Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Integrated transmission electron microscope

An integrated transmission electron microscope comprising multiple electron sources for tuned beams of ultrafast, scanning probe, and parallel illumination in varied beam energies can be alternated within sub-microseconds onto a sample with dynamic ‘transient state’ processes to acquire atomic-scale structural/chemical data with site specificity. The various electron sources and condenser optics enable high-resolution imaging, high-temporal resolution imaging, and chemical imaging, using fast-switching magnets to direct the different electron beams onto a single maneuverable objective pole piece where the sample resides. Such multimodal in situ characterization tools housed in a single microscope have the potential to revolutionize materials science.

Jungjohann, Katherine L.↗

Single-Shot Femtosecond Electron Diffraction with Laser-Accelerated Electrons: Experimental Demonstration of Electron Pulse Compression

We report the first experimental demonstration of longitudinal compression of laser-accelerated electron pulses. Accelerated by a femtosecond laser pulse with an intensity of 10{sup 18} W/cm{sup 2}, an electron pulse with an energy of around 350 keV and a relative momentum spread of about 10{sup -2} was compressed to a 500-fs pulse at a distance of about 50 cm from the electron source by using a magnetic pulse compressor. This pulse was used to generate a clear diffraction pattern of a gold crystal in a single shot. This method solves the space-charge problem in ultrafast electron diffraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Performance AlInGaAs/AlGaAs Photocathode

New photocathode for highly polarized electron emission has been developed, fabricated and studied. Polarized electron source is based on short-period strained AlInGaAs/AlGaAs superlattice grown by MBE method. Deformation of AlInGaAs quantum well results in 85 meV energy splitting between heavy hole and light hole minibands. Electron emission from the developed photocathode demonstrates maximal polarization of 92% with quantum efficiency of 0.85%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Electron Energy Spread in CsBr Based Photocathodes

Photocathodes with relatively low energy spread (<0.5 eV) are required for electron sources in several applications including single and multiple electron beam inspection and lithography tools and free electron lasers. CsBr based photocathodes have been shown to be very robust and capable of operation at high current density (>150 A/cm{sup 2}) with very long lifetime (approximately hundreds of hours/spot). Experimental results of the photoelectron energy spread obtained in CsBr films deposited on both metal and InGaN substrates will be presented in this paper.

36 MATERIALS SCIENCE↗

Femtosecond photoelectron point projection microscope

By utilizing a nanometer ultrafast electron source in a point projection microscope we demonstrate that images of nanoparticles with spatial resolutions of the order of 100 nanometers can be obtained. The duration of the emission process of the photoemitted electrons used to make images is shown to be of the order of 100 fs using an autocorrelation technique. The compact geometry of this photoelectron point projection microscope does not preclude its use as a simple ultrafast electron microscope, and we use simple analytic models to estimate temporal resolutions that can be expected when using it as a pump-probe ultrafast electron microscope. These models show a significant increase in temporal resolution when comparing to ultrafast electron microscopes based on conventional designs. We also model the microscopes spectroscopic abilities to capture ultrafast phenomena such as the photon induced near field effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic x-ray source using electrons produced by a 100 J-class picosecond laser

Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f/#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.

