Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development and Validation of a SiC Based 50 kW Grid-Connected PV Inverter: Preprint

In this digest a 50kW string PV inverter formed using all SiC semiconductor devices is presented. The inverter design includes additively manufactured power block, symmetrical Y-core inductors for ac side filter, and advanced inverter functionality for grid support. This inverter utilizes the conventional three-phase Voltage Source Inverter topology and optimizes the design for SiC based devices. This paper presents the full functional validation of the designed inverter along with quantification of the efficiency and power density. The performance of the inverter for high dc-bus voltage without multi-level topology to exploit SiC advantages is also presented in this digest. The full paper will include details of inverter design, optimization and further experimental validation.

14 SOLAR ENERGY↗

Metrics for comparing plasma mass filters

High-throughput mass separation of nuclear waste may be useful for optimal storage, disposal, or environmental remediation. The most dangerous part of nuclear waste is the fission product, which produces most of the heat and medium-term radiation. Plasmas are well-suited to separating nuclear waste because they can separate many different species in a single step. A number of plasma devices have been designed for such mass separation, but there has been no standardized comparison between these devices. We define a standard metric, the separative power per unit volume, and derive it for three different plasma mass filters: the plasma centrifuge, Ohkawa filter, and the magnetic centrifugal mass filter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metrics for comparing plasma mass filters

High-throughput mass separation of nuclear waste may be useful for optimal storage, disposal, or environmental remediation. The most dangerous part of nuclear waste is the fission product, which produces most of the heat and medium-term radiation. Plasmas are well-suited to separating nuclear waste because they can separate many different species in a single step. A number of plasma devices have been designed for such mass separation, but there has been no standardized comparison between these devices. We define a standard metric, the separative power per unit volume, and derive it for three different plasma mass filters: the plasma centrifuge, Ohkawa filter, and the magnetic centrifugal mass filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of flow measurements using fluid-dynamic constraints

Novel experimental modalities acquire spatially resolved velocity measurements for steady state and transient flows which are of interest for engineering and biological applications. One of the drawbacks of such high resolution velocity data is their susceptibility to measurement errors. In this paper, we propose a novel filtering strategy that allows enhancement of the noisy measurements to obtain reconstruction of smooth divergence free velocity and corresponding pressure fields which together approximately comply to a prescribed flow model. The main step in our approach consists of the appropriate use of the velocity measurements in the design of a linearized flow model which can be shown to be well-posed and consistent with the true velocity and pressure fields up to measurement and modeling errors. The reconstruction procedure is then formulated as an optimal control problem for this linearized flow model. The resulting filter has analyzable smoothing and approximation properties. We briefly discuss the discretization of the approach by finite element methods and comment on the efficient solution by iterative methods. The capability of the proposed filter to significantly reduce data noise is demonstrated by numerical tests including the application to experimental data. In addition, we compare with other methods like smoothing and solenoidal filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Design of the LSST Camera

The Large Synoptic Survey Telescope (LSST) uses a novel, three-mirror, modified Paul-Baker design, with an 8.4-meter primary mirror, a 3.4-m secondary, and a 5.0-m tertiary feeding a camera system that includes a set of broad-band filters and refractive corrector lenses to produce a flat focal plane with a field of view of 9.6 square degrees. Optical design of the camera lenses and filters is integrated with optical design of telescope mirrors to optimize performance, resulting in excellent image quality over the entire field from ultra-violet to near infra-red wavelengths. The LSST camera optics design consists of three refractive lenses with clear aperture diameters of 1.55 m, 1.10 m and 0.69 m and six interchangeable, broad-band, filters with clear aperture diameters of 0.75 m. We describe the methodology for fabricating, coating, mounting and testing these lenses and filters, and we present the results of detailed tolerance analyses, demonstrating that the camera optics will perform to the specifications required to meet their performance goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of a phase-space beam position and size monitor for low-emittance light sources

The recently developed vertical phase-space beam position and size monitor (ps-BPM) system has proven to be able to measure the electron-source position, angle, size and divergence simultaneously in the vertical plane at a single location of a beamline. The optimization of the ps-BPM system is performed by ray-tracing simulation to maximize the instrument sensitivity and resolution. The contribution of each element is studied, including the monochromator, the K -edge filter, the detector and the source-to-detector distance. An optimized system is proposed for diffraction-limited storage rings, such as the Advanced Photon Source Upgrade project. The simulation results show that the ps-BPM system can precisely monitor the source position and angle at high speed. Precise measurements of the source size and divergence will require adequate resolution with relatively longer integration time.

