Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronically conducting polymers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Processing, structure, and thermal properties of ZrW 2 O 8 , HfW 2 O 8 , HfMgW 3 O 12 , Al(HfMg) 0.5 W 3 O 12 , and Al 0.5 Sc 1.5 W 3 O 12 negative and zero thermal expansion coefficient ceramics

Negative and zero coefficient of thermal expansion (CTE) materials are of interest for developing polymer composites in electronic circuits that match the expansion of Si and in zero CTE supports for optical components, e.g., mirrors. In this work, the processing challenges and stability of ZrW 2 O 8 , HfW 2 O 8 , HfMgW 3 O 12 , Al(HfMg) 0.5 W 3 O 12 , and Al 0.5 Sc 1.5 W 3 O 12 negative and zero thermal expansion coefficient ceramics are discussed. Al 0.5 Sc 1.5 W 3 O 12 is demonstrated to be a relatively simple oxide to fabricate in large quantity and is shown to exhibit single phase up to 1300 °C in air and inert N 2 environments. The negative and zero CTE behavior was confirmed with dilatometry. Thermal conductivity and heat capacity were reported for the first time for HfMgW 3 O 12 and Al 0.5 Sc 1.5 W 3 O 12 and thermal conductivity was found to be very low (~0.5 W/mK). Grüneisen parameter is also estimated. Methods for integration of Al 0.5 Sc 1.5 W 3 O 12 with other materials was examined and embedding 50 vol% of the ceramic powder in flexible epoxy was demonstrated with a commercial vendor.

36 MATERIALS SCIENCE↗

Compatibility of ethylene vinyl acetate (EVA)/ethylene vinyl alcohol (EVOH)/EVA films with gamma, electron-beam, and X-ray irradiation

Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative Electrostatic Adhesion Technologies

Developing specialized Electro-Static grippers (commercially used in Semiconductor Manufacturing and in package handling) will allow gentle and secure Capture, Soft Docking, and Handling of a wide variety of materials and shapes (such as upper-stages, satellites, arrays, and possibly asteroids) without requiring physical features or cavities for a pincher or probe or using harpoons or nets. Combined with new rigid boom mechanisms or small agile chaser vehicles, flexible, high speed Electro-Static Grippers can enable compliant capture of spinning objects starting from a safe stand-off distance. Electroadhesion (EA) can enable lightweight, ultra-low-power, compliant attachment in space by using an electrostatic force to adhere similar and dissimilar surfaces. A typical EA enabled device is composed of compliant space-rated materials, such as copper-clad polyimide encapsulated by polymers. Attachment is induced by strong electrostatic forces between any substrate material, such as an exterior satellite panel and a compliant EA gripper pad surface. When alternate positive and negative charges are induced in adjacent planar electrodes in an EA surface, the electric fields set up opposite charges on the substrate and cause an electrostatic adhesion between the electrodes and the induced charges on the substrate. Since the electrodes and the polymer are compliant and can conform to uneven or rough surfaces, the electrodes can remain intimately close to the entire surface, enabling high clamping pressures. Clamping pressures of more than 3 N/cm2 in shear can be achieved on a variety of substrates with ultra-low holding power consumption (measured values are less than 20 microW/Newton weight held). A single EA surface geometry can be used to clamp both dielectric and conductive substrates, with slightly different physical mechanisms. Furthermore EA clamping requires no normal force be placed on the substrate, as conventional docking requires. Internally funded research and development has demonstrated that EA can function effectively in space, even in the presence of strong ultraviolet radiation, atomic oxygen, and free electrons. We created a test setup in an existing vacuum chamber to simulate low-Earth-orbit conditions. An EA mechanism was fabricated and installed in the chamber, instrumented, operated in a vacuum, and subjected to ultraviolet photons and free electrons generated by an in-chamber multipactor electron emitter. Extensions to EA that can add value include proximity and contact sensing and transverse motion or rotation, both of which could enhance docking or assembly applications. Possible next steps include development of targeted applications for ground investigation or on-orbit subsystem performance demonstrations using low cost access to space such as CubeSats.

