due to projection factors, suggest for the largest velocity differences very large galaxy masses, if the systems are bound and stationary. However, recent n-body simulations model these binaries as galaxies captured from hyperbolic orbits, requiring masses of order a few times 10(exp 11) solar maximum (Borne et al. 1988), but producing systems that are short lived. A different picture appears when we study observationally the dynamical mass of interacting double ellipticals using faint satellite galaxies. These satellites contribute little luminosity and, presumably, little mass to the system. The authors present results of two such groups, basically forming systems of test particles, around the dumb-bells NGC 4782/3 and IC 5049. They also briefly discuss the satellite group around the central dumb-bell in the cluster Sersic 40/6. Apparently, they detect large quantities of dark matter in the vicinity of these dumb-bell galaxies, because the system masses of approx. 4.5 times 10(exp 13) solar mass and 8 times 10(exp 13) solar mass for NGC 4782/3 and IC 5049, respectively, are quite high. Likewise, the mass of the Sersic 40/6 inner core is 7 times 10(exp 13) solar mass. The possibility that a common massive dark matter halo increases the merging times of these types of galaxies is suggested. Here, the authors assume H sub o = 100 km s (exp -1) Mpc(exp -1).

Quintana, H.↗

Dynamics of clusters of galaxies with central dominant galaxies. I - Galaxy redshifts

Optical redshifts are presented for a sample of 638 galaxies in the fields of the clusters Abell 85, DC 0107-46, Abell 496, Abell 2052, and DC 1842-63. The velocity histograms and wedge diagrams show evidence for a foreground sheet of galaxies in Abell 85 and background sheets of galaxies in DC 0107-46 and Abell 2052. The foreground group projected against the center of Abell 85 found by Beers et al. (1991) is confirmed. No evidence of substructure was found in Abell 496, Abell 2052, and DC 1842-63. The clusters have global velocity dispersions ranging from 551 km/s for DC 1842-63 to 714 km/s for A496, and flat dispersion profiles. Mass estimates using the virial theorem and the projected mass method range from 2.3 x 10 exp 14 solar masses for DC 0107-46 to 1.1 x 10 exp 15 solar masses for A85.

Malumuth, Eliot M.↗

Space Interferometry Mission: Dynamical Observations of Galaxies (SIMDOG)

Space Interferometry Mission (SIM) will be used to obtain proper motions for a sample of 27 galaxies; the first proper motion measurements of galaxies beyond the satellite system of the Milky Way. SIM measurements lead to knowledge of the full 6-dimensional position and velocity vector of each galaxy. In conjunction with new gravitational flow models, the result will be the first total mass measurements of individual galaxies. The project, includes developnient of powerful theoretical methods for orbital calculations. This SIM study will lead to vastly improved determinations of individual galaxy masses, halo sizes, and the fractional contribution of dark matter. Astronomers have struggled to calculate the orbits of galaxies with only position and redshift information. Traditional N-body techniques are unsuitable for an analysis backward in time from a present distribution if any components of velocity or position are not very precisely known.

Shaya, Edward J.↗

Dynamic Countermeasure Fabrics for Post-Spaceflight Orthostatic Intolerance

Aerospace orthostatic intolerance garments (OIG) have historically been pneumatic (e.g., NASA’s antigravity suit), an approach that inhibits mobility and requires connection to an air supply. Elastic compression garments, an alternative technology, are difficult to don/doff and cannot be worn in a noncompressive state, resulting in discomfort and usability challenges. This research evaluates a novel technology—contractile shape memory alloy (SMA) knitted actuators—that can enable low-profile, dynamic compression for an aerospace OIG. To characterize the functional capabilities of SMA knitted actuators, displacement control testing was conducted on 10 actuator samples with a range of geometric design parameters. Inactive (FI) and actuated forces (FA) were observed by repeatedly thermally cycling each sample at 0%, 15%, 30%, and 45% structural strain. Compression capabilities were approximated using medical compression hosiery standards and anthropometric data from a representative aerospace population (ANSUR 2012). Dynamic compression predictions reached 52 mmHg (single layer fabric) and 105 mmHg (double layer fabric) at the ankle. Low, inactive pressures (p, 20 mmHg) demonstrate that compression is controllable and can be dynamically increased upon actuation up to 33 mmHg in a single layer system and up to 67 mmHg in a double layer system. The results highlight the potential of SMA knitted actuators to enable low-profile, dynamic compression garments that can reach medically therapeutic pressures on an aerospace population to counteract OI symptoms. In addition to astronautic applications, this technology demonstrates widespread terrestrial medical and high-performance aircraft applicability.

