Search NASA⌕ Search

SEARCH · Search NASA

Results for “exponential time integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

346 records · Page 20

Integrated Multiscale Modeling of Molecular Computing Devices

Nanoscience has been one of the major research focuses of the U.S. and much of the world for the past decade, in part because of its promise to revolutionize many fields, including materials, medicine, and electronics. At the heart of this promise is the fact that nanostructured materials can behave radically differently than their macroscopic counterparts (e.g., bulk gold is such an inert metal that it has found applications in such diverse fields as jewelry, biomedical implants and dentistry, whereas gold nanoparticles are highly reactive and are thus useful as nanocatalysts) and have properties that are tunable due to a strong dependence on the size and surface area of the nanostructure. Thus, nanoscience offers a remarkable opportunity to develop new functional systems built around nanostructured materials with unusual and tunable properties and functionality. The transition from nanoscience to nanotechnology becomes possible when nanostructured systems can be made reproducibly by processes that can be implemented on a large scale. The microelectronics industry is one example of an industry that has evolved into the realm of nanotechnology, since the exponential reduction in feature size in computer chips has resulted in feature sizes now under 50nm (45nm in production, 32nm demonstrated; feature size has been going down by a factor of approximately 1/{radical}2 every 18 months as chip density has doubled every 18 months according to Moore's law). Silicon-based microelectronics relies on etching features into a single-crystal silicon substrate by photolithography. As the feature size of silicon-based microelectronics continues to decrease, the continuation of Moore's law to below 20nm feature sizes is being questioned, due to limitations in both the physics of the transistors (leading to unacceptable power dissipation) and doubts about the scalability of top-down photolithography-based manufacturing to such small sizes. There is no doubt that photolithography will some day reach a miniaturization limit, forcing designers of Si-based electronics to pursue increased performance by other means. Any other alternative approach would have the unenviable task of matching the ability of Si technology to pack more than a billion interconnected and addressable devices on a chip the size of a thumbnail. Nevertheless, the prospects of developing alternative approaches to fabricate electronic devices have spurred an ever-increasing pace of fundamental research. One of the promising possibilities is molecular electronics (ME), self-assembled molecular-based electronic systems composed of single-molecule devices in ultra dense, ultra fast molecular-sized components. This project focused on developing accurate, reliable theoretical modeling capabilities for describing molecular electronics devices. The participants in the project are given in Table 1. The primary outcomes of this fundamental computational science grant are publications in the open scientific literature. As listed below, 62 papers have been published from this project. In addition, the research has also been the subject of more than 100 invited talks at conferences, including several plenary or keynote lectures. Many of the goals of the original proposal were completed. Specifically, the multi-disciplinary group developed a unique set of capabilities and tools for investigating electron transport in fabricated and self-assembled nanostructures at multiple length and time scales.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Survey of Formal Methods for Intelligent Swarms

Swarms of intelligent autonomous spacecraft, involving complex behaviors and interactions, are being proposed for future space exploration missions. Such missions provide greater flexibility and offer the possibility of gathering more science data than traditional single spacecraft missions. The emergent properties of swarms make these missions powerful, but simultaneously far more difficult to design, and to assure that the proper behaviors will emerge. These missions are also considerably more complex than previous types of missions, and NASA, like other organizations, has little experience in developing or in verifying and validating these types of missions. A significant challenge when verifying and validating swarms of intelligent interacting agents is how to determine that the possible exponential interactions and emergent behaviors are producing the desired results. Assuring correct behavior and interactions of swarms will be critical to mission success. The Autonomous Nano Technology Swarm (ANTS) mission is an example of one of the swarm types of missions NASA is considering. The ANTS mission will use a swarm of picospacecraft that will fly from Earth orbit to the Asteroid Belt. Using an insect colony analogy, ANTS will be composed of specialized workers for asteroid exploration. Exploration would consist of cataloguing the mass, density, morphology, and chemical composition of the asteroids, including any anomalous concentrations of specific minerals. To perform this task, ANTS would carry miniaturized instruments, such as imagers, spectrometers, and detectors. Since ANTS and other similar missions are going to consist of autonomous spacecraft that may be out of contact with the earth for extended periods of time, and have low bandwidths due to weight constraints, it will be difficult to observe improper behavior and to correct any errors after launch. Providing V&V (verification and validation) for this type of mission is new to NASA, and represents the cutting edge in system correctness, and requires higher levels of assurance than other (traditional) missions that use a single or small number of spacecraft that are deterministic in nature and have near continuous communication access. One of the highest possible levels of assurance comes from the application of formal methods. Formal methods are mathematics-based tools and techniques for specifying and verifying (software and hardware) systems. They are particularly useful for specifying complex parallel systems, such as exemplified by the ANTS mission, where the entire system is difficult for a single person to fully understand, a problem that is multiplied with multiple developers. Once written, a formal specification can be used to prove properties of a system (e.g., the underlying system will go from one state to another or not into a specific state) and check for particular types of errors (e.g., race or livelock conditions). A formal specification can also be used as input to a model checker for further validation. This report gives the results of a survey of formal methods techniques for verification and validation of space missions that use swarm technology. Multiple formal methods were evaluated to determine their effectiveness in modeling and assuring the behavior of swarms of spacecraft using the ANTS mission as an example system. This report is the first result of the project to determine formal approaches that are promising for formally specifying swarm-based systems. From this survey, the most promising approaches were selected and are discussed relative to their possible application to the ANTS mission. Future work will include the application of an integrated approach, based on the selected approaches identified in this report, to the formal specification of the ANTS mission.