Bryan, Tom↗

Computational Insights into the Salt-Induced Modulation of Electron Transporting Conjugated Polyelectrolytes

The morphological and electronic properties of conjugated polyelectrolytes (CPEs) are highly sensitive to their ionic environment and remain poorly understood. To elucidate structure–property relationships in CPEs, we investigate the role of salt concentration on CPE morphology and hole conductivity using a quantum mechanically informed coarse-grained (CG) model coupled with semiclassical rate theory. Under good solvent conditions, high salt concentration induces torsional disorder along the conjugated backbone, decreasing hole delocalization. In contrast, under poor solvent conditions, high salt concentration promotes CPE aggregation, leading to thicker fibers and increased hole mobilities. Collectively, this work characterizes the competing interactions governing CPE assembly and hole transport as a function of salt concentration, highlighting ion engineering as a powerful strategy for tailoring the properties of mixed-conducting polymers.

diseases↗

PILBCP-IL Composite Ionomers for High Current Density Performance

Wide-spread commercialization of fuel cell electric vehicles using proton exchange membrane fuel cell (PEMFC) power sources requires that several existing limitations be addressed. These include: (1) a reduction in platinum (Pt) loading in the catalytic electrodes, (2) improvements in reactant and electronic mobility throughout the catalytic electrodes, (3) reduction in the reliance on materials derived from polluting “forever chemicals”, and (4) a significant improvement in the operational longevity of catalytic electrode components. In this project, a team of two universities, Drexel University and Texas A&M University, one national lab, National Renewable Energy Laboratory, and one company, General Motors, collaborated to develop a new cathode ionomer chemistry that would address these limitations and result in an improvement in performance over existing ionomer materials. The key technology developed through this collaborative project was a composite cathode ionomer encompassing an ionic liquid interlayer between Pt catalysts and a sulfonated polymerized ionic liquid block co-polymer (S-PILBCP) that possess the orthogonal properties of protonic conductivity and ionic liquid enhanced kinetics and durability (see schematic in Figure 1). The composite S-PILBCP ionomer eliminates many of the existing issues with perfluorosulfonic acid-based ionomers including active site blocking by sulfonate specific adsorption, restricted O 2 transport through ionomer films, limited humidity tolerance and active area loss for carbon pore confined catalyst particles, and use of polluting “forever chemicals”. Following successful integration of the developed composite ionic liquid into a PEMFC cathode catalyst layer, we demonstrate enhanced performance over Nafion containing cathodes with Pt/C and PtCo/C at both low and high current density. The performance with our composite S-PILBCP ionomer meets the Department of Energy (DOE) targets for light duty vehicle applications

08 HYDROGEN↗

Mechanical properties of neat polymer matrix materials and their unidirectional carbon fiber-reinforced composites

The mechanical properties of two neat resin systems for use in carbon fiber epoxy composites were characterized. This included tensile and shear stiffness and strengths, coefficients of thermal and moisture expansion, and fracture toughness. Tests were conducted on specimens in the dry and moisture-saturated states, at temperatures of 23, 82 and 121 C. The neat resins tested were American Cyanamid 1806 and Union Carbide ERX-4901B(MPDA). Results were compared to previously tested neat resins. Four unidirectional carbon fiber reinforced composites were mechanically characterized. Axial and transverse tension and in-plane shear strengths and stiffness were measured, as well as transverse coefficients of thermal and moisture expansion. Tests were conducted on dry specimens only at 23 and 100 C. The materials tested were AS4/3502, AS6/5245-C, T300/BP907, and C6000/1806 unidirectional composites. Scanning electron microscopic examination of fracture surfaces was performed to permit the correlation of observed failure modes with the environmental test conditions.

Zimmerman, Richard S.↗

Mutually Reinforced Polymer–Graphene Bilayer Membranes for Energy‐Efficient Acoustic Transduction

Abstract Graphene holds promise for thin, ultralightweight, and high‐performance nanoelectromechanical transducers. However, graphene‐only devices are limited in size due to fatigue and fracture of suspended graphene membranes. Here, a lightweight, flexible, transparent, and conductive bilayer composite of polyetherimide and single‐layer graphene is prepared and suspended on the centimeter scale with an unprecedentedly high aspect ratio of 10 5 . The coupling of the two components leads to mutual reinforcement and creates an ultrastrong membrane that supports 30 000 times its own weight. Upon electromechanical actuation, the membrane pushes a massive amount of air and generates high‐quality acoustic sound. The energy efficiency is ≈ 10–100 times better than state‐of‐the‐art electrodynamic speakers. The bilayer membrane's combined properties of electrical conductivity, mechanical strength, optical transparency, thermal stability, and chemical resistance will promote applications in electronics, mechanics, and optics.

