Search NASA⌕ Search

SEARCH · Search NASA

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Divergence Free High Order Filter Methods for the Compressible MHD Equations

The generalization of a class of low-dissipative high order filter finite difference methods for long time wave propagation of shock/turbulence/combustion compressible viscous gas dynamic flows to compressible MHD equations for structured curvilinear grids has been achieved. The new scheme is shown to provide a natural and efficient way for the minimization of the divergence of the magnetic field numerical error. Standard diver- gence cleaning is not required by the present filter approach. For certain MHD test cases, divergence free preservation of the magnetic fields has been achieved.

Yea, H. C.↗

Design of 3x3 Focusing Array for Heavy Ion Driver Final Report on CRADA TC-02082-04

This memo presents a design of a 3x3 quadrupole array for HIF. It contains 3 D magnetic field computations of the array build with racetrack coils with and without different shields. It is shown that it is possible to have a low error magnetic field in the cells and shield the stray fields to acceptable levels. The array design seems to be a practical solution to any size array for future multi-beam heavy ion fusion drivers.

42 ENGINEERING↗

High Order Filter Methods for the Non-ideal Compressible MHD Equations

The generalization of a class of low-dissipative high order filter finite difference methods for long time wave propagation of shock/turbulence/combustion compressible viscous gas dynamic flows to compressible MHD equations for structured curvilinear grids has been achieved. The new scheme is shown to provide a natural and efficient way for the minimization of the divergence of the magnetic field numerical error. Standard divergence cleaning is not required by the present filter approach. For certain non-ideal MHD test cases, divergence free preservation of the magnetic fields has been achieved.

Yee, H. C.↗

SU-F-T-310: Does a Head-Mounted Ionization Chamber Detect IMRT Errors?

Purpose: The conventional plan verification strategy is delivering a plan to a QA-phantom before the first treatment. Monitoring each fraction of the patient treatment in real-time would improve patient safety. We evaluated how well a new detector, the IQM (iRT Systems, Germany), is capable of detecting errors we induced into IMRT plans of three different treatment regions. Results were compared to an established phantom. Methods: Clinical plans of a brain, prostate and head-and-neck patient were modified in the Pinnacle planning system, such that they resulted in either several percent lower prescribed doses to the target volume or several percent higher doses to relevant organs at risk. Unaltered plans were measured on three days, modified plans once, each with the IQM at an Elekta Synergy with an Agility MLC. All plans were also measured with the ArcCHECK with the cavity plug and a PTW semiflex 31010 ionization chamber inserted. Measurements were evaluated with SNC patient software. Results: Repeated IQM measurements of the original plans were reproducible, such that a 1% deviation from the mean as warning and 3% as action level as suggested by the manufacturer seemed reasonable. The IQM detected most of the simulated errors including wrong energy, a faulty leaf, wrong trial exported and a 2 mm shift of one leaf bank. Detection limits were reached for two plans - a 2 mm field position error and a leaf bank offset combined with an MU change. ArcCHECK evaluation according to our current standards also left undetected errors. Ionization chamber evaluation alone would leave most errors undetected. Conclusion: The IQM detected most errors and performed as well as currently established phantoms with the advantage that it can be used throughout the whole treatment. Drawback is that it does not indicate the source of the error.

60 APPLIED LIFE SCIENCES↗

On the reach of perturbative methods for dark matter density fields

We study the mapping from Lagrangian to Eulerian space in the context of the Effective Field Theory (EFT) of Large Scale Structure. We compute Lagrangian displacements with Lagrangian Perturbation Theory (LPT) and perform the full non-perturbative transformation from displacement to density. When expanded up to a given order, this transformation reproduces the standard Eulerian Perturbation Theory (SPT) at the same order. However, the full transformation from displacement to density also includes higher order terms. These terms explicitly resum long wavelength motions, thus making the resulting density field better correlated with the true non-linear density field. As a result, the regime of validity of this approach is expected to extend that of the Eulerian EFT, and match that of the IR-resummed Eulerian EFT. This approach thus effectively enables a test of the IR-resummed EFT at the field level. We estimate the size of stochastic, non-perturbative contributions to the matter density power spectrum. We find that in our highest order calculation, at redshift z = 0 the power spectrum of the density field is reproduced with an accuracy of 1% (10%) up to k = 0.25 hMpc{sup −1} (k = 0.46 hMpc{sup −1}). We believe that the dominant source of the remaining error is the stochastic contribution. Unfortunately, on these scales the stochastic term does not yet scale as k{sup 4} as it does in the very low k regime. Thus, modeling this contribution might be challenging.