Truszkowski, Walt↗

Validation Data Acquisition in HTTF during PCC Events

A validation experimental campaign was conducted in an Integral Effect Test (IET) facility of High Temperature Gas Reactors (HTGR), the High-Temperature Test Facility (HTTF) at Oregon State University (OSU). The HTTF simulates Depressurized and Pressurized Conduction Cooldowns (DCC and PCC). This campaign required the development of a new laser spectroscopic diagnostic to measure velocity in the challenging conditions of the HTTF: low speed (~1 m/s) gas flows at HTGR prototypical temperature and 1/10th pressure. This was a collaborative effort between co-PIs at The George Washington University (GW), Oregon State University (OSU), and NASA Langley Research Center. The main accomplishments of this project include the record for dynamic range for velocimetry, highest accuracy obtained with this technique, successful deployment in an IET leading to new validation matrix for CFD. These are detailed below and in manuscript appended to this executive summary. For this project, we introduced a new class of laser spectroscopic diagnostics to Thermal-Hydraulics to measure velocity of gases; furthermore, the diagnostic was demonstrated in-situ in an IET during DCC events. In such scenarios, particles used in mainstream techniques, like Particle Image Velocimetry (PIV) are not appropriate as they settle down too rapidly and also contaminate the experimental facility. Molecular tracers stay mixed within the working gas and can seed the flow in a technique called Molecular Tagging Velocimetry (MTV). In MTV a molecular tracer is photo-dissociated by a first (write) laser into radicals or molecules. The pattern created by the write laser is then interrogated with planar laser-induced fluorescence (PLIF), the read pulse(s), which are recorded with a camera. The pattern is probed and matched at two times (interval or probe time, dt), resulting in a time-of-flight velocimetry technique. This project demonstrated a new application range for MTV in gases. MTV has been extensively used for high-speed gas dynamics: molecules do not suffer from inertia associated with particles in regions of high accelerations (such as shock waves). For high-speed flows, the probe time is on the order of 0.1-10 µs. In time-of-flight techniques, the velocity is reconstructed from the recorded displacement, dx, between time interval dt: U = dx/dt. To first order, the resolution of the pattern matching is typically a (fixed) fraction of a pixel; therefore the resolution of the velocity measurement increases with dx and, for a given flow velocity, dt. For the low-speed flows of interest here, this requires long probe time, and therefore finding tracers that are stable for a long time. After an extensive literature survey we identified 6 tracers that would be suitable. We also worked with Spectra Physics to design a custom laser system that is flexible enough to probe these various tracers. The final instrument is made of 4 lasers that are integrated into a compact and movable cart to facilitate the deployment of the instrument off-site. One unique aspect of the laser system is the tunable dye laser (needed to do PLIF of the radicals). By being pumped by two Nd:YAG lasers, this laser is able to provide two pulses with any probe time (dt) for wavelengths between 200 and 900 nm with a linewidth of 3 pm. Accommodating the dual-pulse capability required customizing the pump lasers and the dye laser, making this system unique. Additionally, a custom UV-intensified CCD camera capable of frame-straddling and exposure time as short as 10 ns was acquired. More than two-third of the instrument cost (~$200k) was covered by a cost sharing from the PI’s startup funds. Of the 6 potential tracers identified, two were tested extensively (H2O and N2O) at high-temperature and elevated pressure at GW prior to conducting the tests at OSU. For both tracers, an Ar-F laser (193 nm, 10 ns, 10 mJ/pulse) photo-dissociates trace amounts (0.1 – 5% molar fraction) of the gases into OH and NO. OH is probed at 281.905 nm and NO at 226.186 