Khan, Assad U.↗

Biopolymer-supramolecular polymer hybrids for photocatalytic hydrogen production

Solar generation of H 2 is a promising strategy for dense energy storage. Supramolecular polymers composed of chromophore amphiphile monomers containing perylene monoimide (PMI) have been reported as crystalline light-harvesting assemblies for aqueous H 2 -evolving catalysts. Gelation of these supramolecular polymers with multivalent ions creates hydrogels with high diffusivity but insufficient mechanical stability and catalyst retention for reusability. We report here on using sodium alginate (SA) biopolymer to both induce supramolecular polymerization of PMI and co-immobilize them with catalysts in a robust hydrogel with high diffusivity that can also be 3D-printed. Faster mass transfer was achieved by controlling the material macrostructure by reducing gel diameter and microstructure by reducing biopolymer loading. Optimized gels produce H 2 at rates rivaling solution-based PMI and generate H 2 for up to 6 days. The PMI assemblies in the SA matrix create a percolation network capable of bulk-electron transfer under illumination. These PMI–SA materials were then 3D-printed on conductive substrates to create 3D hydrogel photoelectrodes with optimized porosity. The design of these versatile hybrid materials was bioinspired by the soft matter environment of natural photosynthetic systems and opens the opportunity to carry out light-to-fuel conversion within soft matter with arbitrary shapes and particular local environments.

36 MATERIALS SCIENCE↗

Morphology of poly-3-hexyl-thiophene blends with styrene–isoprene–styrene block-copolymer elastomers from X-ray and neutron scattering

The nano- and micron scale morphology of poly(3-hexylthiophene) (P3HT) and polystyrene-block-polyisoprene-block-polystyrene (PS–PI–PS) elastomeric blends is investigated through the use of ultra-small and small angle X-ray and neutron scattering (USAXS, SAXS, SANS). It is demonstrated that loading P3HT into elastomer matrices is possible with little distortion of the elastomeric structure up to a loading of ~5 wt%. Increased loadings of conjugated polymer is found to significantly distort the matrix structure. Changes in processing conditions are also found to affect the blend morphology with especially strong dependence on processing temperature. Processing temperatures above the glass transition temperature (T g ) of polystyrene and the melting temperature (T m ) of the conjugated polymer additive (P3HT) creates significantly more organized mesophase domains. P3HT blends with PS–PI–PS can also be flow-aligned through processing, which results in an anisotropic structure that could be useful for the generation of anisotropic properties (e.g. conductivity). Moreover, the extent of flow alignment is significantly affected by the P3HT loading in the PS–PI–PS matrix. The work adds insight to the morphological understanding of a complex P3HT and PS–PI–PS polymer blend as conjugated polymer is added to the system. Here, we also provide studies isolating the effect of processing changes aiding in the understanding of the structural changes in this elastomeric conjugated polymer blend.

36 MATERIALS SCIENCE↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Two-Phase Thermal Switching System for a Small, Extended Duration Lunar Surface Science Platform

This paper describes a novel thermal control system for the Warm Electronics Box (WEB) on board a small lunar surface lander intended to support science activities anywhere on the lunar surface for an extended duration of up to 6 years. Virtually all lander electronics, which collectively dissipate about 60 W in the reference mission, are contained within the WEB. These devices must be maintained below 323 K (with a goal of 303 K) during the nearly 15-earth-day lunar day, when surface temperatures can reach 390K, and above 263 K during the nearly 15-earth-day lunar night, when surface temperatures can reach 100K. Because of the large temperature swing from lunar day-to-night, a novel thermal switching system was required that would be able to provide high conductance from WEB to radiator(s) during the hot lunar day and low (or negligible) conductance during the cold lunar night. The concept that was developed consists of ammonia variable conductance heat pipes (VCHPs) to collect heat from WEB components and a polymer wick propylene loop heat pipe (LHP) to transport the collected heat to the radiator(s). The VCHPs autonomously maximize transport when the WEB is warm and autonomously shut down when the WEB gets cold. The LHP autonomously shuts down when the VCHPs shut down. When the environment transitions from lunar night to day, the VCHPs and LHP autonomously turn back on. Out of 26 analyzed systems, this novel arrangement was able to best achieve the combined goals of zero control power, autonomous operation, long life, low complexity, low T, and landed tilt tolerance.