79 ASTRONOMY AND ASTROPHYSICS↗

Instantaneous Io flux tube as the source of Jovian DAM - Possible second harmonic emissions

To determine if the source of the Jovian Io-dependent DAM (decametric) emission is along the instantaneous Io flux tube (IIFT), the results of ray-tracing calculations are compared with radio emission data obtained by the Planetary Radio Astronomy instruments on Voyager 1 and 2. RX mode gyroemission at frequencies near the local gyrofrequency and sources along field lines within the active sector between 150 and 270 deg longitude are assumed. The results indicate good agreement with the observations if the source is within 20 deg of the IIFT, but the maximum gyrofrequency of the model magnetic field is smaller than the observed maximum frequency of the DAM for the assumed active field line. While errors in the magnetic-field model coupled with emission at large Doppler shift might explain this discrepancy, a more natural explanation is that the higher-frequency component of the DAM is due to second-harmonic gyroemission.

Menietti, J. D.↗

Test of the principle of operation of a wideband magnetic direction finder for lightning return strokes

The principle of operation of a wideband crossed-loop magnetic-field direction finder is studied by comparing the bearing determined from the NS and EW magnetic fields at various times up to 155 microsec after return stroke initiation with the TV-determined lightning channel base direction. For 40 lightning strokes in the 3 to 12 km range, the difference between the bearings found from magnetic fields sampled at times between 1 and 10 microsec and the TV channel-base data has a standard deviation of 3-4 deg. Included in this standard deviation is a 2-3 deg measurement error. For fields sampled at progressively later times, both the mean and the standard deviation of the difference between the direction-finder bearing and the TV bearing increase. Near 150 microsec, means are about 35 deg and standard deviations about 60 deg. The physical reasons for the late-time inaccuracies in the wideband direction finder and the occurrence of these effects in narrow-band VLF direction finders are considered.

Herrman, B. D.↗

Nucleon Axial Charge in (2+1)-Flavor Dynamical-Lattice QCD with Domain-Wall Fermions

We present results for the nucleon axial charge g{sub A} at a fixed lattice spacing of 1/a=1.73(3) GeV using 2+1 flavors of domain wall fermions on size 16{sup 3}x32 and 24{sup 3}x64 lattices (L=1.8 and 2.7 fm) with length 16 in the fifth dimension. The length of the Monte Carlo trajectory at the lightest m{sub {pi}} is 7360 units, including 900 for thermalization. We find finite volume effects are larger than the pion mass dependence at m{sub {pi}}=330 MeV. We also find a scaling with the single variable m{sub {pi}}L which can also be seen in previous two-flavor domain wall and Wilson fermion calculations. Using this scaling to eliminate the finite-volume effect, we obtain g{sub A}=1.20(6)(4) at the physical pion mass, m{sub {pi}}=135 MeV, where the first and second errors are statistical and systematic. The observed finite-volume scaling also appears in similar quenched simulations, but disappear when V{>=}(2.4 fm){sup 3}. We argue this is a dynamical quark effect.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wavelet Approximation in Data Assimilation

Estimation of the state of the atmosphere with the Kalman filter remains a distant goal because of high computational cost of evolving the error covariance for both linear and nonlinear systems. Wavelet approximation is presented here as a possible solution that efficiently compresses both global and local covariance information. We demonstrate the compression characteristics on the the error correlation field from a global two-dimensional chemical constituent assimilation, and implement an adaptive wavelet approximation scheme on the assimilation of the one-dimensional Burger's equation. In the former problem, we show that 99%, of the error correlation can be represented by just 3% of the wavelet coefficients, with good representation of localized features. In the Burger's equation assimilation, the discrete linearized equations (tangent linear model) and analysis covariance are projected onto a wavelet basis and truncated to just 6%, of the coefficients. A nearly optimal forecast is achieved and we show that errors due to truncation of the dynamics are no greater than the errors due to covariance truncation.

Tangborn, Andrew↗

GRACE: millimeters and microns in orbit

The Gravity Recovery and Climate Experiment launched March 17, 2002. The GPS data for this experiment are processed to contribute to the recover long wavelength gravity field; remove errors due to long term on-board oscillator drift; and align K/Ka-band measurments between the two spacecraft to 0.1 ns. This paper will concentrate on the use of GPS for these timing and calibration functions and will not address the recovery of the gravity field.

GRACE GPS K/Ka-band↗

Estimate of the critical exponents from the field-theoretical renormalization group: mathematical meaning of the 'Standard Values'

New estimates of the critical exponents have been obtained from the field-theoretical renormalization group using a new method for summing divergent series. The results almost coincide with the central values obtained by Le Guillou and Zinn-Justin (the so-called standard values), but have lower uncertainty. It has been shown that usual field-theoretical estimates implicitly imply the smoothness of the coefficient functions. The last assumption is open for discussion in view of the existence of the oscillating contribution to the coefficient functions. The appropriate interpretation of the last contribution is necessary both for the estimation of the systematic errors of the standard values and for a further increase in accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A precise new KLOE measurement of |F{sub {pi}}|{sup 2} with ISR events and determination of {pi}{pi} contribution to a{sub {mu}} for 0.592<M{sub {pi}}{sub {pi}}<0.975 GeV