nm (4-30mJ, 10 ns pulse). NO is very stable in inert environment and we could reconstruct velocities precisely with probe delay times as long at 40 ms, compared to 2 ms for OH, resulting in increased precision. Therefore, for the tests in the HTTF, N2O was selected as the final tracer and its optimal concentration was determined to be 0.5% molar. In the GW laboratory, we obtained a velocity measurement precision of 4 mm/s at conditions mimicking the HTTF tests. We also demonstrated the benefit of molecular tracers over particles and the flexibility of our instrument by continuously measuring velocity from 1000 to 0.1 m/s in a blow down test. This represents a dynamic range on velocity of 80 dB, which is unprecedented for velocimetry! Once the diagnostic was optimized, two two-week campaigns were conducted in the HTTF. This experimental campaign required numerous practical solutions to successfully and rapidly deploy this very sensitive table-top diagnostic in-situ. This was accomplished thanks to very extensive planning from all parties involved in the project. Due to constraints on availability of the HTTF, only adiabatic DCC tests were conducted. Specifically, the velocity was measured at the exit of the hot leg into the Reactor Cavity Simulation Tank (RCST). We were able to record the gas velocity associated with the air ingress for long times (up to one hour). Depending on the initial conditions (density of the gases in the Reactor Pressure Vessel and the RCST) the lock exchange lasted 30-60 s past the valve openings. Large vortices were identified within the shear layer at the interface of the cross flow. These vortices are an indication of shear-driven instability between the counter streams of different density. After the lock-exchange, a small residual flow was still present and its strength decayed exponentially. It finds its source in a buoyancy difference between the gases in both vessels due to the mixing and diffusion of the gases in the cross-over duct and the RPV lower plenum. We did not expect to capture this part of the transient, which would have been less significant (if not negligible) in the presence of a heated core; the precision of our measurement in the HTTF was 6 mm/s, which exceeded our expectations for such a complex test! Using commercial software (Fluent) we simulated the experiment with Computational Fluid Dynamic (CFD) using Reynolds Averaged Navier-Stokes (RANS) turbulence models. We were not able to accurately reproduce the shear layer instability, mixing, and diffusion captured in our experimental data, even with large 3D meshes (>10 M points). We attributed this to the inadequacy of the RANS models for the flow of interest: our experimental Reynolds number was too low and was outside the applicability range of the RANS models. Instead, we should have employed CFD with less modeling, such as Large Eddy (LES) or even Direct Numerical (DNS) simulations. Unfortunately, we did not have the computational resources to do so. Finally, it should be noted that this experimental technique holds great promises for measuring velocity in thermalhydraulics. MTV has an application domain (highlighted in the narrative) that is complimentary to more established (and simpler) techniques, such as PIV. It has attracted the attention of several thermalhydraulics researchers and sponsors to measure velocity in harsh environments. The spectroscopic nature of this technique also enables to expand it to measure temperature and concentration simultaneously to velocity. In lieu of a narrative, 4 detailed journal publications are appended to this executive summary to describe the various development and accomplishments during this project. They include 2 published manuscripts (Experiments in Fluids and Measurement Science and Technology), and two invited contributions following the NURETH-17 conference (Nuclear Science and Technology). Our current Nuclear Engineering and Design draft is not included at this time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Virtual Microscope Views of the Apollo 11 and 12 Lunar Samples