Bugby, David C.↗

Polymer thick-film conductors and dielectrics for membrane switches and flexible circuitry

The fabrication and operation of membrane switches are discussed. The membrane switch functions as a normally open, momentary contact, low-voltage pressure-sensitive device. Its design is a three-layer sandwich usually constructed of polyester film. Conductive patterns are deposited onto the inner side of top and bottom sheets by silk screening. The center spacer is then placed between the two circuit layers to form a sandwich, generally held together by an adhesive. When pressure is applied to the top layer, it flexes through the punched openings of the spacer to establish electrical contact between conductive pads of the upper and lower sheets, momentarily closing the circuit. Upon release of force the top sheet springs back to its normal open position. The membrane touch switch is being used in a rapidly expanding range of applications, including instrumentation, appliances, electronic games and keyboards. Its board acceptance results from its low cost, durability, ease of manufacture, cosmetic appeal and design flexibility. The principal electronic components in the membrane switch are the conductor and dielectric.

Nazarenko, N.↗

Toward Long-Life, Ultrahigh-Nickel Layered Oxide Cathodes for Lithium-Ion Batteries: Optimizing the Interphase Chemistry with a Dual-Functional Polymer

Boosting the Ni content in LiMO 2 (M = Ni, Co, Mn, etc.) layered oxides is a promising way to establish high-energydensity, low-cost cathodes, but the poor cathode surface stability is a daunting challenge for their practical viability. Herein, by constructing a dual-functional binder framework with a conductive polymer - polyaniline (PANI), the ultrahigh-Ni layered oxide cathode (LiNi 0.94 Co 0.06 O 2 ) exhibits significantly improved cyclability, with a capacity retention greatly increased from 47% to 81% over 1,000 cycles in full cells. It is demonstrated that the acidic species (e.g. HF) in the electrolyte can be efficiently scavenged through a protonation process of PANI, hence the cathode surface reactivity is greatly suppressed and the rock-salt phase propagation into bulk structure is considerably alleviated. Furthermore, the PANI binder system effectively prevents both the cathode-electrolyte interphase (CEI) and anode-electrolyte interphase (AEI) from degrading to a thick “triple-layer” architecture upon extensive cycling, resulting in more robust, thinner CEI and AEI with regulated interphasial chemistry. Moreover, the delocalized π-conjugated electrons along the backbone of PANI facilitate fast electron transfer and promote rate capability even at low temperatures (-20 °C). Finally, this work sheds light on rational binder engineering for developing high-energy-density lithium-ion batteries with acceptable cycle life.

25 ENERGY STORAGE↗

HEPOM: Using Graph Neural Networks for the Accelerated Predictions of Hydrolysis Free Energies in Different pH Conditions

Hydrolysis is a fundamental family of chemical reactions where water facilitates the cleavage of bonds. The process is ubiquitous in biological and chemical systems, owing to water’s remarkable versatility as a solvent. However, accurately predicting the feasibility of hydrolysis through computational techniques is a difficult task, as subtle changes in reactant structure like heteroatom substitutions or neighboring functional groups can influence the reaction outcome. Furthermore, hydrolysis is sensitive to the pH of the aqueous medium, and the same reaction can have different reaction properties at different pH conditions. In this work, we have combined reaction templates and high-throughput ab initio calculations to construct a diverse data set of hydrolysis free energies. The developed framework automatically identifies reaction centers, generates hydrolysis products, and utilizes a trained graph neural network (GNN) model to predict ΔG values for all potential hydrolysis reactions in a given molecule. The long-term goal of the work is to develop a data-driven, computational tool for high-throughput screening of pH-specific hydrolytic stability and the rapid prediction of reaction products, which can then be applied in a wide array of applications including chemical recycling of polymers and ion-conducting membranes for clean energy generation and storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic functionalization and catalytic behavior of magnetic nanoparticles during laser photochemical graphitization of polyimide