47 OTHER INSTRUMENTATION↗

Information and Perception of Meaningful Patterns

The visual system needs to extract the most important elements of the external world from a large flux of information in a short time for survival purposes. It is widely believed that in performing this task, it operates a strong data reduction at an early stage, by creating a compact summary of relevant information that can be handled by further levels of processing. In this work we formulate a model of early vision based on a pattern-filtering architecture, partly inspired by high-speed digital data reduction in experimental high-energy physics (HEP). This allows a much stronger data reduction than models based just on redundancy reduction. We show that optimizing this model for best information preservation under tight constraints on computational resources yields surprisingly specific a-priori predictions for the shape of biologically plausible features, and for experimental observations on fast extraction of salient visual features by human observers. Interestingly, applying the same optimized model to HEP data acquisition systems based on pattern-filtering architectures leads to specific a-priori predictions for the relevant data patterns that these devices extract from their inputs. These results suggest that the limitedness of computing resources can play an important role in shaping the nature of perception, by determining what is perceived as ‘‘meaningful features’’ in the input data.

59 BASIC BIOLOGICAL SCIENCES↗

Survey on stochastic distribution systems: A full probability density function control theory with potential applications

Complex systems seen either in general engineering practice or economics are subjected to ever increased uncertainties that are mostly represented as random variables or parameters, and the characteristics of random variables are represented by their probability density functions (PDFs). Controlling their PDFs means to shape their stochastic distributions and in general it would provide a full treatment for system analysis and operational control and optimization. This leads to the development of stochastic distribution control (SDC) systems theory in the past decades, where the original aim of the controller design is to realize a shape control of the distributions of certain random variables in their PDFs sense for some engineering processes. Indeed, once the PDFs of these random variables or parameters are used to describe their distribution characters, the control task is to obtain control signals so that the output PDFs of stochastic systems are made to follow their target PDFs. The subject of SDC was initially originated for non-Gaussian stochastic control systems design but has found a wide spectrum of applications in general systems in terms of data-driven modeling, analysis, signal processing (filtering), data mining via multivariable statistics, decision-making (optimization) for systems subjected to uncertainties and even in economics. In this context, SDC constitutes an effective primer tool for complex system analysis, control and operational optimizations. In this review paper, a detailed survey of the developments on the research of SDC systems will be made together with their wide spectrum applications and future perspectives.

42 ENGINEERING↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Digital signal processing for the ATLAS/LUCID detector

Both the detector and the associated read-out electronics have been improved in order to cope with the LHC luminosity increase foreseen for RUN 2 and RUN 3. The new operating conditions require a careful tuning of the read-out electronics in order to optimize the signal-to-noise ratio. The new read-out electronics will allow the use of digital filtering of the photo multiplier tube signals. In this talk, we will present the first results that we obtained in the optimization of the signal-to-noise ratio. In addition, we will introduce the next steps to adapt this system to high performance read-out chains for low energy gamma rays. Such systems are based, for instance, on Silicon Drift Detector devices and can be used in applications at Free-Electron-Laser facilities such as the XFEL under construction at DESY. (authors)

43 PARTICLE ACCELERATORS↗

Carbon Capture Simulation Initiative: A Case Study in Multi-Scale Modeling and New Challenges

Abstract: Advanced multi-scale modeling and simulation has the potential to dramatically reduce development time, resulting in considerable cost savings. The Carbon Capture Simulation Initiative is a partnership among national laboratories, industry and universities that is developing and deploying a suite of multi-scale modeling and simulation tools including basic data submodels, steady-state and dynamic process models, process optimization and uncertainty quantification tools, an advanced dynamic process control framework, high-resolution filtered computational-fluid-dynamic (CFD) submodels, validated high-fidelity device-scale CFD models with quantified uncertainty, and a risk analysis framework. These tools and models enable basic data submodels, including thermodynamics and kinetics, to be used within detailed process models to synthesize and optimize a process. The resulting process informs the development of process control systems and more detailed simulations of potential equipment to improve the design and reduce scale-up risk. Quantification and propagation of uncertainty across scales is an essential part of these tools and models.