backlighter↗

Rotating dipole and quadrupole field for a multiple cathode system

A multiple cathode system has been designed to provide the high average current polarized electron bunches for the future electron-ion collider eRHIC [1]. One of the key research topics in this design is the technique to generate a combined dipole and quadrupole rotating field at high frequency (700 kHz). This type of field is necessary for combining bunches from different cathodes to the same axis with minimum emittance growth. Our simulations and the prototype test results to achieve this will be presented. The future eRHIC project, next upgrade of EHIC, will be the first electron-heavy ion collider in the world. For polarized-electron and polarized proton collisions, it requires a polarized electron source with high average current ({approx}50 mA), short bunch ({approx}3 mm), emittance of about 20 {micro}m and energy spread of {approx}1% at 10 MeV. The state-of-art polarized electron cathode can generate average current of about more than 1 mA, but much less than 50 mA. The current is limited by the quantum efficiency, lifetime, space charge and ultra-high vacuum requirement of the polarized cathode. A possible approach to achieve the 50 mA beam is to employ multiple cathodes, such as 20 cathodes, and combine the multiple bunched beams from cathodes to the same axis. We name it as 'Gatling gun' because its operations bear similarity to a multi-barrel Gatling gun. The electron spin direction is not affected by electric field but will follow to the direction of the magnetic bending. This requires that, to preserve the spin polarization from cathode, the fixed bending field after the solenoid and the rotating bending field in combiner must be either a pair of electric bendings or a pair of magnetic bendings. We choose the scheme with a pair of magnetic bendings because it is much easier than the scheme with a pair of electric bendings at our 200 keV electron energy level.

43 PARTICLE ACCELERATORS↗

Nonponderomotive electron acceleration in ultrashort surface-plasmon fields

We investigate the nonponderomotive nature of ultrafast plasmonic electron acceleration in strongly decaying electromagnetic fields generated by few-cycle and single-cycle femtosecond laser pulses. We clearly identify the conditions contributing to nonponderomotive acceleration and establish fundamental scaling laws and carrier-envelope phase effects. These all-optically accelerated compact, femtosecond electron sources can be utilized in contemporary ultrafast methods.

43 PARTICLE ACCELERATORS↗

Strong shock generation by fast electron energy deposition

It has been suggested that fast electrons may play a beneficial role in the formation of the ignitor shock in shock ignition owing to the high areal density of the fuel at the time of the ignitor pulse. In this paper, we extend previous studies which have focused on monoenergetic electron sources to populations with extended energy distributions. In good agreement with analytic scalings, we show that strong shocks can be produced with peak pressures of a few hundred Mbar to over 1 Gbar using fast electron intensities of 1–10 PW/cm{sup 2} in a uniform deuterium-tritium plasma at 10 g/cm{sup 3}. However, the length required for shock formation increases with fast electron temperature. As this shock formation distance becomes comparable to the target size, the shock is not able to fully develop, and this implies a limit on the ability of fast electrons to aid shock formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metasurface-based multi-harmonic free-electron light source

Metasurfaces are subwavelength spatial variations in geometry and material where the structures are of negligible thickness compared to the wavelength of light and are optimized for far-field applications, such as controlling the wavefronts of electromagnetic waves. Here, we investigate the potential of the metasurface near-field profile, generated by an incident few-cycle pulse laser, to facilitate the generation of high-frequency light from free electrons. In particular, the metasurface near-field contains higher-order spatial harmonics that can be leveraged to generate multiple higher-harmonic X-ray frequency peaks. We show that the X-ray spectral profile can be arbitrarily shaped by controlling the metasurface geometry, the electron energy, and the incidence angle of the laser input. Using ab initio simulations, we predict bright and monoenergetic X-rays, achieving energies of 30 keV (with harmonics spaced by 3 keV) from 5-MeV electrons using 3.4-eV plasmon polaritons on a metasurface with a period of 85 nm. As an example, we present the design of a four-color X-ray source, a potential candidate for tabletop multicolor hard X-ray spectroscopy. Our developments could help pave the way for compact multi-harmonic sources of high-energy photons, which have potential applications in industry, medicine, and the fundamental sciences.

36 MATERIALS SCIENCE↗

A vacuum sealed high emission current and transmission efficiency carbon nanotube triode

A vacuum sealed carbon nanotubes (CNTs) triode with a concave and spoke-shaped Mo grid is presented. Due to the high aperture ratio of the grid, the emission current could be modulated at a relatively high electric field. Totally 75 mA emission current has been obtained from the CNTs cathode with the average applied field by the grid shifting from 8 to 13 V/μm. Whilst with the electron transmission efficiency of the grid over 56%, a remarkable high modulated current electron beam over 42 mA has been collected by the anode. Also contributed by the high aperture ration of the grid, desorbed gas molecules could flow away from the emission area rapidly when the triode has been operated at a relative high emission current, and finally collected by a vacion pump. The working pressure has been maintained at ∼1 × 10{sup −7} Torr, seldom spark phenomena occurred. Nearly perfect I-V curve and corresponding Fowler-Nordheim (FN) plot confirmed the accuracy of the measured data, and the emission current was long term stable and reproducible. Thusly, this kind of triode would be used as a high-power electron source.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of compact electron cyclotron resonance ion source