We report laser-assisted photochemical graphitization of polyimides (PIs) into functional magnetic nanocomposites using laser irradiation of PI in the presence of magnetite nanoparticles (MNPs). PI Kapton sheets covered with MNP were photochemically treated under ambient conditions using a picosecond pulsed laser (1064 nm) to obtain an electrically conductive material. Scanning electron microscopy of the treated material revealed a layered magnetic nanoparticle/graphite (MNP/graphite) nanocomposite structure. Four probe conductivity measurements indicated that the nanocomposite has an electrical conductivity of 1550 ± 60 S/m. Superconducting quantum interference device magnetometer-based magnetic characterization of the treated material revealed an anisotropic ferromagnetic response in the MNP/graphite nanocomposite compared to the isotropic response of MNP. Raman spectroscopy of the MNP/graphite nanocomposite revealed a fourfold improvement in graphitization, suppression in disorder, and decreased nitrogenous impurities compared to the graphitic material obtained from laser treatment of just PI sheets. X-ray photoelectron spectroscopy, x-ray diffraction, and energy-dispersive x-ray spectroscopy were used to delineate the phase transformations of MNP during the formation of MNP/graphite nanocomposite. Post-mortem characterization indicates a possible photocatalytic effect of MNP during MNP/graphite nanocomposite formation. Under laser irradiation, MNP transformed from the initial Fe 3 O 4 phase to γ-Fe 2 O 3 and Fe 5 C 2 phases and acted as nucleation spots to catalyze the graphitization process of PI.

36 MATERIALS SCIENCE↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗

Thermal Conductivity of Polymer Copoly(Ethylene Vinyl Acetate)/Nano-Filler Blends

The development of flexible, thermally conductive fabrics and plastic tubes for the Liquid Cooling and Ventilation Garment (LCVG) are needed to reduce weight and improve the mobility, comfort, and performance of future spacesuits. Such improvements would allow astronauts to operate more efficiently and safely for extended extravehicular activities. As a continuation of our work on the improvement of thermal conductivity (TC) of polymeric materials, nanocomposites were prepared from copoly(ethylene vinyl acetate), trade name Elvax 260 , metallized carbon nanofibers (CNFs), nickel (Ni) nanostrands, boron nitride both alone and as mixtures with aluminum powder. The nanocomposites were prepared by melt mixing at various loading levels and subsequently fabricated into several material forms (i.e., ribbons, tubes, and compression molded plaques) for analysis. Ribbons and tubes were extruded to form samples in which the nanoparticles were aligned in the direction of flow. The degree of dispersion and alignment of the nanoparticles were investigated using high-resolution scanning electron microscopy. Tensile properties of the aligned samples were determined at room temperature. TC measurements were performed using a laser flash (Nanoflash ) technique. The TC of the samples was measured in both the direction of alignment as well as transverse. Tubing of comparable dimensions to that used in the LCVG was extruded from select compositions and the thermal conductivities of the tubes measured.

Ghose, S.↗

Deep Dielectric Charging of Spacecraft Polymers by Energetic Protons

The majority of research in the field of spacecraft charging concentrates on electron charging effects with little discussion of charging by protons. For spacecraft orbiting in the traditional LEO and GEO environments this emphasis on electrons is appropriate since energetic electrons are the dominant species in those orbits. But for spacecraft in orbits within the inner radiation belts or for interplanetary and lunar space probes, proton charging (center dot) effects may also be of concern. To examine bulk spacecraft charging effects in these environments several typical highly insulating spacecraft polymers were exposed to energetic protons (center dot) with energies from 1 Me V to lO Me V to simulate protons from the solar wind and from solar energetic proton events. Results indicate that effects in proton charged dielectrics are distinctly different than those observed due to electron charging. In most cases, the positive surface potential continued to increase for periods on the order of minutes to a day, followed by long time scale decay at rates similar to those observed for electron charging. All samples charged to positive potentials with substantially lower magnitudes than for equivalent electron doses. Possible explanations for the different behavior of the measured surface potentials from proton irradiation are discussed; these are related to the evolving internal charge distribution from energy dependent electron and proton transport, electron emission, charge migration due to dark current and radiation induced conductivity, and electron capture by embedded protons.

radiation induced conductivity↗