Search NASA⌕ Search

SEARCH · Search NASA

Results for “electricity use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

To What Extent Will Decarbonization Deepen the Conversation Between Industry and the Grid?

Decarbonization - the transition away from un-mitigated fossil fuel combustion throughout the economy - requires big changes from both power and process systems. On the power system side, those changes are expected to include large increases in variable generation, e.g., from wind and solar, which has near-zero marginal costs and at large shares can produce infrequent but consequential energy droughts. On the process systems side, industries are investigating their options for direct and indirect electrification, the latter exemplified by replacing fossil fuel inputs with zero-carbon, energy-carrying chemicals like hydrogen and ammonia produced via electrochemical processes. The economic features of these changes within the larger context of power and process systems suggest that their realization could be accompanied by a paradigm shift in how industrial facilities interact with the grid. For example, the dominant type of demand participation in power markets could change from today's focus on load reductions at peak times to a new focus on shifting electricity use, enabled in part by large-scale product storage, to take advantage of renewable energy that would otherwise be curtailed and to avoid consumption during high-price energy droughts. This talk will describe these and other possible design and operational approaches from grid and industrial economic perspectives, culminating in an enumeration of open problems that lie at the interface of today and tomorrow's power and process systems.

co-design↗

Gas-phase activation of holmium tetranitrato complexes likely leads to formation of hydroxylated species through the loss of nitric acid, not water splitting

It has been observed that water can react with activated gas-phase lanthanide tetranitrato complexes ([Ln(NO3)4]-) to form a hydroxylated species. These reactions, which are proposed to involve water splitting, are observed for most -- but not all -- of the lanthanides. Thus, study of this system could yield insight into how small changes in electronic structure (through variation of the lanthanide species) influences water-splitting reactions, help guide development of new materials used to convert water to hydrogen using electricity. The mechanism proposed in the literature is: (Step 1) [Ln(NO3)4]- ? [LnO(NO3)3]- + ?NO2 (Step 2) [LnO(NO3)3]- + H2O ? [LnOH(NO3)3]- + ?OH The purpose of this study is to determine if the reaction mechanism really does involve splitting of water or proceeds through an alternative pathway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Categorizing Plug Load Solutions by Ease of Implementation

Plug loads account for a growing share of U.S. commercial building electricity use, projected to rise from 16% today to 21% by 2050. Managing these loads presents a substantial opportunity for reducing energy costs while providing additional operational benefits, such as improved asset management and occupant comfort. Despite their potential, plug loads are numerous, diverse, and highly occupant-dependent, making control challenging. This publication organizes plug load control strategies by level of effort, offering building owners and operators a staged approach to implement interventions ranging from smart outlets and automatic receptacle controls to behavioral strategies. By following these actionable steps, building stakeholders can reduce energy consumption, lower utility bills, and realize broader operational advantages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECAR-6576 Rev 0 MARVEL Secondary Support Structure Analysis

The Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor generates electricity using four Stirling cycle engines. Each Stirling engine, along with its mounting system, is called a Secondary Support Structure (SSS). An individual SSS consists of a Secondary Output Structure (SOS), a Secondary Support Structure Base, an insulation block, and assorted hardware. The SOS consists of the Stirling engine, the Secondary Output Structure Ring, a vibration isolator, and hardware. The purpose of this analysis is to show that the SSS is appropriately designed to meet structural, mechanical, and maintenance requirements for specified operating conditions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Understanding electric vehicle ownership using data fusion and spatial modeling

The global shift toward electric vehicles (EVs) for climate sustainability lacks comprehensive insights into the impact of the built environment on EV ownership, especially in varying spatial contexts. This study, focusing on New York State, integrates data fusion techniques across diverse datasets to examine the influence of socioeconomic and built environmental factors on EV ownership. The utilization of spatial regression models reveals consistent coefficient values, highlighting the robustness of the results, with the Spatial Lag model better at capturing spatial autocorrelation. Further, results underscore the significance of charging stations within a 10-mile radius, indicative of a preference for convenient charging options influencing EV ownership decisions. Factors like higher education levels, lower rental populations, and concentrations of older population align with increased EV ownership. Utilizing publicly available data offers a more accessible avenue for understanding EV ownership across regions, complementing traditional survey approaches.