The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C{sup 4+} ions; its performance such as beam intensity and stability has already reached the medical requirements. Therefore, the prototype development of the source for medical use is essentially finished. Recently, we have started a few studies on other applications of the source. One is the production of fullerenes in the ECR plasma and modified fullerenes with various atoms for new materials. A second application is the production of multiply charged ions (not only carbon) for ion implantation. In this paper, some basic experiments for these applications are reported.

36 MATERIALS SCIENCE↗

Achieving Long Confinement in a Toroidal Electron Plasma

We observe the m = 1 diocotron mode in a partial toroidal trap, and use it as the primary diagnostic for observing the plasma confinement. The frequency of the m = 1 mode, which is approximately proportional to the trapped charge, decays on a three second timescale. The confinement time exceeds, by at least an order of magnitude, the confinement observed in all other toroidal traps for non-neutral plasmas and approaches the theoretical limit set by magnetic pumping transport. Numerical simulations that include toroidal effects are employed to accurately extract plasma charge, equilibrium position and m = 1 mode amplitude from the experimental data. Future work will include attempts to withdraw the electron source in order to study confinement in a full torus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linac Coherent Light Source II (LCLS-II) Conceptual Design Report

The LCLS-II Project is designed to support the DOE Office of Science mission, as described in the 22 April 2010 Mission Need Statement. The scope of the Project was chosen to provide an increase in capabilities and capacity for the facility both at project completion in 2017 and in the subsequent decade. The Project is designed to address all points of the Mission Need Statement (MNS): (1) Expanded spectral reach; (2) Capability to provide x-ray beams with controllable polarization; (3) Capability to provide 'pump' pulses over a vastly extended range of photon energies to a sample, synchronized to LCLS-II x-ray probe pulses with controllable inter-pulse time delay; and (4) Increase of user access through parallel rather than serial x-ray beam use within the constraint of a $300M-$400M Total Project Cost (TPC) range. The LCLS-II Project will construct: (1) A hard x-ray undulator source (2-13 keV); (2) A soft x-ray undulator source (250-2,000 eV); (3) A dedicated, independent electron source for these new undulators, using sectors 10-20 of the SLAC linac; (4) Modifications to existing SLAC facilities for the injector and new shielded enclosures for the undulator sources, beam dumps and x-ray front ends; (5) A new experiment hall capable of accommodating four experiment stations; and (6) Relocation of the two soft x-ray instruments in the existing Near Experiment Hall (NEH) to the new experiment hall (Experiment Hall-II). A key objective of LCLS-II is to maintain near-term international leadership in the study of matter on the fundamental atomic length scale and the associated ultrafast time scales of atomic motion and electronic transformation. Clearly, such studies promise scientific breakthroughs in key areas of societal needs like energy, environment, health and technology, and they are uniquely enabled by forefront X-ray Free Electron Laser (X-FEL) facilities. While the implementation of LCLS-II extends to about 2017, it is important to realize that LCLS-II only constitutes a stepping stone to what we believe is needed over a longer time scale. At present, a practical time horizon for planning is about 15 years into the future, matching that of worldwide planning activities for competitive X-FEL facilities in Europe and Asia. We therefore envision LCLS-II as an important stage in development to what is required by about 2025, tentatively called LCLS-2025, for continued US leadership even as new facilities around the world are being completed. We envision LCLS primarily as a hard x-ray FEL facility with some soft x-ray capabilities. A survey of planned X-FEL facilities around the world suggests that US planning to 2025 needs to include an internationally competitive soft x-ray FEL facility which complements the LCLS plans outlined in this document.