42 ENGINEERING↗

Development and application of processing and process control for nano-composite materials for lithium ion batteries (CRADA Final Report)

Oak Ridge National Laboratory and A123 Systems, Inc. collaborated on this project to develop a better understanding, quality control procedures, and safety testing for A123 System’s nanocomposite separator (NCS) technology which is a cell based patented technology and separator. NCS demonstrated excellent performance. x3450 prismatic cells were shown to survive >8000 cycles (1C/2C rate) at room temperature with greater than 80% capacity retention with only NCS present as an alternative to conventional polyolefin. However, for a successful commercialization, the coating conditions required to provide consistent and reliable product had not been optimized and QC techniques for being able to remove defective material before incorporation into a cell had not been developed. The work outlined in this report addresses these latter two points. First, experiments were conducted to understand temperature profiles during the different drying stages of the NCS coating when applied to both anode and cathode. One of the more interesting discoveries of this study was the observation of the large temperature decrease experienced by the wet coating between the end of the infrared (IR) drying stage and the beginning of the exposure to the convection drying oven. This is not a desirable situation as the temperature gradient could have a deleterious effect on coating quality. Based on this and other experimental data a radiative transfer model was developed for IR heating that also included a mass transfer module for drying. This will prove invaluable for battery coating optimization especially where IR drying is being employed. A stress model was also developed that predicts that under certain drying conditions tensile stresses are formed in the coating which could lead to cracking that is sometimes observed after drying is complete. Prediction of under what conditions these stresses form is vital to improving coating quality. In addition to understanding the drying process other parameters such as slurry quality and equipment optimization were examined. Removal of particles and gels by filtering, control of viscosity by %solids and mixing adjustments, removal of trapped gas in the slurry and modification of coater speed and slot die gap were all found to be important for producing uniform and flaw-free coatings. Second, an in-line Hi-Pot testing method has been developed specifically for NCS that will enable detection of coating flaws that could lead to soft or hard electrical shorts within the cell. In this way flawed material can be rejected before incorporation into the cell thus greatly reducing the amount of scrap that is generated. Improved battery safety is an extremely important benefit of NCS. Evaluation of battery safety is usually accomplished by conducting a variety of tests including nail penetration, hot box, over charge, etc. For these tests entire batteries must be built but the resultant temperature and voltage responses reveal little about the breakdown mechanism. In this report is described a pinch test which is used to evaluate NCS quality at various stages including coated anode and cathode as well as assembled cell. Coupled with post-microscopic examination of the damaged ‘pinch point’ test data can assist in the coating optimization from an improved end-use standpoint. As a result of this work two invention disclosures, one for optimizing drying methodology and the other for an in-line system for flaw detection, have been filed. In addition, 2 papers are being written for submission to peer-reviewed journals.

25 ENERGY STORAGE↗

Smoothing-based compressed state Kalman filter for joint state-parameter estimation: Applications in reservoir characterization and CO 2 storage monitoring

The operation of most engineered hydrogeological systems relies on simulating physical processes using numerical models with uncertain parameters and initial conditions. Predictions by such uncertain models can be greatly improved by Kalman-filter techniques that sequentially assimilate monitoring data. Each assimilation constitutes a nonlinear optimization, which is solved by linearizing an objective function about the model prediction and applying a linear correction to this prediction. However, if model parameters and initial conditions are uncertain, the optimization problem becomes strongly nonlinear and a linear correction may yield unphysical results. In this paper, we investigate the utility of one-step ahead smoothing, a variant of the traditional filtering process, to eliminate nonphysical results and reduce estimation artifacts caused by nonlinearities. Here, we present the smoothing-based compressed state Kalman filter (sCSKF), an algorithm that combines one step ahead smoothing, in which current observations are used to correct the state and parameters one step back in time, with a nonensemble covariance compression scheme, that reduces the computational cost by efficiently exploring the high-dimensional state and parameter space. Numerical experiments show that when model parameters are uncertain and the states exhibit hyperbolic behavior with sharp fronts, as in CO 2 storage applications, one-step ahead smoothing reduces overshooting errors and, by design, gives physically consistent state and parameter estimates. We compared sCSKF with commonly used data assimilation methods and showed that for the same computational cost, combining one step ahead smoothing and nonensemble compression is advantageous for real-time characterization and monitoring of large-scale hydrogeological systems with sharp moving fronts.