33 ADVANCED PROPULSION SYSTEMS↗

A study of electroactive polyvinyl chloride (PVC) gel actuators through the use of the electric modulus formalism and cyclic linear voltage sweeps

The conductivity and dielectric properties are integral to the function of polyvinyl chloride (PVC) gel actuators. The frequency-dependent properties of PVC gel actuators are investigated here in terms of their impedance, permittivity, and for the first time, electric modulus. The data shows that PVC gels’ conductive properties are just as, if not more, important as their dielectric properties in electromechanical transduction applications. The electrode polarization (EP) and its impact on the impedance and dielectric spectra of PVC gels, as well as the developed asymmetric space charge at the anode, are discussed. The electric modulus and tan δ spectra are used for the fitting of Cole-Cole (CC) and Debye relaxation models for gels of varying plasticizer content. The electrostatic adhesive force for PVC gels of varying plasticizer is also measured, indicating large electrostatic adhesion (>2 N cm -2 ). A cyclic linear voltage sweep is used to clarify the dynamics of space charge within the gels. The peak current (associated with space charge development) is seen to be concurrent with the onset of mechanical deformation, showing the asymmetric charge as the origin of electromechanical transduction. Additionally, the maximum charge transferred (as measured by the integration of current over time) before space charge development is found to correlate with the electrostatic adhesive force measured for the gels, pointing to a new method of characterizing PVC gels for actuation.

Instruments & Instrumentation↗

Piezoelectric-triboelectric heel charger to generate electricity from locomotion using level mechanism and mechanical SSHI boosting circuit

The disclosure provides an electricity generating insert for a piece of footwear, the insert can be removably placed in the heel portion, e.g. under the insole. The insert comprises a multilayer piezoelectric stack that alternatively flexes under the compression-decompression that occurs during locomotion, which flexing causes friction in the stack to generate electricity capable of charging electronic devices and the like, e.g. via a port on the footwear.

Wang, Ya↗

Quantitative time-resolved diagnostics of electric field dynamics during individual plasma breakdown events using burst laser pulse electric field induced second harmonic generation

In plasma discharges, the acceleration of electrons by a fast varying electric field and the subsequent collisional electron energy transfer determines the plasma dynamics, chemical reactivity, and breakdown. Current in situ electric field measurements require reconstruction of the temporal profile over many observations. However, such methods are unsuitable for non-repetitive and unstable plasmas. Here, in this paper, we present a method for creating “movies” of dynamic electric fields in a single acquisition at sample rates of 500 × 10 6 fps. This ultrafast diagnostic was demonstrated in radio frequency electric fields between two parallel plates in air, as well as in Ar nanosecond-pulsed single-sided dielectric barrier discharges.

42 ENGINEERING↗

Identification of hot water end-use process of electric water heaters from energy measurements

This paper presents an algorithm for the identification of parameters for a stochastic hot water end-use process that drives a homogeneous population of thermostatically controlled electric water heaters (EWH). Usually, only metered interval consumption data (kWh) is collected and the hot water end-use process is unobservable to utility and aggregators. However, the availability of EWHs for demand response (DR) is closely coupled with the hot water end-use process. In this context, the hot water end-use process is modeled as a two-state Markov chain (Use / No use), which causes the thermostatic ON-OFF switching process to behave as a Markov renewal process (MRP). A set of first passage-time problems is developed to obtain the moments of the transition probability densities of the MRP. These problems are addressed by establishing a system of coupled partial differential equations characterizing the temperature evolution of the EWH population. A key quantity in the methodology for estimating the parameters is the total time an EWH is ON within a period of interest. It is referred to as the total busy time. Total busy time in this approach is a random variable for which analytical expressions of the moments are developed as a function of the metered window length. The latter expressions become the basis of a hot water demand model identification algorithm which is validated using agent-based simulations of EWHs.