43 PARTICLE ACCELERATORS↗

Large and stable emission current from synthesized carbon nanotube/fiber network

In order to obtain a large and stable electron field emission current, the carbon nanotubes have been synthesized on carbon fibers by cold wall chemical vapor deposition method. In the hierarchical nanostructures, carbon fibers are entangled together to form a conductive network, it could provide excellent electron transmission and adhesion property between electrode and emitters, dispersed clusters of carbon nanotubes with smaller diameters have been synthesized on the top of carbon fibers as field emitters, this kind of emitter distribution could alleviate electrostatic shielding effect and protect emitters from being wholly destroyed. Field emission properties of this kind of carbon nanotube/fiber network have been tested, up to 30 mA emission current at an applied electric field of 6.4 V/μm was emitted from as-prepared hierarchical nanostructures. Small current degradation at large emission current output by DC power operation indicated that carbon nanotube/fiber network could be a promising candidate for field emission electron source.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Towards ultrafast dynamics with split-pulse X-ray photon correlation spectroscopy at free electron laser sources

One of the important challenges in condensed matter science is to understand ultrafast, atomic-scale fluctuations that dictate dynamic processes in equilibrium and non-equilibrium materials. Here, we report an important step towards reaching that goal by using a state-of-the-art perfect crystal based split-and-delay system, capable of splitting individual X-ray pulses and introducing femtosecond to nanosecond time delays. We show the results of an ultrafast hard X-ray photon correlation spectroscopy experiment at LCLS where split X-ray pulses were used to measure the dynamics of gold nanoparticles suspended in hexane. We show how reliable speckle contrast values can be extracted even from very low intensity free electron laser (FEL) speckle patterns by applying maximum likelihood fitting, thus demonstrating the potential of a split-and-delay approach for dynamics measurements at FEL sources. This will enable the characterization of equilibrium and, importantly also reversible non-equilibrium processes in atomically disordered materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 140 mA cw deuteron electron cyclotron resonance source for the IFMIF-EVEDA project

In the framework of the IFMIF-EVEDA phase (International Fusion Materials Irradiation Facility--Engineering Validation and Engineering Design Activities), the CEA-Saclay is in charged of the design and realization of the 140 mA cw deuteron source. The IFMIF EVEDA demonstrator will be installed in Japan in the next six years and will have to accelerate the deuteron beam up to 9 MeV. CEA will build the source and the low energy beam line (LEBT) and will test the cw high intensity deuteron production at Saclay. The SILHI source is an electron cyclotron resonance (ECR) source, operating at 2.45 GHz. In 2001, it produced more than 130 mA of deuteron beam in pulsed mode to minimize neutron production. Such a result pushes to develop a new ECR source based on the SILHI design and equipped with a specific extraction system. Several options of the accelerator column will be implemented in order to improve the reliability and the efficiency of the source. The IFMIF source and LEBT design will be reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a simple annular electron beam source and its operating characteristics in single and repetitive shot modes

In this work, design and performance of an annular carbon fiber cathode are presented. Measurements on this cathode were performed in a single high-voltage pulse generator (600 kV, 50 ns, and 50 {omega}) and a repetitive one (350 kV, <10 ns, 180 {omega}, and 100 Hz), respectively. In a single pulse regime, emphasis was placed on the uniformity of electron beam extracted from this cathode. It was found that this cathode could deliver uniform electron beams with current densities exceeding kA/cm{sup 2}. Cesium iodide (CsI) coating eliminated hot spots on the cathode surface, significantly improving the uniformity of electron emission. Under repetitively pulsed operation, this cathode exhibited a good shot-to-shot reproducibility at the pressure of 1.5x10{sup -4} Torr, suggesting an ability of surviving even in poor vacuum. However, once the base pressure rose up to 3.76x10{sup -4} Torr, the cathode performance gradually degraded as the pulse shot proceeded. Besides, some possible explanations for these experimental results are presented. These results show that given proper diode design, carbon fiber with CsI coating has great promise as electron emitter producing high-current electron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