42 ENGINEERING↗

Social and Demographic Factors Influencing Inferior Vena Cava Filter Retrieval at a Single Institution in the United States

PurposeRetrievable inferior vena cava filters (IVCFs) are associated with long-term adverse events that have increased interest in improving filter retrieval rates. Determining the influential patient social and demographic factors affecting IVCF retrieval is important to personalize patient management strategies and attain optimal patient care.Materials and MethodsSeven-hundred and sixty-two patients were retrospectively studied who had a filter placed at our institution between January 2011 and November 2013. Age, gender, race, cancer history, distance to residence from retrieval institution, and insurance status were identified for each patient, and those receiving retrievable IVCFs were further evaluated for retrieval rate and time to retrieval.ResultsOf the 762 filters placed, 133 were permanent filters. Of the 629 retrievable filters placed, 406 met the inclusion criteria and were eligible for retrieval. Results revealed patients with Medicare were less likely to have their filters retrieved (p = 0.031). Older age was also associated with a lower likelihood of retrieval (p < 0.001) as was living further from the medical center (p = 0.027). Patients who were white and had Medicare were more likely than similarly insured black patients to have their filters retrieved (p = 0.024).ConclusionsThe retrieval rate of IVCFs was most influenced by insurance status, distance from the medical center, and age. Race was statistically significant only when combined with insurance status. The results of this study suggest that these patient groups may need closer follow-up in order to obtain optimal IVCF retrieval rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and fabrication of optical thin films for remote sensing instruments

Optical thin films designed for multispectral band-pass filters and a primary Ag mirror were deposited on radiation-resistant glass by ion-beam-assisted deposition. The filters and mirror are for use in the optical payload of a remote sensing instrument. The optical parameters of the films and mirror were optimized by using admittance loci analysis. The simulation shows that the band-pass filters can achieve average transmittances of 95% in the blue (B1), green (B2), red (B3), near-infrared (B4), and panchromatic (400-900 nm) spectral ranges and an average reflectance of 99% for the primary Ag mirror in the visible spectrum. The corresponding properties of the films were investigated by in situ optical monitoring, spectrometry, and high-resolution transmission electron microscopy. It was found that the average transmittances are above 85% for all five band-pass filters, with a rejection transmittance below 1% in the spectral range of 350-1100 nm. The average reflectance of the primary Ag mirror (with a protective coating) is above 98%. Interference coatings were added to the basic protected silver design to enhance the reflectance in the visible spectral range. Furthermore, to investigate the optical stability of optical thin films for aerospace applications, a space environment was simulated by using a Co{sup 60} gamma ({gamma}) radiation source (total doses of 35 krad and 1 Mrad). The experimental results indicate that both the dielectric thin film stacks and radiation-protected glass are resistant to {gamma} radiation in the simulated space environment.

36 MATERIALS SCIENCE↗

Grid artifact reduction for direct digital radiography detectors based on rotated stationary grids with homomorphic filtering

Purpose: Grid artifacts are caused when using the antiscatter grid in obtaining digital x-ray images. In this paper, research on grid artifact reduction techniques is conducted especially for the direct detectors, which are based on amorphous selenium. Methods: In order to analyze and reduce the grid artifacts, the authors consider a multiplicative grid image model and propose a homomorphic filtering technique. For minimal damage due to filters, which are used to suppress the grid artifacts, rotated grids with respect to the sampling direction are employed, and min-max optimization problems for searching optimal grid frequencies and angles for given sampling frequencies are established. The authors then propose algorithms for the grid artifact reduction based on the band-stop filters as well as low-pass filters. Results: The proposed algorithms are experimentally tested for digital x-ray images, which are obtained from direct detectors with the rotated grids, and are compared with other algorithms. It is shown that the proposed algorithms can successfully reduce the grid artifacts for direct detectors. Conclusions: By employing the homomorphic filtering technique, the authors can considerably suppress the strong grid artifacts with relatively narrow-bandwidth filters compared to the normal filtering case. Using rotated grids also significantly reduces the ringing artifact. Furthermore, for specific grid frequencies and angles, the authors can use simple homomorphic low-pass filters in the spatial domain, and thus alleviate the grid artifacts with very low implementation complexity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient phase-factor evaluation in quantum signal processing

Quantum signal processing (QSP) is a powerful quantum algorithm to exactly implement matrix polynomials on quantum computers. Asymptotic analysis of quantum algorithms based on QSP has shown that asymptotically optimal results can in principle be obtained for a range of tasks, such as Hamiltonian simulation and the quantum linear system problem. A further benefit of QSP is that it uses a minimal number of ancilla qubits, which facilitates its implementation on near-to-intermediate term quantum architectures. However, there is so far no classically stable algorithm allowing computation of the phase factors that are needed to build QSP circuits. Existing methods require the use of variable precision arithmetic and can only be applied to polynomials of a relatively low degree. We present here an optimization-based method that can accurately compute the phase factors using standard double precision arithmetic operations. We demonstrate the performance of this approach with applications to Hamiltonian simulation, eigenvalue filtering, and quantum linear system problems. Furthermore, our numerical results show that the optimization algorithm can find phase factors to accurately approximate polynomials of a degree larger than 10000 with errors below 10 -12 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