The Apollo virtual microscope is a means of viewing, over the Internet, polished thin sections of every rock in the Apollo lunar sample collections via software, duplicating many of the functions of a petrological microscope, is described. Images from the Apollo 11 and 12 missions may be viewed at: www.virtualmicroscope.org/content/apollo. Introduction: During the six NASA missions to the Moon from 1969-72 a total of 382 kilograms of rocks and soils, often referred to as "the legacy of Apollo", were collected and returned to Earth. A unique collection of polished thin sections (PTSs) was made from over 400 rocks by the Lunar Sample Curatorial Facility at the Johnson Spacecraft Center (JSC), Houston. These materials have been available for loan to approved PIs but of course they can't be simultaneously investigated by several researchers unless they are co-located or the sample is passed back and forward between them by mail/hand carrying which is inefficient and very risky for irreplaceable material. When The Open University (OU), the world's largest Distance Learning Higher Education Establishment found itself facing a comparable problem (how to supply thousands of undergraduate students with an interactive petrological microscope and a personal set of thin sections), it decided to develop a software tool called the Virtual Microscope (VM). As a result it is now able to make the unique and precious collection of Apollo specimens universally available as a resource for concurrent study by anybody in the world's Earth and Planetary Sciences community. Herein, we describe the first steps of a collaborative project between OU and the Johnson Space Center (JSC) Curatorial Facility to record a PTS for every lunar rock, beginning with those collected by the Apollo 11 and 12 missions. Method: Production of a virtual microscope dedicated to a particular theme divides into four main parts - photography, image processing, building and assembly of virtual microscope components, and publication on a website. Two large research quality microscopes are used to collect all the images required for a virtual microscope. The first is part of an integrated package that utilizes Leica PowerMosaic software and a motorised XYZ stage to generate large area mosaics. It includes a fast acquisition camera and depending on the PTS size normally is used to produce seamless mosaic images consisting of 100-500 individual photographs. If the sample is suitable, three mosaics of each sample are recorded - plane polarised light, between crossed polars and reflected light. In order for the VM to be a true petrological microscope it is necessary to recreate the features of a rotating stage and perform observations using filters to produce polarised light. Thus the petrological VM includes the capability of seeing changes in optical properties (pleochroism and birefringence) during rotation allowing mineral identification. The second microscope in the system provides the functions of the rotating stage. To this microscope we have added a robotically controlled motor to acquire seventy-two images (5 degree intervals) in plane polarised light and between crossed polars. To process the images acquired from the two microscopes involves a combination of proprietary software (Photoshop) and our own in-house code. The final stage involves assembling all the components in an HTML5 environment. Pathfinder investigations: We have undertaken a number of pilot studies to demonstrate the efficacy of the petrological microscope with lunar samples. The first was to make available on-line images collected from the Educational Package of Apollo samples provided by NASA to the UK STFC (Science and Technical Facilities Council) for loan as educational material e.g. for schools. The real PTSs of the samples are now no longer sent out to schools removing the risks associated with transport, accidental breakage and eliminating the possibility of loss. The availability of lunar sample VM-related material was further extended to include twenty-eight specimens from all of the Apollo missions. Some of these samples were made more generally available through an ibook entitled "Moon Rocks: an introduction to the Geology of the Moon," free from the Apple Bookstore. Research possibilities: Although the Virtual Microscope was originally conceived as a teaching aid and was later recognised as a means of public outreach and engagement, we now realize that it also has enormous potential as a high level research tool. Following discussions with the JSC Curators we have received Curation and Analysis Planning Team for Extraterrestrial Materials (CAPTEM) permission to embark on a programme of digitizing the entire lunar sample PTS collection for all three of the above purposes. By the time of the 47th Lunar and Planetary Science Conference (LPSC) we will have completed 81 rocks collected during the Apollo 11 and 12 missions and the data, with cross-links to the Lunar Sample Compendium will go live on the Web at the 47th LPSC. The VM images of the Apollo 11 (41 VM images) and 12 (40 VM images) missions can be viewed at: http:/www.virtualmicroscope.org/content/apollo. The lunar sample VM will enable large numbers of skilled/unskilled microscopists (professional and amateur researchers, educators and students, enthusiasts and the simply curious non-scientists) to share the information from a single sample. It will mean that all the PTSs already cut, even historical ones, could be available for new joint investigations or private study. The scientific return from the collection will increase exponentially as a result of further debate and discussion. Simultaneously the VM will remove the need for making unnecessary multiple samplings, avoid consignment of delicate/breakable specimens (all of which are priceless) to insecure mail/courier services and reduce direct labour and indirect costs, travel budgets and unproductive travelling time necessary for co-location of collaborating researchers. For the future we have already recognized further potential for virtual technology. There is nothing that a petrologist likes more than to see the original rock as a hand specimen. It is entirely possible to recreate virtual hand specimens with 3-D hard and software, already developed for viewing fossils, located within the Curatorial Facility, http://curator.jsc.nasa.gov/lunar/lsc/index.cfm.

Gibson, E. K.↗