Orthostatic intolerance↗

Summary of activities

Four space projects' activities are summarized. Design work on the Mars Penetrator Project, in cooperation with the NASA Ames Research Center, is being continued. Efforts are focused on the drilling mechanism which must penetrate the martian subsurface soil to collect and retrieve an uncontaminated sample. The new design consists of a rotary-percussive drill mechanism. This mechanism is optimum for dry drilling, necessary to avoid contamination of the soil sample, in many different soil types. The need for a small, relatively inexpensive device to study the chemical structure of this martian soil was also established. The egg design was chosen for its low cost compared to other systems and potential for a large number of eggs to be deployed on the martian surface. The design process included analysis of the dynamics of reentry, dissipation of heat during reentry, impact with the surface, access to undisturbed soil samples, and ability to gather samples from the soil at three depths. The egg consists of the reentry systems, soil probe lifting system, soil probe package, gas chromatograph, transmitter, and battery power supply. The egg must function only once, but is designed to withstand one martian year. The Mars Mole is designed as a rover-based device which penetrates the martian soil to a depth of up to 10 m, obtains a sample of soil, and returns it to the surface for analysis. The mole was designed to meet the following specifications: (1) weight less than 10 kg; (2) size less than 20 x 20 x 30 cm; (3) power less than 100 W; (4) ability to obtain a sample of at least 5 cc; (5) ability to penetrate fine, loose sand; and (6) need to obtain at least one sample. The space station umbilical connector project is a device which provides the translational motion of the connectors on the Space Station Freedom to allow engagement for power and data transfer. The design is capable of delivering a 20 lb force within the necessary tolerances and will operate reliably in the space environment.

Source record↗

NASA Tech Briefs, September 2009

opics covered include: Filtering Water by Use of Ultrasonically Vibrated Nanotubes; Computer Code for Nanostructure Simulation; Functionalizing CNTs for Making Epoxy/CNT Composites; Improvements in Production of Single-Walled Carbon Nanotubes; Progress Toward Sequestering Carbon Nanotubes in PmPV; Two-Stage Variable Sample-Rate Conversion System; Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas; Board Saver for Use with Developmental FPGAs; Circuit for Driving Piezoelectric Transducers; Digital Synchronizer without Metastability; Compact, Low-Overhead, MIL-STD-1553B Controller; Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM; Differential InP HEMT MMIC Amplifiers Embedded in Waveguides; Improved Aerogel Vacuum Thermal Insulation; Fluoroester Co-Solvents for Low-Temperature Li+ Cells; Using Volcanic Ash to Remove Dissolved Uranium and Lead; High-Efficiency Artificial Photosynthesis Using a Novel Alkaline Membrane Cell; Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays; Micro-Horn Arrays for Ultrasonic Impedance Matching; Improved Controller for a Three-Axis Piezoelectric Stage; Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water; Micro-Organ Devices; Nonlinear Thermal Compensators for WGM Resonators; Dynamic Self-Locking of an OEO Containing a VCSEL; Internal Water Vapor Photoacoustic Calibration; Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings; Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays; Improved Scanners for Microscopic Hyperspectral Imaging; Rate-Compatible LDPC Codes with Linear Minimum Distance; PrimeSupplier Cross-Program Impact Analysis and Supplier Stability Indicator Simulation Model; Integrated Planning for Telepresence With Time Delays; Minimizing Input-to-Output Latency in Virtual Environment; Battery Cell Voltage Sensing and Balancing Using Addressable Transformers; Gaussian and Lognormal Models of Hurricane Gust Factors; Simulation of Attitude and Trajectory Dynamics and Control of Multiple Spacecraft; Integrated Modeling of Spacecraft Touch-and-Go Sampling; Spacecraft Station-Keeping Trajectory and Mission Design Tools; Efficient Model-Based Diagnosis Engine; and DSN Simulator.