The KLOE experiment at the DA{phi}NE {phi}-factory has performed a new precise measurement of the pion form factor using Initial State Radiation events, with photons emitted at small polar angle. Results based on an integrated luminosity of 240 pb{sup -1} and extraction of the {pi}{pi} contribution to a{sub {mu}} in the mass range 0.35<M{sub {pi}}{sub {pi}}{sup 2}<0.95 GeV{sup 2} are presented. The new value of a{sub {mu}}{sup {pi}}{sup {pi}} has smaller (30%) statistical and systematic error and is consistent with the KLOE published value (confirming the current disagreement between the standard model prediction for a{sub {mu}} and the measured value)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A preliminary error analysis of the gravity field recovery from a lunar Satellite-to-Satellite mission

A low cost lunar Satellite-to-Satellite radio tracking mission in a low-low configuration could considerably improve the existing knowledge about the lunar gravity field. The impact of various mission parameters that may contribute to the recovery of the gravity field, such as satellite altitude, satellite separation mission duration, measurement precision and sampling interval were quantified using the Jekeli-Rapp algorithm. Preliminary results indicate that the gravity field resolution up to harmonic degree 40 to 80 is feasible depending on various mission configurations. Radio tracking data from a six-month mission with a precision of 1 mm/s every 10 s and 300 km satellite separation at 150 km altitude will permit the determination of 5 deg x 5 deg mean gravity anomalies with an error of approximately 15 mgals. Consideration of other unaccounted error sources of instrumental, operational, and environmental nature may lower this resolution.

Iz, Huseyin B.↗

Software error detection

Several methods were employed to detect both the occurrence and source of errors in the operational software of the AN/SLQ-32. A large embedded real time electronic warfare command and control system for the ROLM 1606 computer are presented. The ROLM computer provides information about invalid addressing, improper use of privileged instructions, stack overflows, and unimplemented instructions. Additionally, software techniques were developed to detect invalid jumps, indices out of range, infinte loops, stack underflows, and field size errors. Finally, data are saved to provide information about the status of the system when an error is detected. This information includes I/O buffers, interrupt counts, stack contents, and recently passed locations. The various errors detected, techniques to assist in debugging problems, and segment simulation on a nontarget computer are discussed. These error detection techniques were a major factor in the success of finding the primary cause of error in 98% of over 500 system dumps.

Buechler, W.↗

Guaranteed Quality Conformal Mesh Decomposition.

Interface-conforming elements generated by the conformal decomposition finite element method can have arbitrarily poor quality due to the arbitrary intersection of the base triangular or tetrahedral mesh with material interfaces. This can have severe consequences for both the solvability of linear systems and for the interpolation error of fields represented on these meshes. The present work demonstrates that snapping the base mesh nodes to the interface whenever the interface cuts close to a node results in conforming meshes of good quality. Theoretical limits on the snapping tolerance are derived, and even conservative tolerance choices result in limiting the stiffness matrix condition number to within a small multiple of that of the base mesh. Interpolation errors are also well controlled in the norms of interest. In 3D, use of node-to-interface snapping also permits a simpler and more robust vertex ID-based element decomposition algorithm to be used with no serious detriment to mesh quality.

42 ENGINEERING↗

Dynamic Aperture and Tolerances for PEP-X Ultimate Storage Ring Design

A lattice for the PEP-X ultimate storage ring light source, having 11 pm-rad natural emittance at a beam energy of 4.5 GeV at zero current, using 90 m of damping wiggler and fitting into the existing 2.2-km PEP-II tunnel, has been recently designed. Such a low emittance lattice requires very strong sextupoles for chromaticity correction, which in turn introduce strong non-linear field effects that limit the beam dynamic aperture. In order to maximize the dynamic aperture we choose the cell phases to cancel the third and fourth order geometric resonances in each 8-cell arc. Four families of chromatic sextupoles and six families of geometric (or harmonic) sextupoles are added to correct the chromatic and amplitude-dependent tunes. To find the best settings of the ten sextupole families, we use a Multi-Objective Genetic Optimizer employing elegant to optimize the beam lifetime and dynamic aperture simultaneously. Then we evaluate dynamic aperture reduction caused by magnetic field multipole errors, magnet fabrication errors and misalignments. A sufficient dynamic aperture is obtained for injection, as well as workable beam lifetime.

43 PARTICLE ACCELERATORS↗

An accurate continuous calibration system for high voltage current transformer

A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

42 ENGINEERING↗

Hex-square moire patterns in imagers using microchannel plates

In electronic imaging detectors using microchannel plates, the mismatch between the pixels on a square mesh and the microchannels on a hexagonal mesh produces moire image defects. Theoretical statistical estimates of the sizes of the microposition offsets and the flat field intensity errors are calculated, showing the trade-off between resolution and position accuracy. A distinction is made between moments of spot images and moments of the single-pixel-response functions. As the resolution between the hex and square meshes is improved, the detector resolution is improved, but at the expense of an about 10 percent moire pattern. These moire patterns will not be properly corrected by dividing by the flat field image.

Lawrence, George M.↗