42 ENGINEERING↗

Land-use intensity of electricity production and tomorrow’s energy landscape

The global energy system has a relatively small land footprint at present, comprising just 0.4% of ice-free land. This pales in comparison to agricultural land use– 30–38% of ice-free land–yet future low-carbon energy systems that shift to more extensive technologies could dramatically alter landscapes around the globe. The challenge is more acute given the projected doubling of global energy consumption by 2050 and widespread electrification of transportation and industry. Yet unlike greenhouse gas emissions, land use intensity of energy has been rarely studied in a rigorous way. Here we calculate land-use intensity of energy (LUIE) for real-world sites across all major sources of electricity, integrating data from published literature, databases, and original data collection. We find a range of LUIE that span four orders of magnitude, from nuclear with 7.1 ha/TWh/y to dedicated biomass at 58,000 ha/TWh/y. By applying these LUIE results to the future electricity portfolios of ten energy scenarios, we conclude that land use could become a significant constraint on deep decarbonization of the power system, yet low-carbon, land-efficient options are available.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed electric field sensing using fibre optics in borehole environments

In the past decade, rapid advances in distributed optical fibre sensing technologies have made it possible to record various geophysical data (e.g. strain, temperature and pressure) continuously in both time and space along the fibre, providing an unprecedented quantity and spatial density of data compared to traditional geophysical measurements as well as reducing data acquisition cost. To date, no distributed fibre-based electromagnetic field sensing system has been implemented although electromagnetic sensing could have a broad range of applications to geophysical imaging and monitoring in borehole environments. The goal of this paper is to provide a theoretical feasibility study regarding the design and use of an electromagnetic sensing optical fibre for geophysical applications. First, we present the sensitivity analysis of a ‘hypothetical’ optical fibre coated with polyvinylidene fluoride, a polymer that provides relatively high piezoelectric properties, yet unlike ceramics, is flexible. Next, using a two-dimensional electromagnetic modelling algorithm, we simulate the earth electric-field-to-fibre-strain transfer function and estimate the theoretical sensitivity of the optical fibre to electric fields. Given the state-of-the-art distributed acoustic sensing strain sensitivities in the picometres strain range, our numerical modelling analysis suggests that a perfectly coupled polyvinylidene fluoride–coated optical fibre can measure electric field values in the mV/m to V/m amplitude range. We then apply a cylindrically symmetric modelling algorithm to simulate numerical models demonstrating the applicability of such a fibre in an oilfield environment. Scenarios investigated employ an electric field source and suggest that the measurements can be used to distinguish the oil versus water ratio with a fibre mounted inside a producing steel cased oil well as well as distinguishing between brine and hydrocarbon filled reservoir zones with a fibre located outside of the casing.

58 GEOSCIENCES↗

Analysis of the electrical double layer using electrochemical X-ray photoelectron spectroscopy

The element-sensitivity of X-ray spectroscopies offers the potential to disentangle the individual chemistries of water, ions, and adsorbates at the electrode-electrolyte interface in an element-by-element manner. However, targeted experimental design is needed to establish interface-sensitive in situ X-ray spectroscopy in a realistic electrochemical environment. Here, we demonstrate how electrochemical X-ray photoelectron spectroscopy (EC-XPS) in the dip-and-pull geometry can be used to specifically probe the behavior of ions in the electrical double layer. Taking the case study of a polycrystalline Au foil in 50 mM KClO 4 electrolyte, we tracked the electrochemical response of interfacial K + cations across a broad potential range. We show how, in combination with modeling, key parameters such as the potential of zero charge (PZC), ion packing behavior, dielectric saturation, and the electrostatic potential decay in the double layer can be extracted from the data. Importantly, we also analyze how the experimental conditions and non-idealities can influence the results and put forward criteria for reliable experimentation and data analysis.

Dip-and-pull↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