Source record↗

Containerless Liquid to Solid Nucleation Pathways in Two Representative Grades of Commercially Available Zirconium

Experimental measurements were conducted to determine the solid metal nucleation pathways of radiatively cooling, molten zirconium spheres of two different commercially available purity grades in a high-vacuum, high-temperature electrostatic levitator. The ensemble distribution of maximum undercooling temperatures was interpreted using Poisson statistics to determine the temperature dependence of the solid metal nucleation rate. For a sample of nominally 99.95% pure zirconium, the results are consistent with heterogeneous solid metal nucleation either on static catalyst particles at least ~30 nm diameter or on a surface coating. For a sample of nominally 99% pure zirconium, however, it appears that heterogeneous solid metal nucleation occurred either on a polydispersion of ~10 nm (mean diameter) static catalyst particles or on dynamic catalyst particles which precipitated from a solution which became supersaturated as the melt cooled. A quantitative analysis of the compositions of both samples suggests that the catalysts probably consisted of one or more of the following elements: niobium, molybdenum, hafnium, and oxygen.

containerless, nucleation, zirconium↗

On quasar evolution.

We examine the consequences for quasar statistics of a class of models describing the evolution of individual strong sources. The continuity equation for the change of density and luminosity with cosmological epoch determines the population, once a model for the evolution of an individual object is chosen. A dynamical model of spinning objects seems to agree satisfactorily with the present observational sample, both in density and in luminosity function; such a model requires that an individual object strongly brightens as time goes on. A genetic relationship between quasars and radio galaxies which qualitatively fits the observations is suggested by the model.

Cavaliere, A.↗

Modeling of human operator dynamics in simple manual control utilizing time series analysis

Time series analysis is applied to model human operator dynamics in pursuit and compensatory tracking modes. The normalized residual criterion is used as a one-step analytical tool to encompass the processes of identification, estimation, and diagnostic checking. A parameter constraining technique is introduced to develop more reliable models of human operator dynamics. The human operator is adequately modeled by a second order dynamic system both in pursuit and compensatory tracking modes. In comparing the data sampling rates, 100 msec between samples is adequate and is shown to provide better results than 200 msec sampling. The residual power spectrum and eigenvalue analysis show that the human operator is not a generator of periodic characteristics.

Agarwal, G. C.↗

Hydrogen partitioning in pure cast aluminum as determined by dynamic evolution rate measurements

Hydrogen in pure aluminum can be found in two different states. One is related to a presence in gas-filled pores, while the other state involves the formation of a solid solution between hydrogen and aluminum. The considered investigation is concerned with the distribution of the hydrogen between various states. A dynamic technique is employed to measure the evolution of hydrogen from commercially available samples of polycrystalline pure aluminum under ultrahigh vacuum conditions. The obtained data are compared with the results of a statistical analysis concerning the porosity in the cast aluminum. It was found that more than 99 pct of the hydrogen in the aluminum is located in large pores. Less than 1 pct of the hydrogen is partitioned between the solid solution and the small pores.

Outlaw, R. A.↗

Impact cratering and spall failure at gabbro

Both hypervelocity impact and dynamic spall experiments were carried out on a series of well-indurated samples of gabbro. The impact experiments carried out with 0.04 to 0.2g, 5-6 km/sec projectiles produced deci-centimeter-sized craters and demonstrated crater efficiencies of 6/10 to the - 9 g/erg, and order of magnitude greater than in metal and some two to three times that of previous experiments on less strong igneous rocks. Most of the crater volume (some 60 to 80%) is due to spall failure. Distribution of cumulative fragment number, as a function of mass of fragments with masses greater than 0.1 gram yield values of b = d(log10N sub f)dlog10(m)of -0.5 to -0.6, where N sub f is the cumulate number of fragments and m is the mass of fragments. These values are in agreement or slightly higher than those obtained for less strong rocks and indicate that a large fraction of the ejectra resides in a few large fragments.

Lange, M. A.↗

Impact cratering and spall failure of gabbro

Both hypervelocity impact and dynamic spall experiments were carried out on a series of well-indurated samples of gabbro. The impact experiments carried out with 0.04 to 0.2 g, 5-6 km/sec projectiles produced deci-centimeter-sized craters and demonstrated crater efficiencies of 6/10 to the -9 g/erg, and order of magnitude greater than in metal and some two to three times that of previous experiments on less strong igneous rocks. Most of the crater volume (some 60 to 80 percent) is due to spall failure. Distribution of cumulative fragment number, as a function of mass of fragments with masses greater than 0.1 gram yield values of b = d(log10N sub f)dlog10(m) of -0.5 to -0.6, where N sub f is the cumulate number of fragments and m is the mass of fragments. These values are in agreement or slightly higher than those obtained for less strong rocks and indicate that a large fraction of the ejecta resides in a few large fragments.

Lange, M. A